메뉴 건너뛰기




Volumn 21, Issue 2, 2010, Pages 198-208

Evolution of bearing surfaces in total hip arthroplasty: A review

Author keywords

Bearing surfaces; Evolution; Osteolysis; Total hip arthroplasty; Tribology

Indexed keywords

METAL; POLYETHYLENE;

EID: 77952261764     PISSN: 19407041     EISSN: 19417551     Source Type: Journal    
DOI: 10.1097/BCO.0b013e3181c2bab8     Document Type: Review
Times cited : (4)

References (171)
  • 1
    • 0037485549 scopus 로고    scopus 로고
    • The Norwegian registry of joint prostheses-15 beneficial years for both the patients and the health care
    • Furnes O, Havelin LI, Espehaug B, et al. The Norwegian registry of joint prostheses-15 beneficial years for both the patients and the health care. Tidsskr Nor Laegeforen. 2003; 123: 1367-1369.
    • (2003) Tidsskr Nor Laegeforen , vol.123 , pp. 1367-1369
    • Furnes, O.1    Havelin, L.I.2    Espehaug, B.3
  • 3
    • 52449102949 scopus 로고    scopus 로고
    • What patient and surgical factors contribute to implant wear and osteolysis in total joint arthroplasty?
    • Tsao AK, Jones LC, Lewallen DG. What patient and surgical factors contribute to implant wear and osteolysis in total joint arthroplasty? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S7-S13.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • Tsao, A.K.1    Jones, L.C.2    Lewallen, D.G.3
  • 4
    • 0033813545 scopus 로고    scopus 로고
    • Kinematic analysis of total knee prosthesis designed for Asian population
    • Low FH, Khoo LP, Chua CK, et al. Kinematic analysis of total knee prosthesis designed for Asian population. Crit Rev Biomed Eng. 2000; 28: 33-40.
    • (2000) Crit. Rev. Biomed Eng , vol.28 , pp. 33-40
    • Low, F.H.1    Khoo, L.P.2    Chua, C.K.3
  • 5
    • 8644226074 scopus 로고    scopus 로고
    • Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements
    • Fehring TK, Murphy JA, Hayes TD, et al. Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements. Clin Orthop Relat Res. 2004; 428: 40-50.
    • (2004) Clin. Orthop. Relat. Res. , vol.428 , pp. 40-50
    • Fehring, T.K.1    Murphy, J.A.2    Hayes, T.D.3
  • 6
    • 4644334557 scopus 로고    scopus 로고
    • Total knee arthroplasty in obese patients: A comparison with a matched control group
    • Foran JR, Mont MA, Rajadhyaksha AD, et al. Total knee arthroplasty in obese patients: a comparison with a matched control group. J Arthroplasty. 2004; 19: 817-824.
    • (2004) J. Arthroplasty , vol.19 , pp. 817-824
    • Foran, J.R.1    Mont, M.A.2    Rajadhyaksha, A.D.3
  • 7
    • 10444285036 scopus 로고    scopus 로고
    • Computational wear prediction of a total knee replacement from in vivo kinematics
    • Fregly BJ, Sawyer WG, Harman MK, et al. Computational wear prediction of a total knee replacement from in vivo kinematics. J Biomech. 2005; 38: 305-314.
    • (2005) J. Biomech , vol.38 , pp. 305-314
    • Fregly, B.J.1    Sawyer, W.G.2    Harman, M.K.3
  • 9
    • 26444509444 scopus 로고    scopus 로고
    • Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners
    • Birman MV, Noble PC, Conditt MA, et al. Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners. J Arthroplasty. 2005; 20 (7 suppl 3) : 87-92.
    • (2005) J. Arthroplasty , vol.20 , Issue.3-7 SUPPL. , pp. 87-92
    • Birman, M.V.1    Noble, P.C.2    Conditt, M.A.3
  • 10
    • 28544447733 scopus 로고    scopus 로고
    • Osteolysis after total knee arthroplasty: Influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively
    • Collier MB, Engh CA Jr, McAuley JP, et al. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Joint Surg. 2005; 87: 2702-2708.
    • (2005) J. Bone Joint Surg. , vol.87 , pp. 2702-2708
    • Collier, M.B.1    Engh Jr., C.A.2    McAuley, J.P.3
  • 11
    • 0027954306 scopus 로고
    • Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
    • Feng EL, Stulberg SD, Wixson RL. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop Relat Res. 1994; 299: 60-71.
    • (1994) Clin. Orthop. Relat. Res. , vol.299 , pp. 60-71
    • Feng, E.L.1    Stulberg, S.D.2    Wixson, R.L.3
  • 12
    • 34250223372 scopus 로고    scopus 로고
    • Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
    • Collier MB, Engh CA Jr, McAuley JP, et al. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg. 2007; 89: 1306-1314.
    • (2007) J. Bone Joint Surg. , vol.89 , pp. 1306-1314
    • Collier, M.B.1    Engh Jr., C.A.2    McAuley, J.P.3
  • 13
    • 0027972449 scopus 로고
    • Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
    • Wasielewski RC, Galante JO, Leighty RM, et al. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994; 299: 31-43.
    • (1994) Clin. Orthop. Relat. Res. , vol.299 , pp. 31-43
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.M.3
  • 14
    • 2642518202 scopus 로고    scopus 로고
    • NIH Consensus Statement on total knee replacement December 8-10, 2003
    • Rankin EA, Alarcon GS, Chang RW, et al. NIH Consensus Statement on total knee replacement December 8-10, 2003. J Bone Joint Surg. 2004; 86-A: 1328-1335.
    • (2004) J. Bone Joint Surg. , vol.86 A , pp. 1328-1335
    • Rankin, E.A.1    Alarcon, G.S.2    Chang, R.W.3
  • 15
    • 0035530168 scopus 로고    scopus 로고
    • Improving bearing surfaces of artificial joints
    • Willmann G. Improving bearing surfaces of artificial joints. Advanced Engineering Materials. 2001; 3: 135-141 (Pubitemid 33405693)
    • (2001) Advanced Engineering Materials , vol.3 , Issue.3 , pp. 135-141
    • Willmann, G.1
  • 16
    • 0942298191 scopus 로고    scopus 로고
    • Biologic and tribologic considerations of alternative bearing surfaces
    • Campbell P, Shen FW, McKellop H. Biologic and tribologic considerations of alternative bearing surfaces. Clin Orthop Relat Res. 2004; 418: 98-111.
    • (2004) Clin. Orthop. Relat. Res. , vol.418 , pp. 98-111
    • Campbell, P.1    Shen, F.W.2    McKellop, H.3
  • 17
    • 0038801204 scopus 로고    scopus 로고
    • Bearing surface options for total hip replacement in young patients
    • Heisel CS, Schmalzried TP. Bearing surface options for total hip replacement in young patients. J Bone Joint Surg. 2003; 85: 1366-1379.
    • (2003) J. Bone Joint Surg. , vol.85 , pp. 1366-1379
    • Heisel, C.S.1    Schmalzried, T.P.2
  • 18
    • 9644295676 scopus 로고    scopus 로고
    • How I choose a bearing surface for my patients
    • Schmalzried TP. How I choose a bearing surface for my patients. J Arthroplasty. 2004; 19 (8 suppl 3) : 50-53.
    • (2004) J. Arthroplasty , vol.19 , Issue.3-8 SUPPL. , pp. 50-53
    • Schmalzried, T.P.1
  • 19
    • 50549156477 scopus 로고
    • Arthroplasty of the hip. A new operation
    • Charnley J. Arthroplasty of the hip. A new operation. Lancet. 1961; 1: 1129-1132.
    • (1961) Lancet , vol.1 , pp. 1129-1132
    • Charnley, J.1
  • 21
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert HG. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977; 11: 157-164.
    • (1977) J. Biomed Mater Res. , vol.11 , pp. 157-164
    • Willert, H.G.1
  • 22
    • 52449108299 scopus 로고    scopus 로고
    • How prevalent are implant wear and osteolysis, and how has the scope of osteolysis changed since 2000?
    • Marshall A, Ries MD, Paprosky W. How prevalent are implant wear and osteolysis, and how has the scope of osteolysis changed since 2000? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S1-S6.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • Marshall, A.1    Ries, M.D.2    Paprosky, W.3
  • 23
    • 52449106712 scopus 로고    scopus 로고
    • How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement?
    • Crowninshield RD, Muratoglu OK. How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S80-S85.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • Crowninshield, R.D.1    Muratoglu, O.K.2
  • 24
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, et al. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 1999; 20: 1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3
  • 25
    • 11844261258 scopus 로고    scopus 로고
    • A review of current cross-linked polyethylenes used in total joint arthroplasty
    • Harris WH, Muratoglu OK. A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res. 2005; 430: 46-52.
    • (2005) Clin. Orthop. Relat. Res. , vol.430 , pp. 46-52
    • Harris, W.H.1    Muratoglu, O.K.2
  • 26
    • 0033178826 scopus 로고    scopus 로고
    • Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
    • Muratoglu OK, Bragdon CR, O'Connor DO, et al. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials. 1999; 20: 1463-1470.
    • (1999) Biomaterials , vol.20 , pp. 1463-1470
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3
  • 27
    • 35448982702 scopus 로고    scopus 로고
    • Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups
    • Currier BH, Currier JH, Mayor MB, et al. Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups. J Bone Joint Surg. 2007; 89: 2023-2029.
    • (2007) J. Bone Joint Surg. , vol.89 , pp. 2023-2029
    • Currier, B.H.1    Currier, J.H.2    Mayor, M.B.3
  • 28
    • 0033637708 scopus 로고    scopus 로고
    • Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study
    • McKellop H, Shen FW, Lu B, et al. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg. 2000; 82: 1708-1725.
    • (2000) J. Bone Joint Surg. , vol.82 , pp. 1708-1725
    • McKellop, H.1    Shen, F.W.2    Lu, B.3
  • 29
    • 34547604963 scopus 로고    scopus 로고
    • In vivo oxidation of gamma-barrier-sterilized ultra-high-molecular-weight polyethylene bearings
    • Currier BH, Currier JH, Mayor MB, et al. In vivo oxidation of gamma-barrier-sterilized ultra-high-molecular-weight polyethylene bearings. J Arthroplasty. 2007; 22: 721-731.
    • (2007) J. Arthroplasty , vol.22 , pp. 721-731
    • Currier, B.H.1    Currier, J.H.2    Mayor, M.B.3
  • 30
    • 0142147210 scopus 로고    scopus 로고
    • Increase in early polyethylene wear after sterilization with ethylene oxide: Radiostereometric analyses of 201 total hips
    • Digas G, Thanner J, Nivbrant B, et al. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003; 74: 531-541.
    • (2003) Acta Orthop Scand. , vol.74 , pp. 531-541
    • Digas, G.1    Thanner, J.2    Nivbrant, B.3
  • 31
    • 33645395712 scopus 로고    scopus 로고
    • Behavior of Hylamer polyethylene in hip arthroplasty: Comparison of two gamma sterilization techniques
    • Stea S, Antonietti B, Baruffaldi F, et al. Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques. Int Orthop. 2006; 30: 35-38.
    • (2006) Int. Orthop. , vol.30 , pp. 35-38
    • Stea, S.1    Antonietti, B.2    Baruffaldi, F.3
  • 32
    • 0942263536 scopus 로고    scopus 로고
    • The effects of crosslinking on the fracture and fatigue properties of UHMWPE acetabular cups
    • Walsh HA, Furman BD, Li S. The effects of crosslinking on the fracture and fatigue properties of UHMWPE acetabular cups. Trans Soc Biomater. 1999; 22: 592.
    • (1999) Trans Soc. Biomater , vol.22 , pp. 592
    • Walsh, H.A.1    Furman, B.D.2    Li, S.3
  • 33
    • 0001129670 scopus 로고    scopus 로고
    • An independent evaluation of the mechanical, chemical, and fracture properties of UHMWPE cross linked by 34 different conditions
    • Gillis AM, Schmieg JJ, Bhattacharya S, et al. An independent evaluation of the mechanical, chemical, and fracture properties of UHMWPE cross linked by 34 different conditions. Trans Orthop Res Soc. 1999; 24: 908.
    • (1999) Trans Orthop Res. Soc. , vol.24 , pp. 908
    • Gillis, A.M.1    Schmieg, J.J.2    Bhattacharya, S.3
  • 34
    • 0035230836 scopus 로고    scopus 로고
    • Bearing surfaces in total hip replacements: State of the art and future developments
    • McKellop HA. Bearing surfaces in total hip replacements: state of the art and future developments. Instr Course Lect. 2001; 50: 165-179.
    • (2001) Instr Course Lect , vol.50 , pp. 165-179
    • McKellop, H.A.1
  • 35
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
    • Muratoglu OK, Bragdon CR, O'Connor DO, et al. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 2001; 16: 149-160.
    • (2001) J. Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3
  • 36
    • 0032804049 scopus 로고    scopus 로고
    • Wear of gammacrosslinked polyethylene acetabular cups against roughened femoral balls
    • McKellop H, Shen FW, DiMaio W, et al. Wear of gammacrosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop Relat Res. 1999; 369: 73-82.
    • (1999) Clin. Orthop. Relat. Res. , vol.369 , pp. 73-82
    • McKellop, H.1    Shen, F.W.2    DiMaio, W.3
  • 37
    • 0033644172 scopus 로고    scopus 로고
    • The bearing surface in total hip arthroplasty: Evolution or revolution
    • Sharkey PF, Hozack WJ, Dorr LD, et al. The bearing surface in total hip arthroplasty: evolution or revolution. Instr Course Lect. 2000; 49: 41-56.
    • (2000) Instr Course Lect , vol.49 , pp. 41-56
    • Sharkey, P.F.1    Hozack, W.J.2    Dorr, L.D.3
  • 38
    • 35349019671 scopus 로고    scopus 로고
    • Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
    • Tower SS, Currier JH, Currier BH, et al. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg. 2007; 89: 2212-2217.
    • (2007) J. Bone Joint Surg. , vol.89 , pp. 2212-2217
    • Tower, S.S.1    Currier, J.H.2    Currier, B.H.3
  • 39
    • 14244254462 scopus 로고    scopus 로고
    • Molecular chain stretch is a multiaxial failure criterion for conventional and highly crosslinked UHMWPE
    • Bergstrom JS, Rimnac CM, Kurtz SM. Molecular chain stretch is a multiaxial failure criterion for conventional and highly crosslinked UHMWPE. J Orthop Res. 2005; 23: 367-375.
    • (2005) J. Orthop. Res. , vol.23 , pp. 367-375
    • Bergstrom, J.S.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 40
    • 11144265302 scopus 로고    scopus 로고
    • Notch strengthening and hardening behavior of conventional and highly crosslinked UHMWPE under applied tensile loading
    • Sobieraj MC, Kurtz SM, Rimnac CM. Notch strengthening and hardening behavior of conventional and highly crosslinked UHMWPE under applied tensile loading. Biomaterials. 2005; 26: 3411-3426.
    • (2005) Biomaterials , vol.26 , pp. 3411-3426
    • Sobieraj, M.C.1    Kurtz, S.M.2    Rimnac, C.M.3
  • 41
    • 52049094329 scopus 로고    scopus 로고
    • Highly cross-linked ultrahigh molecular weight polyethylene with improved fatigue resistance for total joint arthroplasty: Recipient of the 2006 Hap Paul Award
    • Oral E, Malhi AS, Wannomae KK, et al. Highly cross-linked ultrahigh molecular weight polyethylene with improved fatigue resistance for total joint arthroplasty: recipient of the 2006 Hap Paul Award. J Arthroplasty. 2008; 23: 1037-1044.
    • (2008) J. Arthroplasty , vol.23 , pp. 1037-1044
    • Oral, E.1    Malhi, A.S.2    Wannomae, K.K.3
  • 42
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H, Shen FW, Lu B, et al. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999; 17: 157-167.
    • (1999) J. Orthop. Res. , vol.17 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3
  • 44
    • 44449129970 scopus 로고    scopus 로고
    • A highly crosslinked UHMWPE for CR and PS total knee arthroplasties
    • Wang A, Yau SS, Essner A, et al. A highly crosslinked UHMWPE for CR and PS total knee arthroplasties. J Arthroplasty. 2008; 23: 559-566.
    • (2008) J. Arthroplasty , vol.23 , pp. 559-566
    • Wang, A.1    Yau, S.S.2    Essner, A.3
  • 45
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg. 1997; 79: 1635-1641.
    • (1997) J. Bone Joint Surg. , vol.79 , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 46
    • 22544437873 scopus 로고    scopus 로고
    • Characterization of irradiated blends of alpha-tocopherol and UHMWPE
    • Oral E, Greenbaum ES, Malhi AS, et al. Characterization of irradiated blends of alpha-tocopherol and UHMWPE. Biomaterials. 2005; 26: 6657-6663.
    • (2005) Biomaterials , vol.26 , pp. 6657-6663
    • Oral, E.1    Greenbaum, E.S.2    Malhi, A.S.3
  • 47
    • 34948901872 scopus 로고    scopus 로고
    • Diffusion of vitamin E in ultra-high molecular weight polyethylene
    • Oral E, Wannomae KK, Rowell SL, et al. Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials. 2007; 28: 5225-5237.
    • (2007) Biomaterials , vol.28 , pp. 5225-5237
    • Oral, E.1    Wannomae, K.K.2    Rowell, S.L.3
  • 48
    • 33745009957 scopus 로고    scopus 로고
    • Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E
    • Oral E, Christensen SD, Malhi AS, et al. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthroplasty. 2006; 21: 580-591.
    • (2006) J. Arthroplasty , vol.21 , pp. 580-591
    • Oral, E.1    Christensen, S.D.2    Malhi, A.S.3
  • 49
    • 20444423321 scopus 로고    scopus 로고
    • The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance
    • Shibata N, Tomita N. The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance. Biomaterials. 2005; 26: 5755-5762.
    • (2005) Biomaterials , vol.26 , pp. 5755-5762
    • Shibata, N.1    Tomita, N.2
  • 50
    • 2342495274 scopus 로고    scopus 로고
    • Alpha-tocopheroldoped irradiated UHMWPE for high fatigue resistance and low wear
    • Oral E, Wannomae KK, Hawkins N, et al. Alpha-tocopheroldoped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials. 2004; 25: 5515-5522.
    • (2004) Biomaterials , vol.25 , pp. 5515-5522
    • Oral, E.1    Wannomae, K.K.2    Hawkins, N.3
  • 51
    • 33645219347 scopus 로고    scopus 로고
    • Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives
    • Isaac GH, Thompson J, Williams S, et al. Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives. Proc Inst Mech Eng [H]. 2006; 220: 119-133.
    • (2006) Proc. Inst. Mech. Eng. [H] , vol.220 , pp. 119-133
    • Isaac, G.H.1    Thompson, J.2    Williams, S.3
  • 53
    • 0036325167 scopus 로고    scopus 로고
    • Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head
    • Norton MR, Yarlagadda R, Anderson GH. Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head. J Bone Joint Surg. 2002; 84: 631-635.
    • (2002) J. Bone Joint Surg. , vol.84 , pp. 631-635
    • Norton, M.R.1    Yarlagadda, R.2    Anderson, G.H.3
  • 54
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999; 20: 1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 55
    • 0033779502 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic total hip systems in the United States: Early results
    • Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000; 379: 41-47.
    • (2000) Clin. Orthop. Relat. Res. , vol.379 , pp. 41-47
    • Garino, J.P.1
  • 56
    • 0033775261 scopus 로고    scopus 로고
    • Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    • Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res. 2000; 379: 34-40.
    • (2000) Clin. Orthop. Relat. Res. , vol.379 , pp. 34-40
    • Clarke, I.C.1    Gustafson, A.2
  • 57
    • 61449099441 scopus 로고    scopus 로고
    • Ceramic materials as bearing surfaces for total hip arthroplasty
    • D'Antonio JA, Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg. 2009; 17: 63-68.
    • (2009) J. Am. Acad. Orthop. Surg. , vol.17 , pp. 63-68
    • D'Antonio, J.A.1    Sutton, K.2
  • 58
    • 0242606961 scopus 로고    scopus 로고
    • Reduced wear with oxidized zirconium femoral heads
    • Good V, Ries M, Barrack RL, et al. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg. 2003; 85 (suppl 4) : 105-110.
    • (2003) J. Bone Joint Surg. , vol.85 , Issue.4 SUPPL. , pp. 105-110
    • Good, V.1    Ries, M.2    Barrack, R.L.3
  • 59
    • 0035176116 scopus 로고    scopus 로고
    • Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twentyone-year results
    • Urban JA, Garvin KL, Boese CK, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twentyone-year results. J Bone Joint Surg. 2001; 83: 1688-1694.
    • (2001) J. Bone Joint Surg. , vol.83 , pp. 1688-1694
    • Urban, J.A.1    Garvin, K.L.2    Boese, C.K.3
  • 60
    • 68949204404 scopus 로고    scopus 로고
    • Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty
    • February 4, epub ahead of print
    • Lewis PM, Al-Belooshi A, Olsen M, et al. Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty. J Arthroplasty. February 4, 2009 [epub ahead of print].
    • (2009) J. Arthroplasty
    • Lewis, P.M.1    Al-Belooshi, A.2    Olsen, M.3
  • 61
    • 0014853440 scopus 로고
    • Development of total prosthetic replacement of the hip
    • McKee GK. Development of total prosthetic replacement of the hip. Clin Orthop Relat Res. 1970; 72: 85-103.
    • (1970) Clin. Orthop. Relat. Res. , vol.72 , pp. 85-103
    • McKee, G.K.1
  • 62
    • 0042235809 scopus 로고    scopus 로고
    • Alternative materials to improve total hip replacement tribology
    • Santavirta S, Bohler M, Harris WH, et al. Alternative materials to improve total hip replacement tribology. Acta Orthop Scand. 2003; 74: 380-388.
    • (2003) Acta Orthop Scand. , vol.74 , pp. 380-388
    • Santavirta, S.1    Bohler, M.2    Harris, W.H.3
  • 63
    • 0029882821 scopus 로고    scopus 로고
    • Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
    • Schmalzried TP, Peters PC, Maurer BT, et al. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. J Arthroplasty. 1996; 11: 322-331.
    • (1996) J. Arthroplasty , vol.11 , pp. 322-331
    • Schmalzried, T.P.1    Peters, P.C.2    Maurer, B.T.3
  • 64
    • 0029813457 scopus 로고    scopus 로고
    • Cobalt chromium molybdenum metal combination for modular hip prostheses
    • Schmidt M, Weber H, Schon R. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthop Relat Res. 1996; 329: S35-S47.
    • (1996) Clin. Orthop. Relat. Res. , vol.329
    • Schmidt, M.1    Weber, H.2    Schon, R.3
  • 67
    • 0020623582 scopus 로고
    • Frictional torque in surface and conventional hip replacement
    • Ma SM, Kabo JM, Amstutz HC. Frictional torque in surface and conventional hip replacement. J Bone Joint Surg. 1983; 65: 366-370.
    • (1983) J. Bone Joint Surg. , vol.65 , pp. 366-370
    • Ma, S.M.1    Kabo, J.M.2    Amstutz, H.C.3
  • 68
    • 0017413769 scopus 로고
    • Factors affecting the mechanical stability of the cemented acetabular component in total hip replacement
    • Volz RG, Wilson RJ. Factors affecting the mechanical stability of the cemented acetabular component in total hip replacement. J Bone Joint Surg. 1977; 59: 501-504.
    • (1977) J. Bone Joint Surg. , vol.59 , pp. 501-504
    • Volz, R.G.1    Wilson, R.J.2
  • 69
    • 0029809718 scopus 로고    scopus 로고
    • Metal on metal bearings in hip arthroplasty
    • Amstutz HC, Grigoris P. Metal on metal bearings in hip arthroplasty. Clin Orthop Relat Res. 1996; 329 (suppl) : S11-S34.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Amstutz, H.C.1    Grigoris, P.2
  • 70
    • 0029790388 scopus 로고    scopus 로고
    • Twenty-year results of McKee-Farrar versus Charnley prosthesis
    • Jacobsson SA, Djerf K, Wahlstrom O. Twenty-year results of McKee-Farrar versus Charnley prosthesis. Clin Orthop Relat Res. 1996; 329 (suppl) : S60-S68.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Jacobsson, S.A.1    Djerf, K.2    Wahlstrom, O.3
  • 71
    • 0025349263 scopus 로고
    • A comparative study between McKee-Farrar and Charnley arthroplasty with longterm follow-up periods
    • Jacobsson SA, Djerf K, Wahlstrom O. A comparative study between McKee-Farrar and Charnley arthroplasty with longterm follow-up periods. J Arthroplasty. 1990; 5: 9-14.
    • (1990) J. Arthroplasty , vol.5 , pp. 9-14
    • Jacobsson, S.A.1    Djerf, K.2    Wahlstrom, O.3
  • 72
    • 0029813220 scopus 로고    scopus 로고
    • Factors correlating with long term survival of McKee-Farrar total hip prostheses
    • Schmalzried TP, Szuszczewicz ES, Akizuki KH, et al. Factors correlating with long term survival of McKee-Farrar total hip prostheses. Clin Orthop Relat Res. 1996; 329 (suppl) : S48-S59.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Schmalzried, T.P.1    Szuszczewicz, E.S.2    Akizuki, K.H.3
  • 73
    • 0032932612 scopus 로고    scopus 로고
    • Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement
    • Zahiri CA, Schmalzried TP, Ebramzadeh E, et al. Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement. J Arthroplasty. 1999; 14: 326-332.
    • (1999) J. Arthroplasty , vol.14 , pp. 326-332
    • Zahiri, C.A.1    Schmalzried, T.P.2    Ebramzadeh, E.3
  • 74
  • 75
    • 0023617819 scopus 로고
    • Long-term results and survivorship of the McKee-Farrar total hip prosthesis
    • Visuri T. Long-term results and survivorship of the McKee-Farrar total hip prosthesis. Arch Orthop Trauma Surg. 1987; 106: 368-374.
    • (1987) Arch. Orthop. Trauma Surg. , vol.106 , pp. 368-374
    • Visuri, T.1
  • 76
    • 0025113253 scopus 로고
    • Prognosis of total hip replacement. A Swedish multicenter study of 4664 revisions
    • Ahnfelt L, Herberts P, Malchau H, et al. Prognosis of total hip replacement. A Swedish multicenter study of 4664 revisions. Acta Orthop Scand Suppl. 1990; 238: 1-26.
    • (1990) Acta Orthop Scand. Suppl. , vol.238 , pp. 1-26
    • Ahnfelt, L.1    Herberts, P.2    Malchau, H.3
  • 77
    • 0031049064 scopus 로고    scopus 로고
    • Metal-on-metal CoCrMo McKee-Farrar total hip arthroplasty: Characteristics from a long-term follow-up study
    • Higuchi F, Inoue A, Semlitsch M. Metal-on-metal CoCrMo McKee-Farrar total hip arthroplasty: characteristics from a long-term follow-up study. Arch Orthop Trauma Surg. 1997; 116: 121-124.
    • (1997) Arch. Orthop. Trauma Surg. , vol.116 , pp. 121-124
    • Higuchi, F.1    Inoue, A.2    Semlitsch, M.3
  • 79
    • 0029788857 scopus 로고    scopus 로고
    • Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty
    • Wagner MWH. Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty. Clin Orthop Relat Res. 1996; 329 (suppl) : S78-S88.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Wagner, M.W.H.1
  • 80
    • 0030210397 scopus 로고    scopus 로고
    • Comparison of alloys and designs in a hip simulator study of metal on metal implants
    • Medley JB, Chan FW, Krygier JJ, et al. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clin Orthop Relat Res. 1996; 329 (suppl) : S148-S159.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Medley, J.B.1    Chan, F.W.2    Krygier, J.J.3
  • 81
    • 0030454623 scopus 로고    scopus 로고
    • Engineering issues and wear performance of metal on metal hip implants
    • Chan FW, Bobyn JD, Medley JB, et al. Engineering issues and wear performance of metal on metal hip implants. Clin Orthop Relat Res. 1996; 333: 96-107.
    • (1996) Clin. Orthop. Relat. Res. , vol.333 , pp. 96-107
    • Chan, F.W.1    Bobyn, J.D.2    Medley, J.B.3
  • 82
    • 0005226043 scopus 로고    scopus 로고
    • The effect of diametral clearance on wear between head and cup for metal on metal articulations
    • Farrar RSM. The effect of diametral clearance on wear between head and cup for metal on metal articulations. Trans Orthop Res Soc. 1997; 22: 71.
    • (1997) Trans Orthop Res. Soc. , vol.22 , pp. 71
    • Farrar, R.S.M.1
  • 83
    • 0029831455 scopus 로고    scopus 로고
    • In vivo wear of three types of metal on metal hip prostheses during two decades of use
    • McKellop H, Park SH, Chiesa R, et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthop Relat Res. 1996; 329 (suppl) : S128-S140.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • McKellop, H.1    Park, S.H.2    Chiesa, R.3
  • 84
    • 0035184881 scopus 로고    scopus 로고
    • The wear pattern in metal-on-metal hip prostheses
    • Anissian HL, Stark A, Good V, et al. The wear pattern in metal-on-metal hip prostheses. J Biomed Mater Res. 2001; 58: 673-678.
    • (2001) J. Biomed Mater Res. , vol.58 , pp. 673-678
    • Anissian, H.L.1    Stark, A.2    Good, V.3
  • 85
    • 0033378263 scopus 로고    scopus 로고
    • Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    • Anissian HL, Stark A, Gustafson A, et al. Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand. 1999; 70: 578-582.
    • (1999) Acta Orthop Scand. , vol.70 , pp. 578-582
    • Anissian, H.L.1    Stark, A.2    Gustafson, A.3
  • 86
    • 0033641059 scopus 로고    scopus 로고
    • Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
    • Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng [H]. 2000; 214: 331-347.
    • (2000) Proc. Inst. Mech. Eng. [H] , vol.214 , pp. 331-347
    • Clarke, I.C.1    Good, V.2    Williams, P.3
  • 87
    • 0033630259 scopus 로고    scopus 로고
    • A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    • Goldsmith AA, Dowson D, Isaac GH, et al. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proc Inst Mech Eng [H]. 2000; 214: 39-47.
    • (2000) Proc. Inst. Mech. Eng. [H] , vol.214 , pp. 39-47
    • Goldsmith, A.A.1    Dowson, D.2    Isaac, G.H.3
  • 88
    • 0035237584 scopus 로고    scopus 로고
    • In vitro comparison of the two hard-hard articulations for total hip replacements
    • Rieker C, Konrad R, Schon R. In vitro comparison of the two hard-hard articulations for total hip replacements. Proc Inst Mech Eng [H]. 2001; 215: 153-160.
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , pp. 153-160
    • Rieker, C.1    Konrad, R.2    Schon, R.3
  • 89
    • 0030339156 scopus 로고    scopus 로고
    • Metal-on-metal articulation for artificial hip joints: Laboratory study and clinical results
    • Streicher RM, Semlitsch M, Schon R, et al. Metal-on-metal articulation for artificial hip joints: laboratory study and clinical results. Proc Inst Mech Eng [H]. 1996; 210: 223-232.
    • (1996) Proc. Inst. Mech. Eng. [H] , vol.210 , pp. 223-232
    • Streicher, R.M.1    Semlitsch, M.2    Schon, R.3
  • 90
    • 0033819163 scopus 로고    scopus 로고
    • The effect of femoral component head size on posterior dislocation of the artificial hip joint
    • Bartz RL, Nobel PC, Kadakia NR, et al. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg. 2000; 82: 1300-1307.
    • (2000) J. Bone Joint Surg. , vol.82 , pp. 1300-1307
    • Bartz, R.L.1    Nobel, P.C.2    Kadakia, N.R.3
  • 91
    • 0036484326 scopus 로고    scopus 로고
    • Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement
    • Beaule PE, Schmalzried TP, Udomkiat P, et al. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg. 2002; 84: 256-263.
    • (2002) J. Bone Joint Surg. , vol.84 , pp. 256-263
    • Beaule, P.E.1    Schmalzried, T.P.2    Udomkiat, P.3
  • 92
    • 0021322281 scopus 로고
    • Systemic effects of biomaterials
    • Black J. Systemic effects of biomaterials. Biomaterials. 1984; 5: 11-18.
    • (1984) Biomaterials , vol.5 , pp. 11-18
    • Black, J.1
  • 93
    • 0031843319 scopus 로고    scopus 로고
    • Variation in cytokines induced by particles from different prosthetic materials
    • Haynes DR, Boyle SJ, Rogers SD, et al. Variation in cytokines induced by particles from different prosthetic materials. Clin Orthop Relat Res. 1998; 352: 223-230.
    • (1998) Clin. Orthop. Relat. Res. , vol.352 , pp. 223-230
    • Haynes, D.R.1    Boyle, S.J.2    Rogers, S.D.3
  • 94
    • 0029837640 scopus 로고    scopus 로고
    • Biologic effects of cobalt chrome in cell and animal models
    • Howie DW, Rogers SD, McGee MA, et al. Biologic effects of cobalt chrome in cell and animal models. Clin Orthop Relat Res. 1996; 329 (suppl) : S217-S232.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Howie, D.W.1    Rogers, S.D.2    McGee, M.A.3
  • 95
    • 0029360318 scopus 로고
    • Human monocyte response to particulate biomaterials generated in vivo and in vitro
    • Shanbhag AS, Jacobs JJ, Black J, et al. Human monocyte response to particulate biomaterials generated in vivo and in vitro. J Orthop Res. 1995; 13: 792-801.
    • (1995) J. Orthop. Res. , vol.13 , pp. 792-801
    • Shanbhag, A.S.1    Jacobs, J.J.2    Black, J.3
  • 96
    • 0028158570 scopus 로고
    • Macrophage/particle interactions: Effect of size, composition and surface area
    • Shanbhag AS, Jacobs JJ, Black J, et al. Macrophage/particle interactions: effect of size, composition and surface area. J Biomed Mater Res. 1994; 28: 81-90.
    • (1994) J. Biomed. Mater. Res. , vol.28 , pp. 81-90
    • Shanbhag, A.S.1    Jacobs, J.J.2    Black, J.3
  • 97
    • 0030667572 scopus 로고    scopus 로고
    • Modulation of the production of cytokines in titanium-stimulated human peripheral blood monocytes by pharmacological agents. The role of cAMP-mediated signaling mechanisms
    • Blaine TA, Pollice PF, Rosier RN, et al. Modulation of the production of cytokines in titanium-stimulated human peripheral blood monocytes by pharmacological agents. The role of cAMP-mediated signaling mechanisms. J Bone Joint Surg. 1997; 79: 1519-1528.
    • (1997) J. Bone Joint Surg. , vol.79 , pp. 1519-1528
    • Blaine, T.A.1    Pollice, P.F.2    Rosier, R.N.3
  • 98
    • 0031027419 scopus 로고    scopus 로고
    • Suppression of osteoblast function by titanium particles
    • Yao J, Cs-Szabo G, Jacobs JJ, et al. Suppression of osteoblast function by titanium particles. J Bone Joint Surg. 1997; 79: 107-112.
    • (1997) J. Bone Joint Surg. , vol.79 , pp. 107-112
    • Yao, J.1    Cs-Szabo, G.2    Jacobs, J.J.3
  • 99
    • 34247618193 scopus 로고    scopus 로고
    • Neo-capsule tissue reactions in metal-on-metal hip arthroplasty
    • Witzleb WC, Hanisch U, Kolar N, et al. Neo-capsule tissue reactions in metal-on-metal hip arthroplasty. Acta Orthop. 2007; 78: 211-220.
    • (2007) Acta Orthop. , vol.78 , pp. 211-220
    • Witzleb, W.C.1    Hanisch, U.2    Kolar, N.3
  • 100
    • 9444289847 scopus 로고    scopus 로고
    • Tissue reaction to metal on metal total hip prostheses
    • Doorn PF, Mirra JM, Campbell PA, et al. Tissue reaction to metal on metal total hip prostheses. Clin Orthop Relat Res. 1996; 329 (suppl) : S187-S205.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Doorn, P.F.1    Mirra, J.M.2    Campbell, P.A.3
  • 101
    • 0344629799 scopus 로고    scopus 로고
    • Metal degradation products: A cause for concern in metal-metal bearings?
    • Jacobs JJ, Hallab NJ, Skipor AK, et al. Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res. 2003; 417: 139-147.
    • (2003) Clin. Orthop. Relat. Res. , vol.417 , pp. 139-147
    • Jacobs, J.J.1    Hallab, N.J.2    Skipor, A.K.3
  • 102
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
    • Jacobs JJ, Skipor AK, Patterson LM, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg. 1998; 80: 1447-1458.
    • (1998) J. Bone Joint Surg. , vol.80 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, L.M.3
  • 103
    • 0021277244 scopus 로고
    • Trace element burdening of human tissues due to the corrosion of hip-joint prostheses made of cobalt-chromium alloys
    • Michel R, Hofmann J, Loer F, et al. Trace element burdening of human tissues due to the corrosion of hip-joint prostheses made of cobalt-chromium alloys. Arch Orthop Trauma Surg. 1984; 103: 85-95.
    • (1984) Arch. Orthop. Trauma Surg. , vol.103 , pp. 85-95
    • Michel, R.1    Hofmann, J.2    Loer, F.3
  • 104
    • 0024670459 scopus 로고
    • Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses
    • Sunderman FW Jr, Hopfer SM, Swift T, et al. Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses. J Orthop Res. 1989; 7: 307-315.
    • (1989) J. Orthop. Res. , vol.7 , pp. 307-315
    • Sunderman Jr., F.W.1    Hopfer, S.M.2    Swift, T.3
  • 105
    • 0015913178 scopus 로고
    • Concentration of wear products in hair, blood, and urine after total hip replacement
    • Coleman RF, Herrington J, Scales JT. Concentration of wear products in hair, blood, and urine after total hip replacement. Br Med J. 1973; 1: 527-529.
    • (1973) Br. Med. J. , vol.1 , pp. 527-529
    • Coleman, R.F.1    Herrington, J.2    Scales, J.T.3
  • 106
    • 0029817370 scopus 로고    scopus 로고
    • Cobalt and chromium concentrations in patients with metal on metal total hip replacements
    • Jacobs JJ, Skipor AK, Doorn PF, et al. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin Orthop Relat Res. 1996; 329 (suppl) : S256-S263.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Jacobs, J.J.1    Skipor, A.K.2    Doorn, P.F.3
  • 107
    • 0028845164 scopus 로고    scopus 로고
    • Local and distant products from modularity
    • Jacobs J, Urban R, Gilbert J. Local and distant products from modularity. Clin Orthop. 1997; 319: 94-105.
    • (1997) Clin. Orthop. , vol.319 , pp. 94-105
    • Jacobs, J.1    Urban, R.2    Gilbert, J.3
  • 108
    • 0030953811 scopus 로고    scopus 로고
    • Lymphoreticular dissemination of metal particles after primary joint replacements
    • Shea KG, Lundeen GA, Bloebaum RD, et al. Lymphoreticular dissemination of metal particles after primary joint replacements. Clin Orthop Relat Res. 1997; 338: 219-226.
    • (1997) Clin. Orthop. Relat. Res. , vol.338 , pp. 219-226
    • Shea, K.G.1    Lundeen, G.A.2    Bloebaum, R.D.3
  • 109
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban RM, Jacobs JJ, Tomlinson MJ, et al. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg. 2000; 82: 457-476.
    • (2000) J. Bone Joint Surg. , vol.82 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3
  • 111
    • 11844293972 scopus 로고    scopus 로고
    • Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
    • Willert HG, Buchhorn GH, Fayyazi A, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg. 2005; 87: 28-36.
    • (2005) J. Bone Joint Surg. , vol.87 , pp. 28-36
    • Willert, H.G.1    Buchhorn, G.H.2    Fayyazi, A.3
  • 112
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt chromium wear and corrosion products and biologic reactions
    • Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res. 1996; 329 (suppl) : S233-S243.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Merritt, K.1    Brown, S.A.2
  • 113
    • 0029809897 scopus 로고    scopus 로고
    • Metal on metal total hip replacement workshop consensus document
    • Amstutz HC, Campbell P, McKellop H, et al. Metal on metal total hip replacement workshop consensus document. Clin Orthop Relat Res. 1996; 329 (suppl) : S297-S303.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Amstutz, H.C.1    Campbell, P.2    McKellop, H.3
  • 115
    • 0031762034 scopus 로고    scopus 로고
    • Failure of total hip arthroplasty with a precoated prosthesis. 4-to 11-year results
    • Dowd JE, Cha CW, Trakru S, et al. Failure of total hip arthroplasty with a precoated prosthesis. 4-to 11-year results. Clin Orthop Relat Res. 1998; 355: 123-136.
    • (1998) Clin. Orthop. Relat. Res. , vol.355 , pp. 123-136
    • Dowd, J.E.1    Cha, C.W.2    Trakru, S.3
  • 116
    • 0015692132 scopus 로고
    • A comparative review of the McKee-Farrar and Charnley total hip prostheses
    • Bentley G, Duthie RB. A comparative review of the McKee-Farrar and Charnley total hip prostheses. Clin Orthop Relat Res. 1973; 95: 127-142.
    • (1973) Clin. Orthop. Relat. Res. , vol.95 , pp. 127-142
    • Bentley, G.1    Duthie, R.B.2
  • 117
    • 0016718479 scopus 로고
    • Incidence of metal sensitivity in patients with total joint replacements
    • Elves MW, Wilson JN, Scales JT, et al. Incidence of metal sensitivity in patients with total joint replacements. Br Med J. 1975; 4: 376-378.
    • (1975) Br. Med. J. , vol.4 , pp. 376-378
    • Elves, M.W.1    Wilson, J.N.2    Scales, J.T.3
  • 118
    • 0028533512 scopus 로고
    • Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements
    • Yang J, Merritt K. Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements. J Biomed Mater Res. 1994; 28: 1249-1258.
    • (1994) J. Biomed. Mater. Res. , vol.28 , pp. 1249-1258
    • Yang, J.1    Merritt, K.2
  • 121
    • 0024713659 scopus 로고
    • Elimination of nickel, cobalt, and chromium following repeated injections of high dose metal salts
    • Merritt K, Crowe TD, Brown SA. Elimination of nickel, cobalt, and chromium following repeated injections of high dose metal salts. J Biomed Mater Res. 1989; 23: 845-862.
    • (1989) J. Biomed. Mater. Res. , vol.23 , pp. 845-862
    • Merritt, K.1    Crowe, T.D.2    Brown, S.A.3
  • 122
    • 0034035755 scopus 로고    scopus 로고
    • A potential concern in total joint arthroplasty: Systemic dissemination of wear debris
    • Clark CR. A potential concern in total joint arthroplasty: systemic dissemination of wear debris. J Bone Joint Surg. 2000; 82: 455-456.
    • (2000) J. Bone Joint Surg. , vol.82 , pp. 455-456
    • Clark, C.R.1
  • 123
    • 0023028073 scopus 로고
    • Malignant neoplasms associated with orthopedic implant materials in rats
    • Memoli VA, Urban RM, Alroy J, et al. Malignant neoplasms associated with orthopedic implant materials in rats. J Orthop Res. 1986; 4: 346-355.
    • (1986) J. Orthop. Res. , vol.4 , pp. 346-355
    • Memoli, V.A.1    Urban, R.M.2    Alroy, J.3
  • 125
    • 0026808441 scopus 로고
    • Early sarcomatous degeneration near a cementless hip replacement. A case report and review
    • Jacobs JJ, Rosenbaum DH, Hay RM, et al. Early sarcomatous degeneration near a cementless hip replacement. A case report and review. J Bone Joint Surg. 1992; 74: 740-744.
    • (1992) J. Bone Joint Surg. , vol.74 , pp. 740-744
    • Jacobs, J.J.1    Rosenbaum, D.H.2    Hay, R.M.3
  • 127
    • 0029789979 scopus 로고    scopus 로고
    • Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty
    • Visuri T, Pukkala E, Paavolainen P, et al. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop Relat Res. 1996; 329 (suppl) : S280-S289.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Visuri, T.1    Pukkala, E.2    Paavolainen, P.3
  • 128
    • 0029837641 scopus 로고    scopus 로고
    • Development of hematopoietic cancers after implantation of total joint replacement
    • Gillespie WJ, Henry DA, O'Connell DL, et al. Development of hematopoietic cancers after implantation of total joint replacement. Clin Orthop Relat Res. 1996; 329 (suppl) : S290-S296.
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • Gillespie, W.J.1    Henry, D.A.2    O'Connell, D.L.3
  • 129
    • 0032960479 scopus 로고    scopus 로고
    • Cancer incidence in Finnish hip replacement patients from 1980 to 1995: A nationwide cohort study involving 31,651 patients
    • DOI 10.1016/S0883-5403(99)90051-7
    • Paavolainen P, Pukkala E, Pulkkinen P, et al. Cancer incidence in Finnish hip replacement patients from 1980 to 1995:a nationwide cohort study involving 31, 651 patients. J Arthroplasty. 1999; 14: 272-280. (Pubitemid 29172241)
    • (1999) Journal of Arthroplasty , vol.14 , Issue.3 , pp. 272-280
    • Paavolainen, P.1    Pukkala, E.2    Pulkkinen, P.3    Visuri, T.4
  • 130
    • 0028899634 scopus 로고
    • Cancer risk after hip replacement with metal implants: A population-based cohort study in Sweden
    • Nyren O, McLaughlin JK, Gridley G, et al. Cancer risk after hip replacement with metal implants: a population-based cohort study in Sweden. J Natl Cancer Inst. 1995; 87: 28-33.
    • (1995) J. Natl. Cancer Inst. , vol.87 , pp. 28-33
    • Nyren, O.1    McLaughlin, J.K.2    Gridley, G.3
  • 131
    • 0034999690 scopus 로고    scopus 로고
    • The risk of cancer following total hip or knee arthroplasty
    • Tharani R, Dorey FJ, Schmalzried TP. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg. 2001; 83: 774-780.
    • (2001) J. Bone Joint Surg. , vol.83 , pp. 774-780
    • Tharani, R.1    Dorey, F.J.2    Schmalzried, T.P.3
  • 132
    • 0035207851 scopus 로고    scopus 로고
    • Chromosomal changes after surgery for joint replacement
    • Case CP. Chromosomal changes after surgery for joint replacement. J Bone Joint Surg. 2001; 83: 1093-1095.
    • (2001) J. Bone Joint Surg. , vol.83 , pp. 1093-1095
    • Case, C.P.1
  • 133
    • 0037463339 scopus 로고    scopus 로고
    • Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells
    • Coen N, Kadhim MA, Wright EG, et al. Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells. Br J Cancer. 2003; 88: 548-552.
    • (2003) Br. J. Cancer , vol.88 , pp. 548-552
    • Coen, N.1    Kadhim, M.A.2    Wright, E.G.3
  • 134
    • 0032190304 scopus 로고    scopus 로고
    • Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particles
    • Doorn PF, Campbell PA, Worrall J, et al. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res. 1998; 42: 103-111.
    • (1998) J. Biomed. Mater. Res. , vol.42 , pp. 103-111
    • Doorn, P.F.1    Campbell, P.A.2    Worrall, J.3
  • 135
    • 52449124174 scopus 로고    scopus 로고
    • How have alternative bearings (such as metal-on-metal, highly crosslinked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?
    • Callaghan JJ, Cuckler JM, Huddleston JI, et al. How have alternative bearings (such as metal-on-metal, highly crosslinked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S33-S38.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • Callaghan, J.J.1    Cuckler, J.M.2    Huddleston, J.I.3
  • 136
    • 0035236287 scopus 로고    scopus 로고
    • New joints for the Millennium: Wear control in total replacement hip joints
    • Dowson D. New joints for the Millennium: wear control in total replacement hip joints. Proc Inst Mech Eng [H]. 2001; 215: 335-358.
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , pp. 335-358
    • Dowson, D.1
  • 137
    • 0024255826 scopus 로고
    • The use of dense aluminaalumina ceramic combination in total hip replacement
    • Boutin P, Christel P, Dorlot JM, et al. The use of dense aluminaalumina ceramic combination in total hip replacement. J Biomed Mater Res. 1988; 22: 1203-1232.
    • (1988) J. Biomed. Mater. Res. , vol.22 , pp. 1203-1232
    • Boutin, P.1    Christel, P.2    Dorlot, J.M.3
  • 138
    • 0343969789 scopus 로고
    • Evolution of Hip arthroplasty
    • Amstutz H, ed, New York: Churchill Livingstone
    • Amstutz H. Evolution of Hip arthroplasty. In: Amstutz H, ed. Hip arthroplasty. New York: Churchill Livingstone; 1991: 1-14.
    • (1991) Hip. Arthroplasty , pp. 1-14
    • Amstutz, H.1
  • 139
    • 0026641524 scopus 로고
    • Sixteen-years' experience with ceramic hip prostheses
    • Mittelmeier H, Heisel J. Sixteen-years' experience with ceramic hip prostheses. Clin Orthop Relat Res. 1992; 282: 64-72.
    • (1992) Clin. Orthop. Relat. Res. , vol.282 , pp. 64-72
    • Mittelmeier, H.1    Heisel, J.2
  • 140
    • 0025350439 scopus 로고
    • Unsatisfactory results with a ceramic total hip prosthesis
    • Mahoney OM, Dimon JH III. Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg. 1990; 72: 663-671.
    • (1990) J. Bone Joint Surg. , vol.72 , pp. 663-671
    • Mahoney, O.M.1    Dimon III, J.H.2
  • 141
    • 0033771089 scopus 로고    scopus 로고
    • Zirconia as a sliding material: Histologic, laboratory, and clinical data
    • Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop Relat Res. 2000; 379: 94-112.
    • (2000) Clin. Orthop. Relat. Res. , vol.379 , pp. 94-112
    • Cales, B.1
  • 142
    • 0032886208 scopus 로고    scopus 로고
    • Poor eight-year survival of cemented zirconia-polyethylene total hip replacements
    • Allain J, Le Mouel S, Goutallier D, et al. Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg. 1999; 81: 835-842.
    • (1999) J. Bone Joint Surg. , vol.81 , pp. 835-842
    • Allain, J.1    Le Mouel, S.2    Goutallier, D.3
  • 143
    • 42649115453 scopus 로고    scopus 로고
    • Possible triggers for phase transformation in zirconia hip ball
    • Brown SS, Green DD, Pezzotti G, et al. Possible triggers for phase transformation in zirconia hip ball. J Biomed Mater Res. 2007; 85: 444-452.
    • (2007) J. Biomed. Mater. Res. , vol.85 , pp. 444-452
    • Brown, S.S.1    Green, D.D.2    Pezzotti, G.3
  • 144
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Clarke IC, Manaka M, Green DD, et al. Current status of zirconia used in total hip implants. J Bone Joint Surg. 2003; 85 (suppl 4) : 73-84.
    • (2003) J. Bone Joint Surg. , vol.85 , Issue.4 SUPPL. , pp. 73-84
    • Clarke, I.C.1    Manaka, M.2    Green, D.D.3
  • 146
    • 11744358091 scopus 로고    scopus 로고
    • Clinical results of alumina-onalumina couple in THR
    • Jacobs JJCT, ed, West Conshohocken, PA: American Society for Testing and Materials STP
    • Meunier ANR, Bizot P, Sedel L. Clinical results of alumina-onalumina couple in THR. In: Jacobs JJCT, ed. Alternate bearing surfaces in total joint replacement. Vol 1346. West Conshohocken, PA: American Society for Testing and Materials STP; 1998: 213-234.
    • (1998) Alternate Bearing Surfaces in Total Joint Replacement , vol.1346 , pp. 213-234
    • Meunier, A.N.R.1    Bizot, P.2    Sedel, L.3
  • 147
    • 0345167715 scopus 로고    scopus 로고
    • Ceramic components for total hip arthroplasty
    • Willmann G. Ceramic components for total hip arthroplasty. Orthop Int. 1997; 5: 269-277.
    • (1997) Orthop. Int. , vol.5 , pp. 269-277
    • Willmann, G.1
  • 148
    • 0033781822 scopus 로고    scopus 로고
    • Ceramic femoral head retrieval data
    • Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res. 2000; 379: 22-28.
    • (2000) Clin. Orthop. Relat. Res. , vol.379 , pp. 22-28
    • Willmann, G.1
  • 149
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study
    • Allain J, Roudot-Thoraval F, Delecrin J, et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg. 2003; 85: 825-830.
    • (2003) J. Bone Joint Surg. , vol.85 , pp. 825-830
    • Allain, J.1    Roudot-Thoraval, F.2    Delecrin, J.3
  • 150
    • 0031664878 scopus 로고    scopus 로고
    • Failure of a stainlesssteel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report
    • Allain J, Goutallier D, Voisin MC, et al. Failure of a stainlesssteel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report. J Bone Joint Surg. 1998; 80: 1355-1360.
    • (1998) J. Bone Joint Surg. , vol.80 , pp. 1355-1360
    • Allain, J.1    Goutallier, D.2    Voisin, M.C.3
  • 151
    • 0029902177 scopus 로고    scopus 로고
    • Ceramic femoral head fractures in total hip arthroplasty
    • Fritsch EW, Gleitz M. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Relat Res. 1996; 328: 129-136.
    • (1996) Clin. Orthop. Relat. Res. , vol.328 , pp. 129-136
    • Fritsch, E.W.1    Gleitz, M.2
  • 152
    • 0032782712 scopus 로고    scopus 로고
    • Analysis of a failed alumina THR ball head
    • Piconi C, Labanti M, Magnani G, et al. Analysis of a failed alumina THR ball head. Biomaterials. 1999; 20: 1637-1646.
    • (1999) Biomaterials , vol.20 , pp. 1637-1646
    • Piconi, C.1    Labanti, M.2    Magnani, G.3
  • 153
    • 0034082534 scopus 로고    scopus 로고
    • Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results
    • Dorr LD, Wan Z, Longjohn DB, et al. Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg. 2000; 82: 789-798.
    • (2000) J. Bone Joint Surg. , vol.82 , pp. 789-798
    • Dorr, L.D.1    Wan, Z.2    Longjohn, D.B.3
  • 155
    • 52449134811 scopus 로고    scopus 로고
    • How do alternative bearing surfaces influence wear behavior?
    • Clarke IC, Manley MT. How do alternative bearing surfaces influence wear behavior? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S86-S93.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • Clarke, I.C.1    Manley, M.T.2
  • 156
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips: The importance of acetabular component orientation
    • Walter WL, O'Toole GC, Walter WK, et al. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007; 22: 496-503.
    • (2007) J. Arthroplasty , vol.22 , pp. 496-503
    • Walter, W.L.1    O'Toole, G.C.2    Walter, W.K.3
  • 159
    • 38449101029 scopus 로고    scopus 로고
    • The squeaking hip: A cause for concern-disagrees
    • Yang CC, Kim RH, Dennis DA. The squeaking hip: a cause for concern-disagrees. Orthopedics. 2007; 30: 739-742.
    • (2007) Orthopedics , vol.30 , pp. 739-742
    • Yang, C.C.1    Kim, R.H.2    Dennis, D.A.3
  • 160
    • 2642584746 scopus 로고    scopus 로고
    • Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear
    • Walter WL, Insley GM, Walter WK, et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004; 19: 402-413.
    • (2004) J. Arthroplasty , vol.19 , pp. 402-413
    • Walter, W.L.1    Insley, G.M.2    Walter, W.K.3
  • 161
    • 44949094495 scopus 로고    scopus 로고
    • High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings
    • Keurentjes JC, Kuipers RM, Wever DJ, et al. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res. 2008; 466: 1438-1443.
    • (2008) Clin. Orthop. Relat. Res. , vol.466 , pp. 1438-1443
    • Keurentjes, J.C.1    Kuipers, R.M.2    Wever, D.J.3
  • 162
    • 48949118899 scopus 로고    scopus 로고
    • The noisy ceramic hip: Is component malpositioning the cause?
    • Restrepo C, Parvizi J, Kurtz SM, et al. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008; 23: 643-649.
    • (2008) J. Arthroplasty , vol.23 , pp. 643-649
    • Restrepo, C.1    Parvizi, J.2    Kurtz, S.M.3
  • 163
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    • Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty. 2000; 15: 793-795.
    • (2000) J. Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3
  • 164
    • 0035215635 scopus 로고    scopus 로고
    • Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
    • Morlock M, Nassutt R, Janssen R, et al. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001; 16: 1071-1074.
    • (2001) J. Arthroplasty , vol.16 , pp. 1071-1074
    • Morlock, M.1    Nassutt, R.2    Janssen, R.3
  • 165
    • 0345168992 scopus 로고    scopus 로고
    • Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
    • Stewart TD, Tipper JL, Insley G, et al. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res B Appl Biomater. 2003; 66: 567-573.
    • (2003) J. Biomed. Mater. Res. B Appl. Biomater. , vol.66 , pp. 567-573
    • Stewart, T.D.1    Tipper, J.L.2    Insley, G.3
  • 166
    • 55649088197 scopus 로고    scopus 로고
    • Osteolysis in third generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis
    • e13-e19
    • Murali R, Bonar SF, Kirsh G, et al. Osteolysis in third generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. J Arthroplasty. 2008; 23: 1240. e13-e19.
    • (2008) J. Arthroplasty , vol.23 , pp. 1240
    • Murali, R.1    Bonar, S.F.2    Kirsh, G.3
  • 167
    • 0041508240 scopus 로고    scopus 로고
    • New bearing surfaces: What does the future hold?
    • Fisher J, Hu X, Williams S, et al. New bearing surfaces: What does the future hold? Semin Arthroplasty. 2003; 14: 131-139.
    • (2003) Semin Arthroplasty , vol.14 , pp. 131-139
    • Fisher, J.1    Hu, X.2    Williams, S.3
  • 169
    • 0038613870 scopus 로고    scopus 로고
    • In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements
    • Williams S, Tipper JL, Ingham E, et al. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements. Proc Inst Mech Eng [H]. 2003; 217: 155-163.
    • (2003) Proc. Inst. Mech. Eng. [H] , vol.217 , pp. 155-163
    • Williams, S.1    Tipper, J.L.2    Ingham, E.3
  • 170
    • 22544453310 scopus 로고    scopus 로고
    • Alternative bearing surfaces in total hip arthroplasty
    • Tuli R, Parvizi J. Alternative bearing surfaces in total hip arthroplasty. Expert Rev Med Devices. 2005; 2: 445-452.
    • (2005) Expert Rev. Med. Devices , vol.2 , pp. 445-452
    • Tuli, R.1    Parvizi, J.2
  • 171
    • 52449107296 scopus 로고    scopus 로고
    • How have wear testing and joint simulator studies helped to discriminate among materials and designs?
    • McKellop HA, D'Lima D. How have wear testing and joint simulator studies helped to discriminate among materials and designs? J Am Acad Orthop Surg. 2008; 16 (suppl 1) : S111-S119.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.1 SUPPL.
    • McKellop, H.A.1    D'Lima, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.