메뉴 건너뛰기




Volumn 16, Issue 1, 2007, Pages 153-158

The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements

Author keywords

Applanation tonometry; Corneal thickness; Edema; Hydration; Intraocular pressure

Indexed keywords

ADULT; ARTICLE; CONTACT LENS; CORNEA CURVATURE; CORNEA EDEMA; CORNEA THICKNESS; CORRELATION COEFFICIENT; FEMALE; HUMAN; INTRAOCULAR PRESSURE; MALE; NORMAL HUMAN; OCULOPLETHYSMOGRAPHY; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; STUDENT T TEST; WATER CONTENT;

EID: 33846304686     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ijg.0000212277.95971.be     Document Type: Article
Times cited : (32)

References (57)
  • 1
    • 0029980777 scopus 로고    scopus 로고
    • Number of people with glaucoma worldwide
    • Quigley HA. Number of people with glaucoma worldwide. Br J Ophthalmol. 1996;80:389-393.
    • (1996) Br J Ophthalmol , vol.80 , pp. 389-393
    • Quigley, H.A.1
  • 2
    • 28444498636 scopus 로고    scopus 로고
    • American Academy of Ophthalmology, San Francisco, California: American Academy of Ophthalmology;
    • American Academy of Ophthalmology. Primary Open-angle Glaucoma. Preferred Practice Pattern. San Francisco, California: American Academy of Ophthalmology; 2005.
    • (2005) Primary Open-angle Glaucoma. Preferred Practice Pattern
  • 3
    • 33846276425 scopus 로고    scopus 로고
    • American Academy of Ophthalmology, San Francisco, California: American Academy of Ophthalmology;
    • American Academy of Ophthalmology. Primary Open-angle Glaucoma Suspect. Preferred Practice Pattern. San Francisco, California: American Academy of Ophthalmology; 2005.
    • (2005) Primary Open-angle Glaucoma Suspect. Preferred Practice Pattern
  • 4
    • 33846322096 scopus 로고    scopus 로고
    • ISO8612:2001(E): Ophthalmic Instruments-tonometers
    • International Standards Organization
    • International Standards Organization. ISO8612:2001(E): Ophthalmic Instruments-tonometers. Switzerland: ISO copyright office; 2001.
    • (2001) Switzerland: ISO copyright office
  • 5
    • 33846313084 scopus 로고    scopus 로고
    • Ritch R, Caronia RM, eds. Classic Papers in Glaucoma. The Hague, Netherlands:Kugler Publications;
    • Goldmann H, Schmidt T. Applanation tonometry [English translation]. In: Ritch R, Caronia RM, eds. Classic Papers in Glaucoma. The Hague, Netherlands:Kugler Publications;2000:155-162.
    • (2000) Applanation tonometry [English translation] , pp. 155-162
    • Goldmann, H.1    Schmidt, T.2
  • 6
    • 70449195078 scopus 로고
    • Reprint from: Über applanationstonometrie
    • Reprint from: Über applanationstonometrie. Ophthalmologica. 1957;134:221-242.
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
  • 8
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592-596.
    • (1993) Am J Ophthalmol , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3
  • 9
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61:551-572.
    • (1999) Bull Math Biol , vol.61 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 10
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement
    • Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement. J Cataract Refract Surg. 2005;31:146-155.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 11
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 12
    • 0032936567 scopus 로고    scopus 로고
    • Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
    • Copt R-P, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol. 1999;117:14-16.
    • (1999) Arch Ophthalmol , vol.117 , pp. 14-16
    • Copt, R.-P.1    Thomas, R.2    Mermoud, A.3
  • 13
    • 0034203035 scopus 로고    scopus 로고
    • The role of central corneal thickness in the diagnosis of glaucoma
    • Thomas R, Korah S, Muliyil J. The role of central corneal thickness in the diagnosis of glaucoma. Indian J Ophthalmol. 2000;48:107-111.
    • (2000) Indian J Ophthalmol , vol.48 , pp. 107-111
    • Thomas, R.1    Korah, S.2    Muliyil, J.3
  • 14
    • 0030885993 scopus 로고    scopus 로고
    • Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes
    • Herndon LW, Choudri SA, Cox T, et al. Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol. 1997;115:1137-1141.
    • (1997) Arch Ophthalmol , vol.115 , pp. 1137-1141
    • Herndon, L.W.1    Choudri, S.A.2    Cox, T.3
  • 15
    • 4444279897 scopus 로고    scopus 로고
    • Clinical significance of central corneal thickness in the management of glaucoma
    • Shih CY, Zivin JSG, Trokel SL, et al. Clinical significance of central corneal thickness in the management of glaucoma. Arch Ophthalmol. 2004;122:1270-1275.
    • (2004) Arch Ophthalmol , vol.122 , pp. 1270-1275
    • Shih, C.Y.1    Zivin, J.S.G.2    Trokel, S.L.3
  • 16
    • 0001534165 scopus 로고
    • The Goldmann applanation tonometer
    • Moses RA. The Goldmann applanation tonometer. Am J Ophthalmol. 1958;46:865-869.
    • (1958) Am J Ophthalmol , vol.46 , pp. 865-869
    • Moses, R.A.1
  • 17
    • 0027411731 scopus 로고
    • Effect of corneal hydration on Goldmann applanation tonometry and corneal topography
    • Simon G, Small RH, Ren Q, et al. Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. Refract Corneal Surg. 1993;9:110-117.
    • (1993) Refract Corneal Surg , vol.9 , pp. 110-117
    • Simon, G.1    Small, R.H.2    Ren, Q.3
  • 18
    • 0016788858 scopus 로고
    • Comparison of MacKay Marg, Goldmann and Perkins tonometers in abnormal corneas
    • McMillan F, Forster RK. Comparison of MacKay Marg, Goldmann and Perkins tonometers in abnormal corneas. Arch Ophthalmol. 1975;93:420-424.
    • (1975) Arch Ophthalmol , vol.93 , pp. 420-424
    • McMillan, F.1    Forster, R.K.2
  • 19
    • 0013929631 scopus 로고
    • The thickness-hydration relationship of the cornea
    • Hedbys BO, Mishima S. The thickness-hydration relationship of the cornea. Exp Eye Res. 1966;5:221-228.
    • (1966) Exp Eye Res , vol.5 , pp. 221-228
    • Hedbys, B.O.1    Mishima, S.2
  • 20
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whitacre MM, Stein RA. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.A.2
  • 21
    • 0031736985 scopus 로고    scopus 로고
    • Nocturnal elevation of intraocular pressure in young adults
    • Liu JHK, Kripke DF, Hoffman RE, et al. Nocturnal elevation of intraocular pressure in young adults. Invest Ophthalmol Vis Sci. 1998;39:2707-2712.
    • (1998) Invest Ophthalmol Vis Sci , vol.39 , pp. 2707-2712
    • Liu, J.H.K.1    Kripke, D.F.2    Hoffman, R.E.3
  • 22
    • 0032870796 scopus 로고    scopus 로고
    • Elevation of human intraocular pressure at night under moderate illumination
    • Liu JHK, Kripke DF, Hoffman RE, et al. Elevation of human intraocular pressure at night under moderate illumination. Invest Ophthalmol Vis Sci. 1999;40:2439-2442.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 2439-2442
    • Liu, J.H.K.1    Kripke, D.F.2    Hoffman, R.E.3
  • 24
    • 0016735286 scopus 로고
    • Diurnal variation of intraocular pressure in primary open-angle glaucoma
    • Kitazawa Y, Horie T. Diurnal variation of intraocular pressure in primary open-angle glaucoma. Am J Ophthalmol. 1975;79:557-566.
    • (1975) Am J Ophthalmol , vol.79 , pp. 557-566
    • Kitazawa, Y.1    Horie, T.2
  • 25
    • 0023142277 scopus 로고
    • Diurnal variation of intraocular pressure and the overriding effects of sleep
    • Frampton P, Da Rim D, Brown B. Diurnal variation of intraocular pressure and the overriding effects of sleep. Am J Optom Physiol Opt. 1987;64:54-61.
    • (1987) Am J Optom Physiol Opt , vol.64 , pp. 54-61
    • Frampton, P.1    Da Rim, D.2    Brown, B.3
  • 26
    • 0021123317 scopus 로고
    • Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
    • Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci. 1984;25:1161-1167.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 1161-1167
    • Holden, B.A.1    Mertz, G.W.2
  • 27
    • 0038300241 scopus 로고    scopus 로고
    • Influence of dorzolamide on corneal endothelium
    • Inoue K, Okugawa K, Oshika T, et al. Influence of dorzolamide on corneal endothelium. Jpn J Ophthalmol. 2003;47:129-133.
    • (2003) Jpn J Ophthalmol , vol.47 , pp. 129-133
    • Inoue, K.1    Okugawa, K.2    Oshika, T.3
  • 28
    • 0029166361 scopus 로고
    • Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetes
    • Skaff A, Cullen AP, Doughty MJ, et al. Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetes. Ophthalmic Physiol Opt. 1995;15:287-297.
    • (1995) Ophthalmic Physiol Opt , vol.15 , pp. 287-297
    • Skaff, A.1    Cullen, A.P.2    Doughty, M.J.3
  • 29
    • 0030026336 scopus 로고    scopus 로고
    • Standardizing the measurement of intraocular pressure for clinical research. Guidelines from the Eye Care Technology Forum
    • Kass MA. Standardizing the measurement of intraocular pressure for clinical research. Guidelines from the Eye Care Technology Forum. Ophthalmology. 1996;103:183-185.
    • (1996) Ophthalmology , vol.103 , pp. 183-185
    • Kass, M.A.1
  • 30
    • 33846267905 scopus 로고    scopus 로고
    • Dupont W, Plummer W. PS power and sample size program, 2.1.30 ed. Controlled Clin Trials. Available for free on the Internet. 1997:274.
    • Dupont W, Plummer W. PS power and sample size program, 2.1.30 ed. Controlled Clin Trials. Available for free on the Internet. 1997:274.
  • 31
    • 0028273231 scopus 로고
    • Reliability of intraocular pressure measurement with the Goldmann applanation tonometry in epidemiological studies
    • Dielemans I, Vingerling JR, Hofman A, et al. Reliability of intraocular pressure measurement with the Goldmann applanation tonometry in epidemiological studies. Graefe's Arch Clin Exp Ophthalmol. 1994;232:141-144.
    • (1994) Graefe's Arch Clin Exp Ophthalmol , vol.232 , pp. 141-144
    • Dielemans, I.1    Vingerling, J.R.2    Hofman, A.3
  • 32
    • 0021964014 scopus 로고
    • Central and peripheral corneal swelling accompanying soft lens extended wear
    • Bonanno JA, Polse KA. Central and peripheral corneal swelling accompanying soft lens extended wear. Am J Optom Physiol Opt. 1985;62:74-81.
    • (1985) Am J Optom Physiol Opt , vol.62 , pp. 74-81
    • Bonanno, J.A.1    Polse, K.A.2
  • 33
    • 0024510389 scopus 로고
    • Effect of eye patching on the overnight corneal swelling response with rigid contact lenses
    • Cox I, Ames K. Effect of eye patching on the overnight corneal swelling response with rigid contact lenses. Optom Vis Sci. 1989;66:207-208.
    • (1989) Optom Vis Sci , vol.66 , pp. 207-208
    • Cox, I.1    Ames, K.2
  • 34
    • 38249021067 scopus 로고
    • The overnight corneal swelling response of non-wear, daily wear, and extended wear soft lens patients
    • Cox I, Zantos SG, Orsborn GN. The overnight corneal swelling response of non-wear, daily wear, and extended wear soft lens patients. ICLC. 1990;17:134-137.
    • (1990) ICLC , vol.17 , pp. 134-137
    • Cox, I.1    Zantos, S.G.2    Orsborn, G.N.3
  • 35
    • 0022504895 scopus 로고
    • Intersubject variability in corneal swelling response to anoxia
    • Efron N. Intersubject variability in corneal swelling response to anoxia. Acta Ophthalmol. 1986;64:302-305.
    • (1986) Acta Ophthalmol , vol.64 , pp. 302-305
    • Efron, N.1
  • 36
    • 0019286216 scopus 로고
    • Corneal swelling at low atmospheric oxygen pressures
    • Mandell RB, Farrell R. Corneal swelling at low atmospheric oxygen pressures. Invest Ophthalmol Vis Sci. 1980;19:697-702.
    • (1980) Invest Ophthalmol Vis Sci , vol.19 , pp. 697-702
    • Mandell, R.B.1    Farrell, R.2
  • 37
  • 39
    • 0019731768 scopus 로고
    • Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit
    • Klyce SD. Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit. J Physiol. 1981;321:49-64.
    • (1981) J Physiol , vol.321 , pp. 49-64
    • Klyce, S.D.1
  • 41
    • 0027370666 scopus 로고
    • Investigation of parameters influencing intraocular pressure increases during sleep
    • Wildsoet C, Eyeson-Annan M, Brown B, et al. Investigation of parameters influencing intraocular pressure increases during sleep. Ophthalmic Physiol Opt. 1993;13:357-265.
    • (1993) Ophthalmic Physiol Opt , vol.13 , pp. 357-265
    • Wildsoet, C.1    Eyeson-Annan, M.2    Brown, B.3
  • 42
    • 33644842649 scopus 로고    scopus 로고
    • Corneal hydration control in contact lens wearers with diabetes mellitus
    • O'Donnell C, Efron N. Corneal hydration control in contact lens wearers with diabetes mellitus. Optom Vis Sci. 2006;83:22-26.
    • (2006) Optom Vis Sci , vol.83 , pp. 22-26
    • O'Donnell, C.1    Efron, N.2
  • 43
    • 0021256906 scopus 로고
    • Corneal response to rigid and hydrogel lenses during eye closure
    • O'Neal MR, Polse KA, Sarver MD. Corneal response to rigid and hydrogel lenses during eye closure. Invest Ophthalmol Vis Sci. 1984;25:837-842.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 837-842
    • O'Neal, M.R.1    Polse, K.A.2    Sarver, M.D.3
  • 44
    • 0019430860 scopus 로고
    • Corneal edema with hydrogel lenses and eye closure: Time course
    • Harris MG, Sarver MD, Brown LR. Corneal edema with hydrogel lenses and eye closure: Time course. Am J Optom Physiol Opt. 1981;58:18-20.
    • (1981) Am J Optom Physiol Opt , vol.58 , pp. 18-20
    • Harris, M.G.1    Sarver, M.D.2    Brown, L.R.3
  • 45
    • 0036288266 scopus 로고    scopus 로고
    • Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma
    • Realini T, Barber L, Burton D. Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma. Ophthalmology. 2002;109:1367-1371.
    • (2002) Ophthalmology , vol.109 , pp. 1367-1371
    • Realini, T.1    Barber, L.2    Burton, D.3
  • 46
    • 0027251292 scopus 로고
    • Individual variability in the diurnal intraocular pressure curve
    • Wilensky JT, Gieser DK, Dietsch ML, et al. Individual variability in the diurnal intraocular pressure curve. Ophthalmology. 1993;100:940-944.
    • (1993) Ophthalmology , vol.100 , pp. 940-944
    • Wilensky, J.T.1    Gieser, D.K.2    Dietsch, M.L.3
  • 48
    • 0026557018 scopus 로고
    • Hypotony and corneal edema secondary to patching in normal eyes
    • Levy B, Nguyen N, Abbott RL. Hypotony and corneal edema secondary to patching in normal eyes. Optom Vis Sci. 1992;69:72-75.
    • (1992) Optom Vis Sci , vol.69 , pp. 72-75
    • Levy, B.1    Nguyen, N.2    Abbott, R.L.3
  • 49
    • 0025911088 scopus 로고
    • Effect of contact lens removal or displacement on intraocular pressure
    • Khan JA, Graham CE. Effect of contact lens removal or displacement on intraocular pressure. Arch Ophthalmol. 1991;109:825-828.
    • (1991) Arch Ophthalmol , vol.109 , pp. 825-828
    • Khan, J.A.1    Graham, C.E.2
  • 50
    • 0015291453 scopus 로고
    • Pressure measurement: Which tonometer?
    • Kaufman HE. Pressure measurement: which tonometer? Invest Ophthalmol Vis Sci. 1972;11:80-85.
    • (1972) Invest Ophthalmol Vis Sci , vol.11 , pp. 80-85
    • Kaufman, H.E.1
  • 51
    • 0242288026 scopus 로고    scopus 로고
    • Repeatability and reproducibility of the BVI ultrasonic pachymeter
    • Gunvant P, Broadway DC, Watkins RJ. Repeatability and reproducibility of the BVI ultrasonic pachymeter. Eye. 2003;17:825-828.
    • (2003) Eye , vol.17 , pp. 825-828
    • Gunvant, P.1    Broadway, D.C.2    Watkins, R.J.3
  • 52
    • 0027054040 scopus 로고
    • Short-term effects of proparacaine on human corneal thickness
    • Herse P, Siu A. Short-term effects of proparacaine on human corneal thickness. Acta Ophthalmol Scand. 1992;70:740-744.
    • (1992) Acta Ophthalmol Scand , vol.70 , pp. 740-744
    • Herse, P.1    Siu, A.2
  • 53
    • 0030477331 scopus 로고    scopus 로고
    • Harper CL, Boulton ME, Bennett D, et al. Diurnal variations in human corneal thickness [published erratum appears in Br J Ophthal. 1997;81:175]. Br J Ophthalmol. 1996;80:1068-1072.
    • Harper CL, Boulton ME, Bennett D, et al. Diurnal variations in human corneal thickness [published erratum appears in Br J Ophthal. 1997;81:175]. Br J Ophthalmol. 1996;80:1068-1072.
  • 54
    • 0019195065 scopus 로고
    • Overnight swelling of the living human cornea
    • Mertz GW. Overnight swelling of the living human cornea. J Am Opt Assoc. 1980;51:211-214.
    • (1980) J Am Opt Assoc , vol.51 , pp. 211-214
    • Mertz, G.W.1
  • 55
    • 0013850022 scopus 로고
    • Thinning of the human cornea on awakening
    • Mandell R, Fatt I. Thinning of the human cornea on awakening. Nature. 1965;208:292-293.
    • (1965) Nature , vol.208 , pp. 292-293
    • Mandell, R.1    Fatt, I.2
  • 56
    • 0034978006 scopus 로고    scopus 로고
    • Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography
    • Feng Y, Varikooty J, Simpson TL. Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea. 2001;20:480-483.
    • (2001) Cornea , vol.20 , pp. 480-483
    • Feng, Y.1    Varikooty, J.2    Simpson, T.L.3
  • 57
    • 0037378859 scopus 로고    scopus 로고
    • Diurnal variation of corneal sensitivity and thickness
    • du Toit R, Fonn D, Simpson T, et al. Diurnal variation of corneal sensitivity and thickness. Cornea. 2003;23:205-209.
    • (2003) Cornea , vol.23 , pp. 205-209
    • du Toit, R.1    Fonn, D.2    Simpson, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.