메뉴 건너뛰기




Volumn 6510, Issue PART 1, 2007, Pages

Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs

Author keywords

CT; SYS

Indexed keywords

CC TRAJECTORY; GEOMETRICAL CALIBRATION; TUY'S SUFFICIENCY CONDITION;

EID: 35048817828     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.713813     Document Type: Conference Paper
Times cited : (9)

References (23)
  • 1
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • D. A. Jaffray and J. H. Siewerdsen, "Cone-beam computed tomography with a flat-panel imager: initial performance characterization," Med. Phys. 27, pp. 1311-1320, 2000.
    • (2000) Med. Phys , vol.27 , pp. 1311-1320
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 2
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • B. Chen and R. Ning, "Cone-beam volume CT breast imaging: Feasibility study," Med. Phys. 29, pp. 755-770, 2002.
    • (2002) Med. Phys , vol.29 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 3
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • J. M. Boone, T. R. Nelson, K. K. Lindfors, and J. A. Seibert, "Dedicated breast CT: radiation dose and image quality evaluation," Radiology 221, pp. 657-667, 2001.
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 4
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • Jan
    • J. H. Siewerdsen, D. J. Moseley, S. Burch, S. K. Bisland, A. Bogaards, B. C. Wilson, and D. A. Jaffray, "Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery," Med Phys 32, pp. 241-54, Jan 2005.
    • (2005) Med Phys , vol.32 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3    Bisland, S.K.4    Bogaards, A.5    Wilson, B.C.6    Jaffray, D.A.7
  • 5
    • 0031546042 scopus 로고    scopus 로고
    • Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
    • Sep
    • R. Fahrig, A. J. Fox, S. Lownie, and D. W. Holdsworth, "Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results," AJNR Am J Neuroradiol 18, pp. 1507-14, Sep 1997.
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1507-1514
    • Fahrig, R.1    Fox, A.J.2    Lownie, S.3    Holdsworth, D.W.4
  • 7
    • 0020764170 scopus 로고
    • An inverse formula for cone-beam reconstruction
    • H. K. Tuy, "An inverse formula for cone-beam reconstruction," SIAM J. Appl. Math 43, pp. 546-552, 1983.
    • (1983) SIAM J. Appl. Math , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 8
    • 20044372762 scopus 로고    scopus 로고
    • Image reconstruction for the circle-and-arc trajectory
    • A. Katsevich, "Image reconstruction for the circle-and-arc trajectory," Phys. Med. Biol. 50, pp. 2249-2265, 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 2249-2265
    • Katsevich, A.1
  • 10
    • 28044458793 scopus 로고    scopus 로고
    • Theory and algorithms for image reconstruction on chords and within regions of interest
    • Y. Zou, X. Pan, and E. Sidky, "Theory and algorithms for image reconstruction on chords and within regions of interest," J. Opt. Soc. Am. A 22, pp. 2372-2384, 2005.
    • (2005) J. Opt. Soc. Am. A , vol.22 , pp. 2372-2384
    • Zou, Y.1    Pan, X.2    Sidky, E.3
  • 11
    • 11844249976 scopus 로고    scopus 로고
    • Cone-beam reconstruction using backprojection of locally-filtered projections
    • J. D. Pack, F. Noo, and R. Clackdoyle, "Cone-beam reconstruction using backprojection of locally-filtered projections," IEEE Trans. Med. Imag. 24, pp. 70-85, 2005.
    • (2005) IEEE Trans. Med. Imag , vol.24 , pp. 70-85
    • Pack, J.D.1    Noo, F.2    Clackdoyle, R.3
  • 13
    • 0019375532 scopus 로고
    • Dose minimization in computed tomography overscanning
    • D. L. Parker, V. Smith, and J. Stanley, "Dose minimization in computed tomography overscanning," Med. Phys. 8, pp. 706-711, 1981.
    • (1981) Med. Phys , vol.8 , pp. 706-711
    • Parker, D.L.1    Smith, V.2    Stanley, J.3
  • 14
    • 33745091253 scopus 로고    scopus 로고
    • A cone-beam reconstruction algorithm for two concentric arcs using an equal weighting scheme
    • T. Zhuang, B. E. Nett, S. Leng, and G. H. Chen, "A cone-beam reconstruction algorithm for two concentric arcs using an equal weighting scheme," Phys. Med. Biol. 51, pp. 3189-3210, 2006.
    • (2006) Phys. Med. Biol , vol.51 , pp. 3189-3210
    • Zhuang, T.1    Nett, B.E.2    Leng, S.3    Chen, G.H.4
  • 16
    • 4444346222 scopus 로고    scopus 로고
    • General reconstruction theory for multislice X-ray computed tomography with a gantry tilt
    • F. Noo, M. Defrise, and H. Kudo, "General reconstruction theory for multislice X-ray computed tomography with a gantry tilt," IEEE Trans. Med. Imag. 23, pp. 1109-1116, 2004.
    • (2004) IEEE Trans. Med. Imag , vol.23 , pp. 1109-1116
    • Noo, F.1    Defrise, M.2    Kudo, H.3
  • 17
    • 0042903710 scopus 로고    scopus 로고
    • A general scheme for constructing inversion algorithms for cone-beam CT
    • A. Katsevich, "A general scheme for constructing inversion algorithms for cone-beam CT," Int. J. Math. Sci. 21, pp. 1305-1321, 2003.
    • (2003) Int. J. Math. Sci , vol.21 , pp. 1305-1321
    • Katsevich, A.1
  • 18
    • 0345733891 scopus 로고    scopus 로고
    • An alternative derivation of Katsevich's cone-beam reconstruction formula
    • G. H. Chen, "An alternative derivation of Katsevich's cone-beam reconstruction formula," Med. Phys. 30, pp. 3217-3226, 2003.
    • (2003) Med. Phys , vol.30 , pp. 3217-3226
    • Chen, G.H.1
  • 19
    • 0027637986 scopus 로고
    • Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction
    • Jul-Oct
    • A. Rougee, C. Picard, C. Ponchut, and Y. Trousset, "Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction," Comput Med Imaging Graph 17, pp. 295-300, Jul-Oct 1993.
    • (1993) Comput Med Imaging Graph , vol.17 , pp. 295-300
    • Rougee, A.1    Picard, C.2    Ponchut, C.3    Trousset, Y.4
  • 21
  • 22
    • 0020030616 scopus 로고
    • Optimal short-scan convolution reconstruction for fan beam CT
    • D. L. Parker, "Optimal short-scan convolution reconstruction for fan beam CT," Med. Phys. 9, pp. 254-257, 1982.
    • (1982) Med. Phys , vol.9 , pp. 254-257
    • Parker, D.L.1
  • 23
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. Crawford and K. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys. 17, pp. 967-982, 1990.
    • (1990) Med. Phys , vol.17 , pp. 967-982
    • Crawford, C.1    King, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.