-
1
-
-
11244310646
-
Geometric misalignment and calibration in cone-beam tomography
-
DOI 10.1118/1.1803792
-
L. von Smekal, M. KachelrieΒ, E. Stepina, and W. A. Kalender, " Geometric misalignment and calibration in cone-beam tomography.," Med. Phys. 0094-2405 31, 3242-3266 (2004). 10.1118/1.1803792 (Pubitemid 40064977)
-
(2004)
Medical Physics
, vol.31
, Issue.12
, pp. 3242-3266
-
-
Von Smekal, L.1
Kachelriess, M.2
Stepina, E.3
Kalender, W.A.4
-
2
-
-
58149252286
-
Simultaneous misalignment correction for approximate circular cone-beam computed tomography
-
0031-9155,. 10.1088/0031-9155/53/22/001
-
Y. Kyriakou, R. M. Lapp, L. Hillebrand, D. Ertel, and W. A. Kalender, " Simultaneous misalignment correction for approximate circular cone-beam computed tomography.," Phys. Med. Biol. 0031-9155 53, 6267-6289 (2008). 10.1088/0031-9155/53/22/001
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 6267-6289
-
-
Kyriakou, Y.1
Lapp, R.M.2
Hillebrand, L.3
Ertel, D.4
Kalender, W.A.5
-
3
-
-
42949159662
-
Geometric calibration for a dual tube/detector micro-CT system
-
DOI 10.1118/1.2900000
-
S. M. Johnston, G. A. Johnson, and C. T. Badea, " Geometric calibration for a dual tube/detector micro-CT system.," Med. Phys. 0094-2405 35, 1820-1829 (2008). 10.1118/1.2900000 (Pubitemid 351614796)
-
(2008)
Medical Physics
, vol.35
, Issue.5
, pp. 1820-1829
-
-
Johnston, S.M.1
Johnson, G.A.2
Badea, C.T.3
-
4
-
-
0041374210
-
Improving 3D image quality of x-ray c-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry
-
0277-786X,. 10.1117/12.479945
-
N. K. Strobel, B. Heigl, T. M. Brunner, O. Schuetz, M. M. Mitschke, K. Wiesent, and T. Mertelmeier, " Improving 3D image quality of x-ray c-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry.," Proc. SPIE 0277-786X 5030, 943-954 (2003). 10.1117/12.479945
-
(2003)
Proc. SPIE
, vol.5030
, pp. 943-954
-
-
Strobel, N.K.1
Heigl, B.2
Brunner, T.M.3
Schuetz, O.4
Mitschke, M.M.5
Wiesent, K.6
Mertelmeier, T.7
-
5
-
-
0034926538
-
Alignment of a volumetric tomography system
-
DOI 10.1118/1.1382609
-
G. M. Stevens, R. Saunders, and N. J. Pelc, " Alignment of a volumetric tomography system.," Med. Phys. 0094-2405 28, 1472-1481 (2001). 10.1118/1.1382609 (Pubitemid 32667289)
-
(2001)
Medical Physics
, vol.28
, Issue.7
, pp. 1472-1481
-
-
Stevens, G.M.1
Saunders, R.2
Pelc, N.J.3
-
6
-
-
0025349536
-
Estimation of geometrical parameters and collimator evaluation for cone beam tomography
-
DOI 10.1118/1.596505
-
G. T. Gullberg, B. M. W. Tsui, C. R. Crawford, J. G. Ballard, and J. T. Hagius, " Estimation of geometrical parameters and collimator evaluation for cone beam tomography.," Med. Phys. 0094-2405 17, 264-272 (1990). 10.1118/1.596505 (Pubitemid 20140145)
-
(1990)
Medical Physics
, vol.17
, Issue.2
, pp. 264-272
-
-
Gullberg, G.T.1
Tsui, B.M.W.2
Crawford, C.R.3
Ballard, J.G.4
Hagius, J.T.5
-
7
-
-
0033781494
-
Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
-
0031-9155,. 10.1088/0031-9155/45/11/327
-
F. Noo, R. Clackdoyle, C. Mennessier, T. A. White, and T. J. Roney, " Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.," Phys. Med. Biol. 0031-9155 45, 3489-3508 (2000). 10.1088/0031-9155/45/11/327
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 3489-3508
-
-
Noo, F.1
Clackdoyle, R.2
Mennessier, C.3
White, T.A.4
Roney, T.J.5
-
8
-
-
17844380035
-
Accurate technique for complete geometric calibration of cone-beam computed tomography systems
-
DOI 10.1118/1.1869652
-
Y. Cho, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray, " Accurate technique for complete geometric calibration of cone-beam computed tomography systems.," Med. Phys. 0094-2405 32, 968-983 (2005). 10.1118/1.1869652 (Pubitemid 40586782)
-
(2005)
Medical Physics
, vol.32
, Issue.4
, pp. 968-983
-
-
Cho, Y.1
Moseley, D.J.2
Siewerdsen, J.H.3
Jaffray, D.A.4
-
9
-
-
33846622496
-
-
in 2005 IEEE Nuclear Science Symposium Conference Record, Vol.
-
G. Strubel, R. Clackdoyle, C. Mennessier, and F. Noo, " Analytic calibration of cone-beam scanners.," in 2005 IEEE Nuclear Science Symposium Conference Record, 2005, Vol. 5, pp. 2731-2735.
-
(2005)
Analytic Calibration of Cone-beam Scanners
, vol.5
, pp. 2731-2735
-
-
Strubel, G.1
Clackdoyle, R.2
Mennessier, C.3
Noo, F.4
-
10
-
-
33744794934
-
A geometric calibration method for cone beam CT systems
-
DOI 10.1118/1.2198187
-
K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, " A geometric calibration method for cone beam CT systems.," Med. Phys. 0094-2405 33, 1695-1706 (2006). 10.1118/1.2198187 (Pubitemid 43830258)
-
(2006)
Medical Physics
, vol.33
, Issue.6
, pp. 1695-1706
-
-
Yang, K.1
Kwan, A.L.C.2
Miller, D.F.3
Boone, J.M.4
-
11
-
-
47649113588
-
An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms
-
DOI 10.1088/0031-9155/53/14/009, PII S003191550867760X
-
D. Panetta, N. Belcari, A. D. Guerra, and S. Moehrs, " An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms.," Phys. Med. Biol. 0031-9155 53, 3841-3861 (2008). 10.1088/0031-9155/53/14/009 (Pubitemid 352020270)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.14
, pp. 3841-3861
-
-
Panetta, D.1
Belcari, N.2
Del Guerra, A.3
Moehrs, S.4
-
12
-
-
63649101026
-
Direct determination of geometric alignment parameters for cone-beam scanners
-
0031-9155,. 10.1088/0031-9155/54/6/016
-
C. Mennessier, R. Clackdoyle, and F. Noo, " Direct determination of geometric alignment parameters for cone-beam scanners.," Phys. Med. Biol. 0031-9155 54, 1633-1660 (2009). 10.1088/0031-9155/54/6/016
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 1633-1660
-
-
Mennessier, C.1
Clackdoyle, R.2
Noo, F.3
-
13
-
-
33745389197
-
A perspective matrix-based seed reconstruction algorithm with applications to C-arm based intra-operative dosimetry
-
DOI 10.1117/12.653474, Medical Imaging 2006: Visualization, Image-Guided Procedures, and Display
-
S. Narayanan and P. S. Cho, " A perspective matrix-based seed reconstruction algorithm with applications to C-arm based intra-operative dosimetry.," Proc. SPIE 0277-786X 6141, 61411I (2006). 10.1117/12.653474 (Pubitemid 43944807)
-
(2006)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.6141
-
-
Narayanan, S.1
Cho, P.S.2
-
14
-
-
33745368663
-
Design and development of C-arm based cone-beam CT for image-guided interventions: Initial results
-
DOI 10.1117/12.653197, Medical Imaging 2006: Physics of Medical Imaging
-
G. H. Chen, J. Zambelli, B. E. Nett, M. Supanich, C. Riddell, B. Belanger, and C. A. Mistretta, " Design and development of C-arm based cone-beam CT for image-guided interventions: Initial results.," Proc. SPIE 0277-786X 6142, 614210 (2006). 10.1117/12.653197 (Pubitemid 43944886)
-
(2006)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.I6142
, pp. 614210
-
-
Chen, G.-H.1
Zambelli, J.2
Nett, B.E.3
Supanich, M.4
Riddell, C.5
Belanger, B.6
Mistretta, C.A.7
-
15
-
-
36348939322
-
Geometric calibration of the circle-plus-arc trajectory
-
DOI 10.1088/0031-9155/52/23/012, PII S0031915507571447
-
S. Hoppe, F. Noo, F. Dennerlein, G. Lauritsch, and J. Hornegger, " Geometric calibration of the circle-plus-arc trajectory.," Phys. Med. Biol. 0031-9155 52, 6943-6960 (2007). 10.1088/0031-9155/52/23/012 (Pubitemid 350150624)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.23
, pp. 6943-6960
-
-
Hoppe, S.1
Noo, F.2
Dennerlein, F.3
Lauritsch, G.4
Hornegger, J.5
-
16
-
-
0034178299
-
Enhanced 3-D-reconstruction algorithm for c-arm systems suitable for interventional procedures
-
0278-0062,. 10.1109/42.870250
-
K. Wiesent, K. Barth, N. Navab, P. Durlak, T. Brunner, O. Schuetz, and W. Seissler, " Enhanced 3-D-reconstruction algorithm for c-arm systems suitable for interventional procedures.," IEEE Trans. Med. Imaging 0278-0062 19, 391-403 (2000). 10.1109/42.870250
-
(2000)
IEEE Trans. Med. Imaging
, vol.19
, pp. 391-403
-
-
Wiesent, K.1
Barth, K.2
Navab, N.3
Durlak, P.4
Brunner, T.5
Schuetz, O.6
Seissler, W.7
-
17
-
-
0033954113
-
Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
-
DOI 10.1118/1.598854
-
R. Fahrig and D. W. Holdsworth, " Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities.," Med. Phys. 0094-2405 27, 30-38 (2000). 10.1118/1.598854 (Pubitemid 30051908)
-
(2000)
Medical Physics
, vol.27
, Issue.1
, pp. 30-38
-
-
Fahrig, R.1
Holdsworth, D.W.2
-
18
-
-
0029713961
-
Dynamic geometrical calibration for 3D cerebral angiography
-
0277-786X,. 10.1117/12.237798
-
N. Navab, A. R. Bani-Hashemi, M. M. Mitschke, D. W. Holdsworth, R. Fahrig, A. J. Fox, and R. Graumann, " Dynamic geometrical calibration for 3D cerebral angiography.," Proc. SPIE 0277-786X 2708, 361-370 (1996). 10.1117/12.237798
-
(1996)
Proc. SPIE
, vol.2708
, pp. 361-370
-
-
Navab, N.1
Bani-Hashemi, A.R.2
Mitschke, M.M.3
Holdsworth, D.W.4
Fahrig, R.5
Fox, A.J.6
Graumann, R.7
-
19
-
-
71949115061
-
The geometric calibration of cone-beam systems with arbitrary geometry
-
0031-9155,. 10.1088/0031-9155/54/24/001
-
N. Robert, K. N. Watt, X. Wang, and J. G. Mainprize, " The geometric calibration of cone-beam systems with arbitrary geometry.," Phys. Med. Biol. 0031-9155 54, 7239-7261 (2009). 10.1088/0031-9155/54/24/001
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 7239-7261
-
-
Robert, N.1
Watt, K.N.2
Wang, X.3
Mainprize, J.G.4
-
20
-
-
35048817828
-
Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs
-
DOI 10.1117/12.713813, Medical Imaging 2007: Physics of Medical Imaging
-
J. Zambelli, B. E. Nett, S. Leng, C. Riddell, B. Belanger, and G. H. Chen, " Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs.," Proc. SPIE 0277-786X 6510, 65101Q (2007). 10.1117/12.713813 (Pubitemid 47550151)
-
(2007)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.6510
, Issue.PART 1
-
-
Zambelli, J.1
Nett, B.E.2
Leng, S.3
Riddell, C.4
Belanger, B.5
Chen, G.-H.6
-
21
-
-
35148816682
-
Digital Breast Tomosynthesis geometry calibration
-
DOI 10.1117/12.698714, Medical Imaging 2007: Physics of Medical Imaging
-
X. Wang, J. G. Mainprize, M. P. Kempston, G. E. Mawdsley, and M. J. Yaffe, " Digital breast tomosynthesis geometry calibration.," Proc. SPIE 0277-786X 6510, 65103B (2007). 10.1117/12.698714 (Pubitemid 47550220)
-
(2007)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.6510
, Issue.PART 2
-
-
Wang, X.1
Mainprize, J.G.2
Kempston, M.P.3
Mawdsley, G.E.4
Yaffe, M.J.5
-
23
-
-
0022808786
-
A computational approach to edge detection
-
0162-8828,. 10.1109/TPAMI.1986.4767851
-
J. Canny, " A computational approach to edge detection.," IEEE Trans. Pattern Anal. Mach. Intell. 0162-8828 PAMI-8, 679-698 (1986). 10.1109/TPAMI.1986.4767851
-
(1986)
IEEE Trans. Pattern Anal. Mach. Intell.
, vol.PAMI-8
, pp. 679-698
-
-
Canny, J.1
-
24
-
-
77954740553
-
-
from MathWorld-A Wolfram Web Resource.
-
E. W. Weisstein, " Ellipse.," from MathWorld-A Wolfram Web Resource (http://mathworld.wolfram.com/Ellipse.html).
-
Ellipse
-
-
Weisstein, E.W.1
-
25
-
-
77954714508
-
Camera calibration with lens distortion and from vanishing points
-
0091-3286,. 10.1117/1.3070650
-
B. He and Y. Li, " Camera calibration with lens distortion and from vanishing points.," Opt. Eng. (Bellingham) 0091-3286 48, 013603 (2009). 10.1117/1.3070650
-
(2009)
Opt. Eng. (Bellingham)
, vol.48
, pp. 013603
-
-
He, B.1
Li, Y.2
-
26
-
-
27744448086
-
-
Mathematical and Computational Sciences Division, National Institute of Standards and Technology.
-
R. Pozo, " Template Numerical Toolkit.," Mathematical and Computational Sciences Division, National Institute of Standards and Technology (http://math.nist.gov/tnt/index.html).
-
Template Numerical Toolkit
-
-
Pozo, R.1
-
27
-
-
0034230377
-
Underwater video mosaics as visual navigation maps
-
1077-3142,. 10.1006/cviu.2000.0848
-
N. Gracias and J. Santos-Victor, " Underwater video mosaics as visual navigation maps.," Comput. Vis. Image Underst. 1077-3142 79, 66-91 (2000). 10.1006/cviu.2000.0848
-
(2000)
Comput. Vis. Image Underst.
, vol.79
, pp. 66-91
-
-
Gracias, N.1
Santos-Victor, J.2
-
28
-
-
77954702644
-
Quantifying breast density with a cone-beam breast CT
-
0277-786X,. 10.1117/12.844369
-
X. Li and B. Liu, " Quantifying breast density with a cone-beam breast CT.," Proc. SPIE 0277-786X 7622, 762245 (2010). 10.1117/12.844369
-
(2010)
Proc. SPIE
, vol.7622
, pp. 762245
-
-
Li, X.1
Liu, B.2
-
30
-
-
0021952059
-
Fast calculation of the exact radiological path for a three-dimensional CT array
-
DOI 10.1118/1.595715
-
R. L. Siddon, " Fast calculation of the exact radiological path for a three-dimensional CT array.," Med. Phys. 0094-2405 12, 252-255 (1985). 10.1118/1.595715 (Pubitemid 15089015)
-
(1985)
Medical Physics
, vol.12
, Issue.2
, pp. 252-255
-
-
Siddon, R.L.1
-
31
-
-
34147110778
-
Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware
-
DOI 10.1118/1.2710328
-
M. KachelrieΒ, M. Knaup, and O. Bockenbach, " Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.," Med. Phys. 0094-2405 34, 1474-1486 (2007). 10.1118/1.2710328 (Pubitemid 46555777)
-
(2007)
Medical Physics
, vol.34
, Issue.4
, pp. 1474-1486
-
-
Kachelriess, M.1
Knaup, M.2
Bockenbach, O.3
-
32
-
-
23844452192
-
Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector
-
DOI 10.1117/12.595833, 61, Medical Imaging 2005 - Physics of Medical Imaging
-
B. Ren, C. Ruth, J. Stein, A. Smith, I. Shaw, and Z. Jing, " Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector.," Proc. SPIE 0277-786X 5745, 550-561 (2005). 10.1117/12.595833 (Pubitemid 41146402)
-
(2005)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.5745
, Issue.I
, pp. 550-561
-
-
Ren, B.1
Ruth, C.2
Stein, J.3
Smith, A.4
Shaw, I.5
Jing, Z.6
-
33
-
-
85027230055
-
-
See supplementary material E-MPHYA6-37-048006 at for C++ source code and sample data.
-
See supplementary material E-MPHYA6-37-048006 at http://www.aip.org/ pubservs/epaps.html for C++ source code and sample data.
-
-
-
|