-
1
-
-
11244326217
-
-
International Standards Organization. ISO8612:2001(E), Geneva, Switzerland: ISO Copyright Office
-
International Standards Organization. ISO8612:2001(E): Ophthalmic Instruments-Tonometers. Geneva, Switzerland: ISO Copyright Office; 2001.
-
(2001)
Ophthalmic Instruments-Tonometers
-
-
-
2
-
-
0034603359
-
Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
-
Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
-
(2000)
Surv Ophthalmol.
, vol.44
, pp. 367-408
-
-
Doughty, M.J.1
Zaman, M.L.2
-
3
-
-
0030963090
-
Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study
-
Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol. 1997;123:767-772.
-
(1997)
Am J Ophthalmol.
, vol.123
, pp. 767-772
-
-
Wolfs, R.C.1
Klaver, C.C.2
Vingerling, J.R.3
Grobbee, D.E.4
Hofman, A.5
de Jong, P.T.6
-
4
-
-
0027269723
-
The effect of corneal thickness on applanation tonometry
-
Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592-596.
-
(1993)
Am J Ophthalmol.
, vol.115
, pp. 592-596
-
-
Whitacre, M.M.1
Stein, R.A.2
Hassanein, K.3
-
6
-
-
33748924156
-
Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer
-
Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006;15:364-370.
-
(2006)
J Glaucoma.
, vol.15
, pp. 364-370
-
-
Medeiros, F.A.1
Weinreb, R.N.2
-
7
-
-
0015878930
-
Corneal curvature in applanation tonometry
-
Mark HH. Corneal curvature in applanation tonometry. Am J Ophthalmol. 1973;76:223-224.
-
(1973)
Am J Ophthalmol.
, vol.76
, pp. 223-224
-
-
Mark, H.H.1
-
8
-
-
77955367199
-
Role of corneal biomechanical properties in applanation tonometry measurements
-
Kwon TH, Ghaboussi J, Pecknold DA, Hashash YM. Role of corneal biomechanical properties in applanation tonometry measurements. J Refract Surg. 2010;26:512-519.
-
(2010)
J Refract Surg.
, vol.26
, pp. 512-519
-
-
Kwon, T.H.1
Ghaboussi, J.2
Pecknold, D.A.3
Hashash, Y.M.4
-
9
-
-
43749092192
-
Effect of cornea material stiffness on measured intraocular pressure
-
Kwon TH, Ghaboussi J, Pecknold DA, Hashash YM. Effect of cornea material stiffness on measured intraocular pressure. J Biomech. 2008;41:1707-1713.
-
(2008)
J Biomech.
, vol.41
, pp. 1707-1713
-
-
Kwon, T.H.1
Ghaboussi, J.2
Pecknold, D.A.3
Hashash, Y.M.4
-
10
-
-
48549092622
-
Young's modulus in normal corneas and the effect on applanation tonometry
-
Hamilton KE, Pye DC. Young's modulus in normal corneas and the effect on applanation tonometry. Optom Vis Sci. 2008;85:445-450.
-
(2008)
Optom Vis Sci.
, vol.85
, pp. 445-450
-
-
Hamilton, K.E.1
Pye, D.C.2
-
11
-
-
33847051527
-
Evaluation of Goldmann applanation tonometry using a nonlinear finite element ocular model
-
Elsheikh A, Wang D, Kotecha A, Brown M, Garway-Heath D. Evaluation of Goldmann applanation tonometry using a nonlinear finite element ocular model. Ann Biomed Eng. 2006;34:1628-1640.
-
(2006)
Ann Biomed Eng.
, vol.34
, pp. 1628-1640
-
-
Elsheikh, A.1
Wang, D.2
Kotecha, A.3
Brown, M.4
Garway-Heath, D.5
-
12
-
-
13844313434
-
Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
-
Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146-155.
-
(2005)
J Cataract Refract Surg.
, vol.31
, pp. 146-155
-
-
Liu, J.1
Roberts, C.J.2
-
13
-
-
0027411731
-
Effect of corneal hydration on Goldmann applanation tonometry and corneal topography
-
Simon G, Small RH, Ren Q, Parel JM. Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. Refract Corneal Surg. 1993;9:110-117.
-
(1993)
Refract Corneal Surg.
, vol.9
, pp. 110-117
-
-
Simon, G.1
Small, R.H.2
Ren, Q.3
Parel, J.M.4
-
14
-
-
0016788858
-
Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas
-
McMillan F, Forster RK. Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas. Arch Ophthalmol. 1975;93:420-424.
-
(1975)
Arch Ophthalmol.
, vol.93
, pp. 420-424
-
-
McMillan, F.1
Forster, R.K.2
-
15
-
-
0001534165
-
The Goldmann applanation tonometer
-
Moses RA. The Goldmann applanation tonometer. Am J Ophthalmol. 1958;46:865-869.
-
(1958)
Am J Ophthalmol.
, vol.46
, pp. 865-869
-
-
Moses, R.A.1
-
16
-
-
48549088682
-
The effect of corneal edema on dynamic contour and Goldmann tonometry
-
Hamilton KE, Pye DC, Kao L, Pham N, Tran AQ. The effect of corneal edema on dynamic contour and Goldmann tonometry. Optom Vis Sci. 2008;85:451-456.
-
(2008)
Optom Vis Sci.
, vol.85
, pp. 451-456
-
-
Hamilton, K.E.1
Pye, D.C.2
Kao, L.3
Pham, N.4
Tran, A.Q.5
-
17
-
-
33947431052
-
Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure
-
Lu F, Xu S, Qu J, et al. Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure. Am J Ophthalmol. 2007;143:616-622.
-
(2007)
Am J Ophthalmol.
, vol.143
, pp. 616-622
-
-
Lu, F.1
Xu, S.2
Qu, J.3
et al4
-
18
-
-
33846304686
-
The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements
-
Hamilton KE, Pye DC, Hali A, Lin C, Kam P, Ngyuen T. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements. J Glaucoma. 2007;16:153-158.
-
(2007)
J Glaucoma.
, vol.16
, pp. 153-158
-
-
Hamilton, K.E.1
Pye, D.C.2
Hali, A.3
Lin, C.4
Kam, P.5
Ngyuen, T.6
-
19
-
-
36749025231
-
The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population
-
Hamilton K, Pye D, Hua S, Yu F, Chung J, Hou Q. The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population. Br J Ophthalmol. 2007;91: 1636-1638.
-
(2007)
Br J Ophthalmol.
, vol.91
, pp. 1636-1638
-
-
Hamilton, K.1
Pye, D.2
Hua, S.3
Yu, F.4
Chung, J.5
Hou, Q.6
-
20
-
-
59749092485
-
The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry
-
Oh JH, Yoo C, Kim YY, Kim HM, Song JS. The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry. Graefes Arch Clin Exp Ophthalmol. 2009;247:371-375.
-
(2009)
Graefes Arch Clin Exp Ophthalmol.
, vol.247
, pp. 371-375
-
-
Oh, J.H.1
Yoo, C.2
Kim, Y.Y.3
Kim, H.M.4
Song, J.S.5
-
21
-
-
13844317411
-
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
-
Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156-162.
-
(2005)
J Cataract Refract Surg.
, vol.31
, pp. 156-162
-
-
Luce, D.A.1
-
23
-
-
48549094493
-
Ocular Response Analyzer in subjects with and without glaucoma
-
Sullivan-Mee M, Billingsley SC, Patel AD, Halverson KD, Alldredge BR, Qualls C. Ocular Response Analyzer in subjects with and without glaucoma. Optom Vis Sci. 2008;85:463-470.
-
(2008)
Optom Vis Sci.
, vol.85
, pp. 463-470
-
-
Sullivan-Mee, M.1
Billingsley, S.C.2
Patel, A.D.3
Halverson, K.D.4
Alldredge, B.R.5
Qualls, C.6
-
24
-
-
33646190149
-
Central corneal thickness and corneal hysteresis associated with glaucoma damage
-
Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006;141:868-875.
-
(2006)
Am J Ophthalmol.
, vol.141
, pp. 868-875
-
-
Congdon, N.G.1
Broman, A.T.2
Bandeen-Roche, K.3
Grover, D.4
Quigley, H.A.5
-
25
-
-
77951236487
-
Corneal biomechanics, refraction, and corneal aberrometry in keratoconus: An integrated study
-
Pinero DP, Alio JL, Barraquer RI, Michael R, Jimenez R. Corneal biomechanics, refraction, and corneal aberrometry in keratoconus: an integrated study. Invest Ophthalmol Vis Sci. 2010;51:1948-1955.
-
(2010)
Invest Ophthalmol Vis Sci.
, vol.51
, pp. 1948-1955
-
-
Pinero, D.P.1
Alio, J.L.2
Barraquer, R.I.3
Michael, R.4
Jimenez, R.5
-
26
-
-
34548022426
-
Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
-
Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci. 2007;48:3026-3031.
-
(2007)
Invest Ophthalmol Vis Sci.
, vol.48
, pp. 3026-3031
-
-
Shah, S.1
Laiquzzaman, M.2
Bhojwani, R.3
Mantry, S.4
Cunliffe, I.5
-
27
-
-
55849111550
-
Corneal biomechanical measurements before and after laser in situ keratomileusis
-
Chen MC, Lee N, Bourla N, Hamilton DR. Corneal biomechanical measurements before and after laser in situ keratomileusis. J Cataract Refract Surg. 2008;34:1886-1891.
-
(2008)
J Cataract Refract Surg.
, vol.34
, pp. 1886-1891
-
-
Chen, M.C.1
Lee, N.2
Bourla, N.3
Hamilton, D.R.4
-
28
-
-
33845499055
-
Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
-
Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143:39-47.
-
(2007)
Am J Ophthalmol.
, vol.143
, pp. 39-47
-
-
Pepose, J.S.1
Feigenbaum, S.K.2
Qazi, M.A.3
Sanderson, J.P.4
Roberts, C.J.5
-
29
-
-
0037378859
-
Diurnal variation of corneal sensitivity and thickness
-
du Toit R, Vega JA, Fonn D, Simpson T. Diurnal variation of corneal sensitivity and thickness. Cornea. 2003;22:205-209.
-
(2003)
Cornea.
, vol.22
, pp. 205-209
-
-
du Toit, R.1
Vega, J.A.2
Fonn, D.3
Simpson, T.4
-
30
-
-
0020660052
-
Corneal swelling response to contact lenses worn under extended wear conditions
-
Holden BA, Mertz GW, McNally JJ. Corneal swelling response to contact lenses worn under extended wear conditions. Invest Ophthalmol Vis Sci. 1983;24:218-226.
-
(1983)
Invest Ophthalmol Vis Sci.
, vol.24
, pp. 218-226
-
-
Holden, B.A.1
Mertz, G.W.2
McNally, J.J.3
-
31
-
-
0013850022
-
Thinning of the human cornea on awakening
-
Mandell RB, Fatt I. Thinning of the human cornea on awakening. Nature. 1965;208:292-293.
-
(1965)
Nature.
, vol.208
, pp. 292-293
-
-
Mandell, R.B.1
Fatt, I.2
-
33
-
-
0030596840
-
Measurement error
-
Bland JM, Altman DG. Measurement error. BMJ. 1996;313:744.
-
(1996)
BMJ.
, vol.313
, pp. 744
-
-
Bland, J.M.1
Altman, D.G.2
-
34
-
-
0030026336
-
Standardizing the measurement of intraocular pressure for clinical research: Guidelines from the Eye Care Technology Forum
-
Kass MA. Standardizing the measurement of intraocular pressure for clinical research: guidelines from the Eye Care Technology Forum. Ophthalmology. 1996;103:183-185.
-
(1996)
Ophthalmology.
, vol.103
, pp. 183-185
-
-
Kass, M.A.1
-
35
-
-
34547145165
-
G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
-
Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175-191.
-
(2007)
Behav Res Methods.
, vol.39
, pp. 175-191
-
-
Faul, F.1
Erdfelder, E.2
Lang, A.G.3
Buchner, A.4
-
37
-
-
0021123317
-
Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
-
Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci. 1984;25:1161-1167.
-
(1984)
Invest Ophthalmol Vis Sci.
, vol.25
, pp. 1161-1167
-
-
Holden, B.A.1
Mertz, G.W.2
-
38
-
-
0000142466
-
Importance of atmospheric oxygen for maintenance of the optical properties of the human cornea
-
Smelser GK, Ozanics V. Importance of atmospheric oxygen for maintenance of the optical properties of the human cornea. Science. 1952;115:140-141.
-
(1952)
Science.
, vol.115
, pp. 140-141
-
-
Smelser, G.K.1
Ozanics, V.2
-
39
-
-
70449527662
-
Investigation of posterior corneal curvature in CL-induced corneal swelling
-
Martin R, Izquierdo M, Saber A. Investigation of posterior corneal curvature in CL-induced corneal swelling. Cont Lens Anterior Eye. 2009;32:288-293.
-
(2009)
Cont Lens Anterior Eye.
, vol.32
, pp. 288-293
-
-
Martin, R.1
Izquierdo, M.2
Saber, A.3
-
40
-
-
0014861448
-
Uneven swelling of the corneal stroma
-
Kikkawa Y, Hirayama K. Uneven swelling of the corneal stroma. Invest Ophthalmol. 1970;9:735-741.
-
(1970)
Invest Ophthalmol.
, vol.9
, pp. 735-741
-
-
Kikkawa, Y.1
Hirayama, K.2
-
41
-
-
47249138174
-
Dynamic contour tonometry in comparison to intracameral IOP measurements
-
Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E. Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008;49:2472-2477.
-
(2008)
Invest Ophthalmol Vis Sci.
, vol.49
, pp. 2472-2477
-
-
Boehm, A.G.1
Weber, A.2
Pillunat, L.E.3
Koch, R.4
Spoerl, E.5
-
42
-
-
27744519845
-
Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
-
Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol. 2005;123:1532-1537.
-
(2005)
Arch Ophthalmol.
, vol.123
, pp. 1532-1537
-
-
Kniestedt, C.1
Lin, S.2
Choe, J.3
Bostrom, A.4
Nee, M.5
Stamper, R.L.6
-
43
-
-
25644460363
-
Dynamic contour tonometry: Presentation of a new tonometer
-
Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma. 2005; 14:344-350.
-
(2005)
J Glaucoma.
, vol.14
, pp. 344-350
-
-
Kanngiesser, H.E.1
Kniestedt, C.2
Robert, Y.C.3
-
44
-
-
67349112996
-
Effect of corneal hydration on ultrasound velocity and backscatter
-
Silverman RH, Patel MS, Gal O, et al. Effect of corneal hydration on ultrasound velocity and backscatter. Ultrasound Med Biol. 2009; 35:839-846.
-
(2009)
Ultrasound Med Biol.
, vol.35
, pp. 839-846
-
-
Silverman, R.H.1
Patel, M.S.2
Gal, O.3
et al4
-
45
-
-
13844317405
-
Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgery
-
Jaycock PD, Lobo L, Ibrahim J, Tyrer J, Marshall J. Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgery. J Cataract Refract Surg. 2005;31: 175-184.
-
(2005)
J Cataract Refract Surg.
, vol.31
, pp. 175-184
-
-
Jaycock, P.D.1
Lobo, L.2
Ibrahim, J.3
Tyrer, J.4
Marshall, J.5
-
46
-
-
13844310359
-
Dynamic corneal imaging
-
Grabner G, Eilmsteiner R, Steindl C, Ruckhofer J, Mattioli R, Husinsky W. Dynamic corneal imaging. J Cataract Refract Surg. 2005; 31:163-174.
-
(2005)
J Cataract Refract Surg.
, vol.31
, pp. 163-174
-
-
Grabner, G.1
Eilmsteiner, R.2
Steindl, C.3
Ruckhofer, J.4
Mattioli, R.5
Husinsky, W.6
-
47
-
-
77953801568
-
A quantitative ultrasonic spectroscopy method for noninvasive determination of corneal biomechanical properties
-
He X, Liu J. A quantitative ultrasonic spectroscopy method for noninvasive determination of corneal biomechanical properties. Invest Ophthalmol Vis Sci. 2009;50:5148-5154.
-
(2009)
Invest Ophthalmol Vis Sci.
, vol.50
, pp. 5148-5154
-
-
He, X.1
Liu, J.2
-
49
-
-
0036132931
-
Strain imaging of corneal tissue with an ultrasound elasticity microscope
-
Hollman KW, Emelianov SY, Neiss JH, et al. Strain imaging of corneal tissue with an ultrasound elasticity microscope. Cornea. 2002;21:68-73.
-
(2002)
Cornea.
, vol.21
, pp. 68-73
-
-
Hollman, K.W.1
Emelianov, S.Y.2
Neiss, J.H.3
et al4
-
50
-
-
67649967924
-
Biomechanical properties of the cornea in Fuchs' corneal dystrophy
-
del Buey MA, Cristobal JA, Ascaso FJ, Lavilla L, Lanchares E. Biomechanical properties of the cornea in Fuchs' corneal dystrophy. Invest Ophthalmol Vis Sci. 2009;50:3199-3202.
-
(2009)
Invest Ophthalmol Vis Sci.
, vol.50
, pp. 3199-3202
-
-
del Buey, M.A.1
Cristobal, J.A.2
Ascaso, F.J.3
Lavilla, L.4
Lanchares, E.5
-
51
-
-
0029166361
-
Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetics
-
Skaff A, Cullen AP, Doughty MJ, Fonn D. Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetics. Ophthalmic Physiol Opt. 1995;15:287-297.
-
(1995)
Ophthalmic Physiol Opt.
, vol.15
, pp. 287-297
-
-
Skaff, A.1
Cullen, A.P.2
Doughty, M.J.3
Fonn, D.4
-
52
-
-
78049257366
-
Corneal biomechanical characteristics in patients with diabetes mellitus
-
Kotecha A, Oddone F, Sinapis C, et al. Corneal biomechanical characteristics in patients with diabetes mellitus. J Cataract Refract Surg. 2010;36:1822-1828.
-
(2010)
J Cataract Refract Surg.
, vol.36
, pp. 1822-1828
-
-
Kotecha, A.1
Oddone, F.2
Sinapis, C.3
et al4
-
53
-
-
70349572803
-
Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements
-
Sahin A, Bayer A, Ozge G, Mumcuoglu T. Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements. Invest Ophthalmol Vis Sci. 2009;50: 4597-4604.
-
(2009)
Invest Ophthalmol Vis Sci.
, vol.50
, pp. 4597-4604
-
-
Sahin, A.1
Bayer, A.2
Ozge, G.3
Mumcuoglu, T.4
-
54
-
-
62649160370
-
Effect of diabetes mellitus on biomechanical parameters of the cornea
-
Goldich Y, Barkana Y, Gerber Y, et al. Effect of diabetes mellitus on biomechanical parameters of the cornea. J Cataract Refract Surg. 2009;35:715-719.
-
(2009)
J Cataract Refract Surg.
, vol.35
, pp. 715-719
-
-
Goldich, Y.1
Barkana, Y.2
Gerber, Y.3
et al4
-
55
-
-
0141775088
-
Transparency, swelling and scarring in the corneal stroma
-
Meek KM, Leonard DW, Connon CJ, Dennis S, Khan S. Transparency, swelling and scarring in the corneal stroma. Eye. 2003;17: 927-936.
-
(2003)
Eye.
, vol.17
, pp. 927-936
-
-
Meek, K.M.1
Leonard, D.W.2
Connon, C.J.3
Dennis, S.4
Khan, S.5
|