메뉴 건너뛰기




Volumn 56, Issue 2, 2011, Pages 132-140

Influence of implant abutment angulations on the fracture resistance of overlaying CAM-milled zirconia single crowns

Author keywords

abutment angulations; core thickness; implant; Zirconia

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; EUGENOL; TEMP BOND; TEMP-BOND; WATER; ZINC OXIDE; ZINC OXIDE EUGENOL; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 79957866789     PISSN: 00450421     EISSN: 18347819     Source Type: Journal    
DOI: 10.1111/j.1834-7819.2011.01314.x     Document Type: Article
Times cited : (14)

References (36)
  • 2
    • 0028437167 scopus 로고
    • Fracture resistance of teeth restored with dentin-bonded crowns
    • Burke FJT, Watts DC,. Fracture resistance of teeth restored with dentin-bonded crowns. Quintessence Int 1994; 25: 335-340.
    • (1994) Quintessence Int , vol.25 , pp. 335-340
    • Burke, F.J.T.1    Watts, D.C.2
  • 3
    • 34250679929 scopus 로고    scopus 로고
    • The bases for using a particular occlusal design in tooth and implant-borne reconstructions and complete dentures
    • Suppl 3:. Erratum in Clin Oral Implants Res 2008; 19: 326 - 328.
    • Klineberg I, Kingston D, Murray G,. The bases for using a particular occlusal design in tooth and implant-borne reconstructions and complete dentures. Clin Oral Implants Res 2007; 18 Suppl 3: 151-167. Erratum in Clin Oral Implants Res 2008; 19: 326-328.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 151-167
    • Klineberg, I.1    Kingston, D.2    Murray, G.3
  • 4
    • 0027758169 scopus 로고
    • Hierarchy of objectives in implant placement to maximize aesthetics: Use of pre-angulated abutments
    • Gelb DA, Lazzara RJ,. Hierarchy of objectives in implant placement to maximize aesthetics: use of pre-angulated abutments. Int J Periodontics Restorative Dent 1993; 13: 277-287.
    • (1993) Int J Periodontics Restorative Dent , vol.13 , pp. 277-287
    • Gelb, D.A.1    Lazzara, R.J.2
  • 5
    • 0024228710 scopus 로고
    • Biomechanics of oral implants: Future research directions
    • Brunski JB,. Biomechanics of oral implants: future research directions. J Dent Educ 1988; 52: 775-787.
    • (1988) J Dent Educ , vol.52 , pp. 775-787
    • Brunski, J.B.1
  • 6
    • 43049144663 scopus 로고    scopus 로고
    • The effect of finish line preparation and layer thickness on the failure load and fractography of ZRO2 Copings
    • Reich S, Petschelt A, Lohbauer U,. The effect of finish line preparation and layer thickness on the failure load and fractography of ZRO2 Copings. J Prosthet Dent 2008; 99: 369-376.
    • (2008) J Prosthet Dent , vol.99 , pp. 369-376
    • Reich, S.1    Petschelt, A.2    Lohbauer, U.3
  • 7
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
    • DOI 10.1016/j.prosdent.2004.09.015, PII S0022391304006158
    • Raigrodski AJ,. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004; 92: 557-562. (Pubitemid 39593586)
    • (2004) Journal of Prosthetic Dentistry , vol.92 , Issue.6 , pp. 557-562
    • Raigrodski, A.J.1
  • 9
    • 57449084616 scopus 로고    scopus 로고
    • High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations
    • Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D,. High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings-a new fabrication mode for all-ceramic restorations. Dent Mater 2009; 25: 121-128.
    • (2009) Dent Mater , vol.25 , pp. 121-128
    • Beuer, F.1    Schweiger, J.2    Eichberger, M.3    Kappert, H.F.4    Gernet, W.5    Edelhoff, D.6
  • 10
    • 38349192796 scopus 로고    scopus 로고
    • State of the art of zirconia for dental applications
    • Denry I, Kelly JR,. State of the art of zirconia for dental applications. Dent Mater 2008; 24: 299-307.
    • (2008) Dent Mater , vol.24 , pp. 299-307
    • Denry, I.1    Kelly, J.R.2
  • 13
    • 0034441675 scopus 로고    scopus 로고
    • Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness
    • Wakabayashi N, Anusavice KJ,. Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate thickness. J Dent Res 2000; 79: 1398-1404. (Pubitemid 32489447)
    • (2000) Journal of Dental Research , vol.79 , Issue.6 , pp. 1398-1404
    • Wakabayashi, N.1    Anusavice, K.J.2
  • 15
    • 7444265287 scopus 로고    scopus 로고
    • In vitro fracture strength of teeth restored with different all-ceramic crown systems
    • DOI 10.1016/j.prosdent.2004.09.001, PII S0022391304005840
    • Potiket N, Chiche G, Finger IM,. In vitro fracture strength of teeth restored with different all-ceramic crown systems. J Prosthet Dent 2004; 92: 491-495. (Pubitemid 39446463)
    • (2004) Journal of Prosthetic Dentistry , vol.92 , Issue.5 , pp. 491-495
    • Potiket, N.1    Chiche, G.2    Finger, I.M.3
  • 16
    • 30344479444 scopus 로고    scopus 로고
    • Factorial analysis of variables influencing stress in all-ceramic crowns
    • DOI 10.1016/j.dental.2005.04.010, PII S0109564105001399
    • Rekow ED, Harsono M, Janal M, Thompson VP, Zhang G,. Factorial analysis of variables influencing stress in all ceramic crowns. Dent Mater 2006; 22: 125-132. (Pubitemid 43061311)
    • (2006) Dental Materials , vol.22 , Issue.2 , pp. 125-132
    • Rekow, E.D.1    Harsono, M.2    Janal, M.3    Thompson, V.P.4    Zhang, G.5
  • 17
    • 0034132550 scopus 로고    scopus 로고
    • Survival of in Ceram crowns in a private practice: A prospective clinical trial
    • McLaren EA, White SN,. Survival of In Ceram crowns in a private practice: a prospective clinical trial. J Prosthet Dent 2000; 83: 216-222.
    • (2000) J Prosthet Dent , vol.83 , pp. 216-222
    • McLaren, E.A.1    White, S.N.2
  • 18
  • 20
    • 63149159375 scopus 로고    scopus 로고
    • Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments
    • Kim S, Kim HL, Brewer JD, Monaco EA Jr,. Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments. J Prosthet Dent 2009; 101: 226-230.
    • (2009) J Prosthet Dent , vol.101 , pp. 226-230
    • Kim, S.1    Kim, H.L.2    Brewer, J.D.3    Monaco, Jr.E.A.4
  • 21
    • 33746917163 scopus 로고    scopus 로고
    • Clinical long-term results of VITA In-Ceram Classic crowns and fixed partial dentures: A systematic literature review
    • Wassermann A, Kaiser M, Strub JR,. Clinical long-term results of VITA In-Ceram Classic crowns and fixed partial dentures: a systematic literature review. Int J Prosthodont 2006; 19: 355-363. (Pubitemid 44197789)
    • (2006) International Journal of Prosthodontics , vol.19 , Issue.4 , pp. 355-363
    • Wassermann, A.1    Kaiser, M.2    Strub, J.R.3
  • 23
    • 0034441675 scopus 로고    scopus 로고
    • Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness
    • Wakabayashi N, Anusavice KJ,. Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness. J Dent Res 2000; 79: 1398-1404. (Pubitemid 32489447)
    • (2000) Journal of Dental Research , vol.79 , Issue.6 , pp. 1398-1404
    • Wakabayashi, N.1    Anusavice, K.J.2
  • 24
    • 0034252034 scopus 로고    scopus 로고
    • Ceramic design concepts based on stress distribution analysis
    • Esquivel-Upshaw JF, Anusavice KJ,. Ceramic design concepts based on stress distribution analysis. Compend Contin Educ Dent 2000; 21: 649-652.
    • (2000) Compend Contin Educ Dent , vol.21 , pp. 649-652
    • Esquivel-Upshaw, J.F.1    Anusavice, K.J.2
  • 25
    • 43049090522 scopus 로고    scopus 로고
    • Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries
    • DOI 10.1016/j.dental.2007.08.008, PII S0109564107002096
    • Dehoff PH, Barrett AA, Lee RB, Anusavice KJ,. Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries. Dent Mater 2008; 24: 744-752. (Pubitemid 351626156)
    • (2008) Dental Materials , vol.24 , Issue.6 , pp. 744-752
    • DeHoff, P.H.1    Barrett, A.A.2    Lee, R.B.3    Anusavice, K.J.4
  • 26
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • DOI 10.1016/S0142-9612(98)00010-6, PII S0142961298000106
    • Piconi C, Maccauro G,. Zirconia as a ceramic biomaterial. Biomaterial 1999; 20: 1-25. (Pubitemid 29002541)
    • (1999) Biomaterials , vol.20 , Issue.1 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 27
    • 35148891671 scopus 로고    scopus 로고
    • An overview of zirconia ceramics: Basic properties and clinical applications
    • Manicone PF, Rossi Iommetti P, Raffaelli L,. An overview of zirconia ceramics: basic properties and clinical applications. J Dent 2007; 35: 819-826.
    • (2007) J Dent , vol.35 , pp. 819-826
    • Manicone, P.F.1    Rossi Iommetti, P.2    Raffaelli, L.3
  • 28
    • 35548931084 scopus 로고    scopus 로고
    • Fracture strength of all-ceramic posterior inlay-retained fixed partial dentures
    • DOI 10.1016/j.dental.2006.12.006, PII S0109564107000310
    • Wolfart S, Ludwig K, Uphaus A, Kern M,. Fracture strength of all-ceramic posterior inlay-retained fixed partial dentures. Dent Mater 2007; 23: 1513-1520. (Pubitemid 350018862)
    • (2007) Dental Materials , vol.23 , Issue.12 , pp. 1513-1520
    • Wolfart, S.1    Ludwig, K.2    Uphaus, A.3    Kern, M.4
  • 30
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: A systematic review
    • Conrad HJ, Seong WJ, Pesun IJ,. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 2007; 98: 389-404.
    • (2007) J Prosthet Dent , vol.98 , pp. 389-404
    • Conrad, H.J.1    Seong, W.J.2    Pesun, I.J.3
  • 31
    • 40049089519 scopus 로고    scopus 로고
    • Customization of milled zirconia copings for all-ceramic crowns: A clinical report
    • Marchack BW, Futatsuki Y, Marchack CB, White SN,. Customization of milled zirconia copings for all-ceramic crowns: a clinical report. J Prosthet Dent 2008; 99: 169-173.
    • (2008) J Prosthet Dent , vol.99 , pp. 169-173
    • Marchack, B.W.1    Futatsuki, Y.2    Marchack, C.B.3    White, S.N.4
  • 32
    • 0141924651 scopus 로고    scopus 로고
    • Influence of core thickness on a restored crown of a first premolar using finite element analysis
    • Proos KA, Swain MV, Ironside J, Steven GP,. Influence of core thickness on a restored crown of a first premolar using finite element analysis. Int J Prosthodont 2003; 16: 474-480. (Pubitemid 37229697)
    • (2003) International Journal of Prosthodontics , vol.16 , Issue.5 , pp. 474-480
    • Proos, K.A.1    Swain, M.V.2    Ironside, J.3    Steven, G.P.4
  • 34
    • 12344276485 scopus 로고    scopus 로고
    • The effect of core:dentin thickness ratio on the bi-axial flexure strength and fracture mode and origin of bilayered dental ceramic composites
    • DOI 10.1016/j.dental.2004.01.005, PII S0109564104000466
    • Fleming GJ, El-Lakwah SF, Harris JJ, Marquis PM,. The effect of core: dentin thickness ratio on the bi-axial flexure strength and fracture mode and origin of bilayered dental ceramic composites. Dent Mater 2005; 21: 164-171. (Pubitemid 40135744)
    • (2005) Dental Materials , vol.21 , Issue.2 , pp. 164-171
    • Fleming, G.J.P.1    El-Lakwah, S.F.A.2    Harris, J.J.3    Marquis, P.M.4
  • 35
    • 58749089146 scopus 로고    scopus 로고
    • The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading
    • Shirakura A, Lee H, Geminiani A, Ercoli C, Feng C,. The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading. J Prosthet Dent 2009; 101: 119-127.
    • (2009) J Prosthet Dent , vol.101 , pp. 119-127
    • Shirakura, A.1    Lee, H.2    Geminiani, A.3    Ercoli, C.4    Feng, C.5
  • 36
    • 0013122726 scopus 로고    scopus 로고
    • Mechanical properties
    • Craig R.G., Powers J.M., eds. In:. 11th edn. St Louis: Mosby.
    • Craig RG, Powers JM, eds. Mechanical properties. In: Restorative dental materials. 11th edn. St Louis: Mosby, 2002: 68-124.
    • (2002) Restorative Dental Materials , pp. 68-124


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.