메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Real-time, non-vision sensory feedback during minimally invasive surgery

Author keywords

Force; MEMS; MIS; Polymer based; Stiffness; Tactile sensor

Indexed keywords

APPLIED LOADS; AXIAL FORCES; DESIGN CONCEPT; DETAILED DESIGN; FEM ANALYSIS; LINEAR RELATIONSHIPS; LUMPED MODELS; MEASUREMENT SENSITIVITY; MINIMALLY INVASIVE SURGERY; POLYIMIDE POLYMERS; POLYMER BASED; SENSING ELEMENTS; SENSING UNIT; SENSOR DEVELOPMENT; TACTILE SENSING; TACTILE SENSORS; TISSUE INTERFACE; WORK PLAN;

EID: 77951109056     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/TENCON.2009.5396013     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 1
    • 0026938164 scopus 로고
    • New tactile sensor like the human hand and its applications
    • S. Omata and Y. Terunuma, "New tactile sensor like the human hand and its applications," Sensors and Actuators A: Physical, vol. 35, pp. 9-15, 1992.
    • (1992) Sensors and Actuators A: Physical , vol.35 , pp. 9-15
    • Omata, S.1    Terunuma, Y.2
  • 2
    • 2342595827 scopus 로고    scopus 로고
    • Real time robotic tactile sensor system for the determination of the physical properties of biomaterials
    • S. Omata, Y. Murayama, and C. E. Constantinou, "Real time robotic tactile sensor system for the determination of the physical properties of biomaterials," Sensors and Actuators A: Physical, vol. 112, pp. 278-285, 2004.
    • (2004) Sensors and Actuators A: Physical , vol.112 , pp. 278-285
    • Omata, S.1    Murayama, Y.2    Constantinou, C.E.3
  • 5
    • 39749088130 scopus 로고    scopus 로고
    • State-of-the-art in force and tactile sensing for minimally invasive surgery
    • DOI 10.1109/JSEN.2008.917481, 4453913
    • P. Puangmali, K. Althoefer, L. D. Seneviratne, D. Murphy, and P. Dasgupta, "State-of-the-art in force and tactile sensing for minimally invasive surgery," IEEE Sensors Journal, vol.8, pp. 371-380, 2008. (Pubitemid 351305853)
    • (2008) IEEE Sensors Journal , vol.8 , Issue.4 , pp. 371-380
    • Puangmali, P.1    Althoefer, K.2    Seneviratne, L.D.3    Murphy, D.4    Dasgupta, P.5
  • 6
    • 0034269558 scopus 로고    scopus 로고
    • Micromachined piezoelectric tactile sensor for an endoscopic grasper - Theory, fabrication and experiments
    • J. Dargahi, M. Parameswaran, and S. Payandeh, "Micromachined piezoelectric tactile sensor for an endoscopic grasper - theory, fabrication and experiments," Journal of Microelectromechanical Systems, vol. 9, pp. 329-335, 2000.
    • (2000) Journal of Microelectromechanical Systems , vol.9 , pp. 329-335
    • Dargahi, J.1    Parameswaran, M.2    Payandeh, S.3
  • 11
    • 0034247264 scopus 로고    scopus 로고
    • Silicon-based shear force sensor: Development and characterization
    • L. Wang and D. J. Beebe, "Silicon-based shear force sensor: development and characterization," Sensors and Actuators, A: Physical, vol. 84, pp. 33-44, 2000.
    • (2000) Sensors and Actuators, A: Physical , vol.84 , pp. 33-44
    • Wang, L.1    Beebe, D.J.2
  • 12
    • 0034467107 scopus 로고    scopus 로고
    • A Traction stress sensor array for use in high-resolution robotic tactile imaging
    • B. J. Kane, M. R. Cutkosky, and G. T. A. Kovacs, "A Traction stress sensor array for use in high-resolution robotic tactile imaging," Journal of Microelectromechanical Systems, vol. 9, pp. 425-434, 2000.
    • (2000) Journal of Microelectromechanical Systems , vol.9 , pp. 425-434
    • Kane, B.J.1    Cutkosky, M.R.2    Kovacs, G.T.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.