메뉴 건너뛰기




Volumn 85, Issue 12, 2003, Pages 2325-2331

Comparison of the Wear Rates of Twenty-eight and Thirty-two-Millimeter Femoral Heads on Cross-Linked Polyethylene Acetabular Cups in a Wear Simulator

Author keywords

[No Author keywords available]

Indexed keywords

LUBRICATING AGENT; POLYETHYLENE;

EID: 0345060377     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200312000-00009     Document Type: Article
Times cited : (66)

References (36)
  • 1
    • 0032804049 scopus 로고    scopus 로고
    • Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls
    • McKellop H, Shen FW, DiMaio W, Lancaster JG. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop. 1999;369:73-82.
    • (1999) Clin Orthop , vol.369 , pp. 73-82
    • McKellop, H.1    Shen, F.W.2    DiMaio, W.3    Lancaster, J.G.4
  • 2
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty. 2001;16:149-60.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 3
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br. 1996;78:280-5.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 4
    • 0035078816 scopus 로고    scopus 로고
    • Gamma-irradiated cross-linked polyethylene in total hip replacements-analysis of retrieved sockets after long-term implantation
    • Oonishi H, Kadoya Y, Masuda S. Gamma-irradiated cross-linked polyethylene in total hip replacements-analysis of retrieved sockets after long-term implantation. J Biomed Mater Res. 2001;58:167-71.
    • (2001) J Biomed Mater Res , vol.58 , pp. 167-171
    • Oonishi, H.1    Kadoya, Y.2    Masuda, S.3
  • 5
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz HC, Campbell P, Kossovsky N, Clarke IC. Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop. 1992;276:7-18.
    • (1992) Clin Orthop , vol.276 , pp. 7-18
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.C.4
  • 6
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • Harris WH. The problem is osteolysis. Clin Otthop. 1995;311:46-53.
    • (1995) Clin Otthop , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 7
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
    • Jasty M, Goetz DD, Bragdon CR, Lee KR, Hanson AE, Elder JR, Harris WH. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg Am. 1997;79:349-58.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 349-358
    • Jasty, M.1    Goetz, D.D.2    Bragdon, C.R.3    Lee, K.R.4    Hanson, A.E.5    Elder, J.R.6    Harris, W.H.7
  • 9
    • 0028880699 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application
    • Devane PA, Bourne RB, Rorabeck CH, MacDonald S, Robinson EJ. Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. Clin Orthop. 1995;319:317-26.
    • (1995) Clin Orthop , vol.319 , pp. 317-326
    • Devane, P.A.1    Bourne, R.B.2    Rorabeck, C.H.3    MacDonald, S.4    Robinson, E.J.5
  • 10
    • 0033384592 scopus 로고    scopus 로고
    • Early polyethylene wear and osteolysis in cementless total hip arthroplasty: The influence of femoral head size and polyethylene thickness
    • Lee PC, Shih CH, Chen WJ, Tu YK, Tai CL. Early polyethylene wear and osteolysis in cementless total hip arthroplasty: the influence of femoral head size and polyethylene thickness. J Arthroplasty. 1999;14:976-81.
    • (1999) J Arthroplasty , vol.14 , pp. 976-981
    • Lee, P.C.1    Shih, C.H.2    Chen, W.J.3    Tu, Y.K.4    Tai, C.L.5
  • 11
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518-28.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 12
    • 0031824099 scopus 로고    scopus 로고
    • Polyethylene wear with an entirely HA-coated total hip replacement: 79 Hips followed for 5 years
    • Rokkum M, Reigstad A. Polyethylene wear with an entirely HA-coated total hip replacement: 79 hips followed for 5 years. Acta Orthop Scand. 1998;69:253-8.
    • (1998) Acta Orthop Scand , vol.69 , pp. 253-258
    • Rokkum, M.1    Reigstad, A.2
  • 13
    • 0034012520 scopus 로고    scopus 로고
    • The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    • D'Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315-21.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 315-321
    • D'Lima, D.D.1    Urquhart, A.G.2    Buehler, K.O.3    Walker, R.H.4    Colwell Jr., C.W.5
  • 14
    • 0033819163 scopus 로고    scopus 로고
    • The effect of femoral component head size on posterior dislocation of the artificial hip joint
    • Bartz RL, Nobel PC, Kadakia NR, Tullos HS. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am. 2000;82:1300-7.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1300-1307
    • Bartz, R.L.1    Nobel, P.C.2    Kadakia, N.R.3    Tullos, H.S.4
  • 15
    • 0031016456 scopus 로고    scopus 로고
    • Joint motion and surface contact area related to component position in total hip arthroplasty
    • Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br. 1997;79:140-6.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 140-146
    • Robinson, R.P.1    Simonian, P.T.2    Gradisar, I.M.3    Ching, R.P.4
  • 16
    • 0031734480 scopus 로고    scopus 로고
    • A finite element analysis of factors influencing total hip dislocation
    • Scifert CF, Brown TD, Pedersen DR, Callaghan JJ. A finite element analysis of factors influencing total hip dislocation. Clin Orthop. 1998;355:152-62.
    • (1998) Clin Orthop , vol.355 , pp. 152-162
    • Scifert, C.F.1    Brown, T.D.2    Pedersen, D.R.3    Callaghan, J.J.4
  • 18
    • 0031788080 scopus 로고    scopus 로고
    • Relationship of femoral head and acetabular size to the prevalence of dislocation
    • Kelley SS, Lachiewicz PF, Hickman JM, Paterno SM. Relationship of femoral head and acetabular size to the prevalence of dislocation. Clin Orthop. 1998;355:163-70.
    • (1998) Clin Orthop , vol.355 , pp. 163-170
    • Kelley, S.S.1    Lachiewicz, P.F.2    Hickman, J.M.3    Paterno, S.M.4
  • 19
    • 0020356121 scopus 로고
    • Dislocations after total hip arthroplasty
    • Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295-306.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1295-1306
    • Woo, R.Y.1    Morrey, B.F.2
  • 20
    • 0032819104 scopus 로고    scopus 로고
    • Dislocation after total hip arthroplasty
    • Yuan L, Shih C. Dislocation after total hip arthroplasty. Arch Orthop Trauma Surg. 1999;119:263-6.
    • (1999) Arch Orthop Trauma Surg , vol.119 , pp. 263-266
    • Yuan, L.1    Shih, C.2
  • 23
    • 0041386214 scopus 로고    scopus 로고
    • Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator
    • D'Lima DD, Hermida JC, Chen PC, Colwell CW Jr. Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator. J Orthop Res. 2003;21:761-6.
    • (2003) J Orthop Res , vol.21 , pp. 761-766
    • D'Lima, D.D.1    Hermida, J.C.2    Chen, P.C.3    Colwell Jr., C.W.4
  • 24
    • 0030667687 scopus 로고    scopus 로고
    • Difficult complications after hip joint replacement. Dislocation
    • Morrey BF. Difficult complications after hip joint replacement. Dislocation. Clin Orthop. 1997;344:179-87.
    • (1997) Clin Orthop , vol.344 , pp. 179-187
    • Morrey, B.F.1
  • 25
    • 0035215251 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty with use of improved cementing techniques: A minimum twenty-year follow-up study
    • Klapach AS, Callaghan JJ, Goetz DD, Olejniczak JP, Johnston RC. Charnley total hip arthroplasty with use of improved cementing techniques: a minimum twenty-year follow-up study. J Bone Joint Surg Am. 2001;83:1840-8.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1840-1848
    • Klapach, A.S.1    Callaghan, J.J.2    Goetz, D.D.3    Olejniczak, J.P.4    Johnston, R.C.5
  • 26
    • 0032833192 scopus 로고    scopus 로고
    • Risk factors for dislocation during the first 3 months after primary total hip replacement
    • Woolson ST, Rahimtoola ZO. Risk factors for dislocation during the first 3 months after primary total hip replacement. J Arthroplasty. 1999;14:662-8.
    • (1999) J Arthroplasty , vol.14 , pp. 662-668
    • Woolson, S.T.1    Rahimtoola, Z.O.2
  • 27
    • 0033945009 scopus 로고    scopus 로고
    • Cementless acetabular replacement in the young. A 5- to 10-year prospective study
    • Dunkley AB, Eldridge JD, Lee MB, Smith EJ, Learmonth ID. Cementless acetabular replacement in the young. A 5- to 10-year prospective study. Clin Orthop. 2000;376:149-55.
    • (2000) Clin Orthop , vol.376 , pp. 149-155
    • Dunkley, A.B.1    Eldridge, J.D.2    Lee, M.B.3    Smith, E.J.4    Learmonth, I.D.5
  • 28
    • 0035069544 scopus 로고    scopus 로고
    • Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literature
    • Oparaugo PC, Clarke IC, Malchau H, Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature. Acta Orthop Scand. 2001;72:22-8.
    • (2001) Acta Orthop Scand , vol.72 , pp. 22-28
    • Oparaugo, P.C.1    Clarke, I.C.2    Malchau, H.3    Herberts, P.4
  • 31
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am. 1995;77:432-9.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 432-439
    • Zicat, B.1    Engh, C.A.2    Gokcen, E.3
  • 32
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
    • Muratoglu OK, Bragdon CR, O'Connor D, Perinchief RS, Estok DM 2nd, Jasty M, Harris WH. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty. 2001;16 (8 Suppl 1):24-30.
    • (2001) J Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Perinchief, R.S.4    Estok II, D.M.5    Jasty, M.6    Harris, W.H.7
  • 33
    • 0035864336 scopus 로고    scopus 로고
    • Properties of crosslinked ultra-high-molecular-weight polyethylene
    • Lewis G. Properties of crosslinked ultra-high-molecular-weight polyethylene. Biomaterials. 2001;22:371-401.
    • (2001) Biomaterials , vol.22 , pp. 371-401
    • Lewis, G.1
  • 34
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L. Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res. 1999;46:573-81.
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 35
    • 0036381521 scopus 로고    scopus 로고
    • Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE
    • Cole JC, Lemons JE, Eberhardt AW. Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE. J Biomed Mater Res. 2002;63:559-66.
    • (2002) J Biomed Mater Res , vol.63 , pp. 559-566
    • Cole, J.C.1    Lemons, J.E.2    Eberhardt, A.W.3
  • 36
    • 0036796360 scopus 로고    scopus 로고
    • In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    • Komistek RD, Dennis DA, Ochoa JA, Haas BD, Hammill C. In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty. J Bone Joint Surg Am. 2002;84:1836-41.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1836-1841
    • Komistek, R.D.1    Dennis, D.A.2    Ochoa, J.A.3    Haas, B.D.4    Hammill, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.