메뉴 건너뛰기




Volumn 88, Issue 8, 2011, Pages 912-919

Lenstar versus ultrasound for ocular biometry in a pediatric population

Author keywords

A scan contact ultrasound; Optical biometry; optical low coherence reflectometer; pachymetry; pediatric population

Indexed keywords

A-SCAN CONTACT ULTRASOUND; LOW-COHERENCE REFLECTOMETER; OPTICAL BIOMETRY; PACHYMETRY; PEDIATRIC POPULATION;

EID: 80051548885     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e31821cc4d6     Document Type: Article
Times cited : (46)

References (53)
  • 1
    • 35748969315 scopus 로고    scopus 로고
    • Biometry data from Caucasian and African-American cataractous pediatric eyes
    • DOI 10.1167/iovs.07-0267
    • Trivedi RH, Wilson ME. Biometry data from Caucasian and African-American cataractous pediatric eyes. Invest Ophthalmol Vis Sci 2007;48:4671-8. (Pubitemid 351260985)
    • (2007) Investigative Ophthalmology and Visual Science , vol.48 , Issue.10 , pp. 4671-4678
    • Trivedi, R.H.1    Wilson, M.E.2
  • 2
    • 0023789485 scopus 로고
    • Congenital and traumatic cataract. The effect on ocularaxial length
    • Rasooly R, Ben Ezra D. Congenital and traumatic cataract. The effect on ocularaxial length. Arch Ophthalmol 1988;106:1066-8.
    • (1988) Arch Ophthalmol , vol.106 , pp. 1066-8
    • Rasooly, R.1    Ben Ezra, D.2
  • 4
    • 58149316238 scopus 로고    scopus 로고
    • Current thoughts in pediatric refractive surgery
    • Stahl ED. Current thoughts in pediatric refractive surgery. J Pediatr Ophthalmol Strabismus 2008;45:331-7.
    • (2008) J Pediatr Ophthalmol Strabismus , vol.45 , pp. 331-7
    • Stahl, E.D.1
  • 5
    • 39849104145 scopus 로고    scopus 로고
    • IOP, myopic progression and axial length in a COMET subgroup
    • DOI 10.1097/OPX.0b013e3181622633, PII 0000632420080200000008
    • Manny RE, Deng L, Crossnoe C, Gwiazda J. IOP, myopic progres-sion and axial length in a COMET subgroup. Optom Vis Sci 2008; 85:97-105. (Pubitemid 351315436)
    • (2008) Optometry and Vision Science , vol.85 , Issue.2 , pp. 97-105
    • Manny, R.E.1    Deng, L.2    Crossnoe, C.3    Gwiazda, J.4
  • 6
    • 67651152888 scopus 로고    scopus 로고
    • Correlation between myopia and major biometric parameters of the eye: A retro-spective clinical study
    • Xie R, Zhou XT, Lu F, Chen M, Xue A, Chen S, Qu J. Correlation between myopia and major biometric parameters of the eye: a retro-spective clinical study. Optom Vis Sci 2009;86:503-8.
    • (2009) Optom Vis Sci , vol.86 , pp. 503-8
    • Xie, R.1    Zhou, X.T.2    Lu, F.3    Chen, M.4    Xue, A.5    Chen, S.6    Qu, J.7
  • 7
    • 58149131454 scopus 로고    scopus 로고
    • The effective-ness of progressive addition lenses on the progression of myopia in Chinese children
    • Yang Z, Lan W, Ge J, Liu W, Chen X, Chen L, Yu M. The effective-ness of progressive addition lenses on the progression of myopia in Chinese children. Ophthalmic Physiol Opt 2009;29:41-8.
    • (2009) Ophthalmic Physiol Opt , vol.29 , pp. 41-8
    • Yang, Z.1    Lan, W.2    Ge, J.3    Liu, W.4    Chen, X.5    Chen, L.6    Yu, M.7
  • 11
    • 53049083889 scopus 로고    scopus 로고
    • Accuracy of IOL calculations in children: A comparison of im-mersion versus contact A-scan biometery
    • Ben-Zion I, Neely DE, Plager DA, Ofner S, Sprunger DT, Roberts GJ. Accuracy of IOL calculations in children: a comparison of im-mersion versus contact A-scan biometery. J AAPOS 2008;12:440-4.
    • (2008) J AAPOS , vol.12 , pp. 440-4
    • Ben-Zion, I.1    Neely, D.E.2    Plager, D.A.3    Ofner, S.4    Sprunger, D.T.5    Roberts, G.J.6
  • 12
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability ofcorneal thickness measures
    • Marsich MW, Bullimore MA. The repeatability ofcorneal thickness measures. Cornea 2000;19:792-5.
    • (2000) Cornea , vol.19 , pp. 792-5
    • Marsich, M.W.1    Bullimore, M.A.2
  • 13
    • 0026588378 scopus 로고
    • Comparison ofcentral corneal thickness measurements between optical and ultrasound pachometers
    • Giasson C, Forthomme D. Comparison ofcentral corneal thickness measurements between optical and ultrasound pachometers. Optom Vis Sci 1992;69:236-41.
    • (1992) Optom Vis Sci , vol.69 , pp. 236-41
    • Giasson, C.1    Forthomme, D.2
  • 14
    • 0942301213 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
    • DOI 10.1136/bjo.2003.023416
    • Miglior S, Albe E, Guareschi M, Mandelli G, Gomarasca S, Orzalesi N. Intraobserver and interobserver reproducibility in the evaluation ofultrasonic pachymetry measurements ofcentral corneal thickness. Br J Ophthalmol 2004;88:174-7. (Pubitemid 38142079)
    • (2004) British Journal of Ophthalmology , vol.88 , Issue.2 , pp. 174-177
    • Miglior, S.1    Albe, E.2    Guareschi, M.3    Mandelli, G.4    Gomarasca, S.5    Orzalesi, N.6
  • 15
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • Hitzenberger CK. Optical measurement of the axial eye length by laser Doppler interferometry. Invest Ophthalmol Vis Sci 1991;32: 616-24.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-24
    • Hitzenberger, C.K.1
  • 17
    • 43649103045 scopus 로고    scopus 로고
    • Evaluation of a new IOLMaster algorithm to measure axial length
    • DOI 10.1016/j.jcrs.2008.02.021, PII S0886335008002897
    • Hill W, Angeles R, Otani T. Evaluation of a new IOLMaster algo-rithm to measure axial length. J Cataract Refract Surg 2008;34: 920-4 (Pubitemid 351685638)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.6 , pp. 920-924
    • Hill, W.1    Angeles, R.2    Otani, T.3
  • 18
    • 0019432970 scopus 로고
    • The accuracy of ultrasonic measurement of the axial length of the eye
    • Binkhorst RD. The accuracy ofultrasonic measurement of the axial length of the eye. Ophthalmic Surg 1981;12:363-5. (Pubitemid 11093875)
    • (1981) Ophthalmic Surgery , vol.12 , Issue.5 , pp. 363-365
    • Binkhorst, R.D.1
  • 19
    • 0019156126 scopus 로고
    • Accuracy of intraocular lens powers calculated from A-scan biometry with the echo-oculometer
    • Schachar RA, Levy NS, Bonney RC. Accuracy of intraocular lens powers calculated from A-scan biometry with the Echo-Oculometer. Ophthalmic Surg 1980;11:856-8. (Pubitemid 11187502)
    • (1980) Ophthalmic Surgery , vol.11 , Issue.12 , pp. 856-858
    • Schachar, R.A.1    Levy, N.S.2    Bonney, R.C.3
  • 22
    • 70350567196 scopus 로고    scopus 로고
    • Comparison and evaluation ofocular biometry using a new noncontact optical low-coherence reflectometer
    • Rohrer K, Frueh BE, Walti R, Clemetson IA, Tappeiner C, Gold-blum D. Comparison and evaluation ofocular biometry using a new noncontact optical low-coherence reflectometer. Ophthalmology 2009;116:2087-92.
    • (2009) Ophthalmology , vol.116 , pp. 2087-92
    • Rohrer, K.1    Frueh, B.E.2    Walti, R.3    Clemetson, I.A.4    Tappeiner, C.5    Gold-Blum, D.6
  • 24
    • 0035205647 scopus 로고    scopus 로고
    • Reproducibility of optical biometry using partial coherence interferometry: Intraobserver and interobserver reliability
    • DOI 10.1016/S0886-3350(01)01214-7, PII S0886335001012147
    • Vogel A, Dick HB, Krummenauer F. Reproducibility ofoptical bi-ometry using partial coherence interferometry: intraobserver and in-terobserver reliability. J Cataract Refract Surg 2001;27:1961-8. (Pubitemid 33136176)
    • (2001) Journal of Cataract and Refractive Surgery , vol.27 , Issue.12 , pp. 1961-1968
    • Vogel, A.1    Dick, H.2    Krummenauer, F.3
  • 25
    • 79955704174 scopus 로고    scopus 로고
    • Re-producibility ofocular biometry with a new noncontact optical low-coherence reflectometer in children
    • Sahin A, Gursoy H, Basmak H, Yildirim N, Usalp Z, Colak E. Re-producibility ofocular biometry with a new noncontact optical low-coherence reflectometer in children. Eur J Ophthalmol 2011;21: 194-8.
    • (2011) Eur J Ophthalmol , vol.21 , pp. 194-8
    • Sahin, A.1    Gursoy, H.2    Basmak, H.3    Yildirim, N.4    Usalp, Z.5    Colak, E.6
  • 26
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Atman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: 307-10. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 27
    • 0042206359 scopus 로고    scopus 로고
    • IOLMaster biometry: Refractive results of 100 consecutive cases
    • DOI 10.1136/bjo.87.8.960
    • Eleftheriadis H. IOLMaster biometry: refractive results of 100 con-secutive cases. Br J Ophthalmol 2003;87:960-3. (Pubitemid 36936290)
    • (2003) British Journal of Ophthalmology , vol.87 , Issue.8 , pp. 960-963
    • Eleftheriadis, H.1
  • 28
    • 38649099691 scopus 로고    scopus 로고
    • Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length
    • Wang JK, Hu CY, Chang SW. Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length.J Cataract Refract Surg 2008;34:262-7.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 262-7
    • Wang, J.K.1    Hu, C.Y.2    Chang, S.W.3
  • 29
    • 0037693009 scopus 로고    scopus 로고
    • Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: Biometry for intraocular lens calculation
    • DOI 10.1046/j.1442-9071.2003.00617.x
    • Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calcula-tion. Clin Experiment Ophthalmol 2003;31:121-4. (Pubitemid 36553134)
    • (2003) Clinical and Experimental Ophthalmology , vol.31 , Issue.2 , pp. 121-124
    • Rose, L.T.1    Moshegov, C.N.2
  • 30
    • 0036069424 scopus 로고    scopus 로고
    • Reproducibility of the IOL Master
    • Gobin L. Reproducibility of the IOL Master. J Cataract Refract Surg 2002;28:1087-8.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1087-8
    • Gobin, L.1
  • 32
    • 41249103707 scopus 로고    scopus 로고
    • Biometric calculation of intraocular lens power for cataract surgery following pupil dilatation
    • DOI 10.1111/j.1442-9071.2008.01700.x
    • Bansal S, Quah SA, Turpin T, Batterbury M. Biometric calculation of intraocular lens power for cataract surgery following pupil dilata-tion. Clin Experiment Ophthalmol 2008;36:156-8. (Pubitemid 351445149)
    • (2008) Clinical and Experimental Ophthalmology , vol.36 , Issue.2 , pp. 156-158
    • Bansal, S.1    Quah, S.A.2    Turpin, T.3    Batterbury, M.4
  • 34
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with pentacam, orbscan, and ultrasound
    • DOI 10.1097/01.opx.0000180817.46312.0a
    • Lackner B, Schmidinger G, Pieh S, Funovics MA, Skorpik C. Repeat-ability and reproducibility ofcentral corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci 2005;82: 892-9. (Pubitemid 41566871)
    • (2005) Optometry and Vision Science , vol.82 , Issue.10 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3    Funovics, M.A.4    Skorpik, C.5
  • 36
    • 0027054040 scopus 로고
    • Short-term effects of proparacaine on human corneal thickness
    • Herse P, Siu A. Short-term effects ofproparacaine on human corneal thickness. Acta Ophthalmol (Copenh) 1992;70:740-4. (Pubitemid 23029607)
    • (1992) Acta Ophthalmologica , vol.70 , Issue.6 , pp. 740-744
    • Herse, P.1    Siu, A.2
  • 37
    • 0042344722 scopus 로고    scopus 로고
    • Corneal thickness values before and after oxybuprocaine 0.4% eye drops
    • DOI 10.1097/00003226-200308000-00008
    • Asensio I, Rahhal SM, Aonso L, Palanca-Sanfrancisco JM, Sanchis-Gimeno JA. Corneal thickness values before and after oxybuprocaine 0.4% eye drops. Cornea 2003;22:527-32. (Pubitemid 36909731)
    • (2003) Cornea , vol.22 , Issue.6 , pp. 527-532
    • Asensio, I.1    Rahhal, S.M.2    Alonso, L.3    Palanca-Sanfrancisco, J.M.4    Sanchis-Gimeno, J.A.5
  • 38
    • 29744470169 scopus 로고    scopus 로고
    • Comparison of corneal thickness after the instillation of topical anesthetics: Proparacaine versus oxybuprocaine
    • DOI 10.1097/01.ico.0000179929.97651.59
    • Nam SM, Lee HK, Kim EK, Seo KY. Comparison ofcorneal thick-ness after the instillation of topical anesthetics: proparacaine versus oxybuprocaine. Cornea 2006;25:51-4. (Pubitemid 43031150)
    • (2006) Cornea , vol.25 , Issue.1 , pp. 51-54
    • Nam, S.M.1    Lee, H.K.2    Kim, E.K.3    Seo, K.Y.4
  • 39
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 1992;18:125-9. (Pubitemid 23237029)
    • (1992) Journal of Cataract and Refractive Surgery , vol.18 , Issue.2 , pp. 125-129
    • Olsen, T.1
  • 40
    • 0023090780 scopus 로고
    • Theoretical, computer-assisted prediction versus SRK prediction of postoperative refraction after intraocular lens implantation
    • Olsen T. Theoretical, computer-assisted prediction versus SRK pre-diction ofpostoperative refraction after intraocular lens implantation. J Cataract Refract Surg 1987;13:146-50. (Pubitemid 17053423)
    • (1987) Journal of Cataract and Refractive Surgery , vol.13 , Issue.2 , pp. 146-150
    • Olsen, T.1
  • 41
    • 0043173718 scopus 로고    scopus 로고
    • Comparison of laser interferometry and ultrasound A-scan in the measurement of axial length
    • DOI 10.1034/j.1600-0420.2003.00092.x
    • Goyal R, North RV, Morgan JE. Comparison oflaser interferometry and ultrasound A-scan in the measurement ofaxial length. Acta Ophthalmol Scand 2003;81:331-5. (Pubitemid 36926859)
    • (2003) Acta Ophthalmologica Scandinavica , vol.81 , Issue.4 , pp. 331-335
    • Goyal, R.1    North, R.V.2    Morgan, J.E.3
  • 42
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intra-ocular lens calculation according to Haigis
    • Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intra-ocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000;238:765-73.
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 765-73
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 45
    • 0037386370 scopus 로고    scopus 로고
    • Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound
    • Tehrani M, Krummenauer F, Kumar R, Dick HB. Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound. J Cataract Refract Surg 2003;29:747-52.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 747-52
    • Tehrani, M.1    Krummenauer, F.2    Kumar, R.3    Dick, H.B.4
  • 46
    • 33748436360 scopus 로고    scopus 로고
    • Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children
    • DOI 10.1038/sj.eye.6702069, PII 6702069
    • Hussin HM, Spry PG, Majid MA, Gouws P. Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children. Eye (Lond) 2006;20:1021-4. (Pubitemid 44340319)
    • (2006) Eye , vol.20 , Issue.9 , pp. 1021-1024
    • Hussin, H.M.1    Spry, P.G.D.2    Majid, M.A.3    Gouws, P.4
  • 47
    • 68349133399 scopus 로고    scopus 로고
    • Comparison ofrefractive outcomes using im-mersion ultrasound biometry and IOL Master biometry
    • Landers J, Goggin M. Comparison ofrefractive outcomes using im-mersion ultrasound biometry and IOL Master biometry. Clin Exper-iment Ophthalmol 2009;37:566-9.
    • (2009) Clin Exper-iment Ophthalmol , vol.37 , pp. 566-9
    • Landers, J.1    Goggin, M.2
  • 49
    • 2942538426 scopus 로고    scopus 로고
    • Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster
    • DOI 10.1016/j.jcrs.2003.11.053, PII S0886335004000094
    • Reddy AR, Pande MV, Finn P, El-Gogary H. Comparative estima-tion of anterior chamber depth by ultrasonography, Orbscan II, and IOL Master. J Cataract Refract Surg 2004;30:1268-71. (Pubitemid 38748441)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.6 , pp. 1268-1271
    • Reddy, A.R.1    Pande, M.V.2    Finn, P.3    El-Gogary, H.4
  • 50
    • 25644448981 scopus 로고    scopus 로고
    • Validity and repeatability of anterior chamber depth measurements with pentacam and orbscan
    • DOI 10.1097/01.opx.0000177804.53192.15
    • Lackner B, Schmidinger G, Skorpik C. Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci 2005;82:858-61. (Pubitemid 41384113)
    • (2005) Optometry and Vision Science , vol.82 , Issue.9 , pp. 858-861
    • Lackner, B.1    Schmidinger, G.2    Skorpik, C.3
  • 51
    • 0026776531 scopus 로고
    • Repeatability, repro-ducibility and intersession variability of the Allergan Humphrey ul-trasonic biometer
    • Rudnicka AR, Steele CF, Crabb DP, Edgar DF. Repeatability, repro-ducibility and intersession variability of the Allergan Humphrey ul-trasonic biometer. Acta Ophthalmol (Copenh) 1992;70:327-34.
    • (1992) Acta Ophthalmol (Copenh) , vol.70 , pp. 327-34
    • Rudnicka, A.R.1    Steele, C.F.2    Crabb, D.P.3    Edgar, D.F.4
  • 52
    • 0026652930 scopus 로고
    • The repeatability ofmeasurement of the ocular components
    • Zadnik K, Mutti DO, Adams AJ. The repeatability ofmeasurement of the ocular components. Invest Ophthalmol Vis Sci 1992;33: 2325-33.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2325-33
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3
  • 53
    • 0742322729 scopus 로고    scopus 로고
    • Variability of the Ocular Component Measurements in Children Using A-Scan Ultrasonography
    • DOI 10.1097/00006324-200401000-00008
    • Kurtz D, Manny R, Hussein M. Variability of the ocular component measurements in children using A-scan ultrasonography. Optom Vis Sci 2004;81:35-43. (Pubitemid 38160810)
    • (2004) Optometry and Vision Science , vol.81 , Issue.1 , pp. 35-43
    • Kurtz, D.1    Manny, R.2    Hussein, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.