메뉴 건너뛰기




Volumn 44, Issue 5, 2011, Pages 948-954

The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement

Author keywords

Bone remodelling resorption; Cemented cementless fixation; Finite element modelling; Tibial component fixation; Total knee replacement

Indexed keywords

APPARENT DENSITY; BONE RESORPTION; CEMENTED/CEMENTLESS FIXATION; CEMENTLESS; CEMENTLESS FIXATION; DENSITOMETRY; FINITE ELEMENT MODELLING; KNEE JOINT; REMODELLING THEORY; STRESS SHIELDING; TIBIAL COMPONENT; TIBIAL TRAY; TOTAL KNEE REPLACEMENT; UNCEMENTED;

EID: 79952043812     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2010.11.026     Document Type: Article
Times cited : (60)

References (48)
  • 1
    • 38749142862 scopus 로고    scopus 로고
    • Finite element modelling of primary hip stem stability: the effect of interference fit
    • Abdul-Kadir M.R., Hansen U., Klabunde R., Lucas D., Amis A. Finite element modelling of primary hip stem stability: the effect of interference fit. Journal of Biomechanics 2008, 41(3):587-594.
    • (2008) Journal of Biomechanics , vol.41 , Issue.3 , pp. 587-594
    • Abdul-Kadir, M.R.1    Hansen, U.2    Klabunde, R.3    Lucas, D.4    Amis, A.5
  • 5
    • 0019644475 scopus 로고
    • Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia
    • Askew M.J., Lewis J.L. Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia. Journal of Biomechanical Engineering 1981, 103:239-245.
    • (1981) Journal of Biomechanical Engineering , vol.103 , pp. 239-245
    • Askew, M.J.1    Lewis, J.L.2
  • 7
    • 33947593021 scopus 로고    scopus 로고
    • Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacement
    • Au A.G., Raso V.J., Liggins A.B., Amirfazli A. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacement. Journal of Biomechanics 2007, 40:1410-1416.
    • (2007) Journal of Biomechanics , vol.40 , pp. 1410-1416
    • Au, A.G.1    Raso, V.J.2    Liggins, A.B.3    Amirfazli, A.4
  • 8
    • 50249121160 scopus 로고    scopus 로고
    • Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses
    • Baca V., Horak Z., Mikulenka P., Dzupa V. Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses. Medical Engineering and Physics 2008, 30:924-930.
    • (2008) Medical Engineering and Physics , vol.30 , pp. 924-930
    • Baca, V.1    Horak, Z.2    Mikulenka, P.3    Dzupa, V.4
  • 9
    • 33744765817 scopus 로고    scopus 로고
    • Management of bone loss-structural grafts in revision total knee arthroplasty
    • Backstein D., Safir O., Gross A. Management of bone loss-structural grafts in revision total knee arthroplasty. Clinical Orthopaedics and Related Research 2006, 446:104-112.
    • (2006) Clinical Orthopaedics and Related Research , vol.446 , pp. 104-112
    • Backstein, D.1    Safir, O.2    Gross, A.3
  • 13
    • 0019435378 scopus 로고
    • Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants
    • Bobyn J.D., Pilliar R.M., Cameron H.U., Weatherly G.C. Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants. Acta Orthopaedica Scandinavica 1981, 52:145-153.
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , pp. 145-153
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 15
    • 79952039687 scopus 로고    scopus 로고
    • Biomechanical analysis of fixation and bone remodelling of total knee replacement, PhD Thesis, Imperial College London, UK
    • Chong, D.Y.R., 2009. Biomechanical analysis of fixation and bone remodelling of total knee replacement, PhD Thesis, Imperial College London, UK.
    • (2009)
    • Chong, D.Y.R.1
  • 16
    • 77950689711 scopus 로고    scopus 로고
    • Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions
    • Chong D.Y.R., Hansen U.N., Amis A.A. Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions. Journal of Biomechanics 2010, 43(6):1074-1080.
    • (2010) Journal of Biomechanics , vol.43 , Issue.6 , pp. 1074-1080
    • Chong, D.Y.R.1    Hansen, U.N.2    Amis, A.A.3
  • 17
    • 0024848325 scopus 로고
    • Quantitative histologic analysis of tissue growth into porous total knee components
    • Cook S.D., Barrack R.L., Thomas K.A., Haddad R.J. Quantitative histologic analysis of tissue growth into porous total knee components. Journal of Arthroplasty 1989, 4(Supplement 1):S33-S43.
    • (1989) Journal of Arthroplasty , vol.4 , Issue.SUPPL. 1
    • Cook, S.D.1    Barrack, R.L.2    Thomas, K.A.3    Haddad, R.J.4
  • 18
    • 14844331452 scopus 로고    scopus 로고
    • Periprosthetic bone remodeling around a prosthesis for distal femoral tumors-longitudinal follow-up
    • Davis A.M., Damani M., White L.M., Wunder J.S., Griffin A.M., Bell R.S. Periprosthetic bone remodeling around a prosthesis for distal femoral tumors-longitudinal follow-up. Journal of Arthroplasty 2005, 20:219-224.
    • (2005) Journal of Arthroplasty , vol.20 , pp. 219-224
    • Davis, A.M.1    Damani, M.2    White, L.M.3    Wunder, J.S.4    Griffin, A.M.5    Bell, R.S.6
  • 21
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R., Weinans H., van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clinical Orthopaedics and Related Research 1992, 274:124-134.
    • (1992) Clinical Orthopaedics and Related Research , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    van Rietbergen, B.3
  • 22
    • 0034878493 scopus 로고    scopus 로고
    • The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty
    • Jazrawi L.M., Bai B., Kummer F.J., Hiebert R., Stuchin S.A. The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty. Journal of Arthroplasty 2001, 16(6):759-767.
    • (2001) Journal of Arthroplasty , vol.16 , Issue.6 , pp. 759-767
    • Jazrawi, L.M.1    Bai, B.2    Kummer, F.J.3    Hiebert, R.4    Stuchin, S.A.5
  • 23
    • 0032839301 scopus 로고    scopus 로고
    • Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry
    • Karbowski A., Schwitalle M., Eckardt A., Heine J. Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry. Archives of Orthopaedic and Trauma Surgery 1999, 119(8):324-326.
    • (1999) Archives of Orthopaedic and Trauma Surgery , vol.119 , Issue.8 , pp. 324-326
    • Karbowski, A.1    Schwitalle, M.2    Eckardt, A.3    Heine, J.4
  • 24
    • 0033034569 scopus 로고    scopus 로고
    • Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling
    • Kerner J., Huiskes R., van Lenthe G.H., Weinans H., van Rietbergen B., Engh C.A., Amis A.A. Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling. Journal of Biomechanics 1999, 32:695-703.
    • (1999) Journal of Biomechanics , vol.32 , pp. 695-703
    • Kerner, J.1    Huiskes, R.2    van Lenthe, G.H.3    Weinans, H.4    van Rietbergen, B.5    Engh, C.A.6    Amis, A.A.7
  • 26
    • 0034013406 scopus 로고    scopus 로고
    • Changes in bone mineral density at the proximal tibia after total knee arthroplasty: a 2-year follow-up of 28 knees using dual energy X-ray absorptiometry
    • Li M.G., Nilsson K.G. Changes in bone mineral density at the proximal tibia after total knee arthroplasty: a 2-year follow-up of 28 knees using dual energy X-ray absorptiometry. Journal of Orthopaedic Research 2000, 18(1):40-47.
    • (2000) Journal of Orthopaedic Research , vol.18 , Issue.1 , pp. 40-47
    • Li, M.G.1    Nilsson, K.G.2
  • 27
    • 0035145732 scopus 로고    scopus 로고
    • Changes in bone density after cemented total knee arthroplasty-influence of stem design
    • Lonner J.H., Klotz M., Levitz C., Lotke P.A. Changes in bone density after cemented total knee arthroplasty-influence of stem design. Journal of Arthroplasty 2001, 16(1):107-111.
    • (2001) Journal of Arthroplasty , vol.16 , Issue.1 , pp. 107-111
    • Lonner, J.H.1    Klotz, M.2    Levitz, C.3    Lotke, P.A.4
  • 29
    • 0038673390 scopus 로고    scopus 로고
    • Trabecular bone modulus-density relationships depend on anatomic site
    • Morgan E.F., Bayraktar H.H., Keaveny T.M. Trabecular bone modulus-density relationships depend on anatomic site. Journal of Biomechanics 2003, 36:897-904.
    • (2003) Journal of Biomechanics , vol.36 , pp. 897-904
    • Morgan, E.F.1    Bayraktar, H.H.2    Keaveny, T.M.3
  • 30
    • 0028906495 scopus 로고
    • Changes in bone mineral density of the distal femur following uncemented total knee arthroplasty
    • Petersen M.M., Olsen C., Lauritzen J.B., Lund B. Changes in bone mineral density of the distal femur following uncemented total knee arthroplasty. Journal of Arthroplasty 1995, 10(1):7-11.
    • (1995) Journal of Arthroplasty , vol.10 , Issue.1 , pp. 7-11
    • Petersen, M.M.1    Olsen, C.2    Lauritzen, J.B.3    Lund, B.4
  • 32
    • 34249691321 scopus 로고    scopus 로고
    • Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement
    • Saari T., Uvehammer J., Carlsson L., Regnér L., Kärrholm J. Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement. Journal of Orthopaedic Research 2007, 25:798-803.
    • (2007) Journal of Orthopaedic Research , vol.25 , pp. 798-803
    • Saari, T.1    Uvehammer, J.2    Carlsson, L.3    Regnér, L.4    Kärrholm, J.5
  • 33
    • 0031720017 scopus 로고    scopus 로고
    • Total knee arthroplasty with the PFC system-results at a minimum of ten years and survivorship analysis
    • Schai P.A., Thornhill T.S., Scott R.D. Total knee arthroplasty with the PFC system-results at a minimum of ten years and survivorship analysis. Journal of Bone and Joint Surgery, British 1998, 80(5):850-858.
    • (1998) Journal of Bone and Joint Surgery, British , vol.80 , Issue.5 , pp. 850-858
    • Schai, P.A.1    Thornhill, T.S.2    Scott, R.D.3
  • 34
    • 0033059331 scopus 로고    scopus 로고
    • Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?
    • Seki T., Omori G., Koga Y., Suzuki Y., Ishii Y., Takahashi H.E. Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?. Journal of Orthopaedic Science 1999, 4:180-186.
    • (1999) Journal of Orthopaedic Science , vol.4 , pp. 180-186
    • Seki, T.1    Omori, G.2    Koga, Y.3    Suzuki, Y.4    Ishii, Y.5    Takahashi, H.E.6
  • 35
    • 33749846605 scopus 로고    scopus 로고
    • Contributions of muscles, ligaments, and the ground-reaction force to tibiofemoral joint loading during normal gait
    • Shelburne K.B., Torry M.R., Pandy M.G. Contributions of muscles, ligaments, and the ground-reaction force to tibiofemoral joint loading during normal gait. Journal of Orthopaedic Research 2006, 24:1983-1990.
    • (2006) Journal of Orthopaedic Research , vol.24 , pp. 1983-1990
    • Shelburne, K.B.1    Torry, M.R.2    Pandy, M.G.3
  • 36
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
    • Shirazi-Adl A., Dammak M., Paiement G. Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. Journal of Biomedical Materials Research 1993, 27:167-175.
    • (1993) Journal of Biomedical Materials Research , vol.27 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 37
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Søballe K., Hansen E.S., Rasmussen H.B., Jørgensen P.H., Bünger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. Journal of Orthopaedic Research 1992, 10:285-299.
    • (1992) Journal of Orthopaedic Research , vol.10 , pp. 285-299
    • Søballe, K.1    Hansen, E.S.2    Rasmussen, H.B.3    Jørgensen, P.H.4    Bünger, C.5
  • 38
    • 0028929906 scopus 로고
    • Bone ingrowth and wear debris in well-fixed cementless porous-coated tibial components removed from patients
    • Sumner D.R., Kienapfel H., Jacobs J.J., Urban R.M., Turner T.M., Galante J.O. Bone ingrowth and wear debris in well-fixed cementless porous-coated tibial components removed from patients. Journal of Arthroplasty 1995, 10(2):157-167.
    • (1995) Journal of Arthroplasty , vol.10 , Issue.2 , pp. 157-167
    • Sumner, D.R.1    Kienapfel, H.2    Jacobs, J.J.3    Urban, R.M.4    Turner, T.M.5    Galante, J.O.6
  • 41
    • 0029344045 scopus 로고
    • Micromotion analysis of the fixation of total knee tibial component
    • Tissakht M., Eskandari H., Ahmed A.M. Micromotion analysis of the fixation of total knee tibial component. Computers and Structures 1995, 56(2/3):365-375.
    • (1995) Computers and Structures , vol.56 , Issue.2-3 , pp. 365-375
    • Tissakht, M.1    Eskandari, H.2    Ahmed, A.M.3
  • 44
    • 0027628259 scopus 로고
    • Adaptive bone remodeling around bonded noncemented total hip arthroplasty: a comparison between animal experiments and computer simulation
    • Weinans H., Huiskes R., van Rietbergen B., Sumner D.R., Turner T.M., Galante J.O. Adaptive bone remodeling around bonded noncemented total hip arthroplasty: a comparison between animal experiments and computer simulation. Journal of Orthopaedic Research 1993, 11:500-513.
    • (1993) Journal of Orthopaedic Research , vol.11 , pp. 500-513
    • Weinans, H.1    Huiskes, R.2    van Rietbergen, B.3    Sumner, D.R.4    Turner, T.M.5    Galante, J.O.6
  • 46
    • 0035407026 scopus 로고    scopus 로고
    • Long-term followup of the bone-ingrowth ortholoc knee system without a metal-backed patella
    • Whiteside L.A. Long-term followup of the bone-ingrowth ortholoc knee system without a metal-backed patella. Clinical Orthopaedics and Related Research 2001, 388:77-84.
    • (2001) Clinical Orthopaedics and Related Research , vol.388 , pp. 77-84
    • Whiteside, L.A.1
  • 47


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.