메뉴 건너뛰기




Volumn 220, Issue 3, 2006, Pages 457-464

The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints

Author keywords

In vitro experiments; Metal on polyethylene artificial hip joints; Surface profile parameters; Wear

Indexed keywords

METALS; POLYETHYLENES; REGRESSION ANALYSIS; SURFACE ROUGHNESS; WEAR OF MATERIALS; HIGHER ORDER STATISTICS; HIP PROSTHESES;

EID: 33746403401     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM95     Document Type: Article
Times cited : (53)

References (39)
  • 2
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert, H. G. Reactions of the articular capsule to wear products of artificial joint prostheses. J. Biomed. Mater. Res., 1977, 11(2), 157-164.
    • (1977) J. Biomed. Mater. Res. , vol.11 , Issue.2 , pp. 157-164
    • Willert, H.G.1
  • 4
    • 0023993548 scopus 로고
    • The effect of counterface surface roughness on the wear of UHMWPE in water and oil-in-water emulsion
    • Lloyd, A. I. and Noel, R. E. The effect of counterface surface roughness on the wear of UHMWPE in water and oil-in-water emulsion. Tribology Int., 1988, 21, 83-88.
    • (1988) Tribology Int. , vol.21 , pp. 83-88
    • Lloyd, A.I.1    Noel, R.E.2
  • 5
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total hip replacements
    • Wang, A., Sun, D. C., Stark, C., and Dumbleton, J. H. Wear mechanisms of UHMWPE in total hip replacements. Wear, 1995, 181-183, 241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 6
    • 0030634935 scopus 로고    scopus 로고
    • The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement
    • Lancaster, J. G., Dowson, D., Isaac, G. H., and Fisher, J. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proc. Instn Mech, Engrs, Part H, J. Engineering in Medicine, 1997, 211(H1), 17-24.
    • (1997) Proc. Instn Mech, Engrs, Part H, J. Engineering in Medicine , vol.211 , Issue.H1 , pp. 17-24
    • Lancaster, J.G.1    Dowson, D.2    Isaac, G.H.3    Fisher, J.4
  • 7
    • 0032804049 scopus 로고    scopus 로고
    • Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls
    • McKellop, H., Shen, F. W., DiMaio, W., and Lancaster, J. G. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin. Orthop., 1999, 369, 73-82.
    • (1999) Clin. Orthop. , vol.369 , pp. 73-82
    • McKellop, H.1    Shen, F.W.2    DiMaio, W.3    Lancaster, J.G.4
  • 8
    • 0033813897 scopus 로고    scopus 로고
    • Histological investigation of polyethylene particles in total hip replacement: Ceramic versus metal heads
    • Bos, I. Histological investigation of polyethylene particles in total hip replacement: ceramic versus metal heads. Hip Int., 2000, 10(3), 151-60.
    • (2000) Hip Int , vol.10 , Issue.3 , pp. 151-160
    • Bos, I.1
  • 10
    • 0035892402 scopus 로고    scopus 로고
    • Effect of counterface roughness on the Wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device
    • Saikko, V., Calonius, O., and Keränen, J. Effect of counterface roughness on the Wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. J. Biomed. Mater Res., 2001, 57(4), 506-512.
    • (2001) J. Biomed. Mater. Res. , vol.57 , Issue.4 , pp. 506-512
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 11
    • 0029693670 scopus 로고    scopus 로고
    • Utra-high molecular weight polyethylene wear derbris generated in vivo and in laboratory tests; the influence of counterface roughness
    • Haley, J. L., Ingham, E., Stone, M., Wrobleski, B. M., and Fisher, J. Utra-high molecular weight polyethylene wear derbris generated in vivo and in laboratory tests; the influence of counterface roughness. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210(H1), 3-10.
    • (1996) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.210 , Issue.H1 , pp. 3-10
    • Haley, J.L.1    Ingham, E.2    Stone, M.3    Wrobleski, B.M.4    Fisher, J.5
  • 12
    • 0032818125 scopus 로고    scopus 로고
    • The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement
    • Elfick, A. P. D., Hall, R. M., Pinder, I. M., and Unsworth, A. The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement. J. Biomed. Mater. Res., 1999, 48, 712-718.
    • (1999) J. Biomed. Mater. Res. , vol.48 , pp. 712-718
    • Elfick, A.P.D.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 13
    • 0036888509 scopus 로고    scopus 로고
    • The performance of gamma- and EtO-sterilised UHMWPE acetabulars cups tested under severe simulator conditions. Part 1: Role of the third-body wear process
    • Affatato, S., Bersaglia, G., Foltran, I., Taddei, P., Fini, G., and Toni, A. The performance of gamma- and EtO-sterilised UHMWPE acetabulars cups tested under severe simulator conditions. Part 1: role of the third-body wear process. Biomaterials, 2002, 23, 4839-4846.
    • (2002) Biomaterials , vol.23 , pp. 4839-4846
    • Affatato, S.1    Bersaglia, G.2    Foltran, I.3    Taddei, P.4    Fini, G.5    Toni, A.6
  • 14
    • 0028249007 scopus 로고
    • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris
    • Davidson, J. A., Poggie, R. A., and Mishra, A. K. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Bio-Med. Mater. Engng, 1994, 4(3), 213-229.
    • (1994) Bio-Med. Mater. Engng , vol.4 , Issue.3 , pp. 213-229
    • Davidson, J.A.1    Poggie, R.A.2    Mishra, A.K.3
  • 15
    • 0027407506 scopus 로고
    • In vivo wear of polyethylene acetabular components
    • Kabo, J. M., Gebhard, J. S., Loren, G., and Amstutz, H. C. In vivo wear of polyethylene acetabular components. T. Bone It Surg., 1993. 75B(2), 254-258.
    • (1993) J. Bone Jt Surg. , vol.75 B , Issue.2 , pp. 254-258
    • Kabo, J.M.1    Gebhard, J.S.2    Loren, G.3    Amstutz, H.C.4
  • 16
    • 0019620861 scopus 로고
    • Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multichannel screening device
    • McKellop, H., Clarke, I., Markolk, K., and Amstutz, H. Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multichannel screening device. J. Biomed. Mater. Res., 1981, 15, 619-623.
    • (1981) J. Biomed. Mater. Res. , vol.15 , pp. 619-623
    • McKellop, H.1    Clarke, I.2    Markolk, K.3    Amstutz, H.4
  • 17
    • 0028836831 scopus 로고
    • The origin of submicron polyethylene wear debris in total hip arthroplasty
    • Mckellop, H. A., Campbell, P., and Park, S. H. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin. Orthop. Rel. Res., 1995, 31l, 3-20.
    • (1995) Clin. Orthop. Rel. Res. , vol.311 , pp. 3-20
    • Mckellop, H.A.1    Campbell, P.2    Park, S.H.3
  • 18
    • 0032805747 scopus 로고    scopus 로고
    • The counterface, surface smoothness, tolerances, and coatings in total joint prostheses
    • Santavirta, S., Lappalainen, R., Pekko, P., Anttila, A., and Konttinen, Y. T. The counterface, surface smoothness, tolerances, and coatings in total joint prostheses. Clin. Orthop., 1999, 369, 92-102.
    • (1999) Clin. Orthop. , vol.369 , pp. 92-102
    • Santavirta, S.1    Lappalainen, R.2    Pekko, P.3    Anttila, A.4    Konttinen, Y.T.5
  • 19
    • 0033967283 scopus 로고    scopus 로고
    • Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints
    • Like, Q., Topoleski L. D. T., and Parks, N. L. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints. J. Appl. Biomater, 2000, 53, 111-118.
    • (2000) J. Appl. Biomater , vol.53 , pp. 111-118
    • Like, Q.1    Topoleski, L.D.T.2    Parks, N.L.3
  • 20
    • 0024095181 scopus 로고
    • Component wear of total knee prostheses using Ti-6Al-4V, titanium nitride coated Ti-6Al-4V, and cobalt-chromium-molybdenum femoral components
    • Peterson, C. D., Hillberry, B. M., and Heck, D. A. Component wear of total knee prostheses using Ti-6Al-4V, titanium nitride coated Ti-6Al-4V, and cobalt-chromium-molybdenum femoral components. J. Biomed. Mater Res., 1988, 22, 887-903.
    • (1988) J. Biomed. Mater Res. , vol.22 , pp. 887-903
    • Peterson, C.D.1    Hillberry, B.M.2    Heck, D.A.3
  • 21
    • 0020100045 scopus 로고
    • Exploratory investigations on the structure dependence of the wear resistance of polyethylene
    • Rose, R. M., Cimino, W. R., Ellis, E., and Crugnola, A. N. Exploratory investigations on the structure dependence of the wear resistance of polyethylene. Wear, 1982, 77, 89-104.
    • (1982) Wear , vol.77 , pp. 89-104
    • Rose, R.M.1    Cimino, W.R.2    Ellis, E.3    Crugnola, A.N.4
  • 23
    • 0242694390 scopus 로고    scopus 로고
    • A study on the third-body induced roughening of the prosthetic head in total hip replacement
    • Raimondi, M. T., Vena, P., and Pietrabissa, R. A study on the third-body induced roughening of the prosthetic head in total hip replacement. In Bioengineering Conference ASME, 2001.
    • (2001) Bioengineering Conference ASME
    • Raimondi, M.T.1    Vena, P.2    Pietrabissa, R.3
  • 24
    • 0343384352 scopus 로고    scopus 로고
    • The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating
    • Raimondi, M. T. and Pietrabissa, R. The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating. Biomaterials, 2000, 21(9), 907-913.
    • (2000) Biomaterials , vol.21 , Issue.9 , pp. 907-913
    • Raimondi, M.T.1    Pietrabissa, R.2
  • 25
    • 0034953264 scopus 로고    scopus 로고
    • Quantitative evaluation of the prosthetic head damage induced by microscopic third-body particles in total hip replacement
    • Raimondi, M. T., Vena, P., and Pietrabissa, R. Quantitative evaluation of the prosthetic head damage induced by microscopic third-body particles in total hip replacement. J. Biomed. Mater. Res. (Appl. Biomater), 2001, 58, 436-448.
    • (2001) J. Biomed. Mater. Res. (Appl. Biomater.) , vol.58 , pp. 436-448
    • Raimondi, M.T.1    Vena, P.2    Pietrabissa, R.3
  • 26
    • 0035876256 scopus 로고    scopus 로고
    • Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon
    • Saikko, V., Ahlroos, T., Calonius, O., and Keränen, J. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. Biomaterials, 2001, 22, 1507-1514.
    • (2001) Biomaterials , vol.22 , pp. 1507-1514
    • Saikko, V.1    Ahlroos, T.2    Calonius, O.3    Keränen, J.4
  • 28
    • 0033178857 scopus 로고    scopus 로고
    • Wear-testing of a temporomandibular joint prosthesis: UHMWPE and PTFE against a metal ball, in water and in serum
    • Van Loon, J.-P., Verkerke, G. J., de Bont, L. G. M., and Liem, R. S. B. Wear-testing of a temporomandibular joint prosthesis: UHMWPE and PTFE against a metal ball, in water and in serum. Biomaterials, 1999, 20, 1471-1478.
    • (1999) Biomaterials , vol.20 , pp. 1471-1478
    • Van Loon, J.-P.1    Verkerke, G.J.2    de Bont, L.G.M.3    Liem, R.S.B.4
  • 29
    • 0032841073 scopus 로고    scopus 로고
    • Surface roughness quantification of CoCrMo implant alloys
    • Que, L. and Topoleski, L. D. Surface roughness quantification of CoCrMo implant alloys. J. Biomed. Mater. Res., 1999, 48(5), 705-711.
    • (1999) J. Biomed. Mater. Res. , vol.48 , Issue.5 , pp. 705-711
    • Que, L.1    Topoleski, L.D.2
  • 30
    • 0035053741 scopus 로고    scopus 로고
    • Influence of polyethylene and femoral head surface quality on wear: A retrieval study
    • Haraguchi, K., Sugano, N., and Nishii, T. Influence of polyethylene and femoral head surface quality on wear: a retrieval study. Int. Orthop., 2001, 25(1), 29-34.
    • (2001) Int. Orthop. , vol.25 , Issue.1 , pp. 29-34
    • Haraguchi, K.1    Sugano, N.2    Nishii, T.3
  • 31
    • 0036435261 scopus 로고    scopus 로고
    • Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator
    • Saikko, V., Calonius, O., and Keränen, J. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. J. Biomed. Mater. Res. Part B: Appl. Biomater, 2002, 63B, 848-853.
    • (2002) J. Biomed. Mater. Res. Part B: Appl. Biomater. , vol.63 B , pp. 848-853
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 33
    • 0037813128 scopus 로고    scopus 로고
    • The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: Wear particle characteristics with isolation protocols
    • Affatato, S., Bersaglia, G., Emiliani, D., Foltran, I., Taddel, P., Reggiani, M., Ferrieri, P., and Toni, A. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols. Biomaterials, 2003, 24, 4045-4055.
    • (2003) Biomaterials , vol.24 , pp. 4045-4055
    • Affatato, S.1    Bersaglia, G.2    Emiliani, D.3    Foltran, I.4    Taddel, P.5    Reggiani, M.6    Ferrieri, P.7    Toni, A.8
  • 34
    • 0033868418 scopus 로고    scopus 로고
    • Femoral prosthetic heads and their signifcance in polyethylene wear
    • Falez, F., La Cava, F., and Panegrossi, G. Femoral prosthetic heads and their signifcance in polyethylene wear. Int. Orthop., 2000, 24, 126-129.
    • (2000) Int. Orthop. , vol.24 , pp. 126-129
    • Falez, F.1    La Cava, F.2    Panegrossi, G.3
  • 35
    • 0003151584 scopus 로고
    • Further experimental designs
    • In (Blackwell Scientific Publications, Oxford)
    • Armitage, P. and Berry, G. Further experimental designs. In Statistical Methods in Medical Research, 1994, pp. 237-282 (Blackwell Scientific Publications, Oxford).
    • (1994) Statistical Methods in Medical Research , pp. 237-282
    • Armitage, P.1    Berry, G.2
  • 36
    • 0004110959 scopus 로고
    • Regression and correlation
    • In (Blackwell Scientific Publications, Oxford)
    • Armitage, P. and Berry, G. Regression and correlation. In Statistical Methods in Medical Research, 1994, pp. 154-174 (Blackwell Scientific Publications, Oxford).
    • (1994) Statistical Methods in Medical Research , pp. 154-174
    • Armitage, P.1    Berry, G.2
  • 37
    • 11244301768 scopus 로고    scopus 로고
    • Implant for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastics materials
    • ISO
    • ISO. Implant for surgery - partial and total hip joint prostheses - Part 2: articulating surfaces made of metallic, ceramic and plastics materials, 1996.
    • (1996)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.