메뉴 건너뛰기




Volumn 23, Issue 1, 2007, Pages 66-75

Surface wave elastometry of the cornea in porcine and human donor eyes

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN;

EID: 33846326496     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20070101-11     Document Type: Article
Times cited : (73)

References (55)
  • 1
    • 0036910912 scopus 로고    scopus 로고
    • Progressive post-LASIK keratectasia: Biomechanical instability or chronic disease process?
    • Comaish IF, Lawless MA. Progressive post-LASIK keratectasia: biomechanical instability or chronic disease process? J Cataract Refract Surg. 2002;28:2206-2213.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 2206-2213
    • Comaish, I.F.1    Lawless, M.A.2
  • 2
    • 15544363415 scopus 로고    scopus 로고
    • Biomechanical modeling of corneal ectasia
    • Dupps WJ, Jr. Biomechanical modeling of corneal ectasia. J Refract Surg. 2005;21:186-190.
    • (2005) J Refract Surg , vol.21 , pp. 186-190
    • Dupps Jr., W.J.1
  • 3
    • 0001063063 scopus 로고
    • Contribution to the theory and practice of tonometry
    • Friedenwald JS. Contribution to the theory and practice of tonometry. Am J Ophthalmol. 1937;20:985-1024.
    • (1937) Am J Ophthalmol , vol.20 , pp. 985-1024
    • Friedenwald, J.S.1
  • 4
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
    • Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146-155.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 5
    • 0014286175 scopus 로고
    • The tensile strength of corneal wounds
    • Gasset AR, Dohlman CH. The tensile strength of corneal wounds. Arch Ophthalmol. 1968;79:595-602.
    • (1968) Arch Ophthalmol , vol.79 , pp. 595-602
    • Gasset, A.R.1    Dohlman, C.H.2
  • 6
    • 13844317424 scopus 로고    scopus 로고
    • Corneal power, thickness, and stiffness: Results of a prospective randomized controlled trial of PRK and LASIK for myopia
    • Hjortdal JO, Moller-Pedersen T, Ivarsen A, Ehlers N. Corneal power, thickness, and stiffness: results of a prospective randomized controlled trial of PRK and LASIK for myopia. J Cataract Refract Surg. 2005;31:21-29.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 21-29
    • Hjortdal, J.O.1    Moller-Pedersen, T.2    Ivarsen, A.3    Ehlers, N.4
  • 8
    • 0043013300 scopus 로고    scopus 로고
    • Biomechanical and optical characteristics of a corneal stromal equivalent
    • Orwin EJ, Borene ML, Hubel A. Biomechanical and optical characteristics of a corneal stromal equivalent. J Biomech Eng. 2003;125:439-444.
    • (2003) J Biomech Eng , vol.125 , pp. 439-444
    • Orwin, E.J.1    Borene, M.L.2    Hubel, A.3
  • 9
    • 0035192810 scopus 로고    scopus 로고
    • Effect of acute biomechanical changes on corneal curvature after photokeratectomy
    • Dupps WJ Jr, Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg. 2001;17:658-669.
    • (2001) J Refract Surg , vol.17 , pp. 658-669
    • Dupps Jr, W.J.1    Roberts, C.2
  • 10
    • 0033898907 scopus 로고    scopus 로고
    • The cornea is not a piece of plastic
    • Roberts C. The cornea is not a piece of plastic. J Refract Surg. 2000;16:407-413.
    • (2000) J Refract Surg , vol.16 , pp. 407-413
    • Roberts, C.1
  • 11
    • 0036745768 scopus 로고    scopus 로고
    • Biomechanical response of the cornea to phototherapeutic keratectomy when treated as a fluid-filled porous material
    • Katsube N, Wang R, Okuma E, Roberts C. Biomechanical response of the cornea to phototherapeutic keratectomy when treated as a fluid-filled porous material. J Refract Surg. 2002;18:S593-S597.
    • (2002) J Refract Surg , vol.18
    • Katsube, N.1    Wang, R.2    Okuma, E.3    Roberts, C.4
  • 12
    • 15544373161 scopus 로고    scopus 로고
    • Theoretical elastic response of the cornea to refractive surgery: Risk factors for keratectasia
    • Guirao A. Theoretical elastic response of the cornea to refractive surgery: risk factors for keratectasia. J Refract Surg. 2005;21:176-185.
    • (2005) J Refract Surg , vol.21 , pp. 176-185
    • Guirao, A.1
  • 13
    • 0024381898 scopus 로고
    • Preliminary computer simulation of the effects of radial keratotomy
    • Hanna KD, Jouve FE, Waring GO III. Preliminary computer simulation of the effects of radial keratotomy. Arch Ophthalmol. 1989;107:911-918.
    • (1989) Arch Ophthalmol , vol.107 , pp. 911-918
    • Hanna, K.D.1    Jouve, F.E.2    Waring III, G.O.3
  • 14
    • 0024852388 scopus 로고
    • Computer simulation of arcuate and radial incisions involving the corneo-scleral limbus
    • Hanna KD, Jouve FE, Waring GO III, Ciarlet PG. Computer simulation of arcuate and radial incisions involving the corneo-scleral limbus. Eye. 1989;3:227-239.
    • (1989) Eye , vol.3 , pp. 227-239
    • Hanna, K.D.1    Jouve, F.E.2    Waring III, G.O.3    Ciarlet, P.G.4
  • 15
    • 0024821025 scopus 로고
    • A mechanical model of the cornea: The effects of physiological and surgical factors on radial keratotomy surgery
    • Vito RP, Shin TJ, McCarey BE. A mechanical model of the cornea: the effects of physiological and surgical factors on radial keratotomy surgery. Refract Corneal Surg. 1989;5:82-88.
    • (1989) Refract Corneal Surg , vol.5 , pp. 82-88
    • Vito, R.P.1    Shin, T.J.2    McCarey, B.E.3
  • 16
    • 0025785926 scopus 로고
    • A microstructurally-based finite element model of the incised human cornea
    • Pinsky PM, Datye DV. A microstructurally-based finite element model of the incised human cornea. J Biomech. 1991;24:907-922.
    • (1991) J Biomech , vol.24 , pp. 907-922
    • Pinsky, P.M.1    Datye, D.V.2
  • 17
    • 0026734661 scopus 로고
    • Numerical modeling of radial, astigmatic, and hexagonal keratotomy
    • Pinsky PM, Datye DV. Numerical modeling of radial, astigmatic, and hexagonal keratotomy. Refract Corneal Surg. 1992;8:164-172.
    • (1992) Refract Corneal Surg , vol.8 , pp. 164-172
    • Pinsky, P.M.1    Datye, D.V.2
  • 19
    • 0026717529 scopus 로고
    • Finite element based mechanical models of the cornea for pressure and indenter loading
    • Vito RP, Carnell PH. Finite element based mechanical models of the cornea for pressure and indenter loading. Refract Corneal Surg. 1992;8:146-151.
    • (1992) Refract Corneal Surg , vol.8 , pp. 146-151
    • Vito, R.P.1    Carnell, P.H.2
  • 20
    • 33747150017 scopus 로고    scopus 로고
    • Application of structural analysis to the behaviour of the cornea
    • Anderson K, El-Sheikh A, Newson T. Application of structural analysis to the behaviour of the cornea. J R Soc Interface. 2004;1:3-15.
    • (2004) J R Soc Interface , vol.1 , pp. 3-15
    • Anderson, K.1    El-Sheikh, A.2    Newson, T.3
  • 21
    • 0030297968 scopus 로고    scopus 로고
    • Constitutive laws for biomechanical modeling of refractive surgery
    • Bryant MR, McDonnell PJ. Constitutive laws for biomechanical modeling of refractive surgery. J Biomech Eng. 1996;118:473-481.
    • (1996) J Biomech Eng , vol.118 , pp. 473-481
    • Bryant, M.R.1    McDonnell, P.J.2
  • 22
    • 0020957167 scopus 로고
    • The dynamic mechanical properties of human skin in vivo
    • Potts RO, Chrisman DA Jr, Buras EM Jr. The dynamic mechanical properties of human skin in vivo. J Biomech. 1983;16:365-372.
    • (1983) J Biomech , vol.16 , pp. 365-372
    • Potts, R.O.1    Chrisman Jr, D.A.2    Buras Jr., E.M.3
  • 24
    • 0032734061 scopus 로고    scopus 로고
    • Evaluation of skin viscoelasticity and anisotropy by measurement of speed of shear wave propagation with viscoelasticity skin analyzer
    • Vexler A, Polyansky I, Gorodetsky R. Evaluation of skin viscoelasticity and anisotropy by measurement of speed of shear wave propagation with viscoelasticity skin analyzer. J Invest Dermatol. 1999;113:732-739.
    • (1999) J Invest Dermatol , vol.113 , pp. 732-739
    • Vexler, A.1    Polyansky, I.2    Gorodetsky, R.3
  • 25
    • 0027198026 scopus 로고
    • Interlamellar cohesive strength in the vertical meridian of human eye bank corneas
    • Smolek MK. Interlamellar cohesive strength in the vertical meridian of human eye bank corneas. Invest Ophthalmol Vis Sci. 1993;34:2962-2969.
    • (1993) Invest Ophthalmol Vis Sci , vol.34 , pp. 2962-2969
    • Smolek, M.K.1
  • 26
    • 0025288715 scopus 로고
    • Interlamellar adhesive strength in human eyebank corneas
    • Smolek MK, McCarey BE. Interlamellar adhesive strength in human eyebank corneas. Invest Ophthalmol Vis Sci. 1990;31:1087-1095.
    • (1990) Invest Ophthalmol Vis Sci , vol.31 , pp. 1087-1095
    • Smolek, M.K.1    McCarey, B.E.2
  • 27
    • 0032753161 scopus 로고    scopus 로고
    • Organization of collagen fibrils in the corneal stroma in relation to mechanical properties and surgical practice
    • Meek KM, Newton RH. Organization of collagen fibrils in the corneal stroma in relation to mechanical properties and surgical practice. J Refract Surg. 1999;15:695-699.
    • (1999) J Refract Surg , vol.15 , pp. 695-699
    • Meek, K.M.1    Newton, R.H.2
  • 28
    • 0026002067 scopus 로고
    • The three-dimensional organization of collagen fibrils in the human cornea and sclera
    • Komai Y, Ushiki T. The three-dimensional organization of collagen fibrils in the human cornea and sclera. Invest Ophthalmol Vis Sci. 1991;32:2244-2258.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 2244-2258
    • Komai, Y.1    Ushiki, T.2
  • 29
    • 0031941909 scopus 로고    scopus 로고
    • Induction of cross-links in corneal tissue
    • Spoerl E, Huhle M, Seiler T. Induction of cross-links in corneal tissue. Exp Eye Res. 1998;66:97-103.
    • (1998) Exp Eye Res , vol.66 , pp. 97-103
    • Spoerl, E.1    Huhle, M.2    Seiler, T.3
  • 31
    • 0030561003 scopus 로고    scopus 로고
    • An ultrasonic technique for the measurement of the elastic moduli of human cornea
    • Wang H, Prendiville PL, McDonnell PJ, Chang WV. An ultrasonic technique for the measurement of the elastic moduli of human cornea. J Biomech. 1996;29:1633-1636.
    • (1996) J Biomech , vol.29 , pp. 1633-1636
    • Wang, H.1    Prendiville, P.L.2    McDonnell, P.J.3    Chang, W.V.4
  • 34
    • 0026939402 scopus 로고
    • Mechanical pulse wave propagation in gel, normal and oedematous tissues
    • Mridha M, Odman S, Oberg PA. Mechanical pulse wave propagation in gel, normal and oedematous tissues. J Biomech. 1992;25:1213-1218.
    • (1992) J Biomech , vol.25 , pp. 1213-1218
    • Mridha, M.1    Odman, S.2    Oberg, P.A.3
  • 35
    • 0025144363 scopus 로고
    • Analysis of shear wave propagation in skin; application to an experimental procedure
    • Pereira JM, Mansour JM, Davis BR. Analysis of shear wave propagation in skin; application to an experimental procedure. J Biomech. 1990;23:745-751.
    • (1990) J Biomech , vol.23 , pp. 745-751
    • Pereira, J.M.1    Mansour, J.M.2    Davis, B.R.3
  • 36
    • 0035058423 scopus 로고    scopus 로고
    • Influence of body posture and gravitational forces on shear wave propagation in the skin
    • Nizet JL, Pierard-Franchimont C, Pierard GE. Influence of body posture and gravitational forces on shear wave propagation in the skin. Dermatology. 2001;202:177-180.
    • (2001) Dermatology , vol.202 , pp. 177-180
    • Nizet, J.L.1    Pierard-Franchimont, C.2    Pierard, G.E.3
  • 40
    • 0025314350 scopus 로고
    • Astigmatic keratotomy: A review of basic concepts with case reports
    • Thornton SP. Astigmatic keratotomy: a review of basic concepts with case reports. J Cataract Refract Surg. 1990;16:430-435.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 430-435
    • Thornton, S.P.1
  • 41
    • 0023790106 scopus 로고
    • Paired arcuate keratotomy. A surgical approach to mixed and myopic astigmatism
    • Duffey RJ, Jain VN, Tchah H, Hofmann RE, Lindstrom RL. Paired arcuate keratotomy. A surgical approach to mixed and myopic astigmatism. Arch Ophthalmol. 1988;106:1130-1135.
    • (1988) Arch Ophthalmol , vol.106 , pp. 1130-1135
    • Duffey, R.J.1    Jain, V.N.2    Tchah, H.3    Hofmann, R.E.4    Lindstrom, R.L.5
  • 42
    • 0034114509 scopus 로고    scopus 로고
    • Thermal and biomechanical parameters of porcine cornea
    • Kampmeier J, Radt B, Birngruber R, Brinkmann R. Thermal and biomechanical parameters of porcine cornea. Cornea. 2000;19:355-363.
    • (2000) Cornea , vol.19 , pp. 355-363
    • Kampmeier, J.1    Radt, B.2    Birngruber, R.3    Brinkmann, R.4
  • 43
    • 0036744718 scopus 로고    scopus 로고
    • Biomechanics of the cornea and wavefront-guided laser refractive surgery
    • Roberts C. Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg. 2002;18:S589-S592.
    • (2002) J Refract Surg , vol.18
    • Roberts, C.1
  • 44
    • 33846275611 scopus 로고    scopus 로고
    • Regional stiffness of human donor corneas measured by sonic wave elastometry
    • E-abstract 1335
    • Dupps WJ, Krueger RR, Jeng BH. Regional stiffness of human donor corneas measured by sonic wave elastometry. Invest Ophthalmol Vis Sci. 2006;47:E-abstract 1335.
    • (2006) Invest Ophthalmol Vis Sci , pp. 47
    • Dupps, W.J.1    Krueger, R.R.2    Jeng, B.H.3
  • 45
    • 0027411731 scopus 로고
    • Effect of corneal hydration on Goldmann applanation tonometry and corneal topography
    • Simon G, Small RH, Ren Q, Parel JM. Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. Refract Corneal Surg. 1993;9:110-117.
    • (1993) Refract Corneal Surg , vol.9 , pp. 110-117
    • Simon, G.1    Small, R.H.2    Ren, Q.3    Parel, J.M.4
  • 46
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 47
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156-162.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 49
    • 1842504236 scopus 로고    scopus 로고
    • Corneal thickness in glaucoma screening, diagnosis, and management
    • Brandt JD. Corneal thickness in glaucoma screening, diagnosis, and management. Curr Opin Ophthalmol. 2004;15:85-89.
    • (2004) Curr Opin Ophthalmol , vol.15 , pp. 85-89
    • Brandt, J.D.1
  • 51
    • 0037405409 scopus 로고    scopus 로고
    • Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus
    • Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135:620-627.
    • (2003) Am J Ophthalmol , vol.135 , pp. 620-627
    • Wollensak, G.1    Spoerl, E.2    Seiler, T.3
  • 52
    • 0043246587 scopus 로고    scopus 로고
    • Measuring the elastic modulus of ex vivo small tissue samples
    • Samani A, Bishop J, Luginbuhl C, Plewes DB. Measuring the elastic modulus of ex vivo small tissue samples. Phys Med Biol. 2003;48:2183-2198.
    • (2003) Phys Med Biol , vol.48 , pp. 2183-2198
    • Samani, A.1    Bishop, J.2    Luginbuhl, C.3    Plewes, D.B.4
  • 53
    • 0014271269 scopus 로고
    • Rheology of the cornea: Experimental techniques and results
    • Nyquist GW. Rheology of the cornea: experimental techniques and results. Exp Eye Res. 1968;7:183-188.
    • (1968) Exp Eye Res , vol.7 , pp. 183-188
    • Nyquist, G.W.1
  • 54
    • 0026748686 scopus 로고
    • Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas
    • Hoeltzel DA, Altman P, Buzard K, Choe K. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas. J Biomech Eng. 1992;114:202-215.
    • (1992) J Biomech Eng , vol.114 , pp. 202-215
    • Hoeltzel, D.A.1    Altman, P.2    Buzard, K.3    Choe, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.