메뉴 건너뛰기




Volumn 112, Issue 2-3, 2004, Pages 278-285

Real time robotic tactile sensor system for the determination of the physical properties of biomaterials

Author keywords

Robot hand; Surgery robotics; Tactile sensor; Tele medical care; Virtual system

Indexed keywords

ACOUSTIC IMPEDANCE; BIOMATERIALS; BIOMEDICAL ENGINEERING; COMPUTER SIMULATION; DATA ACQUISITION; FEEDBACK; FREQUENCIES; OBJECT RECOGNITION; PHASE SHIFT; PIEZOELECTRIC TRANSDUCERS; RESONANCE; ROBOTICS; TISSUE;

EID: 2342595827     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2004.01.038     Document Type: Article
Times cited : (118)

References (24)
  • 2
    • 0026117012 scopus 로고
    • Polysilicon bridges for the realization of tactile sensors
    • Wolffenbuttle M.R., Regtin P.P.L. Polysilicon bridges for the realization of tactile sensors. Sens. Actuators, A. 26:1991;257-264.
    • (1991) Sens. Actuators, A , vol.26 , pp. 257-264
    • Wolffenbuttle, M.R.1    Regtin, P.P.L.2
  • 3
    • 0027644866 scopus 로고
    • A tactile sensor system for universal joint sections of manipulators
    • Yamada Y., Shin K., Tsuchida N., Konami M. A tactile sensor system for universal joint sections of manipulators. IEEE Trans. Rob. Autom. 9:1993;512-517.
    • (1993) IEEE Trans. Rob. Autom. , vol.9 , pp. 512-517
    • Yamada, Y.1    Shin, K.2    Tsuchida, N.3    Konami, M.4
  • 6
    • 0029325754 scopus 로고
    • Object imaging with a piezoelectric robotic tactile sensor
    • Kolesar E.S., Dyson C.S. Object imaging with a piezoelectric robotic tactile sensor. J. Microelectromech. Syst. 4:1995;87-96.
    • (1995) J. Microelectromech. Syst. , vol.4 , pp. 87-96
    • Kolesar, E.S.1    Dyson, C.S.2
  • 8
  • 10
    • 0002575093 scopus 로고    scopus 로고
    • Tactile sensing for mechatronics - A state of the art survey
    • Lee M.H., Nicholls H.R. Tactile sensing for mechatronics - a state of the art survey. Mechatronics. 9:1999;1-31.
    • (1999) Mechatronics , vol.9 , pp. 1-31
    • Lee, M.H.1    Nicholls, H.R.2
  • 11
    • 0026938164 scopus 로고
    • New tactile sensor like the human hand and its applications
    • Omata S., Terunuma Y. New tactile sensor like the human hand and its applications. Sens. Actuators, A. 35:1992;9-15.
    • (1992) Sens. Actuators, A , vol.35 , pp. 9-15
    • Omata, S.1    Terunuma, Y.2
  • 12
    • 0029347493 scopus 로고
    • Modeling of micturition characteristics based on prostate stiffness modulation induced using hormones and adrenergic antagonists
    • Omata S., Constantinou C.E. Modeling of micturition characteristics based on prostate stiffness modulation induced using hormones and adrenergic antagonists. IEEE Trans. Biomed. Eng. 42(8):1995;843-848.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.8 , pp. 843-848
    • Omata, S.1    Constantinou, C.E.2
  • 13
    • 0029852507 scopus 로고    scopus 로고
    • Usefulness of a new tactile sensor for measurement of uterine cervical ripening in mice in a quantitative and noninvasive manner
    • Kaga N., Katsuki Y., Kakinuma C., Obata M., Shibutani Y., Omata S. Usefulness of a new tactile sensor for measurement of uterine cervical ripening in mice in a quantitative and noninvasive manner. Am. J. Obstet. Gynecol. 175(3):1996;713-718.
    • (1996) Am. J. Obstet. Gynecol. , vol.175 , Issue.3 , pp. 713-718
    • Kaga, N.1    Katsuki, Y.2    Kakinuma, C.3    Obata, M.4    Shibutani, Y.5    Omata, S.6
  • 14
    • 2342540806 scopus 로고    scopus 로고
    • Frequency deviation detecting circuit and measuring apparatus using the frequency deviation detecting circuit, United States Patent No. 5,766,137
    • S. Omata, Frequency deviation detecting circuit and measuring apparatus using the frequency deviation detecting circuit, United States Patent No. 5,766,137 (1998).
    • (1998)
    • Omata, S.1
  • 15
    • 6844241958 scopus 로고    scopus 로고
    • Chronology and urodynamic characterization of micturition in neurohormonally induced experimental prostate growth in the rat
    • Lee J.Z., Omata S., Tillig B., Perkash I., Constantinou C.E. Chronology and urodynamic characterization of micturition in neurohormonally induced experimental prostate growth in the rat. Neurourol. Urodyn. 17:1998;55-69.
    • (1998) Neurourol. Urodyn. , vol.17 , pp. 55-69
    • Lee, J.Z.1    Omata, S.2    Tillig, B.3    Perkash, I.4    Constantinou, C.E.5
  • 16
    • 0032701276 scopus 로고    scopus 로고
    • Palpation of the skin with a robot finger: An attempt to measure skin stiffness with a probe loaded with a newly developed tactile vibration sensor and displacement sensor
    • Sasai S., Zhen Y., Suetake T., Tanita Y., Omata S., Tagami H. Palpation of the skin with a robot finger: an attempt to measure skin stiffness with a probe loaded with a newly developed tactile vibration sensor and displacement sensor. Skin Res. Technol. 5:1999;237-246.
    • (1999) Skin Res. Technol. , vol.5 , pp. 237-246
    • Sasai, S.1    Zhen, Y.2    Suetake, T.3    Tanita, Y.4    Omata, S.5    Tagami, H.6
  • 17
    • 0033935317 scopus 로고    scopus 로고
    • Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy
    • K. Kusaka, Y. Harihara, M. Makuuchi, S. Omata, Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy, J. Am. Coll. Surg. 191 (2000).
    • (2000) J. Am. Coll. Surg. , vol.191
    • Kusaka, K.1    Harihara, Y.2    Makuuchi, M.3    Omata, S.4
  • 18
    • 2342523039 scopus 로고    scopus 로고
    • Detrusor stiffness: New instrumentation for the in vitro evaluation of bladder contraction
    • Omata S., Diep N., Constantinou C.E. Detrusor stiffness: new instrumentation for the in vitro evaluation of bladder contraction. Neurourol. Urodyn. 19:2000;415-417.
    • (2000) Neurourol. Urodyn. , vol.19 , pp. 415-417
    • Omata, S.1    Diep, N.2    Constantinou, C.E.3
  • 19
    • 2342463974 scopus 로고    scopus 로고
    • Validation of hardness measurement of dental hard tissue using a tactile sensor: In vitro study
    • Hata S., Hata H., Omata S., Honda K., Mayanagi H. Validation of hardness measurement of dental hard tissue using a tactile sensor: in vitro study. Pediatr. Dent. J. 10:2000;149-154.
    • (2000) Pediatr. Dent. J. , vol.10 , pp. 149-154
    • Hata, S.1    Hata, H.2    Omata, S.3    Honda, K.4    Mayanagi, H.5
  • 20
    • 0033967876 scopus 로고    scopus 로고
    • Myocardial tactile stiffness during acute reduction of coronary blood flow
    • Miyaji K., Sugiura S., Hirotaka H., Takamoto S., Omata S. Myocardial tactile stiffness during acute reduction of coronary blood flow. Ann. Thorac. Surg. 69:2000;151-155.
    • (2000) Ann. Thorac. Surg. , vol.69 , pp. 151-155
    • Miyaji, K.1    Sugiura, S.2    Hirotaka, H.3    Takamoto, S.4    Omata, S.5
  • 22
    • 0022463809 scopus 로고
    • Robotic tactile sensing
    • K.E. Pennywitt, Robotic tactile sensing, Byte 11 (1) (1986) 177-200.
    • (1986) Byte , vol.11 , Issue.1 , pp. 177-200
    • Pennywitt, K.E.1
  • 24
    • 0000709060 scopus 로고
    • Academic Press, New York
    • W.P. Mason, Physical Acoustics, vol. 1-A, Academic Press, New York, 1964, pp. 220-270.
    • (1964) Physical Acoustics , vol.1 A , pp. 220-270
    • Mason, W.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.