메뉴 건너뛰기




Volumn 469, Issue 8, 2011, Pages 2337-2345

Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator

Author keywords

[No Author keywords available]

Indexed keywords

CARBON; CHROMIUM; COBALT; DIAMOND; MAGNESIUM OXIDE; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 79960946519     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-011-1800-7     Document Type: Article
Times cited : (11)

References (49)
  • 2
    • 0029278209 scopus 로고
    • Wettability and interfacial interactions in bioceramic-body-liquid systems
    • 10.1002/jbm.820290402
    • S Agathopoulous N Nikolopoulos 1995 Wettability and interfacial interactions in bioceramic-body-liquid systems J Biomed Mater Res. 29 421 429 10.1002/jbm.820290402
    • (1995) J Biomed Mater Res. , vol.29 , pp. 421-429
    • Agathopoulous, S.1    Nikolopoulos, N.2
  • 3
    • 34547597269 scopus 로고    scopus 로고
    • American Society of Mechanical Engineers New York, NY: American Society of Mechanical Engineers
    • American Society of Mechanical Engineers. ASME B46.1-2002: Surface T Texture (surface roughness, waviness, and lay). New York, NY: American Society of Mechanical Engineers; 2002.
    • (2002) ASME B46.1-2002: Surface T Texture (Surface Roughness, Waviness, and Lay)
  • 11
    • 0033775261 scopus 로고    scopus 로고
    • Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    • 11039790 10.1097/00003086-200010000-00006
    • IC Clarke A Gustafson 2000 Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear Clin Orthop Relat Res. 379 34 40 11039790 10.1097/00003086-200010000-00006
    • (2000) Clin Orthop Relat Res. , vol.379 , pp. 34-40
    • Clarke, I.C.1    Gustafson, A.2
  • 12
    • 0029033367 scopus 로고
    • Femoral head technologies to reduce polyethylene wear in total hip arthroplasty
    • 7671496
    • JM Cuckler J Bearcroft CM Asgian 1995 Femoral head technologies to reduce polyethylene wear in total hip arthroplasty Clin Orthop Relat Res. 317 57 63 7671496
    • (1995) Clin Orthop Relat Res. , vol.317 , pp. 57-63
    • Cuckler, J.M.1    Bearcroft, J.2    Asgian, C.M.3
  • 13
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • JA Davidson 1993 Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear Clin Orthop Relat Res. 294 361 378 8358943 (Pubitemid 23277129)
    • (1993) Clinical Orthopaedics and Related Research , Issue.294 , pp. 361-378
    • Davidson, J.A.1
  • 14
    • 0032605637 scopus 로고    scopus 로고
    • A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements
    • 10333684 10.1243/0954411991534843 1:STN:280:DyaK1M3ms1ahtA%3D%3D
    • PA Dearnley 1999 A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements Proc Inst Mech Eng H. 213 107 135 10333684 10.1243/0954411991534843 1:STN:280:DyaK1M3ms1ahtA%3D%3D
    • (1999) Proc Inst Mech Eng H. , vol.213 , pp. 107-135
    • Dearnley, P.A.1
  • 15
    • 12744277943 scopus 로고    scopus 로고
    • A critical comparison of methods for the determination of aging sensitivity in biomedical grade yttria-stabilized zirconia
    • 15654702
    • S Deville L Gremillard J Chevalier G Fantozzi 2005 A critical comparison of methods for the determination of aging sensitivity in biomedical grade yttria-stabilized zirconia J Biomed Mater Res B Appl Biomater. 72 239 245 15654702
    • (2005) J Biomed Mater Res B Appl Biomater. , vol.72 , pp. 239-245
    • Deville, S.1    Gremillard, L.2    Chevalier, J.3    Fantozzi, G.4
  • 16
    • 71549126508 scopus 로고    scopus 로고
    • Evaluation of phase stability in zirconia femoral heads from different manufacturers after in vitro testing or in vivo retrieval
    • 19679435 10.1016/j.arth.2009.06.026
    • K Fukatsu G Pezzotti Y Hayaishi N Sugano 2009 Evaluation of phase stability in zirconia femoral heads from different manufacturers after in vitro testing or in vivo retrieval J Arthroplasty. 24 1225 1230 19679435 10.1016/j.arth.2009.06.026
    • (2009) J Arthroplasty. , vol.24 , pp. 1225-1230
    • Fukatsu, K.1    Pezzotti, G.2    Hayaishi, Y.3    Sugano, N.4
  • 17
    • 78650002269 scopus 로고    scopus 로고
    • Wear comparison between a highly cross-linked polyethylene and conventional polyethylene against a zirconia femoral head minimum: 5-year follow-up
    • 20097032 10.1016/j.arth.2009.11.005
    • K Fukui A Kaneuji T Sugimori T Ichiseki K Kitamura T Matsumoto 2011 Wear comparison between a highly cross-linked polyethylene and conventional polyethylene against a zirconia femoral head minimum: 5-year follow-up J Arthroplasty. 26 45 49 20097032 10.1016/j.arth.2009.11.005
    • (2011) J Arthroplasty. , vol.26 , pp. 45-49
    • Fukui, K.1    Kaneuji, A.2    Sugimori, T.3    Ichiseki, T.4    Kitamura, K.5    Matsumoto, T.6
  • 18
    • 58149291643 scopus 로고    scopus 로고
    • Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads
    • 19024155 10.1243/09544119JEIM407 1:CAS:528:DC%2BD1cXhsFWit7nP
    • A Galvin C Brockett S Williams P Hatto A Burton G Isaac E Ingham J Fisher 2008 Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads Proc Inst Mech Eng H. 222 1073 1080 19024155 10.1243/09544119JEIM407 1:CAS:528:DC%2BD1cXhsFWit7nP
    • (2008) Proc Inst Mech Eng H. , vol.222 , pp. 1073-1080
    • Galvin, A.1    Brockett, C.2    Williams, S.3    Hatto, P.4    Burton, A.5    Isaac, G.6    Ingham, E.7    Fisher, J.8
  • 19
    • 0345060377 scopus 로고    scopus 로고
    • Comparison of the Wear Rates of Twenty-eight and Thirty-two-Millimeter Femoral Heads on Cross-Linked Polyethylene Acetabular Cups in a Wear Simulator
    • JC Hermida A Bergula P Chen CW Colwell Jr DD D'Lima 2003 Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator J Bone Joint Surg Am. 85 2325 2331 14668501 (Pubitemid 37499641)
    • (2003) Journal of Bone and Joint Surgery - Series A , vol.85 , Issue.12 , pp. 2325-2331
    • Hermida, J.C.1    Bergula, A.2    Chen, P.3    Colwell Jr., C.W.4    D'Lima, D.D.5
  • 20
    • 71549117051 scopus 로고    scopus 로고
    • Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: Prospective randomized trial
    • 19679444 10.1016/j.arth.2009.05.020
    • K Ise K Kawanabe J Tamura H Akiyama K Goto T Nakamura 2009 Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial J Arthroplasty. 24 1216 1220 19679444 10.1016/j.arth.2009.05.020
    • (2009) J Arthroplasty. , vol.24 , pp. 1216-1220
    • Ise, K.1    Kawanabe, K.2    Tamura, J.3    Akiyama, H.4    Goto, K.5    Nakamura, T.6
  • 21
    • 71549172202 scopus 로고    scopus 로고
    • Differences in highly cross-linked polyethylene wear between zirconia and cobalt-chromium femoral heads in Japanese patients: A prospective, randomized study
    • 19896062 10.1016/j.arth.2009.05.023
    • K Kawate T Ohmura I Kawahara K Tamai T Ueha K Takemura 2009 Differences in highly cross-linked polyethylene wear between zirconia and cobalt-chromium femoral heads in Japanese patients: a prospective, randomized study J Arthroplasty. 24 1221 1224 19896062 10.1016/j.arth.2009.05.023
    • (2009) J Arthroplasty. , vol.24 , pp. 1221-1224
    • Kawate, K.1    Ohmura, T.2    Kawahara, I.3    Tamai, K.4    Ueha, T.5    Takemura, K.6
  • 22
    • 0024992964 scopus 로고
    • Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball
    • DOI 10.1007/BF00419946
    • I Kempf M Semlitsch 1990 Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball Arch Orthop Trauma Surg. 109 284 287 2271364 10.1007/BF00419946 1:STN:280:DyaK3M7gsVaktg%3D%3D (Pubitemid 20259295)
    • (1990) Archives of Orthopaedic and Trauma Surgery , vol.109 , Issue.5 , pp. 284-287
    • Kempf, I.1    Semlitsch, M.2
  • 23
    • 23044447438 scopus 로고    scopus 로고
    • Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: A prospective, randomized study
    • DOI 10.2106/JBJS.D.02572
    • YH Kim 2005 Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective, randomized study J Bone Joint Surg Am. 87 1769 1776 16085617 10.2106/JBJS.D.02572 (Pubitemid 41061196)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.8 , pp. 1769-1776
    • Kim, Y.-H.1
  • 24
    • 38949161946 scopus 로고    scopus 로고
    • Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty
    • DOI 10.2106/JBJS.F.01489
    • KH Koo YC Ha WH Jung SR Kim JJ Yoo HJ Kim 2008 Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty J Bone Joint Surg Am. 90 329 336 18245593 10.2106/JBJS.F.01489 (Pubitemid 351341045)
    • (2008) Journal of Bone and Joint Surgery - Series A , vol.90 , Issue.2 , pp. 329-336
    • Koo, K.-H.1    Ha, Y.-C.2    Woon, H.J.3    Kim, S.-R.4    Jeong, J.Y.5    Hee, J.K.6
  • 26
    • 0029237462 scopus 로고
    • Environmental degradation of zirconia ceramics
    • 10.1016/0955-2219(95)00035-S 1:CAS:528:DyaK2MXmt1akt7c%3D
    • S Lawson 1995 Environmental degradation of zirconia ceramics J Eur Ceram Soc. 15 485 502 10.1016/0955-2219(95)00035-S 1:CAS:528:DyaK2MXmt1akt7c%3D
    • (1995) J Eur Ceram Soc. , vol.15 , pp. 485-502
    • Lawson, S.1
  • 27
    • 0032773373 scopus 로고    scopus 로고
    • Effect of protein lubrication on the wear properties of materials for prosthetic joints
    • DOI 10.1002/(SICI)1097-4636(1999)48: 4<465::AID-JBM10>3.0.CO;2-Y
    • YS Liao PD Benya HA McKellop 1999 Effect of protein lubrication on the wear properties of materials for prosthetic joints J Biomed Mater Res. 48 465 473 10421688 10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y 1:STN:280:DyaK1MzltVCmtA%3D%3D (Pubitemid 29337221)
    • (1999) Journal of Biomedical Materials Research , vol.48 , Issue.4 , pp. 465-473
    • Liao, Y.-S.1    Benya, P.D.2    McKellop, H.A.3
  • 28
    • 34249008416 scopus 로고    scopus 로고
    • Phase stability of zirconia and alumina/zirconia composite heads against UHMWPE liners in a temperature-controlled hip simulation study
    • Y-S Liao M Hames JC Fryman M DiSilvestro 2005 Phase stability of zirconia and alumina/zirconia composite heads against UHMWPE liners in a temperature-controlled hip simulation study Key Eng Mater. 284-286 991 994 10.4028/www.scientific.net/KEM.284-286.991 (Pubitemid 46780526)
    • (2005) Key Engineering Materials , vol.284-286 , pp. 991-994
    • Liao, Y.-S.1    Hanes, M.2    Fryman, J.C.3    DiSilvestro, M.4
  • 29
    • 33645230043 scopus 로고    scopus 로고
    • Serious metallosis of a metal head due to fragmented ceramic screws in a cemented THA
    • 16501983 10.1007/s00402-006-0112-y
    • H Miki N Sugano M Yamamura N Nakamura T Nishii H Yoshikawa 2006 Serious metallosis of a metal head due to fragmented ceramic screws in a cemented THA Arch Orthop Trauma Surg. 126 192 196 16501983 10.1007/s00402-006-0112-y
    • (2006) Arch Orthop Trauma Surg. , vol.126 , pp. 192-196
    • Miki, H.1    Sugano, N.2    Yamamura, M.3    Nakamura, N.4    Nishii, T.5    Yoshikawa, H.6
  • 30
    • 0025482370 scopus 로고
    • A protocol for contact angle measurement
    • 10.1088/0022-3727/23/9/003 1:CAS:528:DyaK3cXlvFykur0%3D
    • MD Murray BW Darvell 1990 A protocol for contact angle measurement J Phys D: Appl Phys. 23 1150 1155 10.1088/0022-3727/23/9/003 1:CAS:528: DyaK3cXlvFykur0%3D
    • (1990) J Phys D: Appl Phys. , vol.23 , pp. 1150-1155
    • Murray, M.D.1    Darvell, B.W.2
  • 31
    • 78249273640 scopus 로고    scopus 로고
    • Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads
    • 19879725 10.1016/j.arth.2009.09.006
    • I Nakahara N Nakamura T Nishii H Miki T Sakai N Sugano 2010 Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads J Arthroplasty. 25 1182 1187 19879725 10.1016/j.arth.2009.09.006
    • (2010) J Arthroplasty. , vol.25 , pp. 1182-1187
    • Nakahara, I.1    Nakamura, N.2    Nishii, T.3    Miki, H.4    Sakai, T.5    Sugano, N.6
  • 32
    • 0016881356 scopus 로고
    • Force actions transmitted by joints in the human body
    • 3785 10.1098/rspb.1976.0004 1:STN:280:DyaE287lt1ersA%3D%3D
    • JP Paul 1976 Force actions transmitted by joints in the human body Proc R Soc Lond B Biol Sci. 192 163 172 3785 10.1098/rspb.1976.0004 1:STN:280:DyaE287lt1ersA%3D%3D
    • (1976) Proc R Soc Lond B Biol Sci. , vol.192 , pp. 163-172
    • Paul, J.P.1
  • 33
    • 0037165927 scopus 로고    scopus 로고
    • Diamond-like amorphous carbon
    • 10.1016/S0927-796X(02)00005-0
    • J Robertson 2002 Diamond-like amorphous carbon Mater Sci Eng R. 37 129 281 10.1016/S0927-796X(02)00005-0
    • (2002) Mater Sci Eng R. , vol.37 , pp. 129-281
    • Robertson, J.1
  • 34
    • 76249109480 scopus 로고    scopus 로고
    • Letter to the Editor: Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads
    • 19949908 10.1007/s11999-009-1176-0 author reply 626-627
    • ME Roy LA Whiteside 2010 Letter to the Editor: Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads Clin Orthop Relat Res. 468 624 625 19949908 10.1007/s11999-009-1176-0 author reply 626-627
    • (2010) Clin Orthop Relat Res. , vol.468 , pp. 624-625
    • Roy, M.E.1    Whiteside, L.A.2
  • 35
    • 65949088092 scopus 로고    scopus 로고
    • Diamond-like carbon coatings enhance scratch resistance of bearing surfaces for use in joint arthroplasty: Hard substrates outperform soft
    • 18985791 10.1002/jbm.b.31244 1:CAS:528:DC%2BD1MXlt1ygs74%3D
    • ME Roy LA Whiteside BJ Katerberg 2009 Diamond-like carbon coatings enhance scratch resistance of bearing surfaces for use in joint arthroplasty: hard substrates outperform soft J Biomed Mater Res B Appl Biomater. 89B 527 535 18985791 10.1002/jbm.b.31244 1:CAS:528:DC%2BD1MXlt1ygs74%3D
    • (2009) J Biomed Mater Res B Appl Biomater. , vol.89 , pp. 527-535
    • Roy, M.E.1    Whiteside, L.A.2    Katerberg, B.J.3
  • 36
    • 36849059235 scopus 로고    scopus 로고
    • Phase transformation, roughness, and microhardness of artificially aged yttria- and magnesia-stabilized zirconia femoral heads
    • DOI 10.1002/jbm.a.31438
    • ME Roy LA Whiteside BJ Katerberg JA Steiger 2007 Phase transformation, roughness, and microhardness of artificially aged yttria- and magnesia-stabilized zirconia femoral heads J Biomed Mater Res. 83A 1096 1102 10.1002/jbm.a.31438 1:CAS:528:DC%2BD2sXhsValt7bF (Pubitemid 350231771)
    • (2007) Journal of Biomedical Materials Research - Part A , vol.83 , Issue.4 , pp. 1096-1102
    • Roy, M.E.1    Whiteside, L.A.2    Katerberg, B.J.3    Steiger, J.A.4
  • 38
    • 76949091728 scopus 로고    scopus 로고
    • Diamond-like carbon coatings enhance the hardness and resilience of bearing surfaces for use in joint arthroplasty
    • 19861184 10.1016/j.actbio.2009.10.037 1:CAS:528:DC%2BC3cXkvVOqsbo%3D
    • ME Roy LA Whiteside J Xu BJ Katerberg 2010 Diamond-like carbon coatings enhance the hardness and resilience of bearing surfaces for use in joint arthroplasty Acta Biomater. 6 1619 1624 19861184 10.1016/j.actbio.2009.10.037 1:CAS:528:DC%2BC3cXkvVOqsbo%3D
    • (2010) Acta Biomater. , vol.6 , pp. 1619-1624
    • Roy, M.E.1    Whiteside, L.A.2    Xu, J.3    Katerberg, B.J.4
  • 39
    • 0029616092 scopus 로고
    • Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator
    • VO Saikko 1995 Wear of the polyethylene acetabular cup: the effect of head material, head diameter, and cup thickness studied with a hip simulator Acta Orthop Scand. 66 501 506 8553815 10.3109/17453679509002302 1:STN:280:DyaK287ksVChsA%3D%3D (Pubitemid 26015376)
    • (1995) Acta Orthopaedica Scandinavica , vol.66 , Issue.6 , pp. 501-506
    • Saikko, V.O.1
  • 40
    • 0035876256 scopus 로고    scopus 로고
    • Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon
    • DOI 10.1016/S0142-9612(00)00306-9, PII S0142961200003069
    • V Saikko T Ahlroos O Calonius J Keränen 2001 Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon Biomaterials. 22 1507 1514 11374449 10.1016/S0142-9612(00)00306-9 1:CAS:528:DC%2BD3MXktlGqurk%3D (Pubitemid 32551899)
    • (2001) Biomaterials , vol.22 , Issue.12 , pp. 1507-1514
    • Saikko, V.1    Ahlroos, T.2    Calonius, O.3    Keranen, J.4
  • 41
    • 33645354809 scopus 로고    scopus 로고
    • Wettability analysis of orthopaedic materials using optical contact angle methods
    • 10.4028/www.scientific.net/KEM.309-311.1199
    • A Salehi S Tsai V Pawar J Sprague G Hunter S Varma F Namavar 2006 Wettability analysis of orthopaedic materials using optical contact angle methods Key Eng Mater. 309-311 1199 1202 10.4028/www.scientific.net/KEM.309-311. 1199
    • (2006) Key Eng Mater. , vol.309-311 , pp. 1199-1202
    • Salehi, A.1    Tsai, S.2    Pawar, V.3    Sprague, J.4    Hunter, G.5    Varma, S.6    Namavar, F.7
  • 42
    • 0035465630 scopus 로고    scopus 로고
    • Tribological characterisation of diamond-like carbon coatings on Co-Cr-Mo alloy for orthopaedic applications
    • DOI 10.1016/S0257-8972(01)01425-6
    • D Sheeja BK Tay SP Lau LN Nung 2001 Tribological characterization of diamond-like carbon coatings on CoCr-Mo alloy for orthopaedic applications Surf Coat Tech. 146-147 410 416 10.1016/S0257-8972(01)01425-6 (Pubitemid 34021187)
    • (2001) Surface and Coatings Technology , vol.146-147 , pp. 410-416
    • Sheeja, D.1    Tay, B.K.2    Lau, S.P.3    Nung, L.N.4
  • 43
    • 0033720349 scopus 로고    scopus 로고
    • Simplified motion and loading compared to physiological motion and loading in a hip joint simulator
    • 10902437 1:STN:280:DC%2BD3cvgtVGhsw%3D%3D
    • SL Smith A Unsworth 2000 Simplified motion and loading compared to physiological motion and loading in a hip joint simulator Proc Inst Mech Eng H. 214 233 238 10902437 1:STN:280:DC%2BD3cvgtVGhsw%3D%3D
    • (2000) Proc Inst Mech Eng H. , vol.214 , pp. 233-238
    • Smith, S.L.1    Unsworth, A.2
  • 45
    • 70349899299 scopus 로고    scopus 로고
    • Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads
    • 19326182 10.1007/s11999-009-0799-5
    • M Stilling KA Nielsen K Søballe O Rahbek 2009 Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads Clin Orthop Relat Res. 467 2644 2650 19326182 10.1007/s11999-009-0799-5
    • (2009) Clin Orthop Relat Res. , vol.467 , pp. 2644-2650
    • Stilling, M.1    Nielsen, K.A.2    Søballe, K.3    Rahbek, O.4
  • 47
    • 1642488161 scopus 로고    scopus 로고
    • Comparison of Diamond-Like-Carbon and Alumina-Oxide articulating with Polyethylene in Total Hip Arthroplasty
    • DOI 10.1002/mawe.200300717
    • G Taeger LE Podleska B Schmidt M Ziegler D Nast-Kolb 2003 Comparison of diamond-like carbon and alumina-oxide articulating with polyethylene in total hip arthroplasty Materialwissenschaft und Werkstofftechnik. 34 1094 1100 10.1002/mawe.200300717 1:CAS:528:DC%2BD2cXhsVGjtrs%3D (Pubitemid 38127438)
    • (2003) Materialwissenschaft und Werkstofftechnik , vol.34 , Issue.12 , pp. 1094-1100
    • Taeger, G.1    Podleska, L.E.2    Schmidt, B.3    Ziegler, M.4    Nast-Kolb, D.5
  • 48
    • 0036795459 scopus 로고    scopus 로고
    • Delamination and spalling of diamond-like-carbon tribological surfaces
    • DOI 10.1016/S0925-9635(02)00163-2, PII S0925963502001632
    • R Wang C Mercer AG Evans CV Cooper HK Yoon 2002 Delamination and spalling of diamond-like-carbon tribological surfaces Diamond and Related Materials. 11 1797 1803 10.1016/S0925-9635(02)00163-2 1:CAS:528:DC%2BD38XmvVGqtbY%3D (Pubitemid 35169892)
    • (2002) Diamond and Related Materials , vol.11 , Issue.10 , pp. 1797-1803
    • Wang, R.1    Mercer, C.2    Evans, A.G.3    Cooper, C.V.4    Yoon, H.K.5
  • 49
    • 0042564752 scopus 로고    scopus 로고
    • Tribochemical reaction on metal-on-metal hip joint bearings A comparison between in-vitro and in-vivo results
    • DOI 10.1016/S0043-1648(03)00127-3
    • MA Wimmer C Sprecher R Hauert G Täger A Fischer 2003 Tribochemical reaction on metal-on-metal hip joint bearings: a comparison between in-vivo and in-vitro results Wear. 255 1007 1014 10.1016/S0043-1648(03)00127-3 1:CAS:528:DC%2BD3sXls1Ohsbw%3D (Pubitemid 36990826)
    • (2003) Wear , vol.255 , Issue.7-12 , pp. 1007-1014
    • Wimmer, M.A.1    Sprecher, C.2    Hauert, R.3    Tager, G.4    Fischer, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.