메뉴 건너뛰기




Volumn 30, Issue 6, 2004, Pages 1268-1271

Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster

Author keywords

[No Author keywords available]

Indexed keywords

A SCAN; ADULT; AGED; ANALYSIS OF VARIANCE; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; CATARACT EXTRACTION; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; ECHOGRAPHY; ECHOOCULOGRAPHY; HUMAN; INTERFEROMETRY; INTERMETHOD COMPARISON; MEASUREMENT; PARTIAL COHERENCE INTERFEROMETRY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SCANNING SLIT TOPOGRAPHY; SCINTIGRAPHY; SENILE CATARACT; STATISTICAL SIGNIFICANCE; TOPOGRAPHY;

EID: 2942538426     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2003.11.053     Document Type: Article
Times cited : (80)

References (16)
  • 1
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 18:1992;125-129
    • (1992) J Cataract Refract Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 2
    • 0023698244 scopus 로고
    • Prediction of pseudo-phakic anterior chamber depth from pre-operative data
    • Naeser K., Boberg-Ans J., Bargum R. Prediction of pseudo-phakic anterior chamber depth from pre-operative data. Acta Ophthalmol. 66:1988;433-437
    • (1988) Acta Ophthalmol , vol.66 , pp. 433-437
    • Naeser, K.1    Boberg-Ans, J.2    Bargum, R.3
  • 3
    • 0030817812 scopus 로고    scopus 로고
    • Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations
    • Holladay J.T. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg. 23:1997;1356-1370
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1356-1370
    • Holladay, J.T.1
  • 4
    • 0027276169 scopus 로고
    • Refractive power calculations for intraocular lenses in the phakic eye
    • Holladay J.T. Refractive power calculations for intraocular lenses in the phakic eye. Am J Ophthalmol. 116:1993;63-66
    • (1993) Am J Ophthalmol , vol.116 , pp. 63-66
    • Holladay, J.T.1
  • 5
    • 0033510679 scopus 로고    scopus 로고
    • Phakic anterior chamber lenses for correction of myopia; A 7-year cumulative analysis of complications in 263 cases
    • Alio J.L., de la Hoz F., Pérez-Santonja J.J., et al. Phakic anterior chamber lenses for correction of myopia; a 7-year cumulative analysis of complications in 263 cases. Ophthalmology. 106:1999;458-466
    • (1999) Ophthalmology , vol.106 , pp. 458-466
    • Alio, J.L.1    De La Hoz, F.2    Pérez-Santonja, J.J.3
  • 7
    • 0035195625 scopus 로고    scopus 로고
    • Biométrie oculaire à l'aide d'une fente lumineuse (Orbiscan®)
    • Allouch C., Touzeau O., Borderie V., et al. Biométrie oculaire à l'aide d'une fente lumineuse (Orbiscan®). J Fr Ophtalmol. 24:2001;710-715
    • (2001) J Fr Ophtalmol , vol.24 , pp. 710-715
    • Allouch, C.1    Touzeau, O.2    Borderie, V.3
  • 8
    • 0033820671 scopus 로고    scopus 로고
    • Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant
    • Vetrugno M., Cardascia N., Cardia L. Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant. Br J Ophthalmol. 84:2000;1113-1116
    • (2000) Br J Ophthalmol , vol.84 , pp. 1113-1116
    • Vetrugno, M.1    Cardascia, N.2    Cardia, L.3
  • 10
    • 0035205647 scopus 로고    scopus 로고
    • Reproducibility of optical biometry using partial coherence interferometry; Intraobserver and interobserver reliability
    • Vogel A., Dick H.B., Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry; intraobserver and interobserver reliability. J Cataract Refract Surg. 27:2001;1961-1968
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1961-1968
    • Vogel, A.1    Dick, H.B.2    Krummenauer, F.3
  • 11
    • 0036169561 scopus 로고    scopus 로고
    • Anterior chamber depth measurement: A-scan versus optical methods
    • Koranyi G., Lydahl E., Norrby S., Taube M. Anterior chamber depth measurement. A-scan versus optical methods J Cataract Refract Surg. 28:2002;243-247
    • (2002) J Cataract Refract Surg , vol.28 , pp. 243-247
    • Koranyi, G.1    Lydahl, E.2    Norrby, S.3    Taube, M.4
  • 12
    • 0031928879 scopus 로고    scopus 로고
    • High precision biometry of pseudophakic eyes using partial coherence interferometry
    • Findl O., Drexler W., Menapace R., et al. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg. 24:1998;1087-1093
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1087-1093
    • Findl, O.1    Drexler, W.2    Menapace, R.3
  • 13
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    • Haigis W., Lege B., Miller N., Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 238:2000;765-773
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 765-773
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 14
    • 0035662523 scopus 로고    scopus 로고
    • Intérêt d'un nouveau biomètre non-contact pour le calcul de la puissance des lentilles intra-oculaires cristalliniennes
    • Meyer F., Renard J.P., Roux L., et al. Intérêt d'un nouveau biomètre non-contact pour le calcul de la puissance des lentilles intra-oculaires cristalliniennes. J Fr Ophtalmol. 24:2001;1060-1066
    • (2001) J Fr Ophtalmol , vol.24 , pp. 1060-1066
    • Meyer, F.1    Renard, J.P.2    Roux, L.3
  • 15
    • 0024309262 scopus 로고
    • The accuracy of ultrasonic determination of axial length in pseudophakic eyes
    • Olsen T. The accuracy of ultrasonic determination of axial length in pseudophakic eyes. Acta Ophthalmol. 67:1989;141-144
    • (1989) Acta Ophthalmol , vol.67 , pp. 141-144
    • Olsen, T.1
  • 16
    • 0018937490 scopus 로고
    • Biometry of 7,500 cataractous eyes
    • correction, 890
    • Hoffer K.J. Biometry of 7, 500 cataractous eyes. Am J Opthalmol. 90:1980;360-368. correction, 890
    • (1980) Am J Opthalmol , vol.90 , pp. 360-368
    • Hoffer, K.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.