Volumn 80, Issue 1, 2010, Pages 87-93

Monitoring of periodic anaerobic digestion with flow-through array of miniaturized ion-selective electrodes

Author keywords

Anaerobic digestion; ISE array; Miniaturized ISE

Indexed keywords

FERMENTATION PROCESS; FLOWTHROUGH; FULLY COMPATIBLE; ISE ARRAY; METHANE FERMENTATION; MINIATURIZED ISE; NOVEL APPLICATIONS; NOVEL DESIGN; ON-LINE CONTROLS; PERIODIC CONDITIONS; SENSOR MEASUREMENTS; VOLATILE FATTY ACIDS;

EID: 77957903120     PISSN: 15675394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2010.08.004     Document Type: Article
Times cited : (31)

References (43)
  • 2
    • 12344298706 scopus 로고    scopus 로고
    • Control of an anaerobic reactor towards maximum biogas production
    • Liu J., Olsson G., Mattiasson B. Control of an anaerobic reactor towards maximum biogas production. Water Sci. Technol. 2004, 49:189-198.
    • (2004) Water Sci. Technol. , vol.49 , pp. 189-198
    • Liu, J.1    Olsson, G.2    Mattiasson, B.3
  • 3
    • 22744455456 scopus 로고    scopus 로고
    • Application of the ADM1 model to advanced anaerobic digestion
    • Parker W.J. Application of the ADM1 model to advanced anaerobic digestion. Bioresource Technol. 2005, 96:1832-1842.
    • (2005) Bioresource Technol. , vol.96 , pp. 1832-1842
    • Parker, W.J.1
  • 5
    • 34748826106 scopus 로고    scopus 로고
    • Sensor arrays for liquid sensing - electronic tongue systems
    • Ciosek P., Wróblewski W. Sensor arrays for liquid sensing - electronic tongue systems. Analyst 2007, 132:963-978.
    • (2007) Analyst , vol.132 , pp. 963-978
    • Ciosek, P.1    Wróblewski, W.2
  • 6
    • 1942468809 scopus 로고    scopus 로고
    • A review of gas sensors employed in electronic nose applications
    • Arshak K., Moore E., Lyons G.M., Harris J., Clifford S. A review of gas sensors employed in electronic nose applications. Sensor Rev. 2004, 24:181-198.
    • (2004) Sensor Rev. , vol.24 , pp. 181-198
    • Arshak, K.1    Moore, E.2    Lyons, G.M.3    Harris, J.4    Clifford, S.5
  • 7
    • 37349123903 scopus 로고    scopus 로고
    • Bioelectronic tongue for the simultaneous determination of urea, creatinine and alkaline ions in clinical samples
    • Gutiérrez M., Alegret S., del Valle M. Bioelectronic tongue for the simultaneous determination of urea, creatinine and alkaline ions in clinical samples. Biosens. Bioelectron. 2008, 23:795-802.
    • (2008) Biosens. Bioelectron. , vol.23 , pp. 795-802
    • Gutiérrez, M.1    Alegret, S.2    del Valle, M.3
  • 8
    • 0000177855 scopus 로고    scopus 로고
    • Taste sensor
    • Toko K. Taste sensor. Sens. Actuators B 2000, 64:205-215.
    • (2000) Sens. Actuators B , vol.64 , pp. 205-215
    • Toko, K.1
  • 9
    • 51449117462 scopus 로고    scopus 로고
    • Voltammetric electronic tongues - basic principles and applications
    • Winquist F. Voltammetric electronic tongues - basic principles and applications. Microchim. Acta 2008, 163:3-10.
    • (2008) Microchim. Acta , vol.163 , pp. 3-10
    • Winquist, F.1
  • 11
    • 0036803030 scopus 로고    scopus 로고
    • Imaging optical sensor arrays
    • Walt D.R. Imaging optical sensor arrays. Curr. Opin. Chem. Biol. 2002, 6:689-695.
    • (2002) Curr. Opin. Chem. Biol. , vol.6 , pp. 689-695
    • Walt, D.R.1
  • 16
    • 33748201246 scopus 로고    scopus 로고
    • Electronic tongue based on chemically modified electrodes and voltammetry for the detection of adulterations in wines
    • Parra V., Arrieta A.A., Fernandez-Escudero J.A., Rodriguez-Mendez M.L., De Saja J.A. Electronic tongue based on chemically modified electrodes and voltammetry for the detection of adulterations in wines. Sens. Actuators B 2006, 118:448-453.
    • (2006) Sens. Actuators B , vol.118 , pp. 448-453
    • Parra, V.1    Arrieta, A.A.2    Fernandez-Escudero, J.A.3    Rodriguez-Mendez, M.L.4    De Saja, J.A.5
  • 17
    • 0037194232 scopus 로고    scopus 로고
    • Determination of calcium and total hardness in natural waters using a potentiometric sensor array
    • Saurina J., Lopez-Aviles E., Le Moal A., Hernandez-Cassou S. Determination of calcium and total hardness in natural waters using a potentiometric sensor array. Anal. Chim. Acta 2002, 464:89-98.
    • (2002) Anal. Chim. Acta , vol.464 , pp. 89-98
    • Saurina, J.1    Lopez-Aviles, E.2    Le Moal, A.3    Hernandez-Cassou, S.4
  • 19
    • 42149195368 scopus 로고    scopus 로고
    • Sensor systems - electronic tongues and electronic noses for the monitoring of biotechnological processes
    • Rudnitskaya A., Legin A. Sensor systems - electronic tongues and electronic noses for the monitoring of biotechnological processes. J. Industrial Microbiol. Biotechnol. 2008, 35:443-451.
    • (2008) J. Industrial Microbiol. Biotechnol. , vol.35 , pp. 443-451
    • Rudnitskaya, A.1    Legin, A.2
  • 22
    • 0038737170 scopus 로고    scopus 로고
    • Monitoring batch fermentation with an electronic tongue
    • Turner C., Rudnitskaya A., Legin A. Monitoring batch fermentation with an electronic tongue. J. Biotechnol. 2003, 103:87-91.
    • (2003) J. Biotechnol. , vol.103 , pp. 87-91
    • Turner, C.1    Rudnitskaya, A.2    Legin, A.3
  • 24
    • 0036798016 scopus 로고    scopus 로고
    • Online monitoring of a bioprocess based on a multi-analyser system and multivariate statistical process modeling
    • Cimander C., Mandenius C.-F. Online monitoring of a bioprocess based on a multi-analyser system and multivariate statistical process modeling. J. Chem. Technol. Biotechnol. 2002, 77:1157-1168.
    • (2002) J. Chem. Technol. Biotechnol. , vol.77 , pp. 1157-1168
    • Cimander, C.1    Mandenius, C.-F.2
  • 25
    • 0037073154 scopus 로고    scopus 로고
    • Sensor fusion for on-line monitoring of yoghurt fermentation
    • Cimander C., Carlsson M., Mandenius C.F. Sensor fusion for on-line monitoring of yoghurt fermentation. J. Biotechnol. 2002, 99:237-248.
    • (2002) J. Biotechnol. , vol.99 , pp. 237-248
    • Cimander, C.1    Carlsson, M.2    Mandenius, C.F.3
  • 26
    • 0031951542 scopus 로고    scopus 로고
    • Sniffing out trouble: use of an electronic nose in bioprocesses
    • Namdev P.K., Alroy Y., Singh V. Sniffing out trouble: use of an electronic nose in bioprocesses. Biotechnol. Prog. 1998, 14:75-78.
    • (1998) Biotechnol. Prog. , vol.14 , pp. 75-78
    • Namdev, P.K.1    Alroy, Y.2    Singh, V.3
  • 27
    • 0037139747 scopus 로고    scopus 로고
    • Monitoring the aroma production during wine-must fermentation with an electronic nose
    • Pinheiro C., Rodrigues C.M., Schafer T., Crespo J.G. Monitoring the aroma production during wine-must fermentation with an electronic nose. Biotechnol. Bioeng. 2001, 77:632-640.
    • (2001) Biotechnol. Bioeng. , vol.77 , pp. 632-640
    • Pinheiro, C.1    Rodrigues, C.M.2    Schafer, T.3    Crespo, J.G.4
  • 30
    • 77957922099 scopus 로고    scopus 로고
    • PN-ISO 15705
    • PN-ISO 15705:2005.
    • (2005)
  • 31
    • 0037057106 scopus 로고    scopus 로고
    • Zirconium(IV)-porphyrins as novel ionophores for fluoride-selective polymeric membrane electrodes
    • Malinowska E., Górski Ł., Meyerhoff M.E. Zirconium(IV)-porphyrins as novel ionophores for fluoride-selective polymeric membrane electrodes. Anal. Chim. Acta 2002, 468:133-141.
    • (2002) Anal. Chim. Acta , vol.468 , pp. 133-141
    • Malinowska, E.1    Górski, Ł.2    Meyerhoff, M.E.3
  • 32
    • 70349515196 scopus 로고    scopus 로고
    • Potentiometric studies and various applications of solid state electrodes based on silicon and epoxy glass structures - an overview
    • Ciosek P., Chudy M., Górski Ł., Grabowska I., Grygołowicz-Pawlak E., Malinowska E., Wróblewski W. Potentiometric studies and various applications of solid state electrodes based on silicon and epoxy glass structures - an overview. Electroanalysis 2009, 21:1895-1905.
    • (2009) Electroanalysis , vol.21 , pp. 1895-1905
    • Ciosek, P.1    Chudy, M.2    Górski, Ł.3    Grabowska, I.4    Grygołowicz-Pawlak, E.5    Malinowska, E.6    Wróblewski, W.7
  • 33
    • 33747842485 scopus 로고    scopus 로고
    • Electronic tongue for flow-through analysis of beverages
    • Ciosek P., Brzózka Z., Wróblewski W. Electronic tongue for flow-through analysis of beverages. Sens. Actuators B 2006, 118:454-460.
    • (2006) Sens. Actuators B , vol.118 , pp. 454-460
    • Ciosek, P.1    Brzózka, Z.2    Wróblewski, W.3
  • 34
    • 34848885222 scopus 로고    scopus 로고
    • Potentiometric electronic tongue based on integrated array of microelectrodes
    • Ciosek P., Mamińska R., Dybko A., Wróblewski W. Potentiometric electronic tongue based on integrated array of microelectrodes. Sens. Actuators B 2007, 127:8-14.
    • (2007) Sens. Actuators B , vol.127 , pp. 8-14
    • Ciosek, P.1    Mamíska, R.2    Dybko, A.3    Wróblewski, W.4
  • 35
    • 77957891973 scopus 로고    scopus 로고
    • Modular flow-through cell of the ion-selective electrode for water quality monitoring, date of application: 21.07.2008 P384364
    • J. Markiewicz, J. Taff, B. Wysocki, W. Wróblewski, Modular flow-through cell of the ion-selective electrode for water quality monitoring, date of application: 21.07.2008 P384364.
    • Markiewicz, J.1    Taff, J.2    Wysocki, B.3    Wróblewski, W.4
  • 36
    • 33846203940 scopus 로고    scopus 로고
    • Performance of selective and partially selective sensors in the recognition of beverages
    • Ciosek P., Wróblewski W. Performance of selective and partially selective sensors in the recognition of beverages. Talanta 2007, 71:738-746.
    • (2007) Talanta , vol.71 , pp. 738-746
    • Ciosek, P.1    Wróblewski, W.2
  • 37
    • 33746639277 scopus 로고    scopus 로고
    • Recognition of growth conditions and metabolic type of plants by a potentiometric electronic tongue
    • Ciosek P., Pokorska B., Romanowska E., Wróblewski The W. recognition of growth conditions and metabolic type of plants by a potentiometric electronic tongue. Electroanalysis 2006, 18:1266-1272.
    • (2006) Electroanalysis , vol.18 , pp. 1266-1272
    • Ciosek, P.1    Pokorska, B.2    Romanowska, E.3    Wróblewski The, W.4
  • 38
    • 51449110027 scopus 로고    scopus 로고
    • The analysis of dialysate fluids with the use of potentiometric electronic tongue
    • Ciosek P., Grabowska I., Brzózka Z., Wróblewski W. The analysis of dialysate fluids with the use of potentiometric electronic tongue. Microchim. Acta 2008, 163:139-145.
    • (2008) Microchim. Acta , vol.163 , pp. 139-145
    • Ciosek, P.1    Grabowska, I.2    Brzózka, Z.3    Wróblewski, W.4
  • 40
    • 65549111703 scopus 로고    scopus 로고
    • Metalloporphyrin-based acetate-selective electrodes as detectors for enzymatic acetylcholine determination in flow-injection analysis system
    • Górski Ł., Mroczkiewicz M., Pietrzak M., Malinowska E. Metalloporphyrin-based acetate-selective electrodes as detectors for enzymatic acetylcholine determination in flow-injection analysis system. Analytica Chim. Acta 2009, 644:30-35.
    • (2009) Analytica Chim. Acta , vol.644 , pp. 30-35
    • Górski, Ł.1    Mroczkiewicz, M.2    Pietrzak, M.3    Malinowska, E.4
  • 41
    • 77952101026 scopus 로고    scopus 로고
    • The monitoring of methane fermentation in sequencing batch bioreactor with flow-through array of miniaturized solid state electrodes
    • Buczkowska A., Witkowska E., Górski Ł., Zamojska A., Szewczyk K.W., Wróblewski W., Ciosek P. The monitoring of methane fermentation in sequencing batch bioreactor with flow-through array of miniaturized solid state electrodes. Talanta 2010, 81:1387-1392.
    • (2010) Talanta , vol.81 , pp. 1387-1392
    • Buczkowska, A.1    Witkowska, E.2    Górski, Ł.3    Zamojska, A.4    Szewczyk, K.W.5    Wróblewski, W.6    Ciosek, P.7
  • 42
    • 33244490274 scopus 로고    scopus 로고
    • The analysis of sensor array data with various pattern recognition techniques
    • Ciosek P., Wróblewski W. The analysis of sensor array data with various pattern recognition techniques. Sens. Actuators B 2006, 114:85-93.
    • (2006) Sens. Actuators B , vol.114 , pp. 85-93
    • Ciosek, P.1    Wróblewski, W.2
  • 43
    • 24144484865 scopus 로고    scopus 로고
    • Direct and two stage data analysis procedures based on PCA, PLS-DA and ANN for ISE-based electronic tongue - effect of supervised feature extraction
    • Ciosek P., Brzózka Z., Wróblewski W., Martinelli E., Di Natale C., D'Amico A. Direct and two stage data analysis procedures based on PCA, PLS-DA and ANN for ISE-based electronic tongue - effect of supervised feature extraction. Talanta 2005, 67:590-596.
    • (2005) Talanta , vol.67 , pp. 590-596
    • Ciosek, P.1    Brzózka, Z.2    Wróblewski, W.3    Martinelli, E.4    Di Natale, C.5    D'Amico, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.