메뉴 건너뛰기




Volumn 155, Issue 2, 2011, Pages 923-929

Low temperature co-fired ceramic (LTCC)-based biosensor for continuous glucose monitoring

Author keywords

Biosensor; CFD; Glucose; LTCC

Indexed keywords

CFD; COMPUTATIONAL FLUID DYNAMICS ANALYSIS; CONTINUOUS GLUCOSE MONITORING; DETECTION PROCESS; GLUCOSE CONCENTRATION; HIGH SENSITIVITY; LINEAR RESPONSE; LOW TEMPERATURE CO-FIRED CERAMICS; LTCC; MICRO-DIALYSIS; MICROREACTION CHAMBERS; OPERATING CONDITION; THICK-FILM ELECTRODES; WORKING ELECTRODE;

EID: 79957845126     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.01.002     Document Type: Article
Times cited : (19)

References (23)
  • 1
    • 0030175963 scopus 로고    scopus 로고
    • Glucose monitoring: State of the art and future possibilities
    • DOI 10.1016/1350-4533(95)00046-1
    • E. Wilkins, and P. Atanasov Glucose monitoring: state of the art and future possibilities Med. Eng. Phys. 18 4 1996 273 288 (Pubitemid 26185094)
    • (1996) Medical Engineering and Physics , vol.18 , Issue.4 , pp. 273-288
    • Wilkins, E.1    Atanasov, P.2
  • 2
    • 33751167207 scopus 로고    scopus 로고
    • Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats
    • DOI 10.1016/j.aca.2006.08.016, PII S0003267006017132
    • S. Woderer, N. Henninger, C.-D. Garthe, H.M. Kloetzer, M. Hajnsek, U. Kamecke, N. Gretz, B. Kraenzlin, and J. Pill Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats Anal. Chim. Acta 581 2007 7 12 (Pubitemid 44779519)
    • (2007) Analytica Chimica Acta , vol.581 , Issue.1 , pp. 7-12
    • Woderer, S.1    Henninger, N.2    Garthe, C.-D.3    Kloetzer, H.M.4    Hajnsek, M.5    Kamecke, U.6    Gretz, N.7    Kraenzlin, B.8    Pill, J.9
  • 3
    • 4344679385 scopus 로고    scopus 로고
    • Fluorescence glucose detection: Advances toward the ideal in vivo biosensor
    • E.A. Moschou, B.V. Sharma, S.K. Deo, and S. Daunert Fluorescence glucose detection: advances toward the ideal in vivo biosensor J. Fluoresc. 14 5 2004 535 546
    • (2004) J. Fluoresc. , vol.14 , Issue.5 , pp. 535-546
    • Moschou, E.A.1    Sharma, B.V.2    Deo, S.K.3    Daunert, S.4
  • 5
    • 0029053116 scopus 로고
    • Integrated implantable device for long-term glucose monitoring
    • E. Wilkins, P. Atanasov, and B.A. Muggenburg Integrated implantable device for long-term glucose monitoring Biosens. Bioelectron. 10 1995 485 494
    • (1995) Biosens. Bioelectron. , vol.10 , pp. 485-494
    • Wilkins, E.1    Atanasov, P.2    Muggenburg, B.A.3
  • 6
    • 0031278051 scopus 로고    scopus 로고
    • A microflow amperometric glucose biosensor
    • DOI 10.1016/S0956-5663(97)00018-3, PII S0956566397000183
    • B.C. Towe, and V.B. Pizziconi A microflow amperometric glucose biosensor Biosens. Bioelectron. 12 9-10 1997 893 899 (Pubitemid 28067998)
    • (1997) Biosensors and Bioelectronics , vol.12 , Issue.9-10 , pp. 893-899
    • Towe, B.C.1    Pizziconi, V.B.2
  • 9
    • 29944443113 scopus 로고    scopus 로고
    • Electrochemical non-enzymatic glucose sensor
    • S. Park, H. Boo, and T. Dong Chung Electrochemical non-enzymatic glucose sensor Anal. Chim. Acta 556 2006 46 57
    • (2006) Anal. Chim. Acta , vol.556 , pp. 46-57
    • Park, S.1    Boo, H.2    Dong Chung, T.3
  • 10
    • 72949121244 scopus 로고    scopus 로고
    • A review of microdialysis sampling system
    • N. Torto A review of microdialysis sampling system Chromatographia 70 2009 1305 1309
    • (2009) Chromatographia , vol.70 , pp. 1305-1309
    • Torto, N.1
  • 11
    • 0035871550 scopus 로고    scopus 로고
    • Overview of low temperature co-fired ceramics tape technology for meso-system technology (MsST)
    • DOI 10.1016/S0924-4247(00)00554-9, PII S0924424700005549
    • M.R. Gongora-Rubio, P. Espinoza-Vallejos, L.M. Sola-Laguna, and J.J. Santiago-Aviles Overview of low temperature co-fired ceramics tape technology for meso-system technology (MsST) Sens. Actuators A: Phys. 89 2001 222 241 (Pubitemid 32296915)
    • (2001) Sensors and Actuators, A: Physical , vol.89 , Issue.3 , pp. 222-241
    • Gongora-Rubio, M.R.1    Espinoza-Vallejos, P.2    Sola-Laguna, L.3    Santiago-Aviles, J.J.4
  • 12
    • 33745801593 scopus 로고    scopus 로고
    • Technology and applications of Low Temperature Cofired Ceramic (LTCC) based sensors and microsystems
    • L.J. Golonka Technology and applications of low temperature cofired ceramic (LTCC) based sensors and microsystems Bull. Pol. Acad. Sci. Tech. Sci. 54 2 2006 221 231 (Pubitemid 44020779)
    • (2006) Bulletin of the Polish Academy of Sciences: Technical Sciences , vol.54 , Issue.2 , pp. 221-231
    • Golonka, L.J.1
  • 13
    • 0030240480 scopus 로고    scopus 로고
    • A comparative study of the activity of free and immobilized enzymes and its application to glucose isomerase
    • F. Camacho-Rubio, E. Jurado-Alameda, P. Gonzalez-Tello, and G. Luzon Gonzalez A comparative study of the activity of free and immobilized enzymes and its application to glucose isomerase Chem. Eng. Sci. 51 17 1996 4159 4165
    • (1996) Chem. Eng. Sci. , vol.51 , Issue.17 , pp. 4159-4165
    • Camacho-Rubio, F.1    Jurado-Alameda, E.2    Gonzalez-Tello, P.3    Luzon Gonzalez, G.4
  • 15
    • 0034902195 scopus 로고    scopus 로고
    • A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors
    • DOI 10.1016/S0956-5663(01)00153-1, PII S0956566301001531
    • S. Böhm, D.G. Pijanowska, W. Olthuis, and P. Bergveld A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors Biosens. Bioelectron. 16 2001 391 397 (Pubitemid 32728161)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.6 , pp. 391-397
    • Bohm, S.1    Pijanowska, D.2    Olthuis, W.3    Bergveld, P.4
  • 17
    • 39149145836 scopus 로고    scopus 로고
    • Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems
    • N. Ibanez-Garcia, C.S. Martinez-Cisneros, F. Valdes, and J. Alonso Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems Trends Anal. Chem. 127 1 2008 24 33
    • (2008) Trends Anal. Chem. , vol.127 , Issue.1 , pp. 24-33
    • Ibanez-Garcia, N.1    Martinez-Cisneros, C.S.2    Valdes, F.3    Alonso, J.4
  • 18
    • 77449096564 scopus 로고    scopus 로고
    • High temperature LTCC package for SiC-based gas sensor
    • D. Nowak, D. Kulczak, M. Januszkiewicz, and A. Dziedzic High temperature LTCC package for SiC-based gas sensor Opt. Appl. 39 4 2009 701 704
    • (2009) Opt. Appl. , vol.39 , Issue.4 , pp. 701-704
    • Nowak, D.1    Kulczak, D.2    Januszkiewicz, M.3    Dziedzic, A.4
  • 21
    • 0036398746 scopus 로고    scopus 로고
    • Laser treatment of LTCC for 3D structures and elements fabrication
    • DOI 10.1108/13565360210444998
    • J. Kita, A. Dziedzic, L.J. Golonka, and T. Zawada Laser treatment of LTCC for 3D structures and elements Microelectron. Int. 19 2002 14 18 (Pubitemid 35196068)
    • (2002) Microelectronics International , vol.19 , Issue.3 , pp. 14-18
    • Kita, J.1    Dziedzic, A.2    Golonka, L.J.3    Zawada, T.4
  • 22
    • 45849103508 scopus 로고    scopus 로고
    • Microchannel fabrication process in LTCC ceramics
    • K. Malecha, and L.J. Golonka Microchannel fabrication process in LTCC ceramics Microelectron. Reliab. 48 2008 866 871
    • (2008) Microelectron. Reliab. , vol.48 , pp. 866-871
    • Malecha, K.1    Golonka, L.J.2
  • 23
    • 70350641546 scopus 로고    scopus 로고
    • A PDMS/LTCC bonding technique for microfluidic application
    • K. Malecha, I. Gancarz, and L.J. Golonka A PDMS/LTCC bonding technique for microfluidic application J. Micromech. Microeng. 19 2009 105016.1 105016.8
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 1050161-1050168
    • Malecha, K.1    Gancarz, I.2    Golonka, L.J.3