메뉴 건너뛰기




Volumn 7622, Issue PART 3, 2010, Pages

Quantifying breast density with a cone-beam breast CT

Author keywords

Breast CT; Breast density; Image reconstruction; Simulation

Indexed keywords

3-D MAPPING; ATTENUATION COEFFICIENT; BEAM HARDENING; BREAST CT; BREAST DENSITY; CONE ANGLE; CONE-BEAM BREAST CT; DIFFERENT SIZES; FILTERED BACK-PROJECTION; HIGH QUALITY; IMAGE CONTRASTS; IMAGING NOISE; LINEAR ATTENUATION COEFFICIENTS; PIXEL VALUES; PROJECTION IMAGE; RAY-TRACING ALGORITHM; RECONSTRUCTED IMAGE; REDUCTION ALGORITHMS; SIMULATION; TISSUE ASSESSMENTS; TISSUE COMPOSITION; TISSUE DENSITY; VOLUMETRIC BREAST DENSITIES;

EID: 77954702644     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.844369     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 55749094194 scopus 로고    scopus 로고
    • Mammographic density. Measurement of mammographic density
    • M. J. Yaffe, "Mammographic density. Measurement of mammographic density," Breast Cancer Res. 10, 209 (2008).
    • (2008) Breast Cancer Res. , vol.10 , pp. 209
    • Yaffe, M.J.1
  • 2
    • 39549083444 scopus 로고    scopus 로고
    • Basic physics and doubts about relationship between mammographically determined tissue density and breast cancer risk
    • D. B. Kopans, "Basic physics and doubts about relationship between mammographically determined tissue density and breast cancer risk," Radiology 246, 348-353 (2008).
    • (2008) Radiology , vol.246 , pp. 348-353
    • Kopans, D.B.1
  • 4
    • 84873900398 scopus 로고    scopus 로고
    • Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms
    • Lake Buena Vista, FL, February 7-12
    • T. Han et al., "Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms," SPIE Medical Imaging Conferences, Paper 7258-20, Lake Buena Vista, FL, February 7-12, 2009.
    • (2009) SPIE Medical Imaging Conferences, Paper 7258-20
    • Han, T.1
  • 6
    • 33645000127 scopus 로고    scopus 로고
    • Technique factors and their relationship to radiation dose in pendant geometry breast CT
    • J. M. Boone et al., "Technique factors and their relationship to radiation dose in pendant geometry breast CT," Med. Phys. 32, 3767-3776 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3767-3776
    • Boone, J.M.1
  • 7
    • 0022362613 scopus 로고
    • Prism representation: A 3D ray-tracing algorithm for radiotherapy applications
    • R. L. Siddon, "Prism representation: a 3D ray-tracing algorithm for radiotherapy applications," Phys. Med. Biol. 30, 817-824 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 817-824
    • Siddon, R.L.1
  • 8
    • 34147110778 scopus 로고    scopus 로고
    • Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware
    • M. KachelrieB, M. Knaup and O. Bockenbach, "Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware," Med. Phys. 34, 1474-1486 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 1474-1486
    • Kachelrie, M.B.1    Knaup, M.2    Bockenbach, O.3
  • 10
    • 0034178299 scopus 로고    scopus 로고
    • Enhanced 3-d-reconstruction algorithm for c-arm systems suitable for interventional procedures
    • K. Wiesent et al., "Enhanced 3-d-reconstruction algorithm for c-arm systems suitable for interventional procedures", IEEE Trans, on Medical Imaging 19, 391-403(2000).
    • (2000) IEEE Trans, on Medical Imaging , vol.19 , pp. 391-403
    • Wiesent, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.