-
1
-
-
0025273748
-
Acute myocardial dysfunction and recovery: A common occurrence after coronary bypass surgery
-
Breisblatt W., Stein K., Wolfe C., Follansbee W., Capozzi J., Armitage J., Hadersty R., Acute myocardial dysfunction and recovery : a common occurrence after coronary bypass surgery, J. AM. COLL. CARDIOL, 15, 1261-1269, 1990. (Pubitemid 20141101)
-
(1990)
Journal of the American College of Cardiology
, vol.15
, Issue.6
, pp. 1261-1269
-
-
Breisblatt, W.M.1
Stein, K.L.2
Wolfe, C.J.3
Follansbee, W.P.4
Capozzi, J.5
Armitage, J.M.6
Hardesty, R.L.7
-
2
-
-
12144287425
-
Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
-
DOI 10.1097/01.CCM.0000114996.68110.C9
-
Kumar A., Anel R., Bunnell E., Habet K., Zanotti S., Marshall S., Neumann A., Ali A., Cheang M., Kavinsky C., Parrillo J. E., Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects, CRIT. CARE MED., 32, 691-699, 2004. (Pubitemid 38340065)
-
(2004)
Critical Care Medicine
, vol.32
, Issue.3
, pp. 691-699
-
-
Kumar, A.1
Anel, R.2
Bunnell, E.3
Habet, K.4
Zanotti, S.5
Marshall, S.6
Neumann, A.7
Ali, A.8
Cheang, M.9
Kavinsky, C.10
Parrillo, J.E.11
-
3
-
-
0028100054
-
Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function
-
Cheung A., Savino J., Weiss S., Aukburg S., Berlin J., Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function, ANESTHESIOLOGY, 81, 376-387, 1994. (Pubitemid 24320629)
-
(1994)
Anesthesiology
, vol.81
, Issue.2
, pp. 376-387
-
-
Cheung, A.T.1
Savino, J.S.2
Weiss, S.J.3
Aukburg, S.J.4
Berlin, J.A.5
-
4
-
-
0033001658
-
Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock
-
DOI 10.1016/S0883-9441(99)90018-7
-
Sakka S., Bredle D., Reinhart K., Meier-Hellmann A., Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock, J. CRIT. CARE, 14, 78-83, 1999. (Pubitemid 29278265)
-
(1999)
Journal of Critical Care
, vol.14
, Issue.2
, pp. 78-83
-
-
Sakka, S.G.1
Bredle, D.L.2
Reinhart, K.3
Meier-Hellmann, A.4
-
5
-
-
0023605206
-
The systolic pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
-
Perel A., Pizov R., Cotev S., The systolic pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. ANESTHESIOLOGY, 67, 489-502, 1987.
-
(1987)
Anesthesiology
, vol.67
, pp. 489-502
-
-
Perel, A.1
Pizov, R.2
Cotev, S.3
-
6
-
-
0032420373
-
Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients
-
DOI 10.1097/00000542-199812000-00005
-
Perel A., Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients, ANESTHESIOLOGY, 89, 1309-1310, 1998. (Pubitemid 29001566)
-
(1998)
Anesthesiology
, vol.89
, Issue.6
, pp. 1309-1310
-
-
Perel, A.1
-
7
-
-
0028906057
-
The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation
-
Rooke G., Schwid H., Shapira Y., The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation, ANESTH. ANALG., 80, 925-932, 1995.
-
(1995)
Anesth. Analg.
, vol.80
, pp. 925-932
-
-
Rooke, G.1
Schwid, H.2
Shapira, Y.3
-
8
-
-
0032437998
-
Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
-
DOI 10.1097/00000542-199812000-00007
-
Tavernier B., Makhotine O., Lebuffe G., Dupont J., Scherpereel P., Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension, ANESTHESIOLOGY, 89, 1313-1321, 1998. (Pubitemid 29001568)
-
(1998)
Anesthesiology
, vol.89
, Issue.6
, pp. 1313-1321
-
-
Tavernier, B.1
Makhotine, O.2
Lebuffe, G.3
Dupont, J.4
Scherpereel, P.5
-
9
-
-
0036283553
-
Predicting fluid responsiveness in ICU patients
-
Michard F., Teboul J., Predicting fluid responsiveness in ICU patients, CHEST, 121, 2000-2008, 2002.
-
(2002)
Chest
, vol.121
, pp. 2000-2008
-
-
Michard, F.1
Teboul, J.2
-
10
-
-
0036217518
-
Functional haemodynamic monitoring
-
Pinsky M., Functional haemodynamic monitoring, INTENSIVE CARE MED., 28, 386-388, 2002.
-
(2002)
Intensive Care Med.
, vol.28
, pp. 386-388
-
-
Pinsky, M.1
-
11
-
-
8744275421
-
Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery
-
DOI 10.1378/chest.126.5.1563
-
Kramer A., Zygun D., Hawes H., Easton P., Ferland A., Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. CHEST, 126, 1563-1568, 2004. (Pubitemid 39525032)
-
(2004)
Chest
, vol.126
, Issue.5
, pp. 1563-1568
-
-
Kramer, A.1
Zygun, D.2
Hawes, H.3
Easton, P.4
Ferland, A.5
-
12
-
-
0035080242
-
Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
-
Berkenstadt H., Margalit N., Hadani M., Friedman Z., Segal E., Villa Y., Perel A., Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery, ANESTH. ANALG., 92, 984-989, 2001. (Pubitemid 32239145)
-
(2001)
Anesthesia and Analgesia
, vol.92
, Issue.4
, pp. 984-989
-
-
Berkenstadt, H.1
Margalit, N.2
Hadani, M.3
Friedman, Z.4
Segal, E.5
Villa, Y.6
Perel, A.7
-
13
-
-
28844464011
-
Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators
-
DOI 10.1093/bja/aei262
-
Preisman S., Kogan S., Berkenstadt H., Perel A., Predicting fluid responsiveness in patients undergoing cardiac surgery : functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators, BR. J. ANAESTH., 95, 746-755, 2005. (Pubitemid 41762372)
-
(2005)
British Journal of Anaesthesia
, vol.95
, Issue.6
, pp. 746-755
-
-
Preisman, S.1
Kogan, S.2
Berkenstadt, H.3
Perel, A.4
-
14
-
-
23744504093
-
Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
-
DOI 10.1378/chest.128.2.848
-
Hofer C., Mueller S., Ferrer L., Klaghofer R., Genoni M., Zollinger A., Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting, CHEST, 128, 848-854, 2005. (Pubitemid 41140517)
-
(2005)
Chest
, vol.128
, Issue.2
, pp. 848-854
-
-
Hofer, C.K.1
Muller, S.M.2
Furrer, L.3
Klaghofer, R.4
Genoni, M.5
Zollinger, A.6
-
15
-
-
0033797681
-
Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation
-
Michard F., Teboul J., Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation, CRIT. CARE, 4, 282-289, 2000.
-
(2000)
Crit. Care
, vol.4
, pp. 282-289
-
-
Michard, F.1
Teboul, J.2
-
16
-
-
0002765004
-
A simple device for the continuous measurement of cardiac output
-
Wesseling K., de Wit B., Weber J., Smith N., A simple device for the continuous measurement of cardiac output, ADV. CARDIOVASC. PHYSIOL., 5, 16-52, 1983.
-
(1983)
Adv. Cardiovasc. Physiol.
, vol.5
, pp. 16-52
-
-
Wesseling, K.1
De Wit, B.2
Weber, J.3
Smith, N.4
-
17
-
-
0036219991
-
Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
-
DOI 10.1007/s00134-002-1211-z
-
Reuter D., Felbinger T., Schmidt C., Kilger E., Goedje O., Lamm P., Goetz A., Stroke volume variation for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery, INTENSIVE CARE MED., 28, 392-398, 2002. (Pubitemid 34328021)
-
(2002)
Intensive Care Medicine
, vol.28
, Issue.4
, pp. 392-398
-
-
Reuter, D.A.1
Felbinger, T.W.2
Schmidt, C.3
Kilger, E.4
Goedje, O.5
Lamm, P.6
Goetz, A.E.7
-
18
-
-
0036137453
-
Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations
-
DOI 10.1093/bja/88.1.124
-
Reuter D., Felbinger T., Kilger E., Schmidt C., Lamm P., Goetz A., Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations, BR. J. ANAESTH., 88, 124-126, 2002. (Pubitemid 34048570)
-
(2002)
British Journal of Anaesthesia
, vol.88
, Issue.1
, pp. 124-126
-
-
Reuter, D.A.1
Felbinger, T.W.2
Kilger, E.3
Schmidt, C.4
Lamm, P.5
Goetz, A.E.6
-
19
-
-
0037407062
-
Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
-
Wiesenack C., Prasser C., Roedig G., Keyl C. Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients, ANESTH. ANALG., 96, 1254-1257, 2003. (Pubitemid 36512859)
-
(2003)
Anesthesia and Analgesia
, vol.96
, Issue.5
, pp. 1254-1257
-
-
Wiesenack, C.1
Prasser, C.2
Rodig, G.3
Keyl, C.4
-
20
-
-
9744244186
-
Prediction of fluid responsiveness in patients during cardiac surgery
-
DOI 10.1093/bja/aeh280
-
Rex S., Brose S., Metzelder S., Hueneke R., Schaelte G., Autschbach R., Rossaint R., Buhre W., Prediction of fluid responsiveness in patients during cardiac surgery, BR. J. ANAESTH., 93, 782-788, 2004. (Pubitemid 39585607)
-
(2004)
British Journal of Anaesthesia
, vol.93
, Issue.6
, pp. 782-788
-
-
Rex, S.1
Brose, S.2
Metzelder, S.3
Huneke, R.4
Schalte, G.5
Autschbach, R.6
Rossaint, R.7
Buhre, W.8
-
21
-
-
24744434154
-
Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
-
DOI 10.1017/S0265021505001092
-
Wiesenack C., Fiegl C., Keyser A., Prasser C., Keyl C., Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients, EUR. J. ANAESTHESIOL., 22, 658-665, 2005. (Pubitemid 41297547)
-
(2005)
European Journal of Anaesthesiology
, vol.22
, Issue.9
, pp. 658-665
-
-
Wiesenack, C.1
Fiegl, C.2
Keyser, A.3
Prasser, C.4
Keyl, C.5
-
22
-
-
34547134966
-
An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
-
DOI 10.1111/j.1365-2044.2007.05135.x
-
De Wilde R., Schreuder J., van den Berg P., and Jansen J., An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery, ANAESTHESIA, 62, 760-768, 2007. (Pubitemid 47103623)
-
(2007)
Anaesthesia
, vol.62
, Issue.8
, pp. 760-768
-
-
De Wilde, R.B.P.1
Schreuder, J.J.2
Van Den, B.P.C.M.3
Jansen, J.R.C.4
-
23
-
-
59849086163
-
Review of the PiCCO device; our experience in the ICU
-
De Wilde J., van den Berg P., and Jansen J., Review of the PiCCO device; our experience in the ICU, NETH. J. CRIT. CARE, 12, 60-64, 2008.
-
(2008)
Neth. J. Crit. Care
, vol.12
, pp. 60-64
-
-
De Wilde, J.1
Van Den Berg, P.2
Jansen, J.3
-
24
-
-
0842284105
-
Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
-
DOI 10.1017/S0265021504002091
-
Marx G., Cope T., McCrossan L., Swaraj S., Cowan C., Mostafa S., Wenstone R., Leuwer M., Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis, EUR J ANAESTHESIOL, 21, 132-138, 2004. (Pubitemid 38176155)
-
(2004)
European Journal of Anaesthesiology
, vol.21
, Issue.2
, pp. 132-138
-
-
Marx, G.1
Cope, T.2
McCrossan, L.3
Swaraj, S.4
Cowan, C.5
Mostafa, S.M.6
Wenstone, R.7
Leuwer, M.8
-
25
-
-
0037352554
-
Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
-
Reuter D., Bayerlein J., Goepfert M., Weis F., Kilger E., Lamm P., Goetz A., Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients, INTENSIVE CARE MED., 29, 476-480, 2003. (Pubitemid 36379453)
-
(2003)
Intensive Care Medicine
, vol.29
, Issue.3
, pp. 476-480
-
-
Reuter, D.A.1
Bayerlein, J.2
Goepfert, M.S.G.3
Weis, F.C.4
Kilger, E.5
Lamm, P.6
Goetz, A.E.7
-
26
-
-
0037906107
-
Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
-
DOI 10.1097/01.CCM.0000059442.37548.E1
-
Reuter D., Kirchner A., Felbinger T., Weis F., Kilger E., Lamm P., Goetz A., Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function, CRIT. CARE MED., 31, 1399-1404, 2003. (Pubitemid 36583850)
-
(2003)
Critical Care Medicine
, vol.31
, Issue.5
, pp. 1399-1404
-
-
Reuter, D.A.1
Kirchner, A.2
Felbinger, T.W.3
Weis, F.C.4
Kilger, E.5
Lamm, P.6
Goetz, A.E.7
-
27
-
-
0032734448
-
Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
-
Goedje O., Hoeke K., Lichtwarck-Aschoff M., Faltlhauser A., Lamm P., Reichart B., Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis : comparison with pulmonary arterial thermodilution, CRIT. CARE MED., 27, 2407-2412, 1999.
-
(1999)
Crit. Care Med.
, vol.27
, pp. 2407-2412
-
-
Goedje, O.1
Hoeke, K.2
Lichtwarck-Aschoff, M.3
Faltlhauser, A.4
Lamm, P.5
Reichart, B.6
|