메뉴 건너뛰기




Volumn 8, Issue 1, 1998, Pages 214-219

Interventional MRI at high-field (1.5 T): Needle artifacts

Author keywords

Biopsy needles; Device visualization; Geometric Image distortion; Interventional MRI; Susceptibility artifact

Indexed keywords

TITANIUM;

EID: 0031934809     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880080136     Document Type: Article
Times cited : (52)

References (15)
  • 1
    • 0023006852 scopus 로고
    • MR-guided aspiration biopsy: Needle design and clinical trials
    • Mueller PR, Stark DD, Simeone JF, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986; 161: 605-609.
    • (1986) Radiology , vol.161 , pp. 605-609
    • Mueller, P.R.1    Stark, D.D.2    Simeone, J.F.3
  • 2
    • 0023198477 scopus 로고
    • New needle for MR-guided aspiration cytology of the head and neck
    • Lufkin RB, Teresi L, Hanafee WN. New needle for MR-guided aspiration cytology of the head and neck. Am J Roentgenol 1987; 149:380-382.
    • (1987) Am J Roentgenol , vol.149 , pp. 380-382
    • Lufkin, R.B.1    Teresi, L.2    Hanafee, W.N.3
  • 3
    • 0023726472 scopus 로고
    • A wire-sheath system for MR-guided biopsy and drainage: Laboratory studies and experience in 10 patients
    • van Sonnenberg E, Hajek P, Gylys-Morin V, et al. A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients. Am J Roentgenol 1988; 161:815-817.
    • (1988) Am J Roentgenol , vol.161 , pp. 815-817
    • Van Sonnenberg, E.1    Hajek, P.2    Gylys-Morin, V.3
  • 4
    • 0029392504 scopus 로고
    • Interventional MR imaging
    • Lufkin RB. Interventional MR imaging. Radiology 1995; 197: 16-18.
    • (1995) Radiology , vol.197 , pp. 16-18
    • Lufkin, R.B.1
  • 5
    • 0029114935 scopus 로고
    • Interventional MR-guided biopsy in an open-configuration MR imaging system
    • Silverman SG, Collick BD, Figueira MR, et al. Interventional MR-guided biopsy in an open-configuration MR imaging system. Radiology 1995; 197:175-181.
    • (1995) Radiology , vol.197 , pp. 175-181
    • Silverman, S.G.1    Collick, B.D.2    Figueira, M.R.3
  • 6
    • 0029005879 scopus 로고
    • Superconducting open configuration MRI system for image-guided therapy
    • Schenck JF, Jolesz FA, Roemer PB, et al. Superconducting open configuration MRI system for image-guided therapy. Radiology 1995; 195:805-814.
    • (1995) Radiology , vol.195 , pp. 805-814
    • Schenck, J.F.1    Jolesz, F.A.2    Roemer, P.B.3
  • 13
    • 0006555081 scopus 로고
    • Artifacts of MR-compatible biopsy needles: Optimization of pulse sequences, dependence on MR-parameters, comparison of different products
    • Nice: Society of Magnetic Resonance
    • Faber SC, Stehling MK, Reiser M. Artifacts of MR-compatible biopsy needles: optimization of pulse sequences, dependence on MR-parameters, comparison of different products. In: Proceedings of the 3rd annual scientific meeting of the Society of Magnetic Resonance. Nice: Society of Magnetic Resonance, 1995; 1741.
    • (1995) Proceedings of the 3rd Annual Scientific Meeting of the Society of Magnetic Resonance , pp. 1741
    • Faber, S.C.1    Stehling, M.K.2    Reiser, M.3
  • 15
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive device using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive device using magnetic resonance. Magn Reson Med 1993; 29:411-415.
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.