메뉴 건너뛰기




Volumn 32, Issue 7, 1999, Pages 695-703

Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling

Author keywords

Adaptation; Bone density; Bone remodelling (remodeling); Bone resorption; Computer simulation

Indexed keywords

BONE; COMPUTER SIMULATION; CORRELATION METHODS; DENSITY (SPECIFIC GRAVITY); FINITE ELEMENT METHOD; HIP PROSTHESES; MATHEMATICAL MODELS;

EID: 0033034569     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(99)00041-X     Document Type: Article
Times cited : (206)

References (31)
  • 2
    • 0023162010 scopus 로고
    • Trabecular bone density and loading history: Regulation of connective tissue biology by mechanical energy
    • Carter, D.R., Fyhrie, D.P., Whalen, R.T., 1987. Trabecular bone density and loading history: regulation of connective tissue biology by mechanical energy. Journal of Biomechanics 20, 785-794.
    • (1987) Journal of Biomechanics , vol.20 , pp. 785-794
    • Carter, D.R.1    Fyhrie, D.P.2    Whalen, R.T.3
  • 3
    • 0017698252 scopus 로고
    • The compressive behavior of bone as a two-phase porous structure
    • Carter, D.R., Hayes, W.C., 1977. The compressive behavior of bone as a two-phase porous structure. Journal of Bone and Joint Surgery, American Volume 59, 954-962.
    • (1977) Journal of Bone and Joint Surgery , vol.59 AMERICAN VOLUME , pp. 954-962
    • Carter, D.R.1    Hayes, W.C.2
  • 5
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh, C.A., Bobyn, J.D., 1988. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clinical Orthopaedics 231, 7-28.
    • (1988) Clinical Orthopaedics , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 6
    • 0023240947 scopus 로고
    • Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh, C.A., Bobyn, J.D., Glassman, A.H., 1987. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. Journal of Bone and Joint Surgery. British Volume 69, 45-55.
    • (1987) Journal of Bone and Joint Surgery. , vol.69 BRITISH VOLUME , pp. 45-55
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 7
    • 0025695691 scopus 로고
    • The case for porous-coated hip implants. The femoral side
    • Engh, C.A., Glassman, A.H., Suthers, K.E., 1990. The case for porous-coated hip implants. The femoral side. Clinical Orthopaedics 261, 63-81.
    • (1990) Clinical Orthopaedics , vol.261 , pp. 63-81
    • Engh, C.A.1    Glassman, A.H.2    Suthers, K.E.3
  • 8
    • 0029033572 scopus 로고
    • Evaluation of bone ingrowth in proximally and extensively porous-coated anatomic medullary locking prostheses retrieved at autopsy
    • Engh, C.A., Hooten Jr., J.P., Zettl Schaffer, K.F., Ghaffarpour, M., McGovern, T.F., Bobyn, J.D., 1995. Evaluation of bone ingrowth in proximally and extensively porous-coated anatomic medullary locking prostheses retrieved at autopsy. Journal of Bone and Joint Surgery. American Volume 77, 903-910.
    • (1995) Journal of Bone and Joint Surgery. , vol.77 AMERICAN VOLUME , pp. 903-910
    • Engh, C.A.1    Hooten J.P., Jr.2    Zettl Schaffer, K.F.3    Ghaffarpour, M.4    McGovern, T.F.5    Bobyn, J.D.6
  • 10
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty
    • American Volume
    • Engh, C.A., McGovern, T.F., Bobyn, J.D., Harris, W.H., 1992. A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. Journal of Bone and Joint Surgery. American Volume 74, 1009-1020.
    • (1992) Journal of Bone and Joint Surgery , vol.74 , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 11
    • 0021526091 scopus 로고
    • A computational method for stress analysis of adaptive elastic materials with a view toward applications in strain-induced bone remodeling
    • Hart, R.T., Davy, D.T., Heiple, K.G., 1984. A computational method for stress analysis of adaptive elastic materials with a view toward applications in strain-induced bone remodeling. Journal of Biomechanical Engineering 106, 342-350.
    • (1984) Journal of Biomechanical Engineering , vol.106 , pp. 342-350
    • Hart, R.T.1    Davy, D.T.2    Heiple, K.G.3
  • 12
    • 0027748808 scopus 로고
    • Stress shielding and bone resorption in THA: Clinical versus computer-simulation studies
    • Huiskes, R., 1993. Stress shielding and bone resorption in THA: clinical versus computer-simulation studies. Acta Orthopaedica Belgica 59 (Suppl. 1), 118-129.
    • (1993) Acta Orthopaedica Belgica , vol.59 , Issue.1 SUPPL. , pp. 118-129
    • Huiskes, R.1
  • 13
    • 0030626368 scopus 로고    scopus 로고
    • Validation of adaptive-bone remodeling simulation models
    • Lowet, G. et al. (Eds). IOS Press, Amsterdam
    • Huiskes, R., 1997. Validation of adaptive-bone remodeling simulation models. In: Lowet, G. et al. (Eds). Bone Research in Biomechanics. IOS Press, Amsterdam, pp. 33-48.
    • (1997) Bone Research in Biomechanics , pp. 33-48
    • Huiskes, R.1
  • 14
    • 0028822681 scopus 로고
    • Preclinical testing of total hip stems. The effects of coating placement
    • Huiskes, R., van Rietbergen, B., 1995. Preclinical testing of total hip stems. The effects of coating placement. Clinical Orthopaedics 319, 64-76.
    • (1995) Clinical Orthopaedics , vol.319 , pp. 64-76
    • Huiskes, R.1    Van Rietbergen, B.2
  • 15
    • 0024461204 scopus 로고
    • Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty
    • Huiskes, R., Weinans, H., Dalstra, M., 1989. Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty. Orthopaedics 12, 1255-1267.
    • (1989) Orthopaedics , vol.12 , pp. 1255-1267
    • Huiskes, R.1    Weinans, H.2    Dalstra, M.3
  • 17
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes, R., Weinans, H., van Rietbergen, B., 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clinical Orthopaedics 274, 124-134.
    • (1992) Clinical Orthopaedics , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    Van Rietbergen, B.3
  • 19
    • 0345716268 scopus 로고
    • Bone mineral density distribution of the proximal femur in patients with unilateral osteoarthritis of the hip: Differences between arthritic and contralateral femurs
    • Orlando, Florida
    • Kale, A.A., Scott, D.F., Gitter, M.F., Choung, S.C., Jaffe, W.L., 1995. Bone mineral density distribution of the proximal femur in patients with unilateral osteoarthritis of the hip: differences between arthritic and contralateral femurs. Proceedings of ORS 41, Orlando, Florida, p. 319.
    • (1995) Proceedings of ORS 41 , pp. 319
    • Kale, A.A.1    Scott, D.F.2    Gitter, M.F.3    Choung, S.C.4    Jaffe, W.L.5
  • 20
    • 0027409719 scopus 로고
    • Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results
    • Kilgus, D.J., Shimaoka, E.E., Tipton, J.S., Eberle, R.W., 1993. Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results. Journal of Bone and Joint Surgery. British Volume 75, 279-287.
    • (1993) Journal of Bone and Joint Surgery. British Volume , vol.75 , pp. 279-287
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4
  • 21
    • 0030028631 scopus 로고    scopus 로고
    • Measurement of bone mineral density by dual-energy X-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem
    • Kiratli, B.J., Checovich, M.M., McBeath, A.A., Wilson, M.A., Heiner, J.P., 1996. Measurement of bone mineral density by dual-energy X-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. Journal of Arthroplasty 11, 184-193.
    • (1996) Journal of Arthroplasty , vol.11 , pp. 184-193
    • Kiratli, B.J.1    Checovich, M.M.2    McBeath, A.A.3    Wilson, M.A.4    Heiner, J.P.5
  • 22
    • 0026464523 scopus 로고
    • Determination of bone mineral density by dual X-ray absorptiometry in patients with uncemented total hip arthroplasty
    • Kiratli, B.J., Heiner, J.P., McBeath, A.A., Wilson, M.A., 1992. Determination of bone mineral density by dual X-ray absorptiometry in patients with uncemented total hip arthroplasty. Journal of Orthopaedic Research 10, 836-844.
    • (1992) Journal of Orthopaedic Research , vol.10 , pp. 836-844
    • Kiratli, B.J.1    Heiner, J.P.2    McBeath, A.A.3    Wilson, M.A.4
  • 26
    • 0027944762 scopus 로고
    • Cortical bone density of the proximal femur following cementless total hip arthroplasty
    • McGovern, T.F., Engh, C.A., Zettl Schaffer, K., Hooten Jr., J.P., 1994. Cortical bone density of the proximal femur following cementless total hip arthroplasty. Clinical Orthopaedics 306, 145-154.
    • (1994) Clinical Orthopaedics , vol.306 , pp. 145-154
    • McGovern, T.F.1    Engh, C.A.2    Zettl Schaffer, K.3    Hooten J.P., Jr.4
  • 28
    • 0030067508 scopus 로고    scopus 로고
    • The influence of clinical factors on periprosthetic bone remodeling
    • Sychterz, C.J., Engh, C.A., 1996. The influence of clinical factors on periprosthetic bone remodeling. Clinical Orthopaedics 322, 285-292.
    • (1996) Clinical Orthopaedics , vol.322 , pp. 285-292
    • Sychterz, C.J.1    Engh, C.A.2
  • 30
    • 0026464525 scopus 로고
    • Effects of material properties of femoral hip components on bone remodeling
    • Weinans, H., Huiskes, R., Grootenboer, H.J., 1992. Effects of material properties of femoral hip components on bone remodeling. Journal of Orthopaedic Research 10, 845-853.
    • (1992) Journal of Orthopaedic Research , vol.10 , pp. 845-853
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 31
    • 0027628259 scopus 로고
    • Adaptive bone remodeling around bonded noncemented total hip arthroplasty: A comparison between animal experiments and computer simulation
    • Weinans, H., Huiskes, R., van Rietbergen, B., Sumner, D.R., Turner, T.M., Galante, J.O., 1993. Adaptive bone remodeling around bonded noncemented total hip arthroplasty: a comparison between animal experiments and computer simulation. Journal of Orthopaedic Research 11, 500-513.
    • (1993) Journal of Orthopaedic Research , vol.11 , pp. 500-513
    • Weinans, H.1    Huiskes, R.2    Van Rietbergen, B.3    Sumner, D.R.4    Turner, T.M.5    Galante, J.O.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.