메뉴 건너뛰기




Volumn 36, Issue 4, 1996, Pages 646-651

Biopsy needle susceptibility artifacts

Author keywords

biopsy needles; device visualization; interventional MRI; susceptibility artifacts

Indexed keywords

BIOPSY; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; VISIBILITY;

EID: 0029782987     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910360423     Document Type: Article
Times cited : (100)

References (17)
  • 1
    • 0023198477 scopus 로고
    • New needle for MR-guided aspiration cytology of the head and neck
    • R. B. Lufkin, L. Teresi, W. N. Hanafee, New needle for MR-guided aspiration cytology of the head and neck. AJR 149, 380-382 (1987).
    • (1987) AJR , vol.149 , pp. 380-382
    • Lufkin, R.B.1    Teresi, L.2    Hanafee, W.N.3
  • 5
    • 0006514756 scopus 로고    scopus 로고
    • Needle localization in MR guided therapy: Effect of field strength, sequence design, and magnetic field orientation
    • J. S. Lewin, J. L. Duerk, J. R. Haaga, Needle localization in MR guided therapy: effect of field strength, sequence design, and magnetic field orientation, in "Proc., SMR, 3rd Annual Meeting," p. 1155.
    • Proc., SMR, 3rd Annual Meeting , pp. 1155
    • Lewin, J.S.1    Duerk, J.L.2    Haaga, J.R.3
  • 6
    • 0006572338 scopus 로고    scopus 로고
    • Suitability of different MR-compatible needles and magnet designs for MR-guided punctures
    • H. B. Gehl, C. Frahm, U. H. Melchert, H. D. Weiss, Suitability of different MR-compatible needles and magnet designs for MR-guided punctures, in "Proc., SMR, 3rd Annual Meeting," p. 1156.
    • Proc., SMR, 3rd Annual Meeting , pp. 1156
    • Gehl, H.B.1    Frahm, C.2    Melchert, U.H.3    Weiss, H.D.4
  • 7
    • 0006602544 scopus 로고    scopus 로고
    • Study of new Titanium alloy needles for interventional MRI procedures
    • G. Lenz, C. Dewey, Study of new Titanium alloy needles for interventional MRI procedures, in "Proc., SMR, 3rd Annual Meeting," p. 1159.
    • Proc., SMR, 3rd Annual Meeting , pp. 1159
    • Lenz, G.1    Dewey, C.2
  • 10
    • 0027159714 scopus 로고
    • Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited
    • C. J. G. Bakker, R. Bhagwandien, M. A. Moorland, M. Fuderer, Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: the cylinder model revisited. Magn. Reson. Imaging 22, 539-548 (1993).
    • (1993) Magn. Reson. Imaging , vol.22 , pp. 539-548
    • Bakker, C.J.G.1    Bhagwandien, R.2    Moorland, M.A.3    Fuderer, M.4
  • 13
    • 0029184004 scopus 로고
    • Nonsusceptibility artifacts due to metallic objects in MR imaging
    • C. R. Camacho, D. B. Plewes, R. M. Henkelman, Nonsusceptibility artifacts due to metallic objects in MR imaging. J. Magn. Reson. Imaging 5, 75-88 (1995).
    • (1995) J. Magn. Reson. Imaging , vol.5 , pp. 75-88
    • Camacho, C.R.1    Plewes, D.B.2    Henkelman, R.M.3
  • 15
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • C. L. Dumoulin, S. P. Souza, R. D. Darrow, Real-time position monitoring of invasive devices using magnetic resonance. Magn. Reson. Med. 29, 411-415 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.