메뉴 건너뛰기




Volumn 33, Issue 2, 2010, Pages 346-351

Evaluation of magnetic resonance imaging-compatible needles and interactive sequences for musculoskeletal interventions using an open high-field magnetic resonance imaging scanner

Author keywords

Interventional radiology; Open high field MRI; Passive needle tracking; Susceptibility artefact; Thermometry

Indexed keywords

ARTICLE; ARTIFACT; BONE RADIOGRAPHY; CONTROLLED STUDY; FLUOROSCOPY; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IN VITRO STUDY; INTERVENTIONAL RADIOLOGY; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; SIGNAL NOISE RATIO; SPINAL CORD DECOMPRESSION; THERMOMETRY;

EID: 77952800572     PISSN: 01741551     EISSN: 1432086X     Source Type: Journal    
DOI: 10.1007/s00270-009-9676-6     Document Type: Article
Times cited : (28)

References (27)
  • 1
    • 11244296125 scopus 로고    scopus 로고
    • Interventional and intraoperative MR: Review and update of techniques and clinical experience
    • Schulz T, Puccini S, Schneider JP Kahn T (2004) Interventional and intraoperative MR: review and update of techniques and clinical experience. Eur Radiol 14(12):2212-2227
    • (2004) Eur. Radiol. , vol.14 , Issue.12 , pp. 2212-2227
    • Schulz, T.1    Puccini, S.2    Schneider, J.P.3    Kahn, T.4
  • 2
    • 38949131465 scopus 로고    scopus 로고
    • MRI-guided interventions of the musculoskeletal system
    • Smith KA, Carrino J (2008) MRI-guided interventions of the musculoskeletal system. J Magn Reson Imaging 27(2):339-346
    • (2008) J. Magn. Reson. Imaging , vol.27 , Issue.2 , pp. 339-346
    • Smith, K.A.1    Carrino, J.2
  • 3
    • 45849133727 scopus 로고    scopus 로고
    • Real-time MR fluoroscopynavigated lumbar facet joint injections: Feasibility and technical properties
    • Fritz J, Clasen S, Boss A et al (2008) Real-time MR fluoroscopynavigated lumbar facet joint injections: feasibility and technical properties. Eur Radiol 18(7):1513-1518
    • (2008) Eur. Radiol. , vol.18 , Issue.7 , pp. 1513-1518
    • Fritz, J.1    Clasen, S.2    Boss, A.3
  • 5
    • 77953477624 scopus 로고    scopus 로고
    • Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: Feasibility and technical features
    • in press
    • Streitparth F, Walter T, Wonneberger U (2009) Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features. Eur Radiol (in press)
    • (2009) Eur. Radiol.
    • Streitparth, F.1    Walter, T.2    Wonneberger, U.3
  • 6
    • 35148822696 scopus 로고    scopus 로고
    • MR-guided pain therapy: Principles and clinical applications
    • Fritz J, Pereira PL (2007) MR-guided pain therapy: principles and clinical applications. Rofo 179(9):914-924
    • (2007) Rofo , vol.179 , Issue.9 , pp. 914-924
    • Fritz, J.1    Pereira, P.L.2
  • 7
    • 0031627276 scopus 로고    scopus 로고
    • MR guidance of laser disc decompression: Preliminary in vivo experience
    • Steiner P, Zweifel K, Botnar R et al (1998) MR guidance of laser disc decompression: preliminary in vivo experience. Eur Radiol 8(4):592-597
    • (1998) Eur. Radiol. , vol.8 , Issue.4 , pp. 592-597
    • Steiner, P.1    Zweifel, K.2    Botnar, R.3
  • 8
    • 67649124445 scopus 로고    scopus 로고
    • MR-guided laser ablation of osteoid osteoma in an open high-field system (1.0 T)
    • Streitparth F, Gebauer B, Melcher I et al (2009) MR-guided laser ablation of osteoid osteoma in an open high-field system (1.0 T). Cardiovasc Intervent Radiol 32(2):320-325
    • (2009) Cardiovasc. Intervent Radiol. , vol.32 , Issue.2 , pp. 320-325
    • Streitparth, F.1    Gebauer, B.2    Melcher, I.3
  • 9
    • 77953127530 scopus 로고    scopus 로고
    • Designation: F 2119-01-standard test method for evaluation of MR image artifacts from passive implants
    • American Society for Testing and Materials ASTM, West Conshohocken
    • American Society for Testing and Materials (ASTM) (2001) Designation: F 2119-01-standard test method for evaluation of MR image artifacts from passive implants. ATSM, West Conshohocken
    • (2001) ATSM
  • 10
    • 0029973623 scopus 로고    scopus 로고
    • Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 tesla
    • Frahm C, Gehl HB, Melchert UH, Weiss HD (1996) Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla. Cardiovasc Intervent Radiol 19(5):335-340
    • (1996) Cardiovasc. Intervent Radiol. , vol.19 , Issue.5 , pp. 335-340
    • Frahm, C.1    Gehl, H.B.2    Melchert, U.H.3    Weiss, H.D.4
  • 12
    • 0029895449 scopus 로고    scopus 로고
    • Comparing several groups using analysis of variance
    • Altman DG, Bland JM (1996) Comparing several groups using analysis of variance. Br Med J (Clin Res Ed) 312(7044):1472-1473
    • (1996) Br. Med. J. (Clin. Res. Ed.) , vol.312 , Issue.7044 , pp. 1472-1473
    • Altman, D.G.1    Bland, J.M.2
  • 13
    • 0033818660 scopus 로고    scopus 로고
    • Magnetic resonance temperature imaging for guidance of thermotherapy
    • Quesson B, de Zwart JA, Moonen CT (2000) Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 12(4):525-533
    • (2000) J. Magn. Reson. Imaging , vol.12 , Issue.4 , pp. 525-533
    • Quesson, B.1    De Zwart, J.A.2    Moonen, C.T.3
  • 15
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR (1996) Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR 166(6):1337-1345
    • (1996) AJR , vol.166 , Issue.6 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 17
    • 0031934809 scopus 로고    scopus 로고
    • Interventional MRI at highfield (1.5 T): Needle artifacts
    • Liu H, Martin AJ, Truwit CL (1998) Interventional MRI at highfield (1.5 T): needle artifacts. J Magn Reson Imaging 8(1):214-219
    • (1998) J. Magn. Reson. Imaging , vol.8 , Issue.1 , pp. 214-219
    • Liu, H.1    Martin, A.J.2    Truwit, C.L.3
  • 19
    • 12144291368 scopus 로고    scopus 로고
    • Numerical modeling of needle tip artifacts in MR gradient echo imaging
    • Muller-Bierl B, Graf H, Lauer U, Steidle G, Schick F (2004) Numerical modeling of needle tip artifacts in MR gradient echo imaging. Med Phys 31(3):579-587
    • (2004) Med. Phys. , vol.31 , Issue.3 , pp. 579-587
    • Muller-Bierl, B.1    Graf, H.2    Lauer, U.3    Steidle, G.4    Schick, F.5
  • 20
    • 12844259427 scopus 로고    scopus 로고
    • Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: Measurements and numerical simulations
    • Muller-Bierl B, Graf H, Steidle G, Schick F (2005) Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: measurements and numerical simulations. Med Phys 32(1):76-84
    • (2005) Med. Phys. , vol.32 , Issue.1 , pp. 76-84
    • Muller-Bierl, B.1    Graf, H.2    Steidle, G.3    Schick, F.4
  • 21
    • 0033961358 scopus 로고    scopus 로고
    • Comparison of artifacts produced from carbon fiber and titanium alloy needles at 1.5 T MR imaging
    • Reichenbach JR, Wurdinger S, Pfleiderer SO, Kaiser WA (2000) Comparison of artifacts produced from carbon fiber and titanium alloy needles at 1.5 T MR imaging. J Magn Reson Imaging 11(1):69-74
    • (2000) J. Magn. Reson. Imaging , vol.11 , Issue.1 , pp. 69-74
    • Reichenbach, J.R.1    Wurdinger, S.2    Pfleiderer, S.O.3    Kaiser, W.A.4
  • 22
    • 0025517450 scopus 로고
    • Effect of field strength on susceptibility artifacts in magnetic resonance imaging
    • Farahani K, Sinha U, Sinha S, Chiu LC, Lufkin RB (1990) Effect of field strength on susceptibility artifacts in magnetic resonance imaging. Comput Med Imaging Graph 14(6):409-413
    • (1990) Comput. Med. Imaging Graph , vol.14 , Issue.6 , pp. 409-413
    • Farahani, K.1    Sinha, U.2    Sinha, S.3    Chiu, L.C.4    Lufkin, R.B.5
  • 23
    • 68449085678 scopus 로고    scopus 로고
    • Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI
    • doi:10.1007/s00330-009-1393-7
    • Chopra SS, Rump J, Schmidt SC et al (2009) Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI. Eur Radiol. doi:10.1007/s00330-009-1393-7
    • (2009) Eur. Radiol.
    • Chopra, S.S.1    Rump, J.2    Schmidt, S.C.3
  • 24
    • 34447643261 scopus 로고    scopus 로고
    • Magnetic resonance-guided percutaneous laser disk decompression for lumbar disk herniation-relationship between clinical results and location of needle tip
    • Ishiwata Y, Takada H, Gondo G, Osano S, Hashimoto T, Yamamoto I (2007) Magnetic resonance-guided percutaneous laser disk decompression for lumbar disk herniation-relationship between clinical results and location of needle tip. Surg Neurol 68(2):159-163
    • (2007) Surg. Neurol. , vol.68 , Issue.2 , pp. 159-163
    • Ishiwata, Y.1    Takada, H.2    Gondo, G.3    Osano, S.4    Hashimoto, T.5    Yamamoto, I.6
  • 25
    • 0030836572 scopus 로고    scopus 로고
    • Real-time monitoring of laser diskectomies with a superconducting, openconfiguration MR system
    • Schoenenberger AW, Steiner P, Debatin JF et al (1997) Real-time monitoring of laser diskectomies with a superconducting, openconfiguration MR system. AJR 169(3):863-867
    • (1997) AJR , vol.169 , Issue.3 , pp. 863-867
    • Schoenenberger, A.W.1    Steiner, P.2    Debatin, J.F.3
  • 27
    • 0032939464 scopus 로고    scopus 로고
    • Comparison of four magnetic resonance methods for mapping small temperature changes
    • Wlodarczyk W, Hentschel M, Wust P et al (1999) Comparison of four magnetic resonance methods for mapping small temperature changes. Phys Med Biol 44(2):607-624
    • (1999) Phys. Med. Biol. , vol.44 , Issue.2 , pp. 607-624
    • Wlodarczyk, W.1    Hentschel, M.2    Wust, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.