Volumn 82, Issue 9, 2005, Pages 858-861

Validity and repeatability of anterior chamber depth measurements with pentacam and orbscan

Author keywords

Anterior chamber depth; Biometry; Comparative study; Observer variability; Scheimpflug imaging

Indexed keywords

MEDICAL APPLICATIONS; MEDICAL IMAGING; MEDICAL PROBLEMS; PATIENT TREATMENT; VISION;

EID: 25644448981     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.opx.0000177804.53192.15     Document Type: Article
Times cited : (135)

References (20)
  • 1
    • 0034750896 scopus 로고    scopus 로고
    • Multicenter biometry study of 1 pair of eyes
    • Norrby S. Multicenter biometry study of 1 pair of eyes. J Cataract Refract Surg 2001;27:1656-61.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1656-1661
    • Norrby, S.1
  • 2
    • 0026652930 scopus 로고
    • The repeatability of measurement of the ocular components
    • Zadnik K, Mutti DO, Adams AJ. The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 1992;33: 2325-33.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2325-2333
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3
  • 3
    • 0025336954 scopus 로고
    • Comparison of A-scan device accuracy
    • Giers U, Epple C. Comparison of A-scan device accuracy. J Cataract Refract Surg 1990;16:235-42.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 235-242
    • Giers, U.1    Epple, C.2
  • 5
    • 0030817812 scopus 로고    scopus 로고
    • Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations
    • Holladay JT. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg 1997;23:1356-70.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1356-1370
    • Holladay, J.T.1
  • 6
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 1992;18:125-9.
    • (1992) J Cataract Refract Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 7
    • 8544229101 scopus 로고    scopus 로고
    • Comparison of the optical coherence method (Zeiss IOL-Master) with two ultrasonographic biometric methods for the calculation of posterior chamber intraocular lenses after phacoemulsification as part of clinical routine
    • Remsch H, Kampmeier J, Muche R, Lang GE, Lang GK. [Comparison of the optical coherence method (Zeiss IOL-Master) with two ultrasonographic biometric methods for the calculation of posterior chamber intraocular lenses after phacoemulsification as part of clinical routine.] Klin Monatsbl Augenheilkd 2004;221:837-42.
    • (2004) Klin Monatsbl Augenheilkd , vol.221 , pp. 837-842
    • Remsch, H.1    Kampmeier, J.2    Muche, R.3    Lang, G.E.4    Lang, G.K.5
  • 10
    • 0029038603 scopus 로고
    • Comparing two methods of clinical measurement: A personal history
    • Bland JM, Altman DG. Comparing two methods of clinical measurement: a personal history. Int J Epidemiol 1995;24(suppl 1): S7-14.
    • (1995) Int J Epidemiol , vol.24 , Issue.SUPPL. 1
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, AJtman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Ajtman, D.G.2
  • 12
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0025315983 scopus 로고
    • Development of the SRK/T intraocular lens implant power calculation formula
    • Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 1990;16:333-40.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 333-340
    • Retzlaff, J.A.1    Sanders, D.R.2    Kraff, M.C.3
  • 16
    • 0036169561 scopus 로고    scopus 로고
    • Anterior chamber depth measurement: A-scan versus optical methods
    • Koranyi G, Lydahl E, Norrby S, Taube M. Anterior chamber depth measurement: a-scan versus optical methods. J Cataract Refract Surg 2002;28;243-7.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 243-247
    • Koranyi, G.1    Lydahl, E.2    Norrby, S.3    Taube, M.4
  • 17
    • 0033820671 scopus 로고    scopus 로고
    • Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant
    • Vetrugno M, Cardascia N, Cardia L. Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant. Br J Ophthalmol 2000;84:1113-6.
    • (2000) Br J Ophthalmol , vol.84 , pp. 1113-1116
    • Vetrugno, M.1    Cardascia, N.2    Cardia, L.3
  • 19
    • 2942538426 scopus 로고    scopus 로고
    • Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOL Master
    • Reddy AR, Pande MV, Finn P, El-Gogary H. Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOL Master. J Cataract Refract Surg 2004;30:1268-71.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1268-1271
    • Reddy, A.R.1    Pande, M.V.2    Finn, P.3    El-Gogary, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.