메뉴 건너뛰기




Volumn 144, Issue 1, 2010, Pages 146-152

Automatic electrochemical sequential processing in a microsystem for urea detection

Author keywords

Ammonia; Automatic processing; Electrowetting; pH regulation; Urea; Valves

Indexed keywords

AIR-GAP AMMONIA SENSORS; AUTOMATIC PROCESSING; DELAY LINE; ELECTRO WETTING; ELECTRODE POTENTIALS; FLOW CHANNELS; GASEOUS AMMONIA; GLASS SUBSTRATES; INJECTION VALVE; MICRO-ANALYSIS SYSTEMS; MIXING AREA; MIXING CHAMBER; MIXING TIME; NERNSTIAN RESPONSE; PH REGULATION; POLYDIMETHYLSILOXANE PDMS; SENSING FUNCTIONS; SEQUENTIAL PROCESSING; SOLUTION PH; STANDARD SOLUTIONS; THREE ELECTRODE-SYSTEM; UREA DETECTION; VALVE OPERATION;

EID: 74149094513     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.10.048     Document Type: Article
Times cited : (11)

References (29)
  • 1
    • 0032746841 scopus 로고    scopus 로고
    • Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays
    • Duffy D.C., Gillis H.L., Lin J., Norman J., Sheppard F., and Kellogg G.J. Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays. Anal. Chem. 71 (1999) 4669-4678
    • (1999) Anal. Chem. , vol.71 , pp. 4669-4678
    • Duffy, D.C.1    Gillis, H.L.2    Lin, J.3    Norman, J.4    Sheppard, F.5    Kellogg, G.J.6
  • 2
    • 23144452296 scopus 로고    scopus 로고
    • Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection
    • Wang C.-H., and Lee G.-B. Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection. Biosens. Bioelectron. 21 (2005) 419-425
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 419-425
    • Wang, C.-H.1    Lee, G.-B.2
  • 3
    • 33947095553 scopus 로고    scopus 로고
    • Integrated microfluidic systems for automatic glucose sensing and insulin injection
    • Huang C.-J., Chen Y.-H., Wang C.-H., Chou T.-C., and Lee G.-B. Integrated microfluidic systems for automatic glucose sensing and insulin injection. Sens. Actuators B 122 (2007) 461-468
    • (2007) Sens. Actuators B , vol.122 , pp. 461-468
    • Huang, C.-J.1    Chen, Y.-H.2    Wang, C.-H.3    Chou, T.-C.4    Lee, G.-B.5
  • 4
    • 37249087141 scopus 로고    scopus 로고
    • Automated control of local solution environments in open-volume microfluidics
    • Bridle H., Olofsson J., Jesorka A., and Orwar O. Automated control of local solution environments in open-volume microfluidics. Anal. Chem. 79 (2007) 9286-9293
    • (2007) Anal. Chem. , vol.79 , pp. 9286-9293
    • Bridle, H.1    Olofsson, J.2    Jesorka, A.3    Orwar, O.4
  • 6
    • 44649096274 scopus 로고    scopus 로고
    • Microanalysis system with automatic valve operation, pH regulation, and detection functions
    • Hosono H., Satoh W., Toya M., Morimoto K., Fukuda J., and Suzuki H. Microanalysis system with automatic valve operation, pH regulation, and detection functions. Sens. Actuators B 132 (2008) 614-622
    • (2008) Sens. Actuators B , vol.132 , pp. 614-622
    • Hosono, H.1    Satoh, W.2    Toya, M.3    Morimoto, K.4    Fukuda, J.5    Suzuki, H.6
  • 7
    • 46249092235 scopus 로고    scopus 로고
    • Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans
    • Chung K., Crane M.M., and Lu H. Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans. Nat. Methods 5 (2008) 637-643
    • (2008) Nat. Methods , vol.5 , pp. 637-643
    • Chung, K.1    Crane, M.M.2    Lu, H.3
  • 9
    • 1642525649 scopus 로고    scopus 로고
    • New type of glucose sensor based on enzymatic conversion of gel volume into liquid column length
    • Suzuki H., Kumagai A., Ogawa K., and Kokufuta E. New type of glucose sensor based on enzymatic conversion of gel volume into liquid column length. Biomacromolecules 5 (2004) 486-491
    • (2004) Biomacromolecules , vol.5 , pp. 486-491
    • Suzuki, H.1    Kumagai, A.2    Ogawa, K.3    Kokufuta, E.4
  • 10
    • 0037086387 scopus 로고    scopus 로고
    • A disposable "intelligent mosquito" with a reversible sampling mechanism using the volume-phase transition of a gel
    • Suzuki H., Tokuda T., and Kobayashi K. A disposable "intelligent mosquito" with a reversible sampling mechanism using the volume-phase transition of a gel. Sens. Actuators B 83 (2002) 53-59
    • (2002) Sens. Actuators B , vol.83 , pp. 53-59
    • Suzuki, H.1    Tokuda, T.2    Kobayashi, K.3
  • 11
    • 9144245581 scopus 로고    scopus 로고
    • Electrowetting (EW)-based valve combined with hydrophilic Teflon microfluidic guidance in controlling continuous fluid flow
    • Cheng J.-Y., and Hsiung L.-C. Electrowetting (EW)-based valve combined with hydrophilic Teflon microfluidic guidance in controlling continuous fluid flow. Biomed. Microdevices 6 (2004) 341-347
    • (2004) Biomed. Microdevices , vol.6 , pp. 341-347
    • Cheng, J.-Y.1    Hsiung, L.-C.2
  • 12
    • 33746501441 scopus 로고    scopus 로고
    • Micro analysis system for pH and protease activities with an integrated sample injection mechanism
    • Morimoto K., and Suzuki H. Micro analysis system for pH and protease activities with an integrated sample injection mechanism. Biosens. Bioelectron. 22 (2006) 86-93
    • (2006) Biosens. Bioelectron. , vol.22 , pp. 86-93
    • Morimoto, K.1    Suzuki, H.2
  • 13
    • 34248556347 scopus 로고    scopus 로고
    • Electrochemical immunoassay on a microfluidic device with sequential injection and flushing functions
    • Nashida N., Satoh W., Fukuda J., and Suzuki H. Electrochemical immunoassay on a microfluidic device with sequential injection and flushing functions. Biosens. Bioelectron. 22 (2007) 3167-3173
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 3167-3173
    • Nashida, N.1    Satoh, W.2    Fukuda, J.3    Suzuki, H.4
  • 14
    • 60349089247 scopus 로고    scopus 로고
    • Electrowetting-bases pH- and biomolecule-responsive valves and pH filters
    • Yamaguchi S., Morimoto K., Fukuda J., and Suzuki H. Electrowetting-bases pH- and biomolecule-responsive valves and pH filters. Biosens. Bioelectron. 24 (2009) 2171-2176
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2171-2176
    • Yamaguchi, S.1    Morimoto, K.2    Fukuda, J.3    Suzuki, H.4
  • 15
    • 39449112427 scopus 로고    scopus 로고
    • Automatic electrochemical micro-pH-stat for biomicrosystems
    • Morimoto K., Toya M., Fukuda J., and Suzuki H. Automatic electrochemical micro-pH-stat for biomicrosystems. Anal. Chem. 80 (2008) 905-914
    • (2008) Anal. Chem. , vol.80 , pp. 905-914
    • Morimoto, K.1    Toya, M.2    Fukuda, J.3    Suzuki, H.4
  • 16
    • 1342285677 scopus 로고    scopus 로고
    • Microfabricated flow system for ammonia and creatinine with an air-gap structure
    • Suzuki H., and Matsugi Y. Microfabricated flow system for ammonia and creatinine with an air-gap structure. Sens. Actuators B 98 (2004) 101-111
    • (2004) Sens. Actuators B , vol.98 , pp. 101-111
    • Suzuki, H.1    Matsugi, Y.2
  • 17
    • 19744366758 scopus 로고    scopus 로고
    • Integrated microfluidic system for the simultaneous determination of ammonia, creatinine, and urea
    • Suzuki H., and Matsugi Y. Integrated microfluidic system for the simultaneous determination of ammonia, creatinine, and urea. Sens. Actuators B 108 (2005) 700-707
    • (2005) Sens. Actuators B , vol.108 , pp. 700-707
    • Suzuki, H.1    Matsugi, Y.2
  • 18
    • 27544484426 scopus 로고    scopus 로고
    • On-chip microfluidic transport and mixing using electrowetting and incorporation of sensing functions
    • Satoh W., Hosono H., and Suzuki H. On-chip microfluidic transport and mixing using electrowetting and incorporation of sensing functions. Anal. Chem. 77 (2005) 6857-6863
    • (2005) Anal. Chem. , vol.77 , pp. 6857-6863
    • Satoh, W.1    Hosono, H.2    Suzuki, H.3
  • 19
    • 57449111474 scopus 로고    scopus 로고
    • On-chip culturing of hepatocytes and monitoring their ammonia metabolism
    • Satoh W., Takahashi S., Sassa F., Fukuda J., and Suzuki H. On-chip culturing of hepatocytes and monitoring their ammonia metabolism. Lab Chip 9 (2009) 35-37
    • (2009) Lab Chip , vol.9 , pp. 35-37
    • Satoh, W.1    Takahashi, S.2    Sassa, F.3    Fukuda, J.4    Suzuki, H.5
  • 20
    • 0033636794 scopus 로고    scopus 로고
    • Micropatterned solid-supported membranes formed by micromolding in capillaries
    • Janshoff A., and Künneke S. Micropatterned solid-supported membranes formed by micromolding in capillaries. Eur. Biophys. J. 29 (2000) 549-554
    • (2000) Eur. Biophys. J. , vol.29 , pp. 549-554
    • Janshoff, A.1    Künneke, S.2
  • 21
    • 0032573880 scopus 로고    scopus 로고
    • Microfluidic networks for chemical patterning of substrates: design and application to bioassays
    • Delamarche E., Bernard A., Schmid H., Bietsch A., Michel B., and Biebuyck H. Microfluidic networks for chemical patterning of substrates: design and application to bioassays. J. Am. Chem. Soc. 120 (1998) 500-508
    • (1998) J. Am. Chem. Soc. , vol.120 , pp. 500-508
    • Delamarche, E.1    Bernard, A.2    Schmid, H.3    Bietsch, A.4    Michel, B.5    Biebuyck, H.6
  • 22
    • 0029357345 scopus 로고
    • Polymer microstructures formed by molding in capillaries
    • Kim E., Xia Y., and Whitesides G.M. Polymer microstructures formed by molding in capillaries. Science 376 (1995) 581-584
    • (1995) Science , vol.376 , pp. 581-584
    • Kim, E.1    Xia, Y.2    Whitesides, G.M.3
  • 23
    • 0032259904 scopus 로고    scopus 로고
    • A novel Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes
    • Suzuki H., Ozawa H., Sasaki S., and Karube I. A novel Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes. Sens. Actuators B 53 (1998) 140-146
    • (1998) Sens. Actuators B , vol.53 , pp. 140-146
    • Suzuki, H.1    Ozawa, H.2    Sasaki, S.3    Karube, I.4
  • 24
    • 0033134740 scopus 로고    scopus 로고
    • Micromachined Severinghaus-type carbon dioxide electrode
    • Suzuki H., Arakawa H., Sasaki S., and Karube I. Micromachined Severinghaus-type carbon dioxide electrode. Anal. Chem. 71 (1999) 1737-1743
    • (1999) Anal. Chem. , vol.71 , pp. 1737-1743
    • Suzuki, H.1    Arakawa, H.2    Sasaki, S.3    Karube, I.4
  • 26
    • 0001391616 scopus 로고
    • A study of the diffusion of urea in water at 25° with the Gouy interference method
    • Gosting L.J., and Akeley D.F. A study of the diffusion of urea in water at 25° with the Gouy interference method. J. Am. Chem. Soc. 74 (1952) 2058-2060
    • (1952) J. Am. Chem. Soc. , vol.74 , pp. 2058-2060
    • Gosting, L.J.1    Akeley, D.F.2
  • 27
    • 0001672307 scopus 로고
    • A study of diffusion in the ternary system, labeled urea-urea-water, at 25° by measurements of the intradiffusion coefficients of urea
    • Albright J.G., and Mills R. A study of diffusion in the ternary system, labeled urea-urea-water, at 25° by measurements of the intradiffusion coefficients of urea. J. Phys. Chem. 69 (1965)
    • (1965) J. Phys. Chem. , vol.69
    • Albright, J.G.1    Mills, R.2
  • 28
    • 33947487658 scopus 로고
    • Tracer diffusion in binary solutions subject to a dimerization equilibrium
    • Stokes R.H. Tracer diffusion in binary solutions subject to a dimerization equilibrium. J. Phys. Chem. 69 (1965) 4012-4017
    • (1965) J. Phys. Chem. , vol.69 , pp. 4012-4017
    • Stokes, R.H.1
  • 29
    • 1042304396 scopus 로고    scopus 로고
    • The effect of temperature on urea-urea interactions in water: a molecular dynamics simulation
    • Idrissi A., Cinar E., Longelin S., and Damay P. The effect of temperature on urea-urea interactions in water: a molecular dynamics simulation. J. Mol. Liq. 110 (2004) 201-208
    • (2004) J. Mol. Liq. , vol.110 , pp. 201-208
    • Idrissi, A.1    Cinar, E.2    Longelin, S.3    Damay, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.