메뉴 건너뛰기




Volumn 18, Issue 4, 1996, Pages 273-288

Glucose monitoring: State of the art and future possibilities

Author keywords

biosensor; diabetes mellitus; enzyme electrodes; Glucose monitoring; glucose sensors; implantable sensors

Indexed keywords

DISEASES; ENZYME SENSORS; IMPLANTS (SURGICAL); PATIENT MONITORING; PHYSIOLOGY;

EID: 0030175963     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/1350-4533(95)00046-1     Document Type: Review
Times cited : (157)

References (189)
  • 1
    • 0342555043 scopus 로고
    • Symposium on implantable glucose biosensors
    • Symposium on implantable glucose biosensors. Diabetes Care 1982; 5: 1-216.
    • (1982) Diabetes Care , vol.5 , pp. 1-216
  • 2
    • 0025318152 scopus 로고
    • Diabetes control and complications trial (DCCT) update
    • The DCCT research group, including Schade DS. Diabetes control and complications trial (DCCT) update. Diabetes Care 1990; 13: 427-33.
    • (1990) Diabetes Care , vol.13 , pp. 427-433
    • Schade, D.S.1
  • 3
    • 0027424767 scopus 로고
    • Blood glucose monitoring: Does technology help?
    • Page SR, Peacock I. Blood glucose monitoring: does technology help? Diabetic Med 1993; 10: 793-801.
    • (1993) Diabetic Med , vol.10 , pp. 793-801
    • Page, S.R.1    Peacock, I.2
  • 4
    • 0025849027 scopus 로고
    • Fundamentals of glucose sensors
    • Fischer U, Fundamentals of glucose sensors. Diabetic Med 1991; 8: 309-21.
    • (1991) Diabetic Med , vol.8 , pp. 309-321
    • Fischer, U.1
  • 5
    • 0022388532 scopus 로고
    • Biosensors: A clinical perspective
    • Pickup LC. Biosensors: a clinical perspective. Lancet 1985; 2: 817-20.
    • (1985) Lancet , vol.2 , pp. 817-820
    • Pickup, L.C.1
  • 6
    • 0023666995 scopus 로고
    • Biosensors in process control
    • Clarke DJ. Biosensors in process control. Phil Trans R Soc London 1987; B316: 169-81.
    • (1987) Phil Trans R Soc London , vol.B316 , pp. 169-181
    • Clarke, D.J.1
  • 7
    • 0023569872 scopus 로고
    • Biosensors in food industry
    • Karube I, Tamiya E. Biosensors in food industry. Food Biotechnol 1987; 1: 147-56.
    • (1987) Food Biotechnol , vol.1 , pp. 147-156
    • Karube, I.1    Tamiya, E.2
  • 8
    • 0027284774 scopus 로고
    • Blood glucose and glycated haemoglobin measurement in hospital: Which method?
    • Pickup JC, Crook MA, Tutt P. Blood glucose and glycated haemoglobin measurement in hospital: which Method? Diabetic Med 1993; 10: 402-11.
    • (1993) Diabetic Med , vol.10 , pp. 402-411
    • Pickup, J.C.1    Crook, M.A.2    Tutt, P.3
  • 9
    • 0018618568 scopus 로고
    • Laser absorption spectroscopy with an ATR prism-noninvasive in vitro determination of glucose
    • Kaiser N. Laser absorption spectroscopy with an ATR prism-noninvasive in vitro determination of glucose. Horm Metab Res Supl Ser 1979; 8: 30-3.
    • (1979) Horm Metab Res Supl Ser , vol.8 , pp. 30-33
    • Kaiser, N.1
  • 10
    • 0026726013 scopus 로고
    • Near-infrared spectrophotometry: A new dimension in clinical chemistry
    • Hall JW, Pollard A. Near-infrared spectrophotometry: a new dimension in clinical chemistry. Clin Chem 1992; 38: 1623-31.
    • (1992) Clin Chem , vol.38 , pp. 1623-1631
    • Hall, J.W.1    Pollard, A.2
  • 11
    • 0028309433 scopus 로고
    • Noninvasive blood glucose sensors based on near-infrared spectroscopy
    • Gries FA, Heise HM, Marbach R. Noninvasive blood glucose sensors based on near-infrared spectroscopy. Artificial Organs 1994; 18: 439-44.
    • (1994) Artificial Organs , vol.18 , pp. 439-444
    • Gries, F.A.1    Heise, H.M.2    Marbach, R.3
  • 12
    • 85165634569 scopus 로고
    • Reagentless near-infrared determination of glucose in whole blood using multivariable calibration
    • Haaland DM, Robinson MR, Koepp GW, Thomas EV, Eaton RP. Reagentless near-infrared determination of glucose in whole blood using multivariable calibration. Applied Spectroscopy 1992; 46: 1575-8.
    • (1992) Applied Spectroscopy , vol.46 , pp. 1575-1578
    • Haaland, D.M.1    Robinson, M.R.2    Koepp, G.W.3    Thomas, E.V.4    Eaton, R.P.5
  • 13
    • 0000073110 scopus 로고
    • Post-prandial blood glucose determunation by quantitative mid-infrared spectroscopy
    • Ward KJ, Haaland DM, Robinson MR, Eaton RP. Post-prandial blood glucose determunation by quantitative mid-infrared spectroscopy. Applied Spectroscopy 1992; 46: 959-65.
    • (1992) Applied Spectroscopy , vol.46 , pp. 959-965
    • Ward, K.J.1    Haaland, D.M.2    Robinson, M.R.3    Eaton, R.P.4
  • 15
    • 0028405316 scopus 로고
    • Temperature-insensitive spectroscopic measurement of glucose in aqueous solutions
    • Hazen KH, Arnold MA, Small GW. Temperature-insensitive spectroscopic measurement of glucose in aqueous solutions. Applied Spectroscopy 1994; 48: 477-83.
    • (1994) Applied Spectroscopy , vol.48 , pp. 477-483
    • Hazen, K.H.1    Arnold, M.A.2    Small, G.W.3
  • 16
    • 0027918323 scopus 로고
    • Near-infrared spectroscopic measurement of glucose in a protein matrix
    • Marquardt LA, Arnold MA, Small GW. Near-infrared spectroscopic measurement of glucose in a protein matrix. Anal Chem 1993; 65: 3271-8.
    • (1993) Anal Chem , vol.65 , pp. 3271-3278
    • Marquardt, L.A.1    Arnold, M.A.2    Small, G.W.3
  • 17
    • 0027918243 scopus 로고
    • Strategies for coupling digital filtering with partial least-squares regression: Application to the determination of glucose in plasma by fourier transform near-infrared spectroscopy
    • Small GW, Arnold MA, Marquardt LA. Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by fourier transform near-infrared spectroscopy. Anal Chem 1993; 65: 3279-89.
    • (1993) Anal Chem , vol.65 , pp. 3279-3289
    • Small, G.W.1    Arnold, M.A.2    Marquardt, L.A.3
  • 18
    • 84891711974 scopus 로고
    • Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip
    • Marbach R, Koschinsky Th, Gries FA, Heise HM. Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip. Applied Spectroscopy 1993; 47: 875-81.
    • (1993) Applied Spectroscopy , vol.47 , pp. 875-881
    • Marbach, R.1    Koschinsky, Th.2    Gries, F.A.3    Heise, H.M.4
  • 19
    • 0027624283 scopus 로고
    • Noninvasive measurement of blood glucose concentrations by analysing fourier transform infra-red absorbance spectra through oral mucosa
    • Kajiwara K, Uemura T, Kishikawa H. Noninvasive measurement of blood glucose concentrations by analysing fourier transform infra-red absorbance spectra through oral mucosa. Med Biol Eng Comput 1993; 31: S17.
    • (1993) Med Biol Eng Comput , vol.31
    • Kajiwara, K.1    Uemura, T.2    Kishikawa, H.3
  • 21
    • 84990575113 scopus 로고
    • Non-invasive in vivo glucose measurements
    • Guilbault G. Non-invasive in vivo glucose measurements. Artificial Organs 1988; 13: 172.
    • (1988) Artificial Organs , vol.13 , pp. 172
    • Guilbault, G.1
  • 25
    • 0026470689 scopus 로고
    • Biosensors: Recent trends: A review
    • Vadgama P, Crump PW. Biosensors: recent trends: a review. Analyst 1992; 117: 1657-70.
    • (1992) Analyst , vol.117 , pp. 1657-1670
    • Vadgama, P.1    Crump, P.W.2
  • 26
    • 0027242259 scopus 로고
    • Biosensors in clinical biochemistry
    • Vadgama P. Biosensors in clinical biochemistry. Ann Clin Biochem 1993; 30: 337-40.
    • (1993) Ann Clin Biochem , vol.30 , pp. 337-340
    • Vadgama, P.1
  • 27
    • 0021491386 scopus 로고
    • Review - Technology and the diabetic patient
    • Pickup JC, Rothwell D. Review - Technology and the diabetic patient. Med Biol Eng Comput 1984; 22: 384-400.
    • (1984) Med Biol Eng Comput , vol.22 , pp. 384-400
    • Pickup, J.C.1    Rothwell, D.2
  • 28
    • 0022269013 scopus 로고
    • Diabetes mellitus: Biosensors for research and management
    • Turner APF, Pickup JC. Diabetes mellitus: biosensors for research and management. Biosensors 1985; 1: 85-115.
    • (1985) Biosensors , vol.1 , pp. 85-115
    • Turner, A.P.F.1    Pickup, J.C.2
  • 29
    • 0027411735 scopus 로고
    • In vivo glucose monitoring: Sense and sensorbility
    • Pickup JC. In vivo glucose monitoring: sense and sensorbility. Diabetes Care 1993; 16: 535-9.
    • (1993) Diabetes Care , vol.16 , pp. 535-539
    • Pickup, J.C.1
  • 30
    • 10244223555 scopus 로고
    • Electrode system for continuous monitoring in cardiovascular surgery
    • Clark LC, Lyons C. Electrode system for continuous monitoring in cardiovascular surgery. Ann NY Acad Sci 1962; 102: 29-45.
    • (1962) Ann NY Acad Sci , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 31
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike SJ, Hicks GP. The enzyme electrode. Nature 1967; 214: 986-8.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, G.P.2
  • 32
    • 0017627616 scopus 로고
    • The characteristics of a new glucose sensor for use in artificial beta cell
    • Clark LC, Santiago J. The characteristics of a new glucose sensor for use in artificial beta cell. Artif Organs 1977; 1: 78-82.
    • (1977) Artif Organs , vol.1 , pp. 78-82
    • Clark, L.C.1    Santiago, J.2
  • 33
    • 0342555031 scopus 로고
    • Stable continuous signal from blood glucose enzyme anode system
    • Clark LC, Grooms TG. Stable continuous signal from blood glucose enzyme anode system. Artif Organs 1980; 3: 272-9.
    • (1980) Artif Organs , vol.3 , pp. 272-279
    • Clark, L.C.1    Grooms, T.G.2
  • 34
    • 0020134817 scopus 로고
    • Implanted electroenzymated glucose sensors
    • Clark LC, Duggon C. Implanted electroenzymated glucose sensors. Diabetes Care 1982; 5: 174-80.
    • (1982) Diabetes Care , vol.5 , pp. 174-180
    • Clark, L.C.1    Duggon, C.2
  • 35
    • 0023676677 scopus 로고
    • Long-term implantation of voltammetric oxidase/peroxidase glucose sensors in rat peritoneum
    • Clark LC, Noyes LK, Okane RBS, Sudan R, Muller M. Long-term implantation of voltammetric oxidase/peroxidase glucose sensors in rat peritoneum. Methods in Enzymology 1988; 137: 68-89.
    • (1988) Methods in Enzymology , vol.137 , pp. 68-89
    • Clark, L.C.1    Noyes, L.K.2    Okane, R.B.S.3    Sudan, R.4    Muller, M.5
  • 36
    • 0018715685 scopus 로고
    • Continuous glucose monitor based on an immobilized enzyme electrode detector
    • Updike SJ, Scults MC, Busby M. Continuous glucose monitor based on an immobilized enzyme electrode detector. J Lab Clin Med 1979; 93: 518-27.
    • (1979) J Lab Clin Med , vol.93 , pp. 518-527
    • Updike, S.J.1    Scults, M.C.2    Busby, M.3
  • 37
    • 0020058620 scopus 로고
    • Implanting the glucose enzyme electrode: Problems, progress and alternative solutions
    • Updike SJ, Scults MC, Ekman BO. Implanting the glucose enzyme electrode: problems, progress and alternative solutions. Diabetes Care 1982, 5: 207-17.
    • (1982) Diabetes Care , vol.5 , pp. 207-217
    • Updike, S.J.1    Scults, M.C.2    Ekman, B.O.3
  • 41
    • 0028106630 scopus 로고
    • Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
    • Gilligan BJ, Scults MC, Rhodes RK, Updike SJ. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care 1994; 17: 882-7.
    • (1994) Diabetes Care , vol.17 , pp. 882-887
    • Gilligan, B.J.1    Scults, M.C.2    Rhodes, R.K.3    Updike, S.J.4
  • 42
    • 0023131817 scopus 로고
    • On the way to automated (blood) glucose regulation in diabetes: The dark past, the grey present and the rosy future
    • Pfeiffer EF. On the way to automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosy future. Diabetologia 1987; 30: 51-65.
    • (1987) Diabetologia , vol.30 , pp. 51-65
    • Pfeiffer, E.F.1
  • 43
    • 0023482117 scopus 로고
    • Implantable glucose sensors: Choosing the appropriate sensing strategy
    • Pickup JC, Show GW, Claremont JD. Implantable glucose sensors: choosing the appropriate sensing strategy. Biosensors 1987/88; 3: 335-46.
    • (1987) Biosensors , vol.3 , pp. 335-346
    • Pickup, J.C.1    Show, G.W.2    Claremont, J.D.3
  • 44
    • 0020402631 scopus 로고
    • Wearable artificial endocrine pancreas with needle-type glucose sensor
    • Shichiri M, Kawamori R, Yamasaki Y, Hakui N, Abe H. Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet 1982; 20: 1129-31.
    • (1982) Lancet , vol.20 , pp. 1129-1131
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3    Hakui, N.4    Abe, H.5
  • 46
    • 0021747298 scopus 로고
    • Closed loop glycemic control with a wearable artificial endocrine pancreas
    • Shichiri M, Kawamori R, Hakui N, Yamasaki Y, Abe H. Closed loop glycemic control with a wearable artificial endocrine pancreas. Diabetes 1984; 33: 1200-2.
    • (1984) Diabetes , vol.33 , pp. 1200-1202
    • Shichiri, M.1    Kawamori, R.2    Hakui, N.3    Yamasaki, Y.4    Abe, H.5
  • 47
    • 0021228204 scopus 로고
    • The development of wearable-type artificial endocrine pancreas and its usefulness in glycemic control of human diabetes mellitus
    • Shichiri M, Kawamori R, Hakui N, Asakawa N, Yamasaki Y, Abe H. The development of wearable-type artificial endocrine pancreas and its usefulness in glycemic control of human diabetes mellitus. Biomed Biochim Acta 1984; 43: 561-8.
    • (1984) Biomed Biochim Acta , vol.43 , pp. 561-568
    • Shichiri, M.1    Kawamori, R.2    Hakui, N.3    Asakawa, N.4    Yamasaki, Y.5    Abe, H.6
  • 48
    • 0342555027 scopus 로고
    • The glucose sensor: Present and future
    • Eds Baba S, Gould M, Zimmet P. Academic Press, New York
    • Shichiri M, Kawamori R, Yamasaki Y, Hakui N, Abe H. The glucose sensor: present and future. In Diabetes Mellitus. Eds Baba S, Gould M, Zimmet P. Academic Press, New York, 1984; 177-84.
    • (1984) Diabetes Mellitus , pp. 177-184
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3    Hakui, N.4    Abe, H.5
  • 50
    • 0019747440 scopus 로고
    • Trial of new vessel access type glucose sensor for implantable artificial pancreas in vivo
    • Kondo T, Kojima H, Ohkura K, Ikeda S, Ito K. Trial of new vessel access type glucose sensor for implantable artificial pancreas in vivo. Trans Am Soc Artif Internal Organs 1981; 27: 250-3.
    • (1981) Trans Am Soc Artif Internal Organs , vol.27 , pp. 250-253
    • Kondo, T.1    Kojima, H.2    Ohkura, K.3    Ikeda, S.4    Ito, K.5
  • 51
    • 0020039884 scopus 로고
    • A miniature glucose sensor implantable in the blood stream
    • Kondo T, Ohkura K, Ito K, Ikeda S. A miniature glucose sensor implantable in the blood stream. Diabetes Care 1982; 5: 218-21.
    • (1982) Diabetes Care , vol.5 , pp. 218-221
    • Kondo, T.1    Ohkura, K.2    Ito, K.3    Ikeda, S.4
  • 52
    • 0022873671 scopus 로고
    • Development of subcutaneous-type glucose sensor for implantable portable artificial pancreas
    • Fundamentals and Applications of Chemical Sensors. Eds Schuetzle D, Hamerle R, Butles JW. Washington DC
    • Ito K, Ikeda S, Asai K, Naruse H, Ohkura K, Ichihasi H, Kamei H, Kondo T. Development of subcutaneous-type glucose sensor for implantable portable artificial pancreas. In Fundamentals and Applications of Chemical Sensors. Eds Schuetzle D, Hamerle R, Butles JW. Am Chem Soc, Washington DC. 1986; 271-382.
    • (1986) Am Chem Soc , pp. 271-382
    • Ito, K.1    Ikeda, S.2    Asai, K.3    Naruse, H.4    Ohkura, K.5    Ichihasi, H.6    Kamei, H.7    Kondo, T.8
  • 53
    • 0020072833 scopus 로고
    • Problems in adapting a glucose oxidase electrochemical sensor into an implantable glucose sensing device
    • Thevenot DR. Problems in adapting a glucose oxidase electrochemical sensor into an implantable glucose sensing device. Diabetes Care 1982; 5: 184-9.
    • (1982) Diabetes Care , vol.5 , pp. 184-189
    • Thevenot, D.R.1
  • 54
    • 0043182340 scopus 로고
    • The design and development of in vivo glucose sensor for an artificial endocrine pancreas
    • Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford
    • Velho G, Reach G, Thevenot DR. The design and development of in vivo glucose sensor for an artificial endocrine pancreas. In Biosensors: Fundamentals And Applications. Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford, 1987; 390-409.
    • (1987) Biosensors: Fundamentals And Applications , pp. 390-409
    • Velho, G.1    Reach, G.2    Thevenot, D.R.3
  • 55
    • 0021148018 scopus 로고
    • Experience with implantable glucose sensors as a prequisite of an artificial beta cell
    • Abel P, Muller A, Fisher U. Experience with implantable glucose sensors as a prequisite of an artificial beta cell. Biomed Biochim Acta 1984; 43: 577-84.
    • (1984) Biomed Biochim Acta , vol.43 , pp. 577-584
    • Abel, P.1    Muller, A.2    Fisher, U.3
  • 56
    • 0025327060 scopus 로고
    • The glucose unitec ulm - A portable monitor for continuous blood glucose measurement
    • Bruckel J, Zeir H, Kerner W, Pfeiffer EF. The glucose unitec ulm - a portable monitor for continuous blood glucose measurement. Horm Met Res 1990; 22: 382-4.
    • (1990) Horm Met Res , vol.22 , pp. 382-384
    • Bruckel, J.1    Zeir, H.2    Kerner, W.3    Pfeiffer, E.F.4
  • 57
    • 0022485273 scopus 로고
    • Telemetry glucose monitoring device with needle glucose sensor: A useful tool for blood glucose monitoring in diabetic individuals
    • Shichiri M, Asasawa N, Yamasaki Y, Kawamori R, Abe H. Telemetry glucose monitoring device with needle glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals. Diabetes Care 1986; 9: 298-301.
    • (1986) Diabetes Care , vol.9 , pp. 298-301
    • Shichiri, M.1    Asasawa, N.2    Yamasaki, Y.3    Kawamori, R.4    Abe, H.5
  • 61
    • 0026354548 scopus 로고
    • Combination of microdialysis and glucosensor permits continuous (online) s.C. Glucose monitoring in a patient operated device: I. In vitro evaluation
    • Keck FS, Kerner W, Meyerhoff C, Zeir H, Pfeiffer EF. Combination of microdialysis and glucosensor permits continuous (online) s.c. glucose monitoring in a patient operated device: I. in vitro evaluation. Horm Met Res 1991; 23: 617-8.
    • (1991) Horm Met Res , vol.23 , pp. 617-618
    • Keck, F.S.1    Kerner, W.2    Meyerhoff, C.3    Zeir, H.4    Pfeiffer, E.F.5
  • 62
    • 0026733786 scopus 로고
    • Combination of microdialysis and glucosensor permits continuous (online) s.C. Glucose monitoring in a patient operated device: II. Evaluation in animals
    • Keck FS, Meyerhoff C, Kerner W, Siegmund T, Zeir H, Pfeiffer EF. Combination of microdialysis and glucosensor permits continuous (online) s.c. glucose monitoring in a patient operated device: II. evaluation in animals. Horm Met Res 1992; 24: 492-3.
    • (1992) Horm Met Res , vol.24 , pp. 492-493
    • Keck, F.S.1    Meyerhoff, C.2    Kerner, W.3    Siegmund, T.4    Zeir, H.5    Pfeiffer, E.F.6
  • 63
    • 0026761167 scopus 로고
    • Online continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis
    • Meyerhoff C, Bischof F, Sternberg F, Zeir H, Pfeiffer EF. Online continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis. Diabetologia 1992; 35: 1087-92.
    • (1992) Diabetologia , vol.35 , pp. 1087-1092
    • Meyerhoff, C.1    Bischof, F.2    Sternberg, F.3    Zeir, H.4    Pfeiffer, E.F.5
  • 64
    • 0027474090 scopus 로고    scopus 로고
    • Online continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
    • 993
    • Pfeiffer EF, Meyerhoff C, Bischof F, Keck FS, Kerner W. Online continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm Met Res 993; 25: 121-4.
    • Horm Met Res , vol.25 , pp. 121-124
    • Pfeiffer, E.F.1    Meyerhoff, C.2    Bischof, F.3    Keck, F.S.4    Kerner, W.5
  • 65
    • 0027684955 scopus 로고
    • Registration of dissolved glucose in vitro and in vivo by a combined microdialysis/amperometric method
    • Keck FS, Kerner W. Registration of dissolved glucose in vitro and in vivo by a combined microdialysis/amperometric method. Sensors & Actuators B 1993; 15-16: 435-8.
    • (1993) Sensors & Actuators B , vol.15-16 , pp. 435-438
    • Keck, F.S.1    Kerner, W.2
  • 66
    • 0000194375 scopus 로고
    • Subcutaneous microdialysis probe coupled with glucose biosensor for in vivo continuous monitoring
    • Moscone D, Pasini M, Mascini M. Subcutaneous microdialysis probe coupled with glucose biosensor for in vivo continuous monitoring. Talanta 1992; 39: 1039-44.
    • (1992) Talanta , vol.39 , pp. 1039-1044
    • Moscone, D.1    Pasini, M.2    Mascini, M.3
  • 67
    • 0026436446 scopus 로고
    • In vivo continuous monitoring of glucose by microdialysis and a glucose biosensor
    • Mascini M, Moscone D, Bernardi L. In vivo continuous monitoring of glucose by microdialysis and a glucose biosensor. Sensors & Actuators B 1992; 6: 143-5.
    • (1992) Sensors & Actuators B , vol.6 , pp. 143-145
    • Mascini, M.1    Moscone, D.2    Bernardi, L.3
  • 68
    • 0026744848 scopus 로고
    • Microdialysis and glucose biosensor for in vivo monitoring
    • Moscone D, Mascini M. Microdialysis and glucose biosensor for in vivo monitoring. Ann Biol Clin 1992; 50: 223-5.
    • (1992) Ann Biol Clin , vol.50 , pp. 223-225
    • Moscone, D.1    Mascini, M.2
  • 69
    • 0027757187 scopus 로고
    • An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling
    • Palmisano F, Centonze D, Gurrrieri A, Zombonin PG. An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling. Biosensors & Bioelectronics 1993; 8: 393-9.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 393-399
    • Palmisano, F.1    Centonze, D.2    Gurrrieri, A.3    Zombonin, P.G.4
  • 71
    • 0024421801 scopus 로고
    • Artificial or bioartificial systems for the totally automatic treatment of diabetes mellitus: The gap between the dream and the reality
    • Reach G. Artificial or bioartificial systems for the totally automatic treatment of diabetes mellitus: the gap between the dream and the reality. Diab Nutr Metab 1989; 2: 165-70.
    • (1989) Diab Nutr Metab , vol.2 , pp. 165-170
    • Reach, G.1
  • 72
    • 0026473430 scopus 로고
    • Biosensors for medical applications
    • Mascini M. Biosensors for medical applications. Sensors & Actuators B 1992; 6: 79-82.
    • (1992) Sensors & Actuators B , vol.6 , pp. 79-82
    • Mascini, M.1
  • 73
    • 84908830001 scopus 로고
    • Can continuous glucose monitoring be used for the treatment of diabetes
    • Reach G, Wilson GS. Can continuous glucose monitoring be used for the treatment of diabetes. Anal Chem 1992; 64: 381A-6A.
    • (1992) Anal Chem , vol.64
    • Reach, G.1    Wilson, G.S.2
  • 74
    • 0000794840 scopus 로고
    • Medical application of the glucose sensor and artificial pancreas
    • Ed. Seiyama T, Elsevier, Amsterdam
    • Shichiri M, Kawamory R, Yamasaki Y, Ueda N. Medical application of the glucose sensor and artificial pancreas. In Chemical Sensor Technology. Ed. Seiyama T, Elsevier, Amsterdam, 1988; 1: 209-43.
    • (1988) Chemical Sensor Technology , vol.1 , pp. 209-243
    • Shichiri, M.1    Kawamory, R.2    Yamasaki, Y.3    Ueda, N.4
  • 75
    • 33749019147 scopus 로고
    • In vivo chemical sensors and biosensors in clinical medicine
    • Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford
    • Claremont DJ, Pickup JC. In vivo chemical sensors and biosensors in clinical medicine. In Biosensors: fundamentals and Applications. Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford, 1987; 357-76.
    • (1987) Biosensors: Fundamentals and Applications , pp. 357-376
    • Claremont, D.J.1    Pickup, J.C.2
  • 76
    • 0002245404 scopus 로고
    • Glucose sensors and closed-loop insulin delivery
    • Ed. Pickup JC, Blackwell, Oxford
    • Pickup JC. Glucose sensors and closed-loop insulin delivery. In: Biotechnology of Insulin Therapy, Ed. Pickup JC, Blackwell, Oxford, 1991; 126-53.
    • (1991) Biotechnology of Insulin Therapy , pp. 126-153
    • Pickup, J.C.1
  • 77
    • 0026705465 scopus 로고
    • Implantable programable insulin pumps for the treatment of diabetes
    • Waxman K, Turner D, Nguen T. Implantable programable insulin pumps for the treatment of diabetes. Arch Surg 1992; 127: 1032-41.
    • (1992) Arch Surg , vol.127 , pp. 1032-1041
    • Waxman, K.1    Turner, D.2    Nguen, T.3
  • 78
    • 0026677605 scopus 로고
    • Implantable pumps: Resent progress and anticipated future advances
    • Buchwald H, Thomas TD. Implantable pumps: resent progress and anticipated future advances. Trans Amer Soc Artif Internal Organs 1992; 38: 772-7.
    • (1992) Trans Amer Soc Artif Internal Organs , vol.38 , pp. 772-777
    • Buchwald, H.1    Thomas, T.D.2
  • 79
    • 0027008267 scopus 로고
    • Insulin delivery by implantable pumps
    • Zoltobrocki M. Insulin delivery by implantable pumps. Horm Metab Res Supl Ser 1992; 26: 140-5.
    • (1992) Horm Metab Res Supl Ser , vol.26 , pp. 140-145
    • Zoltobrocki, M.1
  • 80
    • 0026480824 scopus 로고
    • Long term implantation of a new programmable implantable insulin oump
    • Scavini M, Day PW, Eaton RP. Long term implantation of a new programmable implantable insulin oump. Artif Organs 1992; 16: 518-22.
    • (1992) Artif Organs , vol.16 , pp. 518-522
    • Scavini, M.1    Day, P.W.2    Eaton, R.P.3
  • 81
    • 0003822419 scopus 로고
    • Oxford University Press. Oxford
    • Hall E. Biosensors. Oxford University Press. Oxford. 1990.
    • (1990) Biosensors
    • Hall, E.1
  • 83
    • 0024731147 scopus 로고
    • Towards implantable glucose sensors: A review
    • Wilkins E. Towards implantable glucose sensors: a review. J Biomed Eng 1989; 11: 353-61.
    • (1989) J Biomed Eng , vol.11 , pp. 353-361
    • Wilkins, E.1
  • 84
    • 0015217761 scopus 로고
    • The glucose oxidase mechanism
    • Weibel MK, Bright HJ. The glucose oxidase mechanism. J Biol Chem 1971; 246: 2743-4.
    • (1971) J Biol Chem , vol.246 , pp. 2743-2744
    • Weibel, M.K.1    Bright, H.J.2
  • 86
    • 0014698380 scopus 로고
    • Development of an ion-selective solid-state device for neuro-physiologicsl measurements
    • Bergveld P. Development of an ion-selective solid-state device for neuro-physiologicsl measurements. IEEE Trans Biomed Eng 1970; 17; 70-1.
    • (1970) IEEE Trans Biomed Eng , vol.17 , pp. 70-71
    • Bergveld, P.1
  • 87
    • 0003084656 scopus 로고
    • Conductimetric and impedimetric devices
    • In Cass AEG (ed.) Oxford University Press, Oxford
    • Kell DB, Davey CL. Conductimetric and impedimetric devices. In Cass AEG (ed.) Biosensors, A Practical Approach. Oxford University Press, Oxford, 1990; 125-55.
    • (1990) Biosensors, A Practical Approach , pp. 125-155
    • Kell, D.B.1    Davey, C.L.2
  • 89
    • 0015622550 scopus 로고
    • An enzyme electrode for amperometric determination of glucose and lactate
    • Guilbault GG, Lubrano GJ. An enzyme electrode for amperometric determination of glucose and lactate. Anal Chim Acta 1973; 64: 439-45.
    • (1973) Anal Chim Acta , vol.64 , pp. 439-445
    • Guilbault, G.G.1    Lubrano, G.J.2
  • 91
    • 0001439156 scopus 로고
    • Biocatalytic oxidation of glucose on the conductive charge transfer complex
    • Cenas NK, Kulys JJ. Biocatalytic oxidation of glucose on the conductive charge transfer complex. Bioelectrochem Bioenerget 1981; 8: 103-13.
    • (1981) Bioelectrochem Bioenerget , vol.8 , pp. 103-113
    • Cenas, N.K.1    Kulys, J.J.2
  • 92
  • 93
    • 0020037171 scopus 로고
    • Progress towards a potentially implantable enzyme-based glucose sensor
    • Gough DA, Leypoldt J, Armor JC. Progress towards a potentially implantable enzyme-based glucose sensor. Diabetes Care 1982; 5: 190-8.
    • (1982) Diabetes Care , vol.5 , pp. 190-198
    • Gough, D.A.1    Leypoldt, J.2    Armor, J.C.3
  • 94
    • 0022720413 scopus 로고
    • Performance characteristics of a planar dark-type oxygen sensor
    • Koudelka M. Performance characteristics of a planar dark-type oxygen sensor. Sensors & Actuators 1986; 9: 249-58.
    • (1986) Sensors & Actuators , vol.9 , pp. 249-258
    • Koudelka, M.1
  • 95
    • 0027283749 scopus 로고
    • Thin-film clark-type oxygen sensor based on novel polymer membrane system for in vivo and biosensor applications
    • Jobst G, Urban G, Jachimowlitz A, Kohl F, Tilado O. Thin-film clark-type oxygen sensor based on novel polymer membrane system for in vivo and biosensor applications. Biosensors of Bioelectronics 1993; 8: 123-8.
    • (1993) Biosensors of Bioelectronics , vol.8 , pp. 123-128
    • Jobst, G.1    Urban, G.2    Jachimowlitz, A.3    Kohl, F.4    Tilado, O.5
  • 96
    • 0028333212 scopus 로고
    • Towards an implantable refillable glucose sensor based on oxygen electrode principles
    • Xie SL, Wilkins E, Atanasov P. Towards an implantable refillable glucose sensor based on oxygen electrode principles. Sensors & Actuators B, 1993; 17: 133-42.
    • (1993) Sensors & Actuators B , vol.17 , pp. 133-142
    • Xie, S.L.1    Wilkins, E.2    Atanasov, P.3
  • 97
    • 84973003408 scopus 로고
    • Glucose biosensor based on oxygen electrode. Part I: Silastic coated polycarbonate membranes for biosensor application
    • Atanasov P, Wilkins E. Glucose biosensor based on oxygen electrode. Part I: silastic coated polycarbonate membranes for biosensor application. Analytical letters 1993; 28: 1587-612.
    • (1993) Analytical Letters , vol.28 , pp. 1587-1612
    • Atanasov, P.1    Wilkins, E.2
  • 98
    • 0043230063 scopus 로고
    • Glucose biosensor based on oxygen electrode. Part II: Long term operational stability of the rechargeable glucose biosensor
    • Atanasov P, Wilkins E. Glucose biosensor based on oxygen electrode. Part II: long term operational stability of the rechargeable glucose biosensor. Analytical Letters 1993; 26: 2079-94.
    • (1993) Analytical Letters , vol.26 , pp. 2079-2094
    • Atanasov, P.1    Wilkins, E.2
  • 99
    • 0028764817 scopus 로고
    • Development of biosensor for glucose monitoring
    • Atanasov P, Wilkins E. Development of biosensor for glucose monitoring. Biotechnol Bioeng 1994; 43: 262-6.
    • (1994) Biotechnol Bioeng , vol.43 , pp. 262-266
    • Atanasov, P.1    Wilkins, E.2
  • 102
    • 0021646139 scopus 로고
    • Model of a two-substrate enzyme electrode for glucose
    • Leypoldt J, Gough DA. Model of a two-substrate enzyme electrode for glucose. Anal Chem 1984; 56: 2896-904.
    • (1984) Anal Chem , vol.56 , pp. 2896-2904
    • Leypoldt, J.1    Gough, D.A.2
  • 103
    • 0022138056 scopus 로고
    • A two-dimensional enzyme electrode for glucose
    • Gough DA, Lucisano JY, Tse PHS. A two-dimensional enzyme electrode for glucose. Anal Chem 1985; 57: 2351-7.
    • (1985) Anal Chem , vol.57 , pp. 2351-2357
    • Gough, D.A.1    Lucisano, J.Y.2    Tse, P.H.S.3
  • 104
    • 0023324608 scopus 로고
    • Determination of the intrinsic kinetic constants of immobilized glucose oxidase and catalase
    • Tse PHS, Leypoldt J, Gough DA. Determination of the intrinsic kinetic constants of immobilized glucose oxidase and catalase. Biotechnol Bioeng 1987; 29: 696-704.
    • (1987) Biotechnol Bioeng , vol.29 , pp. 696-704
    • Tse, P.H.S.1    Leypoldt, J.2    Gough, D.A.3
  • 105
    • 0023324607 scopus 로고
    • Time dependent inactivation of immobilized glucose oxidase and catalase
    • Tse PHS, Gough DA. Time dependent inactivation of immobilized glucose oxidase and catalase. Biotechnol Bioeng 1987; 29: 705-13.
    • (1987) Biotechnol Bioeng , vol.29 , pp. 705-713
    • Tse, P.H.S.1    Gough, D.A.2
  • 106
    • 0024044231 scopus 로고
    • Transient response of the two-dimensional glucose sensor
    • Lucisano JY, Gough DA. Transient response of the two-dimensional glucose sensor. Anal Chem 1988; 60: 1272-81.
    • (1988) Anal Chem , vol.60 , pp. 1272-1281
    • Lucisano, J.Y.1    Gough, D.A.2
  • 109
    • 0024211587 scopus 로고
    • The glucose enzyme electrode: Is simple peroxide detection at a needle sensor acceptable
    • Vadgama P, Mullen W, Churchouse S, Battersby C. The glucose enzyme electrode: is simple peroxide detection at a needle sensor acceptable. Horm Met Res Suppl Ser 1988; 20: 20-2.
    • (1988) Horm Met Res Suppl Ser , vol.20 , pp. 20-22
    • Vadgama, P.1    Mullen, W.2    Churchouse, S.3    Battersby, C.4
  • 112
    • 0026590041 scopus 로고
    • Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor
    • Moatti-Sirat D, Velho G, Reach G. Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosensors & Bioelectronics 1992; 7: 345-52.
    • (1992) Biosensors & Bioelectronics , vol.7 , pp. 345-352
    • Moatti-Sirat, D.1    Velho, G.2    Reach, G.3
  • 113
    • 0024682563 scopus 로고
    • Fabrication and characterization of a planar electrochemical cell and its application as a glucose sensor
    • Gernet S, Koudelka M, De Rooij NF. Fabrication and characterization of a planar electrochemical cell and its application as a glucose sensor. Sensors & Actuators 1989; 18: 59-70.
    • (1989) Sensors & Actuators , vol.18 , pp. 59-70
    • Gernet, S.1    Koudelka, M.2    De Rooij, N.F.3
  • 114
    • 0024683002 scopus 로고
    • Planar amperometric enzyme-based glucose microelectrode
    • Koudelka M, Gernet S, De Rooij NF. Planar amperometric enzyme-based glucose microelectrode. Sensors & Actuators 1989; 18: 157-65.
    • (1989) Sensors & Actuators , vol.18 , pp. 157-165
    • Koudelka, M.1    Gernet, S.2    De Rooij, N.F.3
  • 115
    • 0024214711 scopus 로고
    • An amperometric glucose sensor with combined enzyme layers
    • Weiss T, Cammann K. An amperometric glucose sensor with combined enzyme layers. Horm Metab Res Supl Ser 1988; 20: 23-5.
    • (1988) Horm Metab Res Supl Ser , vol.20 , pp. 23-25
    • Weiss, T.1    Cammann, K.2
  • 117
    • 0020297949 scopus 로고
    • A membrane combination for implantable glucose sensors. Measurements in undiluted biological fluids
    • Fisher U, Abel P. A membrane combination for implantable glucose sensors. Measurements in undiluted biological fluids. Trans Am Soc Artif Internal Organs 1982; 27: 245-8.
    • (1982) Trans Am Soc Artif Internal Organs , vol.27 , pp. 245-248
    • Fisher, U.1    Abel, P.2
  • 118
    • 0028533426 scopus 로고
    • In vitro and in vivo performance and lifetime of perfluorinated ionomer coated glucose sensors after high-temperature curing
    • Moussy F, Jakeway S, Harrison DJ, Rajotte RV. In vitro and in vivo performance and lifetime of perfluorinated ionomer coated glucose sensors after high-temperature curing. Anal Chem 1994; 66: 3882-8.
    • (1994) Anal Chem , vol.66 , pp. 3882-3888
    • Moussy, F.1    Jakeway, S.2    Harrison, D.J.3    Rajotte, R.V.4
  • 119
    • 0024095481 scopus 로고
    • Characterization of perfluorsulfonic acid polymer coated enzyme electrode and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • Harrison DJ, Turner RFB, Baltes HP. Characterization of perfluorsulfonic acid polymer coated enzyme electrode and a miniaturized integrated potentiostat for glucose analysis in whole blood. Anal Chem 1988; 60: 2002-7.
    • (1988) Anal Chem , vol.60 , pp. 2002-2007
    • Harrison, D.J.1    Turner, R.F.B.2    Baltes, H.P.3
  • 121
    • 0027650815 scopus 로고
    • Performance of subcutaneously implanted needle-type glucose sensor employing a novel trilayer coating
    • Moussy F, Harrison DJ, O'Brien DW, Rajotte RV. Performance of subcutaneously implanted needle-type glucose sensor employing a novel trilayer coating. Anal Chem 1993; 65: 2072-7.
    • (1993) Anal Chem , vol.65 , pp. 2072-2077
    • Moussy, F.1    Harrison, D.J.2    O'Brien, D.W.3    Rajotte, R.V.4
  • 123
    • 0027068213 scopus 로고
    • Miniaturized multi-enzyme biosensors integrated with pH-sensors on flexible polymer carriers for in vivo applications
    • Urban G, Jobst G, Keplinger F, Aschayer E, Jachimowlitz A, Kohl F. Miniaturized multi-enzyme biosensors integrated with pH-sensors on flexible polymer carriers for in vivo applications. Biosensors & Bioelectronics 1992; 7: 733-9.
    • (1992) Biosensors & Bioelectronics , vol.7 , pp. 733-739
    • Urban, G.1    Jobst, G.2    Keplinger, F.3    Aschayer, E.4    Jachimowlitz, A.5    Kohl, F.6
  • 124
    • 0023688219 scopus 로고
    • Enzyme electrode for determining of glucose in whole blood
    • Genshow MA. Enzyme electrode for determining of glucose in whole blood. Clin Chem 1988; 34: 1717-9.
    • (1988) Clin Chem , vol.34 , pp. 1717-1719
    • Genshow, M.A.1
  • 127
    • 0022757755 scopus 로고
    • Potentially-implantable, ferrocene mediated glucose sensor
    • Claremont DJ, Penton C, Pickup JC. Potentially-implantable, ferrocene mediated glucose sensor. J. Biomed Eng 1986; 8: 272-4.
    • (1986) J. Biomed Eng , vol.8 , pp. 272-274
    • Claremont, D.J.1    Penton, C.2    Pickup, J.C.3
  • 128
    • 0022913659 scopus 로고
    • Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs
    • Claremont DJ, Sambrook IE, Penton C, Pickup JC. Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs. Diabetologia 1986; 29: 817-21.
    • (1986) Diabetologia , vol.29 , pp. 817-821
    • Claremont, D.J.1    Sambrook, I.E.2    Penton, C.3    Pickup, J.C.4
  • 129
    • 0024271835 scopus 로고
    • Progress towards in vivo glucose sensing with a ferrocene-mediated amperometric enzyme electrode
    • Pickup JC, Claremont DJ. Progress towards in vivo glucose sensing with a ferrocene-mediated amperometric enzyme electrode. Horm Metab Res Supl Ser 1988; 20: 34-6.
    • (1988) Horm Metab Res Supl Ser , vol.20 , pp. 34-36
    • Pickup, J.C.1    Claremont, D.J.2
  • 131
    • 0024602510 scopus 로고
    • Potentially implantable amperometric glucose sensors with mediated electron transfer: Improving the operating stability
    • Pickup JC, Show GW, Claremont JD. Potentially implantable amperometric glucose sensors with mediated electron transfer: improving the operating stability. Biosensors 1989; 4: 109-19.
    • (1989) Biosensors , vol.4 , pp. 109-119
    • Pickup, J.C.1    Show, G.W.2    Claremont, J.D.3
  • 132
    • 0024541965 scopus 로고
    • In vivo molecular sensing in diabetes mellitus: An implantable glucose sensor with direct electron transfer
    • Pickup JC, Show GW, Claremont JD. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 1989; 32: 213-7.
    • (1989) Diabetologia , vol.32 , pp. 213-217
    • Pickup, J.C.1    Show, G.W.2    Claremont, J.D.3
  • 134
    • 0026298988 scopus 로고
    • Artificial endocrine pancreas - Problems awaiting solution for long-term clinical applications of a glucose sensor
    • Shihiri M, Fukushima H, Sakakida M, Hashiguchi Y. Artificial endocrine pancreas - problems awaiting solution for long-term clinical applications of a glucose sensor. Frontiers Med Biol Eng 1991; 3: 283-92.
    • (1991) Frontiers Med Biol Eng , vol.3 , pp. 283-292
    • Shihiri, M.1    Fukushima, H.2    Sakakida, M.3    Hashiguchi, Y.4
  • 137
    • 0001072983 scopus 로고
    • Amperometric enzyme electrodes. Part 2: Conducting organic salt as electrode materials for the oxidation of glucose oxidase
    • Albery WJ, Bartlett PN, Cracton D. Amperometric enzyme electrodes. Part 2: conducting organic salt as electrode materials for the oxidation of glucose oxidase. J Electroanal Chem 1985; 194: 223-35.
    • (1985) J Electroanal Chem , vol.194 , pp. 223-235
    • Albery, W.J.1    Bartlett, P.N.2    Cracton, D.3
  • 138
    • 85030200828 scopus 로고
    • An amperometric enzyme electrode for measuring changes in brain glucose
    • Albery WJ, Bartlett PN, Boutelle MG, Fillenz M. An amperometric enzyme electrode for measuring changes in brain glucose. J Physiol 1986; 382: 93P-97P.
    • (1986) J Physiol , vol.382
    • Albery, W.J.1    Bartlett, P.N.2    Boutelle, M.G.3    Fillenz, M.4
  • 139
    • 0022970449 scopus 로고
    • An amperometric enzyme electrode for continuous monitoring of brain glucose in freely moving rat
    • Boutelle MG, Stanford C, Fillenz M, Albery WJ, Bartlett PN. An amperometric enzyme electrode for continuous monitoring of brain glucose in freely moving rat. Neurosci Lett 1987; 72: 283-8.
    • (1987) Neurosci Lett , vol.72 , pp. 283-288
    • Boutelle, M.G.1    Stanford, C.2    Fillenz, M.3    Albery, W.J.4    Bartlett, P.N.5
  • 141
    • 0023346438 scopus 로고
    • Long term in vitro operation of enzyme electrode based glucose sensor
    • Conway PJ, Gough DA. Long term in vitro operation of enzyme electrode based glucose sensor. Sensors & Actuators 1987; 1: 305-8.
    • (1987) Sensors & Actuators , vol.1 , pp. 305-308
    • Conway, P.J.1    Gough, D.A.2
  • 143
    • 0026220296 scopus 로고
    • Rechargeable glucose electrodes for long-term implantation
    • Xie SL, Wilkins E. Rechargeable glucose electrodes for long-term implantation. J Biomed Eng 1991; 13: 375-8.
    • (1991) J Biomed Eng , vol.13 , pp. 375-378
    • Xie, S.L.1    Wilkins, E.2
  • 144
    • 0026230286 scopus 로고
    • Performances of potentially implantable rechargeable glucose sensor in vitro at body temperature
    • Xie SL, Wilkins E. Performances of potentially implantable rechargeable glucose sensor in vitro at body temperature. Biomed Instrum & Technol 1991; 25: 393-9.
    • (1991) Biomed Instrum & Technol , vol.25 , pp. 393-399
    • Xie, S.L.1    Wilkins, E.2
  • 145
    • 0024950185 scopus 로고
    • The needle glucose electrode: In vitro performance and optimization for implantation
    • Vadgama P, Spoors J, Tang LX, Battersby C. The needle glucose electrode: in vitro performance and optimization for implantation. Biomed Biochim Acta 1989; 48: 935-42.
    • (1989) Biomed Biochim Acta , vol.48 , pp. 935-942
    • Vadgama, P.1    Spoors, J.2    Tang, L.X.3    Battersby, C.4
  • 146
    • 0039302020 scopus 로고
    • Needle-type glucose sensor and its clinical applications
    • Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford
    • Shichiri M, Kawamori R, Yamasaki Y. Needle-type glucose sensor and its clinical applications. In Biosensors: Fundamentals and Applications. Eds Turner APF, Karube I, Wilson GS. Oxford University Press, Oxford, 1987; 409-25.
    • (1987) Biosensors: Fundamentals and Applications , pp. 409-425
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3
  • 147
    • 0024270045 scopus 로고
    • In vivo characteristics of needle-type glucose sensor -measurement of subcutaneous glucose concentration in human volunteers
    • Shichiri M, Yamasaki Y, Nao K, Sekiya M, Ueda N. In vivo characteristics of needle-type glucose sensor -measurement of subcutaneous glucose concentration in human volunteers. Horm Metab Res Supl Ser 1988; 20: 17-20.
    • (1988) Horm Metab Res Supl Ser , vol.20 , pp. 17-20
    • Shichiri, M.1    Yamasaki, Y.2    Nao, K.3    Sekiya, M.4    Ueda, N.5
  • 149
    • 0343424558 scopus 로고
    • Needle-type glucose sensor based titanium oxide type on oxygen electrode
    • Ikeda S, Ito K, Ohkura K, Takagi H, Kondo T. Needle-type glucose sensor based titanium oxide type on oxygen electrode. Artif Organs 1990; 14: 24-7.
    • (1990) Artif Organs , vol.14 , pp. 24-27
    • Ikeda, S.1    Ito, K.2    Ohkura, K.3    Takagi, H.4    Kondo, T.5
  • 150
    • 0343860321 scopus 로고
    • Artificial pancreas: Development of a new needle-type glucose sensor based on oxygen electrode with a new concept
    • Ikeda S, Ito K, Ohkura K, Nakao A, Takagi H, Kondo T. Artificial pancreas: development of a new needle-type glucose sensor based on oxygen electrode with a new concept. Artif Organs Today 1991; 1: 303-13.
    • (1991) Artif Organs Today , vol.1 , pp. 303-313
    • Ikeda, S.1    Ito, K.2    Ohkura, K.3    Nakao, A.4    Takagi, H.5    Kondo, T.6
  • 152
    • 0026628622 scopus 로고
    • Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials
    • Chen CY, Gotoh M, Makino H, Su YC, Tamia E, Karube I. Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials. Anal Chim Acta 1992; 265: 5-14.
    • (1992) Anal Chim Acta , vol.265 , pp. 5-14
    • Chen, C.Y.1    Gotoh, M.2    Makino, H.3    Su, Y.C.4    Tamia, E.5    Karube, I.6
  • 154
    • 0342989011 scopus 로고
    • Biocompatible membranes with special functions for biosensors applications
    • Chen CY, Karube I. Biocompatible membranes with special functions for biosensors applications. Membrane 1993; 18: 207-19.
    • (1993) Membrane , vol.18 , pp. 207-219
    • Chen, C.Y.1    Karube, I.2
  • 155
    • 0024576715 scopus 로고
    • Working potential stability of a needle-type subcutaneous glucose sensor: Influence of needle material upon in vitro and in vivo sensor performances
    • Velho G, Froguel Ph, Sternberg R, Thevenot DR, Reach G. Working potential stability of a needle-type subcutaneous glucose sensor: influence of needle material upon in vitro and in vivo sensor performances. Diabetes 1989; 38: 164-71.
    • (1989) Diabetes , vol.38 , pp. 164-171
    • Velho, G.1    Froguel, Ph.2    Sternberg, R.3    Thevenot, D.R.4    Reach, G.5
  • 157
    • 0027952276 scopus 로고
    • Development of a needle-type glucose biosensor
    • Abdel-Hamid I, Atanasov P, Wilkins E. Development of a needle-type glucose biosensor. Anal Letters 1994; 27: 1453-73.
    • (1994) Anal Letters , vol.27 , pp. 1453-1473
    • Abdel-Hamid, I.1    Atanasov, P.2    Wilkins, E.3
  • 158
    • 0028218970 scopus 로고
    • Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method
    • Hashiguchi Y, Sakaida M, Nishida K, Uemura T, Kajiwara K, Shihiri M. Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Diabetes Care 1994; 5: 387-96.
    • (1994) Diabetes Care , vol.5 , pp. 387-396
    • Hashiguchi, Y.1    Sakaida, M.2    Nishida, K.3    Uemura, T.4    Kajiwara, K.5    Shihiri, M.6
  • 159
    • 0025870762 scopus 로고
    • In vitro testing of a simply constructed highly stable glucose sensor suitable for implantation in diabetic patient
    • Show GW, Claremont JD, Pickup JC. In vitro testing of a simply constructed highly stable glucose sensor suitable for implantation in diabetic patient. Biosensors & Bioelectronics 1991; 6: 401-6.
    • (1991) Biosensors & Bioelectronics , vol.6 , pp. 401-406
    • Show, G.W.1    Claremont, J.D.2    Pickup, J.C.3
  • 161
    • 0024514006 scopus 로고
    • In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method
    • Bruckel J, Kerner W, Zeir H, Steibach G, Pfeiffer EF. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method. Klin Wochenschr 1989; 67: 491-5.
    • (1989) Klin Wochenschr , vol.67 , pp. 491-495
    • Bruckel, J.1    Kerner, W.2    Zeir, H.3    Steibach, G.4    Pfeiffer, E.F.5
  • 162
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • Moatti-Sirat D, Copron F, Poitout V, Reach G, Bindra DS, Zhang Y, Wilson GS, Thevenot DR. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 1992; 35: 224-30.
    • (1992) Diabetologia , vol.35 , pp. 224-230
    • Moatti-Sirat, D.1    Copron, F.2    Poitout, V.3    Reach, G.4    Bindra, D.S.5    Zhang, Y.6    Wilson, G.S.7    Thevenot, D.R.8
  • 163
    • 0027214964 scopus 로고
    • A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit
    • Poitout V, Moatti-Sirat D, Reach G, Zhang Y, Wilson GS, Lemonnier F, Klein JC. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia 1993; 36: 658-63.
    • (1993) Diabetologia , vol.36 , pp. 658-663
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3    Zhang, Y.4    Wilson, G.S.5    Lemonnier, F.6    Klein, J.C.7
  • 164
    • 0027236355 scopus 로고
    • In vivo and in vitro evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor
    • Zhang Y, Wilson GS. In vivo and in vitro evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor. Anal Chim Acta 1993; 281: 513-20.
    • (1993) Anal Chim Acta , vol.281 , pp. 513-520
    • Zhang, Y.1    Wilson, G.S.2
  • 165
    • 0027199596 scopus 로고
    • A needle-type enzyme-based lactate sensor for in vivo monitoring
    • Hu Y, Zhang Y, Wilson GS. A needle-type enzyme-based lactate sensor for in vivo monitoring. Anal Chim Acta 1993; 281: 503-11.
    • (1993) Anal Chim Acta , vol.281 , pp. 503-511
    • Hu, Y.1    Zhang, Y.2    Wilson, G.S.3
  • 167
    • 0022481785 scopus 로고
    • Continuously monitored subcutaneous glucose concentration by using implanted enzyme electrodes
    • German
    • Muller A, Abel P, Fisher U. Continuously monitored subcutaneous glucose concentration by using implanted enzyme electrodes (German). Biomed Biochim Acta 1986; 45: 769-77.
    • (1986) Biomed Biochim Acta , vol.45 , pp. 769-777
    • Muller, A.1    Abel, P.2    Fisher, U.3
  • 168
    • 0024271834 scopus 로고
    • Issues related to in vitro operation of potentially implantable enzyme electrode glucose sensors
    • Gough DA. Issues related to in vitro operation of potentially implantable enzyme electrode glucose sensors. Horm Metab Res Supl Ser 1988; 20: 30-3.
    • (1988) Horm Metab Res Supl Ser , vol.20 , pp. 30-33
    • Gough, D.A.1
  • 169
    • 0024041578 scopus 로고
    • A telemetry instrumentation system for chronically implanted glucose and oxygen sensors
    • McKean BD, Gough DA. A telemetry instrumentation system for chronically implanted glucose and oxygen sensors. IEEE Trans Biomed Eng 1988; 35: 526-32.
    • (1988) IEEE Trans Biomed Eng , vol.35 , pp. 526-532
    • McKean, B.D.1    Gough, D.A.2
  • 170
    • 0024731165 scopus 로고
    • Physiologic preparation for studying the response of subcutaneously implanted glucose and oxygen sensors
    • Ertefai S, Gough DA. Physiologic preparation for studying the response of subcutaneously implanted glucose and oxygen sensors. J Biomed Eng 1989; 11: 362-8.
    • (1989) J Biomed Eng , vol.11 , pp. 362-368
    • Ertefai, S.1    Gough, D.A.2
  • 171
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • Armor JC, Lucisano JY, McKean BD, Gough DA. Application of chronic intravascular blood glucose sensor in dogs. Diabetes 1990; 39: 1519-26.
    • (1990) Diabetes , vol.39 , pp. 1519-1526
    • Armor, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 174
    • 0027591452 scopus 로고
    • Electrodeposition of glucose oxidase for the fabrication of miniature sensors
    • Strike DJ, De Rooij NF, Koudelka-Hep M. Electrodeposition of glucose oxidase for the fabrication of miniature sensors. Sensors & Actuators B 1993; 13-14: 61-4.
    • (1993) Sensors & Actuators B , vol.13-14 , pp. 61-64
    • Strike, D.J.1    De Rooij, N.F.2    Koudelka-Hep, M.3
  • 176
  • 179
    • 0023580011 scopus 로고
    • Assessment of subcutaneous glucose concentration: Validation of the wick technique as a reference for implanted electrochemical sensor in normal and diabetic dogs
    • Fischer U, Ertle R, Abel P, Rebrin K, Brunstein E, von Dorsche HH, Freyse EJ. Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensor in normal and diabetic dogs. Diabetologia 1987; 30: 940-5.
    • (1987) Diabetologia , vol.30 , pp. 940-945
    • Fischer, U.1    Ertle, R.2    Abel, P.3    Rebrin, K.4    Brunstein, E.5    Von Dorsche, H.H.6    Freyse, E.J.7
  • 181
    • 0024954424 scopus 로고
    • Preparation and validation of implantable electrodes for measurement of oxygen and glucose
    • Brunstein E, Abel P, Gens A, Eich K, von Woedtke Th. Preparation and validation of implantable electrodes for measurement of oxygen and glucose. Biomed Biochim Acta 1989; 48: 911-7.
    • (1989) Biomed Biochim Acta , vol.48 , pp. 911-917
    • Brunstein, E.1    Abel, P.2    Gens, A.3    Eich, K.4    Von Woedtke, Th.5
  • 184
    • 0024342096 scopus 로고
    • Automated feed-back control of subcutaneous glucose concentration in diabetic dogs
    • Rebrin K, Fischer U, Woedtke TV, Abel P, Brunstein E. Automated feed-back control of subcutaneous glucose concentration in diabetic dogs. Diabetologia 1989; 32: 573-6.
    • (1989) Diabetologia , vol.32 , pp. 573-576
    • Rebrin, K.1    Fischer, U.2    Woedtke, T.V.3    Abel, P.4    Brunstein, E.5
  • 185
    • 0027624475 scopus 로고
    • A rechargeable glucose sensor - Long term activity and performance
    • Wilkins E. A rechargeable glucose sensor - long term activity and performance. Biomed Instrum & Technol 1993; 27: 325-33.
    • (1993) Biomed Instrum & Technol , vol.27 , pp. 325-333
    • Wilkins, E.1
  • 187
    • 0027230940 scopus 로고
    • Glucose concentration in subcutaneous extracellular space
    • Schmidt FJ, Slutter WJ, Schoonen AJM. Glucose concentration in subcutaneous extracellular space. Diabetes Care 1993; 16: 695-700.
    • (1993) Diabetes Care , vol.16 , pp. 695-700
    • Schmidt, F.J.1    Slutter, W.J.2    Schoonen, A.J.M.3
  • 188
    • 0024243378 scopus 로고
    • In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics
    • Velho G, Froguel Ph, Thevenot DR, Reach G. In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics. Diab Nutr Metab 1988; 1: 227-34.
    • (1988) Diab Nutr Metab , vol.1 , pp. 227-234
    • Velho, G.1    Froguel, Ph.2    Thevenot, D.R.3    Reach, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.