-
3
-
-
0028164254
-
Transducer aspects of biosensors
-
Sethi R. Transducer aspects of biosensors. Biosens. Bioelectron. 9 (1994) 243-264
-
(1994)
Biosens. Bioelectron.
, vol.9
, pp. 243-264
-
-
Sethi, R.1
-
5
-
-
0036179366
-
Some new aspects in biosensor
-
Dong S., and Chen X. Some new aspects in biosensor. Rev. Mol. Biotechnol. 82 (2002) 303-323
-
(2002)
Rev. Mol. Biotechnol.
, vol.82
, pp. 303-323
-
-
Dong, S.1
Chen, X.2
-
6
-
-
0032924588
-
Containment sensors for the determination of l-lactate and glucose
-
Perdomo J., Sundermeier C., Hinkers H., Martínez Morell O., Seifert W., and Knoll M. Containment sensors for the determination of l-lactate and glucose. Biosens. Bioelectron. 14 (1999) 27-32
-
(1999)
Biosens. Bioelectron.
, vol.14
, pp. 27-32
-
-
Perdomo, J.1
Sundermeier, C.2
Hinkers, H.3
Martínez Morell, O.4
Seifert, W.5
Knoll, M.6
-
7
-
-
0014191637
-
The enzyme electrode, a miniature chemical transducer using immobilized activity
-
Updick S.J., and Hicks G.P. The enzyme electrode, a miniature chemical transducer using immobilized activity. Nature 214 (1967) 986-988
-
(1967)
Nature
, vol.214
, pp. 986-988
-
-
Updick, S.J.1
Hicks, G.P.2
-
8
-
-
33947169146
-
-
L.C. Clark, Jr. Membrane polarographic electrode system and method with electrochemical compensation, U.S. Patent (1970) No. 3, 539455.
-
-
-
-
9
-
-
0020039886
-
A Miniature pH sensor potentially suitable for glucose measurements
-
Peterson J.I., et al. A Miniature pH sensor potentially suitable for glucose measurements. Diabetes Care 5 3 (1982) 272-274
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 272-274
-
-
Peterson, J.I.1
-
10
-
-
0033083347
-
SPR biosensor: simultaneously removing thermal and bulk-composition effects
-
Michael J., O' Brien I.I., Brueck S.R.J., Perez-Luna V.H., Tender L.M., and Lopez G.P. SPR biosensor: simultaneously removing thermal and bulk-composition effects. Biosens. Bioelectron. 14 (1999) 145-154
-
(1999)
Biosens. Bioelectron.
, vol.14
, pp. 145-154
-
-
Michael, J.1
O' Brien, I.I.2
Brueck, S.R.J.3
Perez-Luna, V.H.4
Tender, L.M.5
Lopez, G.P.6
-
11
-
-
0038094492
-
A glucose oxidase electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant
-
Sung W.J., and Bae Y.H. A glucose oxidase electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant. Biosens. Bioelectron. 18 (2003) 1231-1239
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 1231-1239
-
-
Sung, W.J.1
Bae, Y.H.2
-
12
-
-
2542475503
-
Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode
-
Li T., Yao Z., and Ding L. Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode. Sens. Actuators B: Chem. 101 (2004) 155-160
-
(2004)
Sens. Actuators B: Chem.
, vol.101
, pp. 155-160
-
-
Li, T.1
Yao, Z.2
Ding, L.3
-
13
-
-
0242486387
-
Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane
-
Yu J., Liu S., and Ju H. Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane. Biosens. Bioelectron. 19 (2003) 401-409
-
(2003)
Biosens. Bioelectron.
, vol.19
, pp. 401-409
-
-
Yu, J.1
Liu, S.2
Ju, H.3
-
14
-
-
33947173072
-
Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices
-
Lin C.F., Lee G.B., Wang C.H., Lee H.H., Liao W.Y., and Chou T.C. Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices. Biosens. Bioelectron. 21 (2005) 419-425
-
(2005)
Biosens. Bioelectron.
, vol.21
, pp. 419-425
-
-
Lin, C.F.1
Lee, G.B.2
Wang, C.H.3
Lee, H.H.4
Liao, W.Y.5
Chou, T.C.6
-
15
-
-
0037086387
-
A disposable intelligent mosquito with a reversible sampling mechanism using the volume-phase transition of a gel
-
Suzuki H., Tokuda T., and Kobayashi K. A disposable intelligent mosquito with a reversible sampling mechanism using the volume-phase transition of a gel. Sens. Actuators B: Chem. 83 (2002) 53-59
-
(2002)
Sens. Actuators B: Chem.
, vol.83
, pp. 53-59
-
-
Suzuki, H.1
Tokuda, T.2
Kobayashi, K.3
-
16
-
-
0030655168
-
A micro-planar amperometric glucose sensor unsusceptible to interference species
-
Matsumoto T., Furusawa M., Fujiwara H., Matsumoto Y., and Ito N. A micro-planar amperometric glucose sensor unsusceptible to interference species. Proceedings of The Ninth International Conference on Solid-state Sensors, Actuators, and Microsystems (Transducers) (1997) 903-906
-
(1997)
Proceedings of The Ninth International Conference on Solid-state Sensors, Actuators, and Microsystems (Transducers)
, pp. 903-906
-
-
Matsumoto, T.1
Furusawa, M.2
Fujiwara, H.3
Matsumoto, Y.4
Ito, N.5
-
19
-
-
10044265053
-
micromachined polymerase chain reaction system for multiple DNA amplification on upper-respiratory tract infectious diseases
-
Liao C.S., Lee G.B., Wu J.J., Chang C.C., Hsieh T.M., and Luo C.H. micromachined polymerase chain reaction system for multiple DNA amplification on upper-respiratory tract infectious diseases. Biosens. Bioelectron. 20 (2005) 1341-1348
-
(2005)
Biosens. Bioelectron.
, vol.20
, pp. 1341-1348
-
-
Liao, C.S.1
Lee, G.B.2
Wu, J.J.3
Chang, C.C.4
Hsieh, T.M.5
Luo, C.H.6
-
20
-
-
0032746841
-
Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays
-
Duffy D.C., Gillis H.L., Lin J., Sheppard Jr. N.F., and Kellogg G.J. Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays. Anal. Chem. 71 (1999) 4669-4698
-
(1999)
Anal. Chem.
, vol.71
, pp. 4669-4698
-
-
Duffy, D.C.1
Gillis, H.L.2
Lin, J.3
Sheppard Jr., N.F.4
Kellogg, G.J.5
-
21
-
-
31444437947
-
Pneumatic-driven peristaltic micropumps utilizing serpentine-shape channels
-
Wang C.H., and Lee G.B. Pneumatic-driven peristaltic micropumps utilizing serpentine-shape channels. J. Micromech. Microeng. 16 (2006) 341-348
-
(2006)
J. Micromech. Microeng.
, vol.16
, pp. 341-348
-
-
Wang, C.H.1
Lee, G.B.2
-
22
-
-
23144452296
-
Automatic bio-samplings chips integrated with micro-pumps and micro-valves for disease detection
-
Wang C.H., and Lee G.B. Automatic bio-samplings chips integrated with micro-pumps and micro-valves for disease detection. Biosens. Bioelectron. 21 (2005) 419-425
-
(2005)
Biosens. Bioelectron.
, vol.21
, pp. 419-425
-
-
Wang, C.H.1
Lee, G.B.2
-
23
-
-
0033051709
-
Performance of subcutaneously implanted glucose sensors for continuous monitoring
-
Gerritsen M., Jansen J.A., and Lutterman J.A. Performance of subcutaneously implanted glucose sensors for continuous monitoring. Neth. J. Med. 54 (1999) 167-179
-
(1999)
Neth. J. Med.
, vol.54
, pp. 167-179
-
-
Gerritsen, M.1
Jansen, J.A.2
Lutterman, J.A.3
-
24
-
-
27544504429
-
A microfluidic chip integrated with molecular imprinting polymers for surface plasmon resonance detection
-
June 5-9
-
Huang S.C., Chien F.C., Lin J.S., Chen S.J., Chen W.J., and Lee G.B. A microfluidic chip integrated with molecular imprinting polymers for surface plasmon resonance detection. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems. June 5-9 (2005)
-
(2005)
The 13th International Conference on Solid-State Sensors, Actuators and Microsystems
-
-
Huang, S.C.1
Chien, F.C.2
Lin, J.S.3
Chen, S.J.4
Chen, W.J.5
Lee, G.B.6
-
25
-
-
0242637456
-
Fabrication of the galvanostatic polypyrrole/glucose oxidase biosensor in various pH aqueous solutions
-
Uang Y.M., and Chou T.C. Fabrication of the galvanostatic polypyrrole/glucose oxidase biosensor in various pH aqueous solutions. Biosens. Bioelectron. 19 (2004) 141-147
-
(2004)
Biosens. Bioelectron.
, vol.19
, pp. 141-147
-
-
Uang, Y.M.1
Chou, T.C.2
-
26
-
-
18744404791
-
Integrated microfluidic system for DNA amplification
-
Lee C.-Y., Lee G.-B., Lin J.-L., Huang F.-C., and Liao C.-S. Integrated microfluidic system for DNA amplification. J. Micromech. Microeng. 15 (2005) 1215-1223
-
(2005)
J. Micromech. Microeng.
, vol.15
, pp. 1215-1223
-
-
Lee, C.-Y.1
Lee, G.-B.2
Lin, J.-L.3
Huang, F.-C.4
Liao, C.-S.5
|