메뉴 건너뛰기




Volumn 5030 II, Issue , 2003, Pages 943-954

Improving 3D image quality of X-ray C-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry

Author keywords

C arm cone beam image reconstruction; Calibration phantom; Irregular projection geometry

Indexed keywords

IMAGE QUALITY; IMAGE RECONSTRUCTION; PROJECTION SYSTEMS; X RAY ANALYSIS;

EID: 0041374210     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.479945     Document Type: Conference Paper
Times cited : (53)

References (17)
  • 1
    • 0034257874 scopus 로고    scopus 로고
    • Flat panel detector-based cone beam volume CT angiography imaging: System evaluation
    • R. Ning, B. Chen, R. Yu, D. Conover, et al., "Flat panel detector-based cone beam volume CT angiography imaging: System evaluation, " IEEE Transactions Medical Imaging 19(9), pp. 949-963, 2000.
    • (2000) IEEE Transactions Medical Imaging , vol.19 , Issue.9 , pp. 949-963
    • Ning, R.1    Chen, B.2    Yu, R.3    Conover, D.4
  • 3
    • 0033746345 scopus 로고    scopus 로고
    • Online geometrical calibration of a mobile c-arm using external sensors
    • M. Mitschke, N. Navab, and O. Schütz, "Online geometrical calibration of a mobile c-arm using external sensors," in SPIE Proceedings, 3976, pp. 580-587, 2000.
    • (2000) SPIE Proceedings , vol.3976 , pp. 580-587
    • Mitschke, M.1    Navab, N.2    Schütz, O.3
  • 4
    • 0033954113 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a c-arm mounted XRII: Image-based correction of gantry motion nonidealities
    • R. Fahrig and D. W. Holdsworth, "Three-dimensional computed tomographic reconstruction using a c-arm mounted XRII: Image-based correction of gantry motion nonidealities," Medical Physics 27(1), pp. 30-38, 2000.
    • (2000) Medical Physics , vol.27 , Issue.1 , pp. 30-38
    • Fahrig, R.1    Holdsworth, D.W.2
  • 5
    • 84947795740 scopus 로고    scopus 로고
    • 3D reconstruction from projection matrices in a c-arm based 3D-angiography system
    • N. Navab, A. Bani-Hashemi, M. S. Nadar, et al., "3D reconstruction from projection matrices in a c-arm based 3D-angiography system," in Proceedings MICCAI, pp. 119-129, 1998.
    • (1998) Proceedings MICCAI , pp. 119-129
    • Navab, N.1    Bani-Hashemi, A.2    Nadar, M.S.3
  • 6
    • 0027719512 scopus 로고
    • Geometrical calibration for 3D x-ray imaging
    • A. Rougée, C. Picard, Y. Trousset, et al., "Geometrical calibration for 3D x-ray imaging," in SPIE Proceedings, 1897, pp. 161-169, 1993.
    • (1993) SPIE Proceedings , vol.1897 , pp. 161-169
    • Rougée, A.1    Picard, C.2    Trousset, Y.3
  • 8
    • 0033704283 scopus 로고    scopus 로고
    • Determination and correction of the wobble of a c-arm gantry
    • M. D. Silver, A. Sen., and S. Oish, "Determination and correction of the wobble of a c-arm gantry," in SPIE Proceedings, 3979, pp. 1459-1467, 2000.
    • (2000) SPIE Proceedings , vol.3979 , pp. 1459-1467
    • Silver, M.D.1    Sen, A.2    Oish, S.3
  • 9
    • 0034178299 scopus 로고    scopus 로고
    • Enhanced 3d-reconstruction algorithm for c-arm systems suitable for interventional procedures
    • K. Wiesent, K. Barth, N. Navab, et al., "Enhanced 3d-reconstruction algorithm for c-arm systems suitable for interventional procedures," IEEE Transactions on Medical Imaging 19(5), pp. 391-403, 2000.
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.5 , pp. 391-403
    • Wiesent, K.1    Barth, K.2    Navab, N.3
  • 11
    • 0037347370 scopus 로고    scopus 로고
    • Recovering the x-ray projection geometry for three-dimensional tomographic reconstruction with additional sensors: Attached camera versus external navigation system
    • M. Mitschke and N. Navab, "Recovering the x-ray projection geometry for three-dimensional tomographic reconstruction with additional sensors: Attached camera versus external navigation system," Medical Image Analysis 7(1), pp. 65-78, 2003.
    • (2003) Medical Image Analysis , vol.7 , Issue.1 , pp. 65-78
    • Mitschke, M.1    Navab, N.2
  • 15
    • 0028414092 scopus 로고
    • An investigation on the accuracy of three-dimensional space reconstruction using the direct linear transformation technique
    • L. Chen, C. W. Armstrong, and D. D. Raftopoulos, "An investigation on the accuracy of three-dimensional space reconstruction using the direct linear transformation technique," J. Biomechanics 27(4), pp. 493-500, 1994.
    • (1994) J. Biomechanics , vol.27 , Issue.4 , pp. 493-500
    • Chen, L.1    Armstrong, C.W.2    Raftopoulos, D.D.3
  • 16
    • 0027637986 scopus 로고
    • Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction
    • A. Rougée, C. Picard, Y. Trousset, and C. Ponchut, "Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction," Computerized Medical Imaging and Graphics 17(4/5), pp. 295-300, 1993.
    • (1993) Computerized Medical Imaging and Graphics , vol.17 , Issue.4-5 , pp. 295-300
    • Rougée, A.1    Picard, C.2    Trousset, Y.3    Ponchut, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.