-
1
-
-
0035487689
-
Clinical application of a new compact CT-system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible. A case report
-
Ito K., Gomi Y., Sato S., et al. Clinical application of a new compact CT-system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible. A case report. Clin Oral Implants Res 12 (2001) 539-542
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 539-542
-
-
Ito, K.1
Gomi, Y.2
Sato, S.3
-
2
-
-
14244264415
-
Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
-
Lascala C.A., Panella J., and Marques M.M. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol 33 (2004) 291-294
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 291-294
-
-
Lascala, C.A.1
Panella, J.2
Marques, M.M.3
-
3
-
-
14044259241
-
Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint
-
Honda K., Arai Y., Kashima M., et al. Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint. Dentomaxillofac Radiol 33 (2004) 391-395
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 391-395
-
-
Honda, K.1
Arai, Y.2
Kashima, M.3
-
4
-
-
0036490726
-
Clinical indications for digital volume tomography in oral and maxillofacial surgery
-
Ziegler C.M., Woertche R., Briefand J., et al. Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 31 (2002) 126-130
-
(2002)
Dentomaxillofac Radiol
, vol.31
, pp. 126-130
-
-
Ziegler, C.M.1
Woertche, R.2
Briefand, J.3
-
5
-
-
0032240404
-
A new volumetric CT machine for dental imaging based on the conebeam technique: preliminary results
-
Mozzo P., Procacci C., Tacconi A., et al. A new volumetric CT machine for dental imaging based on the conebeam technique: preliminary results. Eur Radiol 8 (1998) 1558-1564
-
(1998)
Eur Radiol
, vol.8
, pp. 1558-1564
-
-
Mozzo, P.1
Procacci, C.2
Tacconi, A.3
-
6
-
-
1542468397
-
Cone beam volume tomography: a new digital imaging option for dentistry
-
Danforth R.A. Cone beam volume tomography: a new digital imaging option for dentistry. J Calif Dent Assoc 31 (2003) 814-815
-
(2003)
J Calif Dent Assoc
, vol.31
, pp. 814-815
-
-
Danforth, R.A.1
-
7
-
-
0642365211
-
Cone beam computed tomography in craniofacial imaging
-
Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthod Craniofac Res 6 Suppl 1 (2003) 31-36
-
(2003)
Orthod Craniofac Res
, vol.6
, Issue.SUPPL. 1
, pp. 31-36
-
-
Sukovic, P.1
-
8
-
-
22244457956
-
Imaging of maxillofacial trauma: evolutions and emerging revolutions
-
Scarfe C.S. Imaging of maxillofacial trauma: evolutions and emerging revolutions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 100 (2005) 575-596
-
(2005)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.100
, pp. 575-596
-
-
Scarfe, C.S.1
-
9
-
-
0017120860
-
Lesion conspicuity, structured noise, and film reader error
-
Kundel H.L., and Revesz G. Lesion conspicuity, structured noise, and film reader error. Am J Roentgenol 126 (1976) 1233-1238
-
(1976)
Am J Roentgenol
, vol.126
, pp. 1233-1238
-
-
Kundel, H.L.1
Revesz, G.2
-
11
-
-
1542402171
-
Imaging methods in periodontology
-
Mol A. Imaging methods in periodontology. Periodontol 2004 34 (2000) 34-38
-
(2000)
Periodontol
, vol.2004
, Issue.34
, pp. 34-38
-
-
Mol, A.1
-
12
-
-
0030621857
-
Tuned-aperture computed tomography (TACT): theory and application for 3-D dentoalveolar imaging
-
Webber R.L., Horton R.A., Tyndall D.A., et al. Tuned-aperture computed tomography (TACT): theory and application for 3-D dentoalveolar imaging. Dentomaxillofac Radiol 26 (1997) 53-62
-
(1997)
Dentomaxillofac Radiol
, vol.26
, pp. 53-62
-
-
Webber, R.L.1
Horton, R.A.2
Tyndall, D.A.3
-
14
-
-
0032014051
-
The effects of restorative material and lesion location on recurrent caries detection for Ektaspeed Plus film; direct digital radiography, and tuned aperture computed tomography (TACT)
-
Nair M.K., Tyndall D.A., Ludlow J.B., et al. The effects of restorative material and lesion location on recurrent caries detection for Ektaspeed Plus film; direct digital radiography, and tuned aperture computed tomography (TACT). Dentomaxillofac Radiol 27 (1998) 80-84
-
(1998)
Dentomaxillofac Radiol
, vol.27
, pp. 80-84
-
-
Nair, M.K.1
Tyndall, D.A.2
Ludlow, J.B.3
-
15
-
-
0033122376
-
Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography
-
Abreu M., Tyndall D.A., Platin E., et al. Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography. Dentomaxillofac Radiol 28 3 (1999) 152-157
-
(1999)
Dentomaxillofac Radiol
, vol.28
, Issue.3
, pp. 152-157
-
-
Abreu, M.1
Tyndall, D.A.2
Platin, E.3
-
16
-
-
0347560522
-
Diagnosis of external root resorption using TACT (tuned aperture computed tomography)
-
Nance R.S., Tyndall D.A., Levin L.G., et al. Diagnosis of external root resorption using TACT (tuned aperture computed tomography). Endodont and Trauma 16 1 (2000) 24-28
-
(2000)
Endodont and Trauma
, vol.16
, Issue.1
, pp. 24-28
-
-
Nance, R.S.1
Tyndall, D.A.2
Levin, L.G.3
-
17
-
-
0034231423
-
Identification of root canals in molars by tuned-aperture computed tomography
-
Nance R.S., Tyndall D.A., Levin L.G., et al. Identification of root canals in molars by tuned-aperture computed tomography. Int Endod J 33 4 (2000) 392-396
-
(2000)
Int Endod J
, vol.33
, Issue.4
, pp. 392-396
-
-
Nance, R.S.1
Tyndall, D.A.2
Levin, L.G.3
-
18
-
-
0035513629
-
Evaluation of tuned aperture computed tomography (TACT) in the localization of simulated periodontal defects
-
Ramesh A., Ludlow J.B., Webber R.L., et al. Evaluation of tuned aperture computed tomography (TACT) in the localization of simulated periodontal defects. Dentomaxillofac Radiol 30 6 (2001) 319-324
-
(2001)
Dentomaxillofac Radiol
, vol.30
, Issue.6
, pp. 319-324
-
-
Ramesh, A.1
Ludlow, J.B.2
Webber, R.L.3
-
19
-
-
33746041477
-
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and I-Cat
-
Ludlow J.B., Davies-Ludlow L.E., Brooks S.L., et al. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and I-Cat. Dentomaxillofac Radiol 35 (2006) 219-226
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 219-226
-
-
Ludlow, J.B.1
Davies-Ludlow, L.E.2
Brooks, S.L.3
-
20
-
-
0030076467
-
In vitro comparison of Kodak ultra-speed, Ektaspeed, and Ektaspeed plus, and Agfa M2 comfort dental x-ray films for the detection of caries
-
Hintze H., Christoffersen L., and Wenzel A. In vitro comparison of Kodak ultra-speed, Ektaspeed, and Ektaspeed plus, and Agfa M2 comfort dental x-ray films for the detection of caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 81 (1996) 240-244
-
(1996)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.81
, pp. 240-244
-
-
Hintze, H.1
Christoffersen, L.2
Wenzel, A.3
-
21
-
-
0031616798
-
Reliability of visual examination, fibre-optic transillumination, and bitewing radiography, and reproducibility of direct visual examination following tooth separation for the identification of cavitated carious lesions in contacting approximal surfaces
-
Hintze H., Wenzel A., Danielsen B., et al. Reliability of visual examination, fibre-optic transillumination, and bitewing radiography, and reproducibility of direct visual examination following tooth separation for the identification of cavitated carious lesions in contacting approximal surfaces. Caries Res 32 (1998) 204-209
-
(1998)
Caries Res
, vol.32
, pp. 204-209
-
-
Hintze, H.1
Wenzel, A.2
Danielsen, B.3
-
22
-
-
0028708602
-
In vitro comparison of D- and E-speed film radiography, RVG, and Visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions
-
Hintze H., Wenzel A., and Jones C. In vitro comparison of D- and E-speed film radiography, RVG, and Visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions. Caries Res 28 (1994) 363-367
-
(1994)
Caries Res
, vol.28
, pp. 363-367
-
-
Hintze, H.1
Wenzel, A.2
Jones, C.3
-
23
-
-
0029395646
-
Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study
-
Wenzel A., Borg E., Hintze H., et al. Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study. Dentomaxillofac Radiol 24 (1995) 250-254
-
(1995)
Dentomaxillofac Radiol
, vol.24
, pp. 250-254
-
-
Wenzel, A.1
Borg, E.2
Hintze, H.3
-
24
-
-
0030622295
-
Comparative performance of digital and conventional images for detecting proximal surface caries
-
White S.C., and Yoon D.C. Comparative performance of digital and conventional images for detecting proximal surface caries. Dentomaxillofac Radiol 26 (1997) 32-38
-
(1997)
Dentomaxillofac Radiol
, vol.26
, pp. 32-38
-
-
White, S.C.1
Yoon, D.C.2
-
25
-
-
0032110022
-
Alternative extraoral radiographic imaging of primary caries
-
Clifton T.L., Tyndall D.A., and Ludlow J.B. Alternative extraoral radiographic imaging of primary caries. Dentomaxillofac Radiol 27 (1998) 193-198
-
(1998)
Dentomaxillofac Radiol
, vol.27
, pp. 193-198
-
-
Clifton, T.L.1
Tyndall, D.A.2
Ludlow, J.B.3
-
29
-
-
14044270678
-
Minimum number of basis projections for caries detection with local CT
-
van Daatselaar A.N., Tyndall D.A., Verheij H., et al. Minimum number of basis projections for caries detection with local CT. Dentomaxillofac Radiol 33 (2004) 355-360
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 355-360
-
-
van Daatselaar, A.N.1
Tyndall, D.A.2
Verheij, H.3
-
31
-
-
33646768211
-
Accuracy of proximal caries depth measurements: comparison between limited cone-beam CT, storage phosphor and film radiography
-
Akdeniz B.G., Gröndahl H.G., and Magnusson B. Accuracy of proximal caries depth measurements: comparison between limited cone-beam CT, storage phosphor and film radiography. Caries Res 40 (2006) 202-207
-
(2006)
Caries Res
, vol.40
, pp. 202-207
-
-
Akdeniz, B.G.1
Gröndahl, H.G.2
Magnusson, B.3
-
32
-
-
34547873534
-
Evaluation of limited cone-beam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries
-
Tsuchida R., Araki K., and Tomohiro Okano T. Evaluation of limited cone-beam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104 (2007) 412-416
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 412-416
-
-
Tsuchida, R.1
Araki, K.2
Tomohiro Okano, T.3
-
33
-
-
38949161444
-
Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
-
Haiter-Neto F., Wenzel A., and Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37 (2008) 18-22
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 18-22
-
-
Haiter-Neto, F.1
Wenzel, A.2
Gotfredsen, E.3
-
34
-
-
0029338040
-
Assessment of alveolar bone loss with high resolution computed tomography
-
Fuhrmann R.A.W., Bücker A., and Diedrich P.R. Assessment of alveolar bone loss with high resolution computed tomography. J Periodont Res 30 (1995) 258-263
-
(1995)
J Periodont Res
, vol.30
, pp. 258-263
-
-
Fuhrmann, R.A.W.1
Bücker, A.2
Diedrich, P.R.3
-
35
-
-
0029240902
-
Assessment of the dentate alveolar process with high resolution computed tomography
-
Fuhrmann R.A., Wehrbein H., Langen H.J., et al. Assessment of the dentate alveolar process with high resolution computed tomography. Dentomaxillofac Radiol 24 (1995) 50-54
-
(1995)
Dentomaxillofac Radiol
, vol.24
, pp. 50-54
-
-
Fuhrmann, R.A.1
Wehrbein, H.2
Langen, H.J.3
-
36
-
-
0032063138
-
Three-dimensional alveolar bone morphology analysis using computed tomography
-
Naito T., Hosokawa R., and Yokota M. Three-dimensional alveolar bone morphology analysis using computed tomography. J Periodontol 69 (1998) 584-589
-
(1998)
J Periodontol
, vol.69
, pp. 584-589
-
-
Naito, T.1
Hosokawa, R.2
Yokota, M.3
-
38
-
-
34547960968
-
Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown
-
Vandenberghe B., Jacobs R., and Yang J. Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104 (2007) 395-401
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 395-401
-
-
Vandenberghe, B.1
Jacobs, R.2
Yang, J.3
-
39
-
-
33748518930
-
Accuracy of cone beam computed tomography for periodontal defect measurements
-
Misch K.A., Yi E.S., and Sarment D.P. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 77 (2006) 1261-1266
-
(2006)
J Periodontol
, vol.77
, pp. 1261-1266
-
-
Misch, K.A.1
Yi, E.S.2
Sarment, D.P.3
-
40
-
-
20744434589
-
Digital volume tomography in the diagnosis of periodontal defects: an in vitro study on native pig and human mandibles
-
Mengel R., Candir M., Shiratori K., et al. Digital volume tomography in the diagnosis of periodontal defects: an in vitro study on native pig and human mandibles. J Periodontol 76 5 (2005) 665-673
-
(2005)
J Periodontol
, vol.76
, Issue.5
, pp. 665-673
-
-
Mengel, R.1
Candir, M.2
Shiratori, K.3
-
41
-
-
52049104589
-
Evaluation of high-resolution cone-beam computed tomography in the detection of simulated interradicular bone lesions
-
Noujeim M., Nummikoski P., and Langlais R. Evaluation of high-resolution cone-beam computed tomography in the detection of simulated interradicular bone lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) e52
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.103
-
-
Noujeim, M.1
Nummikoski, P.2
Langlais, R.3
-
42
-
-
40549094662
-
Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
-
Loubele M., van Assche N., Carpentier K., et al. Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105 (2008) 512-518
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.105
, pp. 512-518
-
-
Loubele, M.1
van Assche, N.2
Carpentier, K.3
-
43
-
-
52049120502
-
In vitro cone beam computed tomography imaging of periodontal bone
-
Mol A., and Balasundaram A. In vitro cone beam computed tomography imaging of periodontal bone. Dentomaxillofac Radiol 37 (2008) 1-6
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 1-6
-
-
Mol, A.1
Balasundaram, A.2
-
44
-
-
33644639722
-
Clinical applications of cone-beam computed tomography in dental practice
-
Scarfe W.C., Farman A.G., and Sukovis P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 72 (2006) 75-80
-
(2006)
J Can Dent Assoc
, vol.72
, pp. 75-80
-
-
Scarfe, W.C.1
Farman, A.G.2
Sukovis, P.3
-
45
-
-
34548433121
-
Digital volume tomography for diagnostics in periodontology
-
Kasaj A., and Willershausen B. Digital volume tomography for diagnostics in periodontology. Int J Comput Dent 10 2 (2007) 155-168
-
(2007)
Int J Comput Dent
, vol.10
, Issue.2
, pp. 155-168
-
-
Kasaj, A.1
Willershausen, B.2
-
46
-
-
34249656423
-
Accuracy of cone beam dental CT, intra oral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws
-
Stavropoulos A., and Wenzel A. Accuracy of cone beam dental CT, intra oral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws. Clin Oral Investig 1 (2007) 101-106
-
(2007)
Clin Oral Investig
, vol.1
, pp. 101-106
-
-
Stavropoulos, A.1
Wenzel, A.2
-
47
-
-
0001626054
-
Roentgenographic and direct observation of experimental lesions in bone I
-
Bender B., and Seltzer S. Roentgenographic and direct observation of experimental lesions in bone I. J Am Dent Assoc 62 (1961) 152-160
-
(1961)
J Am Dent Assoc
, vol.62
, pp. 152-160
-
-
Bender, B.1
Seltzer, S.2
-
48
-
-
0001626055
-
Roentgenographic and direct observation of experimental lesions in bone II
-
Bender B., and Seltzer S. Roentgenographic and direct observation of experimental lesions in bone II. J Am Dent Ass 62 (1961) 708-716
-
(1961)
J Am Dent Ass
, vol.62
, pp. 708-716
-
-
Bender, B.1
Seltzer, S.2
-
49
-
-
3242722713
-
Radiological aspects of apical periodontitis
-
Huumonen S., and Ørstavik D. Radiological aspects of apical periodontitis. Endodontic Topics 1 (2002) 3-25
-
(2002)
Endodontic Topics
, vol.1
, pp. 3-25
-
-
Huumonen, S.1
Ørstavik, D.2
-
50
-
-
33846254175
-
Digital and advanced imaging in endodontics: a review
-
Nair M., and Nair U. Digital and advanced imaging in endodontics: a review. J Endod 33 1 (2007) 1-6
-
(2007)
J Endod
, vol.33
, Issue.1
, pp. 1-6
-
-
Nair, M.1
Nair, U.2
-
51
-
-
34249033347
-
In vitro assessment of local computed tomography for the detection of longitudinal tooth fractures
-
Mora M.A., Mol A., Tyndall D.A., et al. In vitro assessment of local computed tomography for the detection of longitudinal tooth fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) 825-829
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.103
, pp. 825-829
-
-
Mora, M.A.1
Mol, A.2
Tyndall, D.A.3
-
52
-
-
33747333666
-
Differential diagnosis of large periapical lesions using cone-beam computed tomography measurements and biopsy
-
Simon J., Reyes E., Malfaz J.-M., et al. Differential diagnosis of large periapical lesions using cone-beam computed tomography measurements and biopsy. J Endod 32 (2006) 833-837
-
(2006)
J Endod
, vol.32
, pp. 833-837
-
-
Simon, J.1
Reyes, E.2
Malfaz, J.-M.3
-
53
-
-
34547935381
-
Endodontic applications of cone-beam volumetric tomography
-
Cotton T.P., Geilser M.G., Holden D.T., et al. Endodontic applications of cone-beam volumetric tomography. J Endod 33 (2007) 1121-1132
-
(2007)
J Endod
, vol.33
, pp. 1121-1132
-
-
Cotton, T.P.1
Geilser, M.G.2
Holden, D.T.3
-
54
-
-
38949147127
-
Resorption: within or without? The benefit of cone-beam computed tomography when diagnosing a case of an internal/external resorption defect
-
Maini A., Durning P., and Drage N. Resorption: within or without? The benefit of cone-beam computed tomography when diagnosing a case of an internal/external resorption defect. Braz Dent J 204 (2008) 135-137
-
(2008)
Braz Dent J
, vol.204
, pp. 135-137
-
-
Maini, A.1
Durning, P.2
Drage, N.3
-
55
-
-
26444548977
-
Three-dimensional localization of maxillary canines with cone-beam computed tomography
-
Walker L., Enciso R., and Mah J. Three-dimensional localization of maxillary canines with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 128 (2005) 418-423
-
(2005)
Am J Orthod Dentofacial Orthop
, vol.128
, pp. 418-423
-
-
Walker, L.1
Enciso, R.2
Mah, J.3
-
56
-
-
1542681130
-
Vestibular surgical access to the palatine root of the superior first molar: "low-dose cone-beam" CT analysis of the pathway and its anatomic variations
-
Rigolone M., Pasqualini D., Bianchi L., et al. Vestibular surgical access to the palatine root of the superior first molar: "low-dose cone-beam" CT analysis of the pathway and its anatomic variations. J Endod 29 (2003) 773-775
-
(2003)
J Endod
, vol.29
, pp. 773-775
-
-
Rigolone, M.1
Pasqualini, D.2
Bianchi, L.3
-
57
-
-
33846993332
-
A new cone beam computerized tomography system for use in endodontic surgery
-
Tsurumachi T., and Honda K. A new cone beam computerized tomography system for use in endodontic surgery. Int Endod J 40 (2007) 224-232
-
(2007)
Int Endod J
, vol.40
, pp. 224-232
-
-
Tsurumachi, T.1
Honda, K.2
-
58
-
-
34548552850
-
The potential applications of cone beam computed tomography in the management of endodontic problems
-
Patel S., Dawood A., Pitt Ford T., et al. The potential applications of cone beam computed tomography in the management of endodontic problems. Int Endod J 40 (2007) 818-830
-
(2007)
Int Endod J
, vol.40
, pp. 818-830
-
-
Patel, S.1
Dawood, A.2
Pitt Ford, T.3
-
60
-
-
33847003650
-
Imaging of root canal fillings: a comparison of subjective image quality between limited conebeam CT, storage phosphor and film radiography
-
Sogur E., Baks B.G., and Grö ndahl H.-G. Imaging of root canal fillings: a comparison of subjective image quality between limited conebeam CT, storage phosphor and film radiography. Int Endod J 40 (2007) 179-185
-
(2007)
Int Endod J
, vol.40
, pp. 179-185
-
-
Sogur, E.1
Baks, B.G.2
Grö ndahl, H.-G.3
|