메뉴 건너뛰기




Volumn 19, Issue 6, 2011, Pages 899-903

Three- to six-year follow-up results after high-flexion total knee arthroplasty: Can we allow passive deep knee bending?

Author keywords

Early loosening; Kneeling; Nexgen LPS flex; Squatting; Total knee arthroplasty

Indexed keywords

AGED; ARTICLE; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; CONVALESCENCE; EVALUATION; EXERCISE; FEMALE; FOLLOW UP; HUMAN; JOINT CHARACTERISTICS AND FUNCTIONS; JOINT INSTABILITY; KNEE; KNEE ARTHROPLASTY; KNEE OSTEOARTHRITIS; KNEE PROSTHESIS; MALE; METHODOLOGY; MIDDLE AGED; PAIN ASSESSMENT; PATHOPHYSIOLOGY; PATIENT SATISFACTION; PHYSICAL EXAMINATION; PHYSIOLOGY; POSTOPERATIVE CARE; RADIOGRAPHY; RETROSPECTIVE STUDY; STATISTICS; TIME; TREATMENT OUTCOME; WEIGHT BEARING;

EID: 79956117133     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-010-1218-x     Document Type: Article
Times cited : (53)

References (21)
  • 3
    • 34047222100 scopus 로고    scopus 로고
    • Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery
    • Bin SI, Nam TS (2007) Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc 15: 350-355.
    • (2007) Knee Surg Sports Traumatol Arthrosc , vol.15 , pp. 350-355
    • Bin, S.I.1    Nam, T.S.2
  • 5
    • 0031661292 scopus 로고    scopus 로고
    • Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions
    • Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN (1998) Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13: 748-752.
    • (1998) J Arthroplasty , vol.13 , pp. 748-752
    • Dennis, D.A.1    Komistek, R.D.2    Stiehl, J.B.3    Walker, S.A.4    Dennis, K.N.5
  • 6
    • 56749098225 scopus 로고    scopus 로고
    • In vivo contact stresses during activities of daily living after knee arthroplasty
    • D'Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell CW Jr (2008) In vivo contact stresses during activities of daily living after knee arthroplasty. J Orthop Res 26: 1549-1555.
    • (2008) J Orthop Res , vol.26 , pp. 1549-1555
    • D'Lima, D.D.1    Steklov, N.2    Fregly, B.J.3    Banks, S.A.4    Colwell Jr., C.W.5
  • 7
    • 37249046365 scopus 로고    scopus 로고
    • High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement
    • Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89: 1457-1461.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 1457-1461
    • Han, H.S.1    Kang, S.B.2    Yoon, K.S.3
  • 8
    • 23044441339 scopus 로고    scopus 로고
    • The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up
    • Huang HT, Su JY, Wang GJ (2005) The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20: 674-679.
    • (2005) J Arthroplasty , vol.20 , pp. 674-679
    • Huang, H.T.1    Su, J.Y.2    Wang, G.J.3
  • 9
    • 0018346367 scopus 로고
    • The total condylar knee prosthesis. A report of two hundred and twenty cases
    • Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis. A report of two hundred and twenty cases. J Bone Joint Surg Am 61: 173-180.
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 173-180
    • Insall, J.1    Scott, W.N.2    Ranawat, C.S.3
  • 10
    • 53849148920 scopus 로고    scopus 로고
    • The NexGen LPS-flex to the knee prosthesis at a minimum of three years
    • Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 90: 1304-1310.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1304-1310
    • Kim, T.H.1    Lee, D.H.2    Bin, S.I.3
  • 11
    • 77950518717 scopus 로고    scopus 로고
    • Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients
    • Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25: 458-464.
    • (2010) J Arthroplasty , vol.25 , pp. 458-464
    • Kim, T.K.1    Kwon, S.K.2    Kang, Y.G.3    Chang, C.B.4    Seong, S.C.5
  • 12
    • 21444455369 scopus 로고    scopus 로고
    • Range of motion of standard and high-flexion posterior stabilized total knee prosthesis. A prospective, randomized study
    • Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prosthesis. A prospective, randomized study. J Bone Joint Surg Am 87: 1470-1475.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1470-1475
    • Kim, Y.H.1    Sohn, K.S.2    Kim, J.S.3
  • 13
    • 0021912380 scopus 로고
    • Femoral component loosening in total knee arthroplasty
    • King TV, Scott RD (1985) Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res 194: 285-290.
    • (1985) Clin Orthop Relat Res , vol.194 , pp. 285-290
    • King, T.V.1    Scott, R.D.2
  • 14
    • 0036086496 scopus 로고    scopus 로고
    • Maximizing flexion after total knee arthroplasty: the need and the pitfalls
    • Kurosaka M, Yoshiya S, Mizuno K, Yamamoto T (2002) Maximizing flexion after total knee arthroplasty: the need and the pitfalls. J Arthroplasty 17: 59-62.
    • (2002) J Arthroplasty , vol.17 , pp. 59-62
    • Kurosaka, M.1    Yoshiya, S.2    Mizuno, K.3    Yamamoto, T.4
  • 15
    • 52049086064 scopus 로고    scopus 로고
    • High-flexion total knee arthroplasty
    • Long WJ, Scuderi GR (2008) High-flexion total knee arthroplasty. J Arthroplasty 23: 6-10.
    • (2008) J Arthroplasty , vol.23 , pp. 6-10
    • Long, W.J.1    Scuderi, G.R.2
  • 16
    • 0034868709 scopus 로고    scopus 로고
    • Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants
    • Mulholland SJ, Wyss UP (2001) Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24: 191-198.
    • (2001) Int J Rehabil Res , vol.24 , pp. 191-198
    • Mulholland, S.J.1    Wyss, U.P.2
  • 18
  • 19
    • 34548359378 scopus 로고    scopus 로고
    • Functional disabilities and issues of concern in female Asian patients before TKA
    • Park KK, Shin KS, Chang CB, Kim SJ, Kim TK (2007) Functional disabilities and issues of concern in female Asian patients before TKA. Clin Orthop Relat Res 461: 143-152.
    • (2007) Clin Orthop Relat Res , vol.461 , pp. 143-152
    • Park, K.K.1    Shin, K.S.2    Chang, C.B.3    Kim, S.J.4    Kim, T.K.5
  • 20
    • 0023186828 scopus 로고
    • Effect of range of motion on the success of a total knee arthroplasty
    • Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 2: 95-97.
    • (1987) J Arthroplasty , vol.2 , pp. 95-97
    • Ritter, M.A.1    Campbell, E.D.2
  • 21
    • 16844368269 scopus 로고    scopus 로고
    • Contact stresses in the knee joint in deep flexion
    • Thambyah A, Goh JC, De SD (2005) Contact stresses in the knee joint in deep flexion. Med Eng Phys 27: 329-335.
    • (2005) Med Eng Phys , vol.27 , pp. 329-335
    • Thambyah, A.1    Goh, J.C.2    De, S.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.