Volumn 81, Issue 1, 2004, Pages 35-43

Variability of the Ocular Component Measurements in Children Using A-Scan Ultrasonography

Author keywords

A scan; Biometry; Development; Myopia; Precision; Refractive error; Technique; Ultrasonography; Variability

Indexed keywords

ERROR CORRECTION; EYE CONTROLLED DEVICES; LENSES; OPTOELECTRONIC DEVICES; SONOCHEMISTRY; ULTRASONICS;

EID: 0742322729     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006324-200401000-00008     Document Type: Article
Times cited : (26)

References (30)
  • 1
    • 0027504351 scopus 로고
    • Emmetropization and the progression of manifest refraction in children followed from infancy to puberty
    • Gwiazda J, Thorn F, Bauer J, Held R. Emmetropization and the progression of manifest refraction in children followed from infancy to puberty. Clin Vis Sci 1993;8:337-44.
    • (1993) Clin Vis Sci , vol.8 , pp. 337-344
    • Gwiazda, J.1    Thorn, F.2    Bauer, J.3    Held, R.4
  • 3
    • 0000399977 scopus 로고    scopus 로고
    • Animal models of myopia: Learning how vision controls the size of the eye
    • Norton TT. Animal models of myopia: learning how vision controls the size of the eye. ILAR J 1999;40:59-77.
    • (1999) ILAR J , vol.40 , pp. 59-77
    • Norton, T.T.1
  • 5
    • 0026652930 scopus 로고
    • The repeatability of measurement of the ocular components
    • Zadnik K, Mutti DO, Adams AJ. The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 1992;33: 2325-33.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2325-2333
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3
  • 6
    • 0026776531 scopus 로고
    • Repeatability, reproducibility and intersession variability of the Allergan Humphrey ultrasonic biometer
    • Rudnicka AR, Steele CF, Crabb DP, Edgar DF. Repeatability, reproducibility and intersession variability of the Allergan Humphrey ultrasonic biometer. Acta Ophthalmol (Copenh) 1992;70:327-34.
    • (1992) Acta Ophthalmol (Copenh) , vol.70 , pp. 327-334
    • Rudnicka, A.R.1    Steele, C.F.2    Crabb, D.P.3    Edgar, D.F.4
  • 7
    • 0034747904 scopus 로고    scopus 로고
    • The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster
    • Lam AK, Chan R, Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt 2001;21:477-83.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 477-483
    • Lam, A.K.1    Chan, R.2    Pang, P.C.3
  • 8
    • 0031793785 scopus 로고    scopus 로고
    • Could a cycloplegic agent be replaced by a fogging or a corrective lens in the biometric measurement of the crystalline lens?
    • Kee CS, Do TC, Lai RY, Wong G, Lam AK. Could a cycloplegic agent be replaced by a fogging or a corrective lens in the biometric measurement of the crystalline lens? Ophthalmic Physiol Opt 1998; 18:521-6.
    • (1998) Ophthalmic Physiol Opt , vol.18 , pp. 521-526
    • Kee, C.S.1    Do, T.C.2    Lai, R.Y.3    Wong, G.4    Lam, A.K.5
  • 9
    • 0015172626 scopus 로고
    • The sagittal growth of the eye: II. Ultrasonic measurement of the axial diameter of the lens and the anterior segment from birth to puberty
    • Larsen JS. The sagittal growth of the eye: II. Ultrasonic measurement of the axial diameter of the lens and the anterior segment from birth to puberty. Acta Ophthalmol 1971;49:427-40.
    • (1971) Acta Ophthalmol , vol.49 , pp. 427-440
    • Larsen, J.S.1
  • 13
    • 0029818844 scopus 로고    scopus 로고
    • A comparison of slit-lamp supported versus hand-held biometry
    • Whelehan IM, Heyworth P, Tabandeh H, McGuigan S, Foss AJ. A comparison of slit-lamp supported versus hand-held biometry. Eye 1996;10(Pt 4):514-6.
    • (1996) Eye , vol.10 , Issue.PART 4 , pp. 514-516
    • Whelehan, I.M.1    Heyworth, P.2    Tabandeh, H.3    McGuigan, S.4    Foss, A.J.5
  • 14
    • 0034812480 scopus 로고    scopus 로고
    • The Correction of Myopia Evaluation Trial (COMET): Design and general baseline characteristics
    • Hyman L, Gwiazda J, Marsh-Tootle WL, Norton TT, Hussein M. The Correction of Myopia Evaluation Trial (COMET): design and general baseline characteristics. Control Clin Trials 2001;22:573-92.
    • (2001) Control Clin Trials , vol.22 , pp. 573-592
    • Hyman, L.1    Gwiazda, J.2    Marsh-Tootle, W.L.3    Norton, T.T.4    Hussein, M.5
  • 15
    • 0036154525 scopus 로고    scopus 로고
    • Baseline refractive and ocular component measures of children enrolled in the correction of myopia evaluation trial (COMET)
    • Gwiazda J, Marsh-Tootle WL, Hyman L, Hussein M, Norton TT. Baseline refractive and ocular component measures of children enrolled in the correction of myopia evaluation trial (COMET). Invest Ophthalmol Vis Sci 2002;43:314-21.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 314-321
    • Gwiazda, J.1    Marsh-Tootle, W.L.2    Hyman, L.3    Hussein, M.4    Norton, T.T.5
  • 18
    • 0026698174 scopus 로고
    • Effects of different ocular fixation conditions on A-scan ultrasound biometry measurements
    • Steele CF, Crabb DP, Edgar DF. Effects of different ocular fixation conditions on A-scan ultrasound biometry measurements. Ophthalmic Physiol Opt 1992;12:491-5.
    • (1992) Ophthalmic Physiol Opt , vol.12 , pp. 491-495
    • Steele, C.F.1    Crabb, D.P.2    Edgar, D.F.3
  • 20
    • 0021080946 scopus 로고
    • Ultrasound: A research tool in the study of accommodation
    • Storey JK, Rabie EP. Ultrasound: a research tool in the study of accommodation. Ophthalmic Physiol Opt 1983;3:315-20.
    • (1983) Ophthalmic Physiol Opt , vol.3 , pp. 315-320
    • Storey, J.K.1    Rabie, E.P.2
  • 22
    • 0002771774 scopus 로고    scopus 로고
    • Accommodation, the pupil, and presbyopia
    • Benjamin WJ, Borish IM, eds. Philadelphia: WB Saunders
    • Ciuffreda KJ. Accommodation, the pupil, and presbyopia. In: Benjamin WJ, Borish IM, eds. Borish's Clinical Refraction. Philadelphia: WB Saunders, 1998:77-120.
    • (1998) Borish's Clinical Refraction , pp. 77-120
    • Ciuffreda, K.J.1
  • 23
    • 0029870530 scopus 로고    scopus 로고
    • Microfluctuations of steady-state accommodation measured with ultrasonography
    • van der Heijde GL, Beers AP, Dubbelman M. Microfluctuations of steady-state accommodation measured with ultrasonography. Ophthalmic Physiol Opt 1996;16:216-21.
    • (1996) Ophthalmic Physiol Opt , vol.16 , pp. 216-221
    • Van Der Heijde, G.L.1    Beers, A.P.2    Dubbelman, M.3
  • 24
    • 0031017031 scopus 로고    scopus 로고
    • Changes in ocular dimensions and refraction with accommodation
    • Garner LF, Yap MK. Changes in ocular dimensions and refraction with accommodation. Ophthalmic Physiol Opt 1997;17:12-7.
    • (1997) Ophthalmic Physiol Opt , vol.17 , pp. 12-17
    • Garner, L.F.1    Yap, M.K.2
  • 26
    • 0023231559 scopus 로고
    • System for continuous high-resolution measurement of distances in the eye
    • de Vries FR, van der Heijde GL, Goovaerts HG. System for continuous high-resolution measurement of distances in the eye. J Biomed Eng 1987;9:32-7.
    • (1987) J Biomed Eng , vol.9 , pp. 32-37
    • De Vries, F.R.1    Van Der Heijde, G.L.2    Goovaerts, H.G.3
  • 27
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • Hitzenberger CK. Optical measurement of the axial eye length by laser Doppler interferometry. Invest Ophthalmol Vis Sci 1991;32: 616-24.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 28
    • 0000276665 scopus 로고    scopus 로고
    • Measurement by laser Doppler interferometry of intraocular distances in humans and chicks with a precision of better than ±20 μm
    • Schmid GF, Petrig BL Riva CE, Shin KH, Stone RA, Mendel MJ, Laties AM. Measurement by laser Doppler interferometry of intraocular distances in humans and chicks with a precision of better than ±20 μm. Appl Optics 1996;35:3358-61.
    • (1996) Appl Optics , vol.35 , pp. 3358-3361
    • Schmid, G.F.1    Petrig, B.L.2    Riva, C.E.3    Shin, K.H.4    Stone, R.A.5    Mendel, M.J.6    Laties, A.M.7
  • 29
    • 0024248698 scopus 로고
    • Fluctuations in accommodation: A review
    • Charman WN, Heron G. Fluctuations in accommodation: a review. Ophthalmic Physiol Opt 1988;8:153-64.
    • (1988) Ophthalmic Physiol Opt , vol.8 , pp. 153-164
    • Charman, W.N.1    Heron, G.2
  • 30


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.