메뉴 건너뛰기




Volumn 33, Issue 4, 1996, Pages 257-267

Bidirectional friction study of cancellous bone-porous coated metal interface

Author keywords

[No Author keywords available]

Indexed keywords

COATINGS; FINITE ELEMENT METHOD; FRICTION; IMPLANTS (SURGICAL); MATHEMATICAL MODELS; MECHANICAL PROPERTIES; MECHANICAL TESTING; THREE DIMENSIONAL;

EID: 0030561161     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199624)33:4<257::AID-JBM5>3.0.CO;2-O     Document Type: Article
Times cited : (27)

References (15)
  • 1
    • 0015648310 scopus 로고
    • The effect of movement on the bonding of porous metal to bone
    • Cameron, H. U.; Pilliar, R. M.; Macnab I. The effect of movement on the bonding of porous metal to bone. J. Biomed. Mater. Res. 7:301-311; 1973.
    • (1973) J. Biomed. Mater. Res. , vol.7 , pp. 301-311
    • Cameron, H.U.1    Pilliar, R.M.2    Macnab, I.3
  • 2
    • 0017557166 scopus 로고
    • Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants
    • Ducheyne, P.; DeMeester, P.; Aernoudt, E.; Martens, M.; Mulier, J. C. Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants. J. Biomed. Mater. Res. 11:811-838; 1977.
    • (1977) J. Biomed. Mater. Res. , vol.11 , pp. 811-838
    • Ducheyne, P.1    DeMeester, P.2    Aernoudt, E.3    Martens, M.4    Mulier, J.C.5
  • 3
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar, R. M.; Lee, J. M.; Maniatopoulos, C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin. Orthop. Rel. Res. 208:108-113; 1986.
    • (1986) Clin. Orthop. Rel. Res. , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 4
    • 0025513729 scopus 로고
    • Friction properties of the interface between porous-surfaced metals and tibial cancellous bone
    • Rancourt, D.; Shirazi-Adl, A.; Drouin, G. Friction properties of the interface between porous-surfaced metals and tibial cancellous bone. J. Biomed. Mater. Res. 24:1503-1519; 1990.
    • (1990) J. Biomed. Mater. Res. , vol.24 , pp. 1503-1519
    • Rancourt, D.1    Shirazi-Adl, A.2    Drouin, G.3
  • 5
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
    • Shirazi-Adl, A.; Dammak, M.; Paiement, G. Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. J. Biomed. Mater. Res. 27:167-175; 1993.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 6
    • 0026681480 scopus 로고
    • Finite element stress analysis of a push-out test part II: Free interface with nonlinear friction properties
    • Shirazi-Adl, A.; Forcione, A. Finite element stress analysis of a push-out test part II: free interface with nonlinear friction properties. J. Biomech. Eng. 114:155-161; 1992.
    • (1992) J. Biomech. Eng. , vol.114 , pp. 155-161
    • Shirazi-Adl, A.1    Forcione, A.2
  • 7
    • 0031081169 scopus 로고    scopus 로고
    • Analysis of cementless implants using interface nonlinear friction-experimental and finite element studies
    • to appear
    • Dammak, M.; Shirazi-Adl, A.; Zukor, D. Analysis of cementless implants using interface nonlinear friction-experimental and finite element studies. J. Biomech., to appear..
    • J. Biomech.
    • Dammak, M.1    Shirazi-Adl, A.2    Zukor, D.3
  • 8
    • 0012331570 scopus 로고
    • Biomechanical analysis of a porous-surfaced knee implant: A finite element contact problem with nonlinear friction
    • Forcione, A.; Shirazi-Adl, A. Biomechanical analysis of a porous-surfaced knee implant: a finite element contact problem with nonlinear friction. Mech. Eng. Forum, Can. Soc. Mech. Eng. Toronto 2:19-24; 1990.
    • (1990) Mech. Eng. Forum, Can. Soc. Mech. Eng. Toronto , vol.2 , pp. 19-24
    • Forcione, A.1    Shirazi-Adl, A.2
  • 9
    • 0026532138 scopus 로고
    • Consequences of an interference fit on the fixation of porous-coated tibial components in total knee replacement
    • Dawson, J. M.; Bartel, D. L. Consequences of an interference fit on the fixation of porous-coated tibial components in total knee replacement. J. Bone Joint Surg. 74A:233-238; 1992.
    • (1992) J. Bone Joint Surg. , vol.74 A , pp. 233-238
    • Dawson, J.M.1    Bartel, D.L.2
  • 10
    • 38149146205 scopus 로고
    • Comparison of tibial fixations in total knee arthroplasty: An evaluation of stress distribution and interface micromotions
    • Rakotomanana, L. R.; Leyvraz, P. F.; Curnier, A.; Meister, J.-J.; Livio, J.-J. Comparison of tibial fixations in total knee arthroplasty: an evaluation of stress distribution and interface micromotions. The Knee 1:91-99; 1994.
    • (1994) The Knee , vol.1 , pp. 91-99
    • Rakotomanana, L.R.1    Leyvraz, P.F.2    Curnier, A.3    Meister, J.-J.4    Livio, J.-J.5
  • 11
    • 0029344045 scopus 로고
    • Micromotion analysis of the fixation of total knee tibial component
    • Tissakht, A.; Eskandari, H.; Ahmed, A. M. Micromotion analysis of the fixation of total knee tibial component. Comput. Struct. 56:365-375; 1995.
    • (1995) Comput. Struct. , vol.56 , pp. 365-375
    • Tissakht, A.1    Eskandari, H.2    Ahmed, A.M.3
  • 12
  • 13
    • 0024382521 scopus 로고
    • A parametric axisymmetric model study on the interface motions in porous-surfaced tibial implants
    • Shirazi-Adl, A.; Ahmed, A. M. A parametric axisymmetric model study on the interface motions in porous-surfaced tibial implants. Ann. Biomed. Eng. 17:411-421; 1989.
    • (1989) Ann. Biomed. Eng. , vol.17 , pp. 411-421
    • Shirazi-Adl, A.1    Ahmed, A.M.2
  • 14
    • 0021078583 scopus 로고
    • The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
    • Goldstein, S. A.; Wilson, D. L.; Sonstegard, D. A.; Matthews, L. S. The mechanical properties of human tibial trabecular bone as a function of metaphyseal location. J. Biomech. 16:965-969; 1983.
    • (1983) J. Biomech. , vol.16 , pp. 965-969
    • Goldstein, S.A.1    Wilson, D.L.2    Sonstegard, D.A.3    Matthews, L.S.4
  • 15
    • 0022356106 scopus 로고
    • Stress analysis of a condylar knee tibial component: Influence of metaphyseal shell properties and cement injection depth
    • Cheal, E. J.; Hayes, W. C.; Lee, C. H.; Snyder, B. D.; Miller, J. Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth. J. Orthop. Res. 3:424-434; 1985.
    • (1985) J. Orthop. Res. , vol.3 , pp. 424-434
    • Cheal, E.J.1    Hayes, W.C.2    Lee, C.H.3    Snyder, B.D.4    Miller, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.