메뉴 건너뛰기




Volumn 15, Issue 5, 2006, Pages 296-304

Artificial tactile sensing in minimally invasive surgery - A new technical approach

Author keywords

Laparoscopy; Minimally invasive surgery; MIS; Palpation; Tactile instrument; Tactile sensor

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CATTLE; COMPUTER PROGRAM; DIAGNOSTIC VALUE; ELECTRONIC SENSOR; ENDOSCOPE; EQUIPMENT DESIGN; FEASIBILITY STUDY; FORCEPS; IMAGE ANALYSIS; LAPAROSCOPY; MINIMALLY INVASIVE SURGERY; NONHUMAN; PALPATION; PATIENT SAFETY; PRIORITY JOURNAL; SURGICAL EQUIPMENT; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE; SWINE; TACTILE SENSOR; TACTILE STIMULATION; TISSUE STRUCTURE; TREATMENT INDICATION;

EID: 33750284702     PISSN: 13645706     EISSN: 13652931     Source Type: Journal    
DOI: 10.1080/13645700600836299     Document Type: Article
Times cited : (82)

References (20)
  • 1
    • 0027616374 scopus 로고
    • Intelligent Surgical Instrument System ISIS
    • Melzer, A. and Schurr, M. O. and Kunert, W. and Buess, G. and (1993) Intelligent Surgical Instrument System ISIS. Concept and preliminary experimental application of components and prototypes. End Surg, 1, pp. 165-70.
    • (1993) End Surg , vol.1 , pp. 165-170
    • Melzer, A.1    Schurr, M.O.2    Kunert, W.3    Buess, G.4
  • 2
    • 0343340044 scopus 로고    scopus 로고
    • Robotics and allied technologies in endoscopic surgery
    • Buess, G. F. and Schurr, M. O. and Fischer, S. C. (2000) Robotics and allied technologies in endoscopic surgery. Arch Surg, 135, pp. 229-35.
    • (2000) Arch Surg , vol.135 , pp. 229-235
    • Buess, G.F.1    Schurr, M.O.2    Fischer, S.C.3
  • 3
    • 0032834521 scopus 로고    scopus 로고
    • Tactile feedback is present during minimally invasive surgery
    • Bholat, O. S. and Halluck, R. S. and Murray, W. B. and Gorman, P. J. and (1999) Tactile feedback is present during minimally invasive surgery. J Am Coll Surg, 189, pp. 349-55.
    • (1999) J Am Coll Surg , vol.189 , pp. 349-355
    • Bholat, O.S.1    Halluck, R.S.2    Murray, W.B.3    Gorman, P.J.4
  • 4
    • 11144258727 scopus 로고    scopus 로고
    • Force feedback plays a significant role in minimally invasive surgery
    • Tholey, G. and Desai, J. P. and Castallanos, A. E. (2005) Force feedback plays a significant role in minimally invasive surgery. Ann Surg, 241, pp. 102-9.
    • (2005) Ann Surg , vol.241 , pp. 102-109
    • Tholey, G.1    Desai, J.P.2    Castallanos, A.E.3
  • 5
    • 0032861335 scopus 로고    scopus 로고
    • Force controlled and teleoperated endoscopic grasper for minimally invasive surgery - Experimental performance evaluation
    • Rosen, J. and Hannaford, B. and Mac Farlane, M. P. and Sianan, M. N. (1999) Force controlled and teleoperated endoscopic grasper for minimally invasive surgery - experimental performance evaluation. IEEE Trans Biomed Eng, 46, pp. 1212-21.
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 1212-1221
    • Rosen, J.1    Hannaford, B.2    Mac Farlane, M.P.3    Sianan, M.N.4
  • 6
    • 0242522213 scopus 로고    scopus 로고
    • Advanced devices for the operating room of the future
    • Rattner, D. W. and Park, A. (2003) Advanced devices for the operating room of the future. Seminars in laparoscopic surgery, 10, pp. 85-9.
    • (2003) Seminars in Laparoscopic Surgery , vol.10 , pp. 85-89
    • Rattner, D.W.1    Park, A.2
  • 7
    • 84956607614 scopus 로고    scopus 로고
    • Tactile feedback and display system for CT-guided, robot-assisted percutaneous procedures
    • Yanof, J. and Bauer, C. and Wood, B. (2004) Tactile feedback and display system for CT-guided, robot-assisted percutaneous procedures. International Congress Series, 1268, pp. 521-6.
    • (2004) International Congress Series , vol.1268 , pp. 521-526
    • Yanof, J.1    Bauer, C.2    Wood, B.3
  • 8
    • 2342553014 scopus 로고    scopus 로고
    • Sendors in minimally invasive therapy - A technology coming of age
    • Schurr, M. O. (2004) Sendors in minimally invasive therapy - a technology coming of age. Min Invas Ther & Allied Technol, 13, pp. 67.
    • (2004) Min Invas Ther & Allied Technol , vol.13 , pp. 67
    • Schurr, M.O.1
  • 9
    • 0002575093 scopus 로고    scopus 로고
    • Tactile sensing for mechatronics - A state of the art survey
    • Lee, M. H. and Nicholls, H. R. (1999) Tactile sensing for mechatronics - a state of the art survey. Mechatronics, 9, pp. 1-31.
    • (1999) Mechatronics , vol.9 , pp. 1-31
    • Lee, M.H.1    Nicholls, H.R.2
  • 10
    • 0042431781 scopus 로고    scopus 로고
    • Tactile sensing technology for minimal access surgery - A review
    • Etlaib, M. E. H. and Hewit, J. R. (2003) Tactile sensing technology for minimal access surgery - a review. Mechatronics, 13, pp. 1163-77.
    • (2003) Mechatronics , vol.13 , pp. 1163-1177
    • Etlaib, M.E.H.1    Hewit, J.R.2
  • 12
    • 33750329291 scopus 로고    scopus 로고
    • System design of a novel tactile instrument for use in minimally invasive surgery based on an international market study
    • Ho, C. N. and Schostek, S. and Fuchsberger, A. and Kalanovic, D. and (2004) System design of a novel tactile instrument for use in minimally invasive surgery based on an international market study. Biomed Tech (Berl), 49 Suppl 1, pp. 44-5.
    • (2004) Biomed Tech (Berl) , vol.49 , Issue.SUPPL. 1 , pp. 44-45
    • Ho, C.N.1    Schostek, S.2    Fuchsberger, A.3    Kalanovic, D.4
  • 13
    • 1342267288 scopus 로고    scopus 로고
    • Evaluation of bluetooth as a replacement for cables in intensive care and surgery
    • Wallin, M. K. and Wajntraub, S. (2004) Evaluation of bluetooth as a replacement for cables in intensive care and surgery. Anesth Analg, 98, pp. 763-7.
    • (2004) Anesth Analg , vol.98 , pp. 763-767
    • Wallin, M.K.1    Wajntraub, S.2
  • 14
    • 6344228124 scopus 로고    scopus 로고
    • In - vivo and in - situ compressive poperties of porcine abdominal soft tissues
    • Brown, J. D. and Rosen, J. and Kim, Y. S. and Chang, L. and (2003) In-vivo and in-situ compressive poperties of porcine abdominal soft tissues. Stud Health Technol Inform, 94, pp. 26-32.
    • (2003) Stud Health Technol Inform , vol.94 , pp. 26-32
    • Brown, J.D.1    Rosen, J.2    Kim, Y.S.3    Chang, L.4
  • 15
    • 0032932330 scopus 로고    scopus 로고
    • High pressures are generated at the tip of laparoscopic graspers
    • Cartmill, J. A. and Shakeshaft, A. J. and Walsh, W. R. and Martin, C. J. (1999) High pressures are generated at the tip of laparoscopic graspers. Aust N Z J Surg, 69, pp. 127-30.
    • (1999) Aust N Z J Surg , vol.69 , pp. 127-130
    • Cartmill, J.A.1    Shakeshaft, A.J.2    Walsh, W.R.3    Martin, C.J.4
  • 16
    • 0031713344 scopus 로고    scopus 로고
    • The use of a vibrotactile sensor as an artificial sense of touch for the tissues of the head and neck
    • Plinkert, P. K. and Baumann, L. and Flemming, E. and (1998) The use of a vibrotactile sensor as an artificial sense of touch for the tissues of the head and neck. Min Invas Ther & Allied Technol, 7, pp. 111-5.
    • (1998) Min Invas Ther & Allied Technol , vol.7 , pp. 111-115
    • Plinkert, P.K.1    Baumann, L.2    Flemming, E.3
  • 18
    • 0032073199 scopus 로고    scopus 로고
    • A sixty-four element tactile display using shape memory alloy wires
    • Taylor, P. M. and Moser, A. and Creed, A. (1998) A sixty-four element tactile display using shape memory alloy wires. Displays, 18, pp. 163-8.
    • (1998) Displays , vol.18 , pp. 163-168
    • Taylor, P.M.1    Moser, A.2    Creed, A.3
  • 19
    • 84867435054 scopus 로고    scopus 로고
    • Electromechanical Design of a miniature tactile shape display for minimally invasive surgery
    • Ottermo, M. V. and Stavdahl, O. and Johansen, T. A. (2005) Electromechanical Design of a miniature tactile shape display for minimally invasive surgery. Proc. Worldhaptics, pp. 561-2.
    • (2005) Proc. Worldhaptics , pp. 561-562
    • Ottermo, M.V.1    Stavdahl, O.2    Johansen, T.A.3
  • 20
    • 20344380214 scopus 로고    scopus 로고
    • Electrorheological tactel elements
    • Klein, D. and Freimuth, H. and Monkman, G. and (2005) Electrorheological tactel elements. Mechatronics, 15, pp. 883-97.
    • (2005) Mechatronics , vol.15 , pp. 883-897
    • Klein, D.1    Freimuth, H.2    Monkman, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.