메뉴 건너뛰기




Volumn 108, Issue 6, 2009, Pages 939-945

Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION; HUMAN; IMAGE QUALITY; INJURY; INSTRUMENTATION; METHODOLOGY; PATHOLOGY; RADIOGRAPHY; SENSITIVITY AND SPECIFICITY; TOOTH FRACTURE; TOOTH RADIOGRAPHY; TOOTH ROOT;

EID: 71849103328     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2009.07.041     Document Type: Article
Times cited : (108)

References (25)
  • 1
    • 34548552850 scopus 로고    scopus 로고
    • The potential applications of cone beam tomography in the management of endodontic problems
    • Patel S., Dawood A., Ford T.P., and Whaites E. The potential applications of cone beam tomography in the management of endodontic problems. Int Endod J 40 (2007) 818-830
    • (2007) Int Endod J , vol.40 , pp. 818-830
    • Patel, S.1    Dawood, A.2    Ford, T.P.3    Whaites, E.4
  • 2
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
    • Ludlow J.B., and Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106 (2008) 106-114
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2
  • 3
    • 58849163662 scopus 로고    scopus 로고
    • Effective dose from cone beam CT examinations in dentistry
    • Roberts J.A., Drage N.A., Davies J., and Thomas D.W. Effective dose from cone beam CT examinations in dentistry. Br J Radiol 82 (2009) 35-40
    • (2009) Br J Radiol , vol.82 , pp. 35-40
    • Roberts, J.A.1    Drage, N.A.2    Davies, J.3    Thomas, D.W.4
  • 5
    • 52049112120 scopus 로고    scopus 로고
    • Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications
    • Tyndall D.A., and Rathore S. Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications. Dent Clin North Am 52 (2008) 825-841
    • (2008) Dent Clin North Am , vol.52 , pp. 825-841
    • Tyndall, D.A.1    Rathore, S.2
  • 6
    • 13144294052 scopus 로고    scopus 로고
    • High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro
    • Wenzel A., and Kirkevang L.-L. High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro. Dent Traumatol 21 (2005) 32-35
    • (2005) Dent Traumatol , vol.21 , pp. 32-35
    • Wenzel, A.1    Kirkevang, L.-L.2
  • 7
    • 62649140145 scopus 로고    scopus 로고
    • Detection of root fractures using cone beam computed tomography: a case report
    • Ilgüy D., Ilgüy M., Fisekcioglu E., and Bayili G. Detection of root fractures using cone beam computed tomography: a case report. Dentomaxillofac Radiol 38 (2009) 169-173
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 169-173
    • Ilgüy, D.1    Ilgüy, M.2    Fisekcioglu, E.3    Bayili, G.4
  • 8
    • 34249033347 scopus 로고    scopus 로고
    • In vitro assessment of local computed tomography for the detection of longitudinal tooth fractures
    • Mora M.A., Mol A., Tyndall D.A., and Rivera E.M. In vitro assessment of local computed tomography for the detection of longitudinal tooth fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) 825-829
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , pp. 825-829
    • Mora, M.A.1    Mol, A.2    Tyndall, D.A.3    Rivera, E.M.4
  • 9
    • 65349107985 scopus 로고    scopus 로고
    • Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan
    • Hassan B., Metska M.E., Ozok A.R., van der Stelt P., and Wesselink P.R. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 35 (2009) 719-722
    • (2009) J Endod , vol.35 , pp. 719-722
    • Hassan, B.1    Metska, M.E.2    Ozok, A.R.3    van der Stelt, P.4    Wesselink, P.R.5
  • 12
    • 33748936726 scopus 로고    scopus 로고
    • A review of dentists' use of digital radiography and caries diagnosis with digital systems
    • Wenzel A. A review of dentists' use of digital radiography and caries diagnosis with digital systems. Dentomaxillofac Radiol 35 (2006) 307-314
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 307-314
    • Wenzel, A.1
  • 13
    • 57749194252 scopus 로고    scopus 로고
    • Effect of digital noise filters on diagnostic radiographs for the diagnosis of experimental root fractures
    • Brüllmann D., Witzel V., Willershausen B., and d'Hoedt B. Effect of digital noise filters on diagnostic radiographs for the diagnosis of experimental root fractures. Int J Comput Dent 11 (2008) 107-114
    • (2008) Int J Comput Dent , vol.11 , pp. 107-114
    • Brüllmann, D.1    Witzel, V.2    Willershausen, B.3    d'Hoedt, B.4
  • 17
    • 45949111844 scopus 로고    scopus 로고
    • Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study
    • Tsesis I.K., Katz A., Tamse A., Kaffe I., and Kfir A. Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106 (2008) 124-128
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 124-128
    • Tsesis, I.K.1    Katz, A.2    Tamse, A.3    Kaffe, I.4    Kfir, A.5
  • 18
    • 38949161444 scopus 로고    scopus 로고
    • Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    • Haiter-Neto F., Wenzel A., and Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37 (2008) 18-22
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 18-22
    • Haiter-Neto, F.1    Wenzel, A.2    Gotfredsen, E.3
  • 19
    • 33847095850 scopus 로고    scopus 로고
    • Influence of spatial resolution and bit depth on detection of small caries lesions with digital receptors
    • Wenzel A., Haiter-Neto F., and Gotfredsen E. Influence of spatial resolution and bit depth on detection of small caries lesions with digital receptors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) 418-422
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , pp. 418-422
    • Wenzel, A.1    Haiter-Neto, F.2    Gotfredsen, E.3
  • 20
    • 0027639992 scopus 로고
    • Perception of image quality in direct digital radiography after application of various image treatment filters for detectability of dental disease
    • Wenzel A., and Hintze H. Perception of image quality in direct digital radiography after application of various image treatment filters for detectability of dental disease. Dentomaxillofac Radiol 22 (1993) 131-134
    • (1993) Dentomaxillofac Radiol , vol.22 , pp. 131-134
    • Wenzel, A.1    Hintze, H.2
  • 21
    • 0033125114 scopus 로고    scopus 로고
    • Digital radiography of interproximal caries: Effect of different filters
    • Eickholz P., Kolb I., Lenhard M.H., and Staehle H.J. Digital radiography of interproximal caries: Effect of different filters. Caries Res 33 (1999) 234-241
    • (1999) Caries Res , vol.33 , pp. 234-241
    • Eickholz, P.1    Kolb, I.2    Lenhard, M.H.3    Staehle, H.J.4
  • 23
    • 14544297428 scopus 로고    scopus 로고
    • Effect of digital filtering on the measurement of the depth of proximal caries under different exposure conditions
    • Koob A., Sanden E., Hassfeld S., Staehle H.J., and Eickholz P. Effect of digital filtering on the measurement of the depth of proximal caries under different exposure conditions. Am J Dent 17 (2004) 388-393
    • (2004) Am J Dent , vol.17 , pp. 388-393
    • Koob, A.1    Sanden, E.2    Hassfeld, S.3    Staehle, H.J.4    Eickholz, P.5
  • 24
    • 57649180085 scopus 로고    scopus 로고
    • Task-specific enhancement filters in storage phosphor images from the Vistascan system for detection of proximal caries lesions of known size
    • Haiter-Neto F., Casanova M.S., Frydenberg M., and Wenzel A. Task-specific enhancement filters in storage phosphor images from the Vistascan system for detection of proximal caries lesions of known size. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107 (2009) 116-121
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 116-121
    • Haiter-Neto, F.1    Casanova, M.S.2    Frydenberg, M.3    Wenzel, A.4
  • 25
    • 0033128750 scopus 로고    scopus 로고
    • Digital radiography of interproximal bone loss; validity of different filters
    • Eickholz P., Riess T., Lenhard M., Hassfeld S., and Staehle H.J. Digital radiography of interproximal bone loss; validity of different filters. J Clin Periodontol 26 (1999) 294-300
    • (1999) J Clin Periodontol , vol.26 , pp. 294-300
    • Eickholz, P.1    Riess, T.2    Lenhard, M.3    Hassfeld, S.4    Staehle, H.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.