메뉴 건너뛰기




Volumn 44, Issue 5, 2010, Pages 1736-1741

Rapid and sensitive detection of giardia Lamblia using a piezoelectric cantilever biosensor in finished and source waters

Author keywords

[No Author keywords available]

Indexed keywords

CANTILEVER SENSORS; DETECTION EXPERIMENTS; DETECTION LIMITS; ENVIRONMENTAL SCANNING ELECTRON MICROSCOPES; FLOW ARRANGEMENTS; GIARDIA LAMBLIA; HIGH ORDER MODE; HIGH-FLOW RATE; LOW CONCENTRATIONS; PARASITE-; PIEZOELECTRIC CANTILEVERS; PRE-CONCENTRATION; RESONANT FREQUENCIES; RIVER WATER; SENSITIVE DETECTION; SENSOR RESPONSE; SENSOR SURFACES; SOURCE WATERS; WATER MATRICES;

EID: 77749295248     PISSN: 0013936X     EISSN: 15205851     Source Type: Journal    
DOI: 10.1021/es9033843     Document Type: Article
Times cited : (44)

References (24)
  • 1
    • 0034933985 scopus 로고    scopus 로고
    • Biology of giardia lamblia
    • Adam, R. D. Biology of Giardia lamblia. Clin. Microbiol. Rev. 2001, 14 (3), 447-475.
    • (2001) Clin. Microbiol. Rev. , vol.14 , Issue.3 , pp. 447-475
    • Adam, R.D.1
  • 4
    • 77749343685 scopus 로고    scopus 로고
    • USEPA. Method 1623: Cryptosporidium and Giardia in water by filtration/IMS/FA
    • USEPA. Method 1623: Cryptosporidium and Giardia in water by filtration/IMS/FA; 2005.
    • (2005)
  • 5
    • 0031035648 scopus 로고    scopus 로고
    • Comparison of primers and optimization of PCR conditions for detection of Cryptosporidium parvum and Giardia lamblia in water
    • Rochelle, P. A.; DeLeon, R.; Stewart, M. H.; Wolfe, R. L. Comparison of primers and optimization of PCR conditions for detection of Cryptosporidium parvum and Giardia lamblia in water. Appl. Environ. Microbiol. 1997, 63 (1), 106-114.
    • (1997) Appl. Environ. Microbiol. , vol.63 , Issue.1 , pp. 106-114
    • Rochelle, P.A.1    Deleon, R.2    Stewart, M.H.3    Wolfe, R.L.4
  • 6
    • 0141482157 scopus 로고    scopus 로고
    • Real-time PCR for quantification of Giardia and Cryptosporidium in environ-mental water samples and sewage
    • Guy, R. A.; Payment, P.; Krull, U. J.; Horgen, P. A. Real-time PCR for quantification of Giardia and Cryptosporidium in environ-mental water samples and sewage, Appl. Environ. Microbiol. 2003, 69 (9), 5178-5185.
    • (2003) Appl. Environ. Microbiol. , vol.69 , Issue.9 , pp. 5178-5185
    • Guy, R.A.1    Payment, P.2    Krull, U.J.3    Horgen, P.A.4
  • 7
    • 0027274037 scopus 로고
    • Evaluation of an enzyme-linked immunosorbent assay for the detection of Giardia lamblia in stool specimens
    • DOI 10.1016/0732-8893(93)90086-M
    • Rosenblatt, J. E.; Sloan, L. M.; Schneider, S. K. Evaluation of an enzyme-linked-immunosorbent-assay for the detection of Giardia lamblia in stool specimens. Diagn. Microbiol. Infect. Dis. 1993, 16 (4), 337-341. (Pubitemid 23146838)
    • (1993) Diagnostic Microbiology and Infectious Disease , vol.16 , Issue.4 , pp. 337-341
    • Rosenblatt, J.E.1    Sloan, L.M.2    Schneider, S.K.3
  • 8
    • 0033940173 scopus 로고    scopus 로고
    • Evaluation of four enzyme immunoassays for the detection of Giardia lamblia antigen in stool specimens
    • Maraha, B.; Buiting, A. G. M. Evaluation of four enzyme immunoassays for the detection of Giardia lamblia antigen in stool specimens. Eur. J. Clin. Microbiol. Infect. Dis. 2000,19 (6), 485-487.
    • (2000) Eur. J. Clin. Microbiol. Infect. Dis. , vol.19 , Issue.6 , pp. 485-487
    • Maraha, B.1    Buiting, A.G.M.2
  • 9
    • 64349098705 scopus 로고    scopus 로고
    • Surface-enhanced resonance Raman spectroscopy for the rapid detection of Cryptosporidium parvum and Giardia lamblia
    • Rule, K. L.; Vikesland, P. J. Surface-enhanced resonance Raman spectroscopy for the rapid detection of Cryptosporidium parvum and Giardia lamblia. Enpiron. Sci. Technol. 2009, 43 (4), 1147-1152.
    • (2009) Enpiron. Sci. Technol. , vol.43 , Issue.4 , pp. 1147-1152
    • Rule, K.L.1    Vikesland, P.J.2
  • 10
    • 4344700526 scopus 로고    scopus 로고
    • Filter-based microfluidic device as a platform for immunof-luorescent assay of microbial cells
    • Zhu, L.; Zhang, Q.; Feng, H. H.; Ang, S.; Chauc, F. S.; Liu, W. T. Filter-based microfluidic device as a platform for immunof-luorescent assay of microbial cells. Lab Chip 2004, 4 (4), 337-341.
    • (2004) Lab Chip , vol.4 , Issue.4 , pp. 337-341
    • Zhu, L.1    Zhang, Q.2    Feng, H.H.3    Ang, S.4    Chauc, F.S.5    Liu, W.T.6
  • 11
    • 61549091536 scopus 로고    scopus 로고
    • Detection of pathogen based on the catalytic growth of gold nanocrystals
    • Li, X. X.; Cao, C.; Han, S. J.; Sim, S. J. Detection of pathogen based on the catalytic growth of gold nanocrystals. Water Res. 2009, 43 (5), 1425-1431.
    • (2009) Water Res. , vol.43 , Issue.5 , pp. 1425-1431
    • Li, X.X.1    Cao, C.2    Han, S.J.3    Sim, S.J.4
  • 12
    • 33847686254 scopus 로고    scopus 로고
    • A method of measuring Escherichia coli O157:H7 at 1 cell/mL in 1 liter sample using antibody functionalized piezoelectric-excited millimeter-sized cantilever sensor
    • DOI 10.1021/es061947p
    • Campbell, G. A.; Mutharasan, R. A method of measuring Escherichia coli 0157: H7 at 1 cell/mL in 1 liter sample using antibody functionalized piezoelectric-excited millimeter-sized cantilever sensor. Environ. Sci. Technol. 2007, 41 (5), 1668-1674. (Pubitemid 46362469)
    • (2007) Environmental Science and Technology , vol.41 , Issue.5 , pp. 1668-1674
    • Campbell, G.A.1    Mutharasan, R.2
  • 13
    • 33846986353 scopus 로고    scopus 로고
    • Method of measuring Bacillus anthracis spores in the presence of copious amounts of Bacillus thuringiensis and Bacillus cereus
    • Campbell, G. A.; Mutharasan, R. Method of measuring Bacillus anthracis spores in the presence of copious amounts of Bacillus thuringiensis and Bacillus cereus. Anal. Chem. 2007, 79(3), 1145-1152.
    • (2007) Anal. Chem. , vol.79 , Issue.3 , pp. 1145-1152
    • Campbell, G.A.1    Mutharasan, R.2
  • 14
    • 65549148492 scopus 로고    scopus 로고
    • Real-time microgravimetric quantification of Cryptosporidium parvum in the presence of potential interferents
    • Poitras, C.; Fatisson, J.; Tufenkji, N. Real-time microgravimetric quantification of Cryptosporidium parvum in the presence of potential interferents. Water Res. 2009, 43 (10), 2631-2638.
    • (2009) Water Res. , vol.43 , Issue.10 , pp. 2631-2638
    • Poitras, C.1    Fatisson, J.2    Tufenkji, N.3
  • 15
    • 38749129750 scopus 로고    scopus 로고
    • Near real-time detection of Cryptosporidium parvum oocyst by IgM-functionalized piezoelectric-excited millimeter-sized cantilever biosensor
    • Campbell, G. A;. Mutharasan, R. Near real-time detection of Cryptosporidium parvum oocyst by IgM-functionalized piezoelectric-excited millimeter-sized cantilever biosensor. Biosens. Bioelectron. 2008, 23 (7), 1039-1045.
    • (2008) Biosens. Bioelectron. , vol.23 , Issue.7 , pp. 1039-1045
    • Campbell, G.A.1    Mutharasan, R.2
  • 16
    • 49049106161 scopus 로고    scopus 로고
    • Effects of flow rate on sensitivity and affinity in flow injection biosensor systems studied by 55-MHz wireless quartz crystal microbalance
    • Ogi, H.; Fukunishi, Y.; Omori, T.; Hatanaka, K.; Hirao, M.; Nishiyama, M. Effects of flow rate on sensitivity and affinity in flow injection biosensor systems studied by 55-MHz wireless quartz crystal microbalance. Anal. Chem. 2008, 80 (14), 5494-5500.
    • (2008) Anal. Chem. , vol.80 , Issue.14 , pp. 5494-5500
    • Ogi, H.1    Fukunishi, Y.2    Omori, T.3    Hatanaka, K.4    Hirao, M.5    Nishiyama, M.6
  • 17
    • 14844362642 scopus 로고    scopus 로고
    • Cantilever-based biosensors
    • Ziegler, C. Cantilever-based biosensors. Anal. Bioanal. Chem. 2004, 379 (7-8), 946-959.
    • (2004) Anal. Bioanal. Chem. , vol.379 , Issue.7-8 , pp. 946-959
    • Ziegler, C.1
  • 18
    • 34247120167 scopus 로고    scopus 로고
    • Method for label-free detection of femtogram quantities of biologics in flowing liquid samples
    • DOI 10.1021/ac0621726
    • Maraldo, D.; Rijal, K.; Campbell, G.; Mutharasan, R. Method for label-free detection of femtogram quantities of biologies in flowing liquid samples. Anal Chem. 2007, 79 (7), 2762-2770. (Pubitemid 46595629)
    • (2007) Analytical Chemistry , vol.79 , Issue.7 , pp. 2762-2770
    • Maraldo, D.1    Rijal, K.2    Campbell, G.3    Mutharasan, R.4
  • 19
    • 33746341793 scopus 로고    scopus 로고
    • An updated review on Cryptosporidium and Giardia
    • Huang, D. B.; White, A. C. An updated review on Cryptosporidium and Giardia. Gastroenterol. Clin. North Am. 2006, 35 (2), 291-314.
    • (2006) Gastroenterol. Clin. North Am. , vol.35 , Issue.2 , pp. 291-314
    • Huang, D.B.1    White, A.C.2
  • 20
    • 32844475045 scopus 로고    scopus 로고
    • Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL
    • DOI 10.1016/j.bios.2005.08.001, PII S0956566305002460
    • Campbell, G. A.; Mutharasan, R. Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL. Biosens. Bioelectron. 2006, 21 (9), 1684-1692. (Pubitemid 43254757)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.9 , pp. 1684-1692
    • Campbell, G.A.1    Mutharasan, R.2
  • 21
    • 35448959959 scopus 로고    scopus 로고
    • Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL
    • Maraldo, D.; Mutharasan, R. Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL. Anal. Chem. 2007, 79 (20), 7636-7643.
    • (2007) Anal. Chem. , vol.79 , Issue.20 , pp. 7636-7643
    • Maraldo, D.1    Mutharasan, R.2
  • 22
    • 41849151140 scopus 로고    scopus 로고
    • Making it stick: Convection, reaction and diffusion in surface-based biosensors
    • Squires, T. M.; Messinger, R. J.; Manaus, S. R. Making it stick: convection, reaction and diffusion in surface-based biosensors. Nat. Biotechnol. 2008, 26 (4), 417-426.
    • (2008) Nat. Biotechnol. , vol.26 , Issue.4 , pp. 417-426
    • Squires, T.M.1    Messinger, R.J.2    Manaus, S.R.3
  • 23
    • 35448949207 scopus 로고    scopus 로고
    • Method for quantification of a prostate cancer biomarker in urine without sample preparation
    • DOI 10.1021/ac070895z
    • Maraldo, D.; Garcia, F. U.; Mutharasan, R. Method for quantification of a prostate cancer biomarker in urine without sample preparation. Anal. Chem. 2007, 79 (20), 7683-7690. (Pubitemid 47622396)
    • (2007) Analytical Chemistry , vol.79 , Issue.20 , pp. 7683-7690
    • Maraldo, D.1    Garcia, F.U.2    Mutharasan, R.3
  • 24
    • 35348982230 scopus 로고    scopus 로고
    • PEMC-based method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copious noncomplementary strands
    • DOI 10.1021/ac0712042
    • Rijal, K.; Mutharasan, R. PEMC-based method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copious noncomplementary strands. Anal. Chem. 2007, 79 (19), 7392-7400. (Pubitemid 47606106)
    • (2007) Analytical Chemistry , vol.79 , Issue.19 , pp. 7392-7400
    • Rijal, K.1    Mutharasan, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.