메뉴 건너뛰기




Volumn 31, Issue 7, 2009, Pages 742-751

Cardiovascular cavitation

Author keywords

Cavitation; Gas embolotherapy; Laser surgery; Mechanical heart valves; Ultrasound surgery

Indexed keywords

BIOEFFECTS OF ULTRASOUND; CAVITATION BUBBLE; CAVITATION EFFECT; COLLATERAL DAMAGE; FREE RADICAL SPECIES; GAS EMBOLOTHERAPY; HIGH VELOCITY; LASER FOCUS; LIQUID ENVIRONMENT; LIQUID JETS; MECHANICAL HEART VALVES; PHYSICAL MECHANISM; PULSED LASER; SHEAR FORCE; SURGICAL TECHNIQUES; THERAPEUTIC APPLICATION; TISSUE STRUCTURE; ULTRASOUND SURGERY;

EID: 68349100164     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2009.03.007     Document Type: Review
Times cited : (30)

References (136)
  • 1
    • 8644277187 scopus 로고    scopus 로고
    • Ultrasound energy and the dissolution of thrombus
    • Polak J.F. Ultrasound energy and the dissolution of thrombus. N Engl J Med 351 (2004) 2154-2155
    • (2004) N Engl J Med , vol.351 , pp. 2154-2155
    • Polak, J.F.1
  • 2
    • 0034281748 scopus 로고    scopus 로고
    • Cavitational mechanisms in ultrasound-accelerated thrombolysis at 1 MHz
    • Everbach E.C., and Francis C.W. Cavitational mechanisms in ultrasound-accelerated thrombolysis at 1 MHz. Ultrasound Med Biol 26 (2000) 1153-1160
    • (2000) Ultrasound Med Biol , vol.26 , pp. 1153-1160
    • Everbach, E.C.1    Francis, C.W.2
  • 3
    • 0028158578 scopus 로고
    • Coronary ultrasound thrombolysis in a patient with acute myocardial infarction
    • Hamm C.W., Reimers J., Köster R., Terres W., Stiel G.M., Koschyk D.H., et al. Coronary ultrasound thrombolysis in a patient with acute myocardial infarction. Lancet 343 (1994) 605-606
    • (1994) Lancet , vol.343 , pp. 605-606
    • Hamm, C.W.1    Reimers, J.2    Köster, R.3    Terres, W.4    Stiel, G.M.5    Koschyk, D.H.6
  • 4
    • 0033547824 scopus 로고    scopus 로고
    • Percutaneous transluminal therapy of occluded saphenous vein grafts: can the challenge be met with ultrasound thrombolysis?
    • Rosenschein U., Gaul G., Erbel R., Amann F., Velasquez D., Stoerger H., et al. Percutaneous transluminal therapy of occluded saphenous vein grafts: can the challenge be met with ultrasound thrombolysis?. Circulation 99 (1999) 26
    • (1999) Circulation , vol.99 , pp. 26
    • Rosenschein, U.1    Gaul, G.2    Erbel, R.3    Amann, F.4    Velasquez, D.5    Stoerger, H.6
  • 5
    • 0029120590 scopus 로고
    • Activated-guidewire technique for treating chronic coronary artery occlusion
    • Rees M.R., and Michalis L.K. Activated-guidewire technique for treating chronic coronary artery occlusion. Lancet 346 (1995) 943-944
    • (1995) Lancet , vol.346 , pp. 943-944
    • Rees, M.R.1    Michalis, L.K.2
  • 8
    • 0029956720 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: reliable safe and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent
    • Meza M., Greener Y., Hunt R., Perry B., Revall S., Barbee W., et al. Myocardial contrast echocardiography: reliable safe and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent. Am Heart J 132 (1996) 871-881
    • (1996) Am Heart J , vol.132 , pp. 871-881
    • Meza, M.1    Greener, Y.2    Hunt, R.3    Perry, B.4    Revall, S.5    Barbee, W.6
  • 9
    • 0036228750 scopus 로고    scopus 로고
    • Physical correlates of the ultrasonic reflectivity of lipid dispersions suitable as diagnostic contrast agents
    • Huang S.L., Hamilton A.J., Pozharski E., Nagaraj A., Klegerman M.E., McPherson D.D., et al. Physical correlates of the ultrasonic reflectivity of lipid dispersions suitable as diagnostic contrast agents. Ultrasound Med Biol 28 (2002) 339-348
    • (2002) Ultrasound Med Biol , vol.28 , pp. 339-348
    • Huang, S.L.1    Hamilton, A.J.2    Pozharski, E.3    Nagaraj, A.4    Klegerman, M.E.5    McPherson, D.D.6
  • 10
    • 0014327602 scopus 로고
    • Echocardiography of the aortic root
    • Gramiak R., and Shah P.M. Echocardiography of the aortic root. Invest Radiol 3 (1968) 356-366
    • (1968) Invest Radiol , vol.3 , pp. 356-366
    • Gramiak, R.1    Shah, P.M.2
  • 12
    • 0031987373 scopus 로고    scopus 로고
    • On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent
    • Bouakaz A., de Jong N., Cachard C., and Jouini K. On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent. Ultrasonics 36 (1998) 703-708
    • (1998) Ultrasonics , vol.36 , pp. 703-708
    • Bouakaz, A.1    de Jong, N.2    Cachard, C.3    Jouini, K.4
  • 13
    • 0034872356 scopus 로고    scopus 로고
    • Myocardial contrast agents: recent advances and future directions
    • Mayer S., and Grayburn P.A. Myocardial contrast agents: recent advances and future directions. Prog Cardiovasc Dis 44 (2001) 33-44
    • (2001) Prog Cardiovasc Dis , vol.44 , pp. 33-44
    • Mayer, S.1    Grayburn, P.A.2
  • 14
    • 0023218358 scopus 로고
    • Successful left ventricular opacification following peripheral venous injection of sonicated contrast agent: an experimental evaluation
    • Keller M.W., Feinstein S.B., and Watson D.D. Successful left ventricular opacification following peripheral venous injection of sonicated contrast agent: an experimental evaluation. Am Heart J 114 (1987) 570-575
    • (1987) Am Heart J , vol.114 , pp. 570-575
    • Keller, M.W.1    Feinstein, S.B.2    Watson, D.D.3
  • 15
    • 0037131960 scopus 로고    scopus 로고
    • Physical principles of microbubble ultrasound contrast agents
    • Raisinghani A., and DeMaria A.N. Physical principles of microbubble ultrasound contrast agents. Am J Cardiol 90 (2002) 3J-7J
    • (2002) Am J Cardiol , vol.90
    • Raisinghani, A.1    DeMaria, A.N.2
  • 16
    • 33745924402 scopus 로고    scopus 로고
    • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications
    • Klibanov A.L. Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications. Invest Radiol 41 (2006) 354-362
    • (2006) Invest Radiol , vol.41 , pp. 354-362
    • Klibanov, A.L.1
  • 18
    • 0030877547 scopus 로고    scopus 로고
    • Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent
    • Firschke C., Lindner J.R., Wei K., Goodman N.C., Skyba D.M., and Kaul S. Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent. Circulation 96 (1997) 959-967
    • (1997) Circulation , vol.96 , pp. 959-967
    • Firschke, C.1    Lindner, J.R.2    Wei, K.3    Goodman, N.C.4    Skyba, D.M.5    Kaul, S.6
  • 19
    • 0033980281 scopus 로고    scopus 로고
    • Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast
    • Burns P.N., Wilson S.R., and Simpson D.H. Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast. Invest Radiol 35 (2000) 58-71
    • (2000) Invest Radiol , vol.35 , pp. 58-71
    • Burns, P.N.1    Wilson, S.R.2    Simpson, D.H.3
  • 20
    • 24144472991 scopus 로고    scopus 로고
    • Contrast-enhanced sonography for the characterization of hepatocellular carcinomas-correlation with histological differentiation
    • Strobel D., Kleinecke C., Hansler J., Frieser M., Handl T., Hahn E.G., et al. Contrast-enhanced sonography for the characterization of hepatocellular carcinomas-correlation with histological differentiation. Ultraschall Med 26 (2005) 270-276
    • (2005) Ultraschall Med , vol.26 , pp. 270-276
    • Strobel, D.1    Kleinecke, C.2    Hansler, J.3    Frieser, M.4    Handl, T.5    Hahn, E.G.6
  • 22
    • 0035471033 scopus 로고    scopus 로고
    • Generation of ultraharmonics in surfactant based ultrasound contrast agents: use and advantages
    • Basude R., and Wheatley M.A. Generation of ultraharmonics in surfactant based ultrasound contrast agents: use and advantages. Ultrasonics 39 (2001) 437-444
    • (2001) Ultrasonics , vol.39 , pp. 437-444
    • Basude, R.1    Wheatley, M.A.2
  • 23
    • 0035182763 scopus 로고    scopus 로고
    • Contrast dobutamine stress echocardiography: clinical practice assessment in 300 consecutive patients
    • Rainbird A.J., Mulvagh S.L., Oh J.K., McCully R.B., Klarich K.W., Shub C., et al. Contrast dobutamine stress echocardiography: clinical practice assessment in 300 consecutive patients. J Am Soc Echocardiogr (2001) 14378-14385
    • (2001) J Am Soc Echocardiogr , pp. 14378-14385
    • Rainbird, A.J.1    Mulvagh, S.L.2    Oh, J.K.3    McCully, R.B.4    Klarich, K.W.5    Shub, C.6
  • 26
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound induced destruction of microbubbles administrated as a contrast venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Quantification of myocardial blood flow with ultrasound induced destruction of microbubbles administrated as a contrast venous infusion. Circulation 97 (1998) 473-483
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 27
    • 0035205826 scopus 로고    scopus 로고
    • Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography
    • Leong-Poi H., Le E., Rim S.J., Sakuma T., Kaul S., and Wei K. Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography. J Am Soc Echocardiogr 14 (2001) 1173-1182
    • (2001) J Am Soc Echocardiogr , vol.14 , pp. 1173-1182
    • Leong-Poi, H.1    Le, E.2    Rim, S.J.3    Sakuma, T.4    Kaul, S.5    Wei, K.6
  • 28
    • 27744515267 scopus 로고    scopus 로고
    • Cardioprotective effects of the novel selective endothelin-A receptor antagonist BSF 461314 in ischemia-reperfusion injury
    • Hansen A., Bekeredjian R., Filusch A., Wolf D., Gross M.L., Mueller S., et al. Cardioprotective effects of the novel selective endothelin-A receptor antagonist BSF 461314 in ischemia-reperfusion injury. J Am Soc Echocardiogr 18 (2005) 1213-1220
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1213-1220
    • Hansen, A.1    Bekeredjian, R.2    Filusch, A.3    Wolf, D.4    Gross, M.L.5    Mueller, S.6
  • 29
    • 0034865723 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: basic principles
    • Kaul S. Myocardial contrast echocardiography: basic principles. Prog Cardiovasc Dis 44 (2001) 1-11
    • (2001) Prog Cardiovasc Dis , vol.44 , pp. 1-11
    • Kaul, S.1
  • 32
    • 3042544619 scopus 로고    scopus 로고
    • Microbubbles in medical imaging: current applications and future directions
    • Lindner J.R. Microbubbles in medical imaging: current applications and future directions. Nat Rev Drug Discov 3 (2004) 527-532
    • (2004) Nat Rev Drug Discov , vol.3 , pp. 527-532
    • Lindner, J.R.1
  • 33
    • 0034612205 scopus 로고    scopus 로고
    • Echocardiographic destruction of albumin micro-bubbles directs gene delivery to the myocardium
    • Shohet R.V., Chen S., Zhou Y.T., Wang Z., Meidell R.S., Unger R.H., et al. Echocardiographic destruction of albumin micro-bubbles directs gene delivery to the myocardium. Circulation 101 (2000) 2554-2556
    • (2000) Circulation , vol.101 , pp. 2554-2556
    • Shohet, R.V.1    Chen, S.2    Zhou, Y.T.3    Wang, Z.4    Meidell, R.S.5    Unger, R.H.6
  • 34
    • 0037215799 scopus 로고    scopus 로고
    • Ultrasound-targeted antisense oligonucleotide attenuates ischemia/reperfusion-induced myocardial tumor necrosis factor-alpha
    • Erikson J.M., Freeman G.L., and Chandrasekar B. Ultrasound-targeted antisense oligonucleotide attenuates ischemia/reperfusion-induced myocardial tumor necrosis factor-alpha. J Mol Cell Cardiol 35 (2003) 119-130
    • (2003) J Mol Cell Cardiol , vol.35 , pp. 119-130
    • Erikson, J.M.1    Freeman, G.L.2    Chandrasekar, B.3
  • 37
    • 0141426729 scopus 로고    scopus 로고
    • Optimization of ultrasound-mediated gene transfer: comparison of contrast agents and ultrasound modalities
    • Pislaru S.V., Pislaru C., Kinnick R.R., Singh R., Gulati R., Greenleaf J.F., et al. Optimization of ultrasound-mediated gene transfer: comparison of contrast agents and ultrasound modalities. Eur Heart J 24 (2003) 1690-1698
    • (2003) Eur Heart J , vol.24 , pp. 1690-1698
    • Pislaru, S.V.1    Pislaru, C.2    Kinnick, R.R.3    Singh, R.4    Gulati, R.5    Greenleaf, J.F.6
  • 38
    • 0037138499 scopus 로고    scopus 로고
    • Influence of injection site microvascular pressure and ultrasound variables on microbubble-mediated delivery of microspheres to muscle
    • Song J., Chappell J.C., Qi M., VanGieson E.J., Kaul S., and Price R.J. Influence of injection site microvascular pressure and ultrasound variables on microbubble-mediated delivery of microspheres to muscle. J Am Coll Cardiol 39 (2002) 726-731
    • (2002) J Am Coll Cardiol , vol.39 , pp. 726-731
    • Song, J.1    Chappell, J.C.2    Qi, M.3    VanGieson, E.J.4    Kaul, S.5    Price, R.J.6
  • 39
    • 4043055869 scopus 로고    scopus 로고
    • Treatment of acute myocardial infarction by hepatocyte growth factor gene transfer: the first demonstration of myocardial transfer of a "functional" gene using ultrasonic microbubble destruction
    • Kondo I., Ohmori K., Oshita A., Takeuchi H., Fuke S., Shinomiya K., et al. Treatment of acute myocardial infarction by hepatocyte growth factor gene transfer: the first demonstration of myocardial transfer of a "functional" gene using ultrasonic microbubble destruction. J Am Coll Cardiol 44 (2004) 644-653
    • (2004) J Am Coll Cardiol , vol.44 , pp. 644-653
    • Kondo, I.1    Ohmori, K.2    Oshita, A.3    Takeuchi, H.4    Fuke, S.5    Shinomiya, K.6
  • 41
    • 11144356848 scopus 로고    scopus 로고
    • Local delivery of E2F decoy oligodeoxynucleotides using ultrasound with microbubble agent (Optison) inhibits intimal hyperplasia after balloon injury in rat carotid artery model
    • Hashiya N., Aoki M., Tachibana K., Taniyama Y., Yamasaki K., Hiraoka K., et al. Local delivery of E2F decoy oligodeoxynucleotides using ultrasound with microbubble agent (Optison) inhibits intimal hyperplasia after balloon injury in rat carotid artery model. Biochem Biophys Res Commun 317 (2004) 508-514
    • (2004) Biochem Biophys Res Commun , vol.317 , pp. 508-514
    • Hashiya, N.1    Aoki, M.2    Tachibana, K.3    Taniyama, Y.4    Yamasaki, K.5    Hiraoka, K.6
  • 42
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K., McDannold N., Vykhodtseva N., and Jolesz F. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 220 (2001) 640-646
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.4
  • 43
    • 0034124257 scopus 로고    scopus 로고
    • Ten-fold augmentation of endothelial uptake of vascular endothelial growth factor with ultrasound after systemic administration
    • Mukherjee D., Wong J., Griffin B., Ellis S.G., Porter T., Sen S., et al. Ten-fold augmentation of endothelial uptake of vascular endothelial growth factor with ultrasound after systemic administration. J Am Coll Cardiol 35 (2000) 1678-1686
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1678-1686
    • Mukherjee, D.1    Wong, J.2    Griffin, B.3    Ellis, S.G.4    Porter, T.5    Sen, S.6
  • 44
    • 13244274387 scopus 로고    scopus 로고
    • Augmentation of cardiac protein delivery using ultrasound targeted microbubble destruction
    • Bekeredjian R., Chen S., Grayburn P.A., and Shohet R.V. Augmentation of cardiac protein delivery using ultrasound targeted microbubble destruction. Ultrasound Med Biol 31 (2005) 687-691
    • (2005) Ultrasound Med Biol , vol.31 , pp. 687-691
    • Bekeredjian, R.1    Chen, S.2    Grayburn, P.A.3    Shohet, R.V.4
  • 45
    • 2542474789 scopus 로고    scopus 로고
    • Induction of angiogenesis in a canine model of chronic myocardial ischemia with intravenous infusion of vascular endothelial growth factor (VEGF) combined with ultrasound energy and echo contrast agent
    • Zhou Z., Mukherjee D., Wang K., Zhou X., Tarakji K., Ellis K., et al. Induction of angiogenesis in a canine model of chronic myocardial ischemia with intravenous infusion of vascular endothelial growth factor (VEGF) combined with ultrasound energy and echo contrast agent. J Am Coll Cardiol 39 (2002) 396
    • (2002) J Am Coll Cardiol , vol.39 , pp. 396
    • Zhou, Z.1    Mukherjee, D.2    Wang, K.3    Zhou, X.4    Tarakji, K.5    Ellis, K.6
  • 46
    • 8644262429 scopus 로고    scopus 로고
    • Ultrasound-mediated microbubble destruction enhances VEGF gene delivery to the infarcted myocardium in rats
    • Zhigang W., Zhiyu L., Haitao R., Hong R., Qunxia Z., Ailong H., et al. Ultrasound-mediated microbubble destruction enhances VEGF gene delivery to the infarcted myocardium in rats. Clin Imaging 28 (2004) 395-398
    • (2004) Clin Imaging , vol.28 , pp. 395-398
    • Zhigang, W.1    Zhiyu, L.2    Haitao, R.3    Hong, R.4    Qunxia, Z.5    Ailong, H.6
  • 48
  • 53
    • 14744278053 scopus 로고    scopus 로고
    • High-speed optical observations of contrast agent destruction
    • Bouakaz A., Versluis M., and de Jong N. High-speed optical observations of contrast agent destruction. Ultrasound Med Biol 31 (2005) 391-399
    • (2005) Ultrasound Med Biol , vol.31 , pp. 391-399
    • Bouakaz, A.1    Versluis, M.2    de Jong, N.3
  • 55
    • 1242329827 scopus 로고    scopus 로고
    • Optical observation of lipid- and polymer-shelled ultrasound microbubble contrast agents
    • Bloch S.H., Wan M., Dayton P.A., and Ferrara K.W. Optical observation of lipid- and polymer-shelled ultrasound microbubble contrast agents. Appl Phys Lett 84 (2004) 631-633
    • (2004) Appl Phys Lett , vol.84 , pp. 631-633
    • Bloch, S.H.1    Wan, M.2    Dayton, P.A.3    Ferrara, K.W.4
  • 56
    • 36849093332 scopus 로고    scopus 로고
    • Ultrasound-driven microbubble oscillation and translation within small phantom vessels
    • Zheng H., Dayton P.A., Caskey C., Zhao S., Qin S., and Ferrara K.W. Ultrasound-driven microbubble oscillation and translation within small phantom vessels. Ultrasound Med Biol 33 (2007) 1978-1987
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1978-1987
    • Zheng, H.1    Dayton, P.A.2    Caskey, C.3    Zhao, S.4    Qin, S.5    Ferrara, K.W.6
  • 57
    • 0034340540 scopus 로고    scopus 로고
    • Collapse of cavitation bubbles in blood
    • Brujan E.A. Collapse of cavitation bubbles in blood. Europhys Lett 50 (2000) 175-181
    • (2000) Europhys Lett , vol.50 , pp. 175-181
    • Brujan, E.A.1
  • 59
    • 1842455119 scopus 로고    scopus 로고
    • The role of cavitation microjets in the therapeutic applications of ultrasound
    • Brujan E.A. The role of cavitation microjets in the therapeutic applications of ultrasound. Ultrasound Med Biol 30 (2004) 381-387
    • (2004) Ultrasound Med Biol , vol.30 , pp. 381-387
    • Brujan, E.A.1
  • 60
    • 26244451367 scopus 로고    scopus 로고
    • Jet formation and shock wave emission during collapse of ultrasound-induced cavitation bubbles and their role in the therapeutic applications of high-intensity focused ultrasound
    • Brujan E.A., Ikeda T., and Matsumoto Y. Jet formation and shock wave emission during collapse of ultrasound-induced cavitation bubbles and their role in the therapeutic applications of high-intensity focused ultrasound. Phys Med Biol 50 (2005) 4797-4809
    • (2005) Phys Med Biol , vol.50 , pp. 4797-4809
    • Brujan, E.A.1    Ikeda, T.2    Matsumoto, Y.3
  • 63
    • 0032005569 scopus 로고    scopus 로고
    • Temperature rise generated by ultrasound in the presence of contrast agent
    • Wu J. Temperature rise generated by ultrasound in the presence of contrast agent. Ultrasound Med Biol 24 (1998) 267-274
    • (1998) Ultrasound Med Biol , vol.24 , pp. 267-274
    • Wu, J.1
  • 64
    • 0032171442 scopus 로고    scopus 로고
    • Effect of gas-containing microspheres and echo contrast agents on free radical formation by ultrasound
    • Kondo T., Misik V., and Riesz P. Effect of gas-containing microspheres and echo contrast agents on free radical formation by ultrasound. Free Radic Biol Med 25 (1998) 605-612
    • (1998) Free Radic Biol Med , vol.25 , pp. 605-612
    • Kondo, T.1    Misik, V.2    Riesz, P.3
  • 65
    • 0037401170 scopus 로고    scopus 로고
    • In vitro modulation of intracellular oxidative stress of endothelial cells by diagnostic cardiac ultrasound
    • Basta G., Venneri L., Lazzerini G., Pasanisi E., Pianelli M., Vesentini N., et al. In vitro modulation of intracellular oxidative stress of endothelial cells by diagnostic cardiac ultrasound. Cardiovasc Res 58 (2003) 156-161
    • (2003) Cardiovasc Res , vol.58 , pp. 156-161
    • Basta, G.1    Venneri, L.2    Lazzerini, G.3    Pasanisi, E.4    Pianelli, M.5    Vesentini, N.6
  • 68
    • 0038062983 scopus 로고    scopus 로고
    • Nonlinear behaviors of contrast agents relevant to diagnostic and therapeutic applications
    • Wu J., Pepe J., and Dewitt W. Nonlinear behaviors of contrast agents relevant to diagnostic and therapeutic applications. Ultrasound Med Biol 29 (2003) 555-562
    • (2003) Ultrasound Med Biol , vol.29 , pp. 555-562
    • Wu, J.1    Pepe, J.2    Dewitt, W.3
  • 69
  • 72
    • 0033619173 scopus 로고    scopus 로고
    • Transmyocardial laser revascularisation
    • Lange R.A., and Hillis L.D. Transmyocardial laser revascularisation. N Engl J Med 341 (1999) 1075-1076
    • (1999) N Engl J Med , vol.341 , pp. 1075-1076
    • Lange, R.A.1    Hillis, L.D.2
  • 73
    • 0029928186 scopus 로고    scopus 로고
    • Transmyocardial laser revascularisation: operative techniques and clinical results at two years
    • Horvath K.A., Manning F., Cummings N., Shernan S.K., and Cohn L.H. Transmyocardial laser revascularisation: operative techniques and clinical results at two years. J Thorac Cardiovasc Surg 111 (1996) 1047-1053
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 1047-1053
    • Horvath, K.A.1    Manning, F.2    Cummings, N.3    Shernan, S.K.4    Cohn, L.H.5
  • 75
    • 0037326694 scopus 로고    scopus 로고
    • Mechanisms of pulsed laser ablation of biological tissues
    • Vogel A., and Venugopalan V. Mechanisms of pulsed laser ablation of biological tissues. Chem Rev 103 (2003) 577-644
    • (2003) Chem Rev , vol.103 , pp. 577-644
    • Vogel, A.1    Venugopalan, V.2
  • 76
    • 0026680326 scopus 로고
    • Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig
    • Van Leeuwen T.G., van Erven L., Meerten J.H., Motamedi M., Post M.J., and Borst C. Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. J Am Coll Cardiol 19 (1992) 1610-1618
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1610-1618
    • Van Leeuwen, T.G.1    van Erven, L.2    Meerten, J.H.3    Motamedi, M.4    Post, M.J.5    Borst, C.6
  • 77
    • 0035946478 scopus 로고    scopus 로고
    • Dynamics of laser-induced cavitation bubbles near an elastic boundary
    • Brujan E.A., Nahen K., Schmidt P., and Vogel A. Dynamics of laser-induced cavitation bubbles near an elastic boundary. J Fluid Mech 433 (2001) 251-281
    • (2001) J Fluid Mech , vol.433 , pp. 251-281
    • Brujan, E.A.1    Nahen, K.2    Schmidt, P.3    Vogel, A.4
  • 78
    • 0035946577 scopus 로고    scopus 로고
    • Dynamics of laser-induced cavitation bubbles near elastic boundaries: influence of the elastic modulus
    • Brujan E.A., Nahen K., Schmidt P., and Vogel A. Dynamics of laser-induced cavitation bubbles near elastic boundaries: influence of the elastic modulus. J Fluid Mech 433 (2001) 283-314
    • (2001) J Fluid Mech , vol.433 , pp. 283-314
    • Brujan, E.A.1    Nahen, K.2    Schmidt, P.3    Vogel, A.4
  • 79
    • 33745698878 scopus 로고    scopus 로고
    • Stress wave emission and cavitation bubble dynamics by nanosecond optical breakdown in a tissue phantom
    • Brujan E.A., and Vogel A. Stress wave emission and cavitation bubble dynamics by nanosecond optical breakdown in a tissue phantom. J Fluid Mech 558 (2006) 281-308
    • (2006) J Fluid Mech , vol.558 , pp. 281-308
    • Brujan, E.A.1    Vogel, A.2
  • 82
    • 3042739347 scopus 로고    scopus 로고
    • Strategies for the reduction of cerebral microembolism during transmyocardial laser revascularisation
    • Gerriets T., Grossherr M., Misfeld M., Nees U., Reusche E., Stolz E., et al. Strategies for the reduction of cerebral microembolism during transmyocardial laser revascularisation. Laser Surg Med 34 (2004) 79-384
    • (2004) Laser Surg Med , vol.34 , pp. 79-384
    • Gerriets, T.1    Grossherr, M.2    Misfeld, M.3    Nees, U.4    Reusche, E.5    Stolz, E.6
  • 83
    • 0029911150 scopus 로고    scopus 로고
    • Advances in coronary angioplasty
    • Bittl J.A. Advances in coronary angioplasty. N Engl J Med 335 (1996) 1290-1302
    • (1996) N Engl J Med , vol.335 , pp. 1290-1302
    • Bittl, J.A.1
  • 85
    • 0025737348 scopus 로고
    • Ultrasonic angioplasty in totally occluded peripheral arteries Initial clinical histological and angiographic results
    • Rosenschein U., Rozenzsajn L.A., Kraus L., Marboe C.C., Watkins J.F., Rose E.A., et al. Ultrasonic angioplasty in totally occluded peripheral arteries Initial clinical histological and angiographic results. Circulation 83 (1991) 1976-1986
    • (1991) Circulation , vol.83 , pp. 1976-1986
    • Rosenschein, U.1    Rozenzsajn, L.A.2    Kraus, L.3    Marboe, C.C.4    Watkins, J.F.5    Rose, E.A.6
  • 86
    • 0026763940 scopus 로고
    • Excimer coronary laser angioplasty-its time for a critical evaluation
    • Lee G., and Mason D.T. Excimer coronary laser angioplasty-its time for a critical evaluation. Am J Cardiol 69 (1992) 1640-1643
    • (1992) Am J Cardiol , vol.69 , pp. 1640-1643
    • Lee, G.1    Mason, D.T.2
  • 87
    • 0027199103 scopus 로고
    • Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries
    • Safian R.D., Niazi K.A., Strzelecki M., Lichtenberg A., May M.A., Juran N., et al. Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries. Circulation 88 (1993) 961-968
    • (1993) Circulation , vol.88 , pp. 961-968
    • Safian, R.D.1    Niazi, K.A.2    Strzelecki, M.3    Lichtenberg, A.4    May, M.A.5    Juran, N.6
  • 88
    • 0026042557 scopus 로고
    • High intensity ultrasound increases distensibility of calcific atherosclerotic arteries
    • Demer L.L., Ariani M., and Siegel R.J. High intensity ultrasound increases distensibility of calcific atherosclerotic arteries. J Am Coll Cardiol 18 (1991) 1259-1262
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1259-1262
    • Demer, L.L.1    Ariani, M.2    Siegel, R.J.3
  • 89
  • 90
    • 13344295081 scopus 로고    scopus 로고
    • Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease
    • Appelman Y.E.A., Piek J.J., Strikwerda S., Tijssen J.G.P., de Feyter P.J., David G.K., et al. Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease. Lancet 347 (1996) 79-84
    • (1996) Lancet , vol.347 , pp. 79-84
    • Appelman, Y.E.A.1    Piek, J.J.2    Strikwerda, S.3    Tijssen, J.G.P.4    de Feyter, P.J.5    David, G.K.6
  • 91
    • 0028809765 scopus 로고
    • Mechanisms of lumen enlargement after excimer laser coronary angioplasty: an intravascular ultrasound study
    • Mintz G.S., Kovach J.A., Javier S.P., Pichard A.D., Kent K.M., Popma J.J., et al. Mechanisms of lumen enlargement after excimer laser coronary angioplasty: an intravascular ultrasound study. Circulation 92 (1995) 3408-3414
    • (1995) Circulation , vol.92 , pp. 3408-3414
    • Mintz, G.S.1    Kovach, J.A.2    Javier, S.P.3    Pichard, A.D.4    Kent, K.M.5    Popma, J.J.6
  • 92
    • 0028342931 scopus 로고
    • Acute complications of excimer laser coronary angioplasty: a detailed analysis of multicenter results
    • Baumbach A., Bittl J.A., Fleck E., Geschwind H.J., Sanborn T.A., and Tcheng J.E. Acute complications of excimer laser coronary angioplasty: a detailed analysis of multicenter results. J Am Coll Cardiol 23 (1994) 1305-1313
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1305-1313
    • Baumbach, A.1    Bittl, J.A.2    Fleck, E.3    Geschwind, H.J.4    Sanborn, T.A.5    Tcheng, J.E.6
  • 93
    • 0027401949 scopus 로고
    • Intraluminal vapor bubble induced by excimer laser pulse causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit
    • Van Leeuwen T.G., Meertens J.H., Velema E., Post M.J., and Borst C. Intraluminal vapor bubble induced by excimer laser pulse causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit. Circulation 87 (1993) 1258-1263
    • (1993) Circulation , vol.87 , pp. 1258-1263
    • Van Leeuwen, T.G.1    Meertens, J.H.2    Velema, E.3    Post, M.J.4    Borst, C.5
  • 95
    • 0030829314 scopus 로고    scopus 로고
    • Perspectives of coronary excimer laser angioplasty: multiplexing saline flushing and acoustic ablation control
    • Haase K.K., Rose C., Duda S., Baumbach A., Oberhoff M., Anthanasiadis A., et al. Perspectives of coronary excimer laser angioplasty: multiplexing saline flushing and acoustic ablation control. Lasers Surg Med 21 (1997) 72-79
    • (1997) Lasers Surg Med , vol.21 , pp. 72-79
    • Haase, K.K.1    Rose, C.2    Duda, S.3    Baumbach, A.4    Oberhoff, M.5    Anthanasiadis, A.6
  • 96
    • 0027523678 scopus 로고
    • In search of the optimized excimer laser angioplasty system
    • Litvack F., Eigler N.L., and Forrester J.S. In search of the optimized excimer laser angioplasty system. Circulation 87 (1993) 1421-1422
    • (1993) Circulation , vol.87 , pp. 1421-1422
    • Litvack, F.1    Eigler, N.L.2    Forrester, J.S.3
  • 97
    • 0030005039 scopus 로고    scopus 로고
    • Excimer laser induced bubble: dimensions theory and implications for laser angioplasty
    • Van Leeuwen T.G., Janse E.D., Welch A.J., and Borst C. Excimer laser induced bubble: dimensions theory and implications for laser angioplasty. Lasers Surg Med 18 (1996) 381-390
    • (1996) Lasers Surg Med , vol.18 , pp. 381-390
    • Van Leeuwen, T.G.1    Janse, E.D.2    Welch, A.J.3    Borst, C.4
  • 98
    • 0031681283 scopus 로고    scopus 로고
    • Saline flush during excimer laser angioplasty: short and long term effects in the rabbit femoral artery
    • Van Leeuwen T.G., Velema E., Pasterkamp G., Post M.J., and Borst C. Saline flush during excimer laser angioplasty: short and long term effects in the rabbit femoral artery. Lasers Surg Med 23 (1998) 128-140
    • (1998) Lasers Surg Med , vol.23 , pp. 128-140
    • Van Leeuwen, T.G.1    Velema, E.2    Pasterkamp, G.3    Post, M.J.4    Borst, C.5
  • 99
    • 0030081763 scopus 로고    scopus 로고
    • Minimization of cavitation effects in pulsed laser ablation illustrated on laser angioplasty
    • Vogel A., Engelhardt R., Behnle U., and Parlitz U. Minimization of cavitation effects in pulsed laser ablation illustrated on laser angioplasty. Appl Phys B 62 (1996) 173-182
    • (1996) Appl Phys B , vol.62 , pp. 173-182
    • Vogel, A.1    Engelhardt, R.2    Behnle, U.3    Parlitz, U.4
  • 100
    • 0034864733 scopus 로고    scopus 로고
    • Minimization of thermo-mechanical side effects in IR ablation by use of Q-switched double pulses
    • Vogel A., Schmidt P., and Flucke B. Minimization of thermo-mechanical side effects in IR ablation by use of Q-switched double pulses. Proc SPIE 4257 (2001) 184-191
    • (2001) Proc SPIE , vol.4257 , pp. 184-191
    • Vogel, A.1    Schmidt, P.2    Flucke, B.3
  • 101
    • 0036381405 scopus 로고    scopus 로고
    • Minimization of thermomechanical side effects and increase in ablation efficiency in IR ablation by use of multiply Q-switched laser pulses
    • Vogel A., Schmidt P., and Flucke B. Minimization of thermomechanical side effects and increase in ablation efficiency in IR ablation by use of multiply Q-switched laser pulses. Proc SPIE 4617 (2002) 105-111
    • (2002) Proc SPIE , vol.4617 , pp. 105-111
    • Vogel, A.1    Schmidt, P.2    Flucke, B.3
  • 102
    • 0026720842 scopus 로고
    • High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis
    • Zotz R.J., Erbel R., Philipp A., Judt A., Wagner H., Lauterborn W., et al. High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis. Catheter Cardiovasc Diagn 26 (1992) 98-109
    • (1992) Catheter Cardiovasc Diagn , vol.26 , pp. 98-109
    • Zotz, R.J.1    Erbel, R.2    Philipp, A.3    Judt, A.4    Wagner, H.5    Lauterborn, W.6
  • 103
    • 13544251735 scopus 로고    scopus 로고
    • Mechanical heart valve cavitation
    • Johansen P. Mechanical heart valve cavitation. Exp Rev Med Dev 1 (2004) 95-104
    • (2004) Exp Rev Med Dev , vol.1 , pp. 95-104
    • Johansen, P.1
  • 104
    • 0016980042 scopus 로고
    • Problems of thrombogenesis and destruction of the superficial layer of implanted artificial heat valves
    • Zubarev R.P., Kolpakov E.V., Morov G.V., and Gabeskiriia R.I. Problems of thrombogenesis and destruction of the superficial layer of implanted artificial heat valves. Med Tekh 4 (1976) 26-29
    • (1976) Med Tekh , vol.4 , pp. 26-29
    • Zubarev, R.P.1    Kolpakov, E.V.2    Morov, G.V.3    Gabeskiriia, R.I.4
  • 106
  • 107
    • 0025801818 scopus 로고
    • Cavitation potential of mechanical heart valve prostheses
    • Graf T., Fischer H., Reul H., and Rau G. Cavitation potential of mechanical heart valve prostheses. Int J Artif Organs 14 (1991) 169-174
    • (1991) Int J Artif Organs , vol.14 , pp. 169-174
    • Graf, T.1    Fischer, H.2    Reul, H.3    Rau, G.4
  • 109
    • 0037542569 scopus 로고    scopus 로고
    • A new approach to detection of the cavitation on mechanical heart valves
    • Takiura K., Chinzei T., Abe Y., Isoyama T., Saito I., Ozeki T., et al. A new approach to detection of the cavitation on mechanical heart valves. ASAIO J 49 (2003) 304-308
    • (2003) ASAIO J , vol.49 , pp. 304-308
    • Takiura, K.1    Chinzei, T.2    Abe, Y.3    Isoyama, T.4    Saito, I.5    Ozeki, T.6
  • 110
    • 0029155885 scopus 로고
    • Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: mounting compliance effect
    • Wu S.Z., Gao B.Z., and Hwang N.H. Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: mounting compliance effect. J Heart Valve Dis 4 (1995) 553-567
    • (1995) J Heart Valve Dis , vol.4 , pp. 553-567
    • Wu, S.Z.1    Gao, B.Z.2    Hwang, N.H.3
  • 111
    • 0031282173 scopus 로고    scopus 로고
    • Mechanical valve closing dynamics: relationship between velocity of closing pressure transients and cavitation initiation
    • Chandran K.B., and Aluri S. Mechanical valve closing dynamics: relationship between velocity of closing pressure transients and cavitation initiation. Ann Biomed Eng 25 (1997) 926-938
    • (1997) Ann Biomed Eng , vol.25 , pp. 926-938
    • Chandran, K.B.1    Aluri, S.2
  • 114
    • 0032828713 scopus 로고    scopus 로고
    • High-frequency pressure fluctuations measured in heart valve patients
    • Paulsen P.K., Jensen B.K., Hasenkam J.M., and Nygaard H. High-frequency pressure fluctuations measured in heart valve patients. J Heart Valve Dis 8 (1999) 482-486
    • (1999) J Heart Valve Dis , vol.8 , pp. 482-486
    • Paulsen, P.K.1    Jensen, B.K.2    Hasenkam, J.M.3    Nygaard, H.4
  • 116
    • 0028466260 scopus 로고
    • The closing behaviour of Medtronic Hall mechanical heart valves
    • Wu S.Z., Shu M.C., Scott D.R., and Hwang N.H. The closing behaviour of Medtronic Hall mechanical heart valves. ASAIO J 40 (1994) M702-M706
    • (1994) ASAIO J , vol.40
    • Wu, S.Z.1    Shu, M.C.2    Scott, D.R.3    Hwang, N.H.4
  • 117
    • 33746783757 scopus 로고    scopus 로고
    • Development of squeeze flow in mechanical heart valve: a particle image velocimetry investigation
    • Zhang P., Yeo J.H., and Hwang N.H.C. Development of squeeze flow in mechanical heart valve: a particle image velocimetry investigation. ASAIO J 52 (2006) 391-397
    • (2006) ASAIO J , vol.52 , pp. 391-397
    • Zhang, P.1    Yeo, J.H.2    Hwang, N.H.C.3
  • 118
    • 33748294141 scopus 로고    scopus 로고
    • Mechanism for cavitation phenomenon in mechanical heart valves
    • Lee H., and Taenaka Y. Mechanism for cavitation phenomenon in mechanical heart valves. J Mech Sci Technol 20 (2006) 1118-1124
    • (2006) J Mech Sci Technol , vol.20 , pp. 1118-1124
    • Lee, H.1    Taenaka, Y.2
  • 119
    • 0031733109 scopus 로고    scopus 로고
    • A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics
    • Zapanta C.M., Stinebring D.R., Deutsch S., Geselowitz D.B., and Tarbell J.M. A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics. J Heart Valve Dis 7 (1998) 655-667
    • (1998) J Heart Valve Dis , vol.7 , pp. 655-667
    • Zapanta, C.M.1    Stinebring, D.R.2    Deutsch, S.3    Geselowitz, D.B.4    Tarbell, J.M.5
  • 120
    • 0033952306 scopus 로고    scopus 로고
    • Can vortices in the flow across mechanical heart valves contribute to cavitation?
    • Avrahami I., Rosenfeld M., Einav S., Eicher M., and Reul H. Can vortices in the flow across mechanical heart valves contribute to cavitation?. Med Biol Eng Comput 38 (2000) 93-97
    • (2000) Med Biol Eng Comput , vol.38 , pp. 93-97
    • Avrahami, I.1    Rosenfeld, M.2    Einav, S.3    Eicher, M.4    Reul, H.5
  • 121
    • 0043236252 scopus 로고    scopus 로고
    • Regurgitant flow field characteristics of the St Jude bileaflet mechanical heart valve under physiological pulsatile flow using particle image velocimetry
    • Manning K.B., Kini V., Fontaine A.A., Deutsch S., and Tarbell J.M. Regurgitant flow field characteristics of the St Jude bileaflet mechanical heart valve under physiological pulsatile flow using particle image velocimetry. Artif Organs 27 (2003) 840-846
    • (2003) Artif Organs , vol.27 , pp. 840-846
    • Manning, K.B.1    Kini, V.2    Fontaine, A.A.3    Deutsch, S.4    Tarbell, J.M.5
  • 122
    • 34250734601 scopus 로고    scopus 로고
    • Role of vortices in growth of microbubbles at mitral mechanical heart valve closure
    • Rambod E., Beizai M., Sahn D.J., and Gharib M. Role of vortices in growth of microbubbles at mitral mechanical heart valve closure. Ann Biomed Eng 35 (2007) 1131-1145
    • (2007) Ann Biomed Eng , vol.35 , pp. 1131-1145
    • Rambod, E.1    Beizai, M.2    Sahn, D.J.3    Gharib, M.4
  • 123
    • 0031961301 scopus 로고    scopus 로고
    • Cavitation potential of pyrolytic carbon heart valve prostheses: a review and current status
    • Hwang N.H. Cavitation potential of pyrolytic carbon heart valve prostheses: a review and current status. J Heart Valve Dis 7 (1998) 140-150
    • (1998) J Heart Valve Dis , vol.7 , pp. 140-150
    • Hwang, N.H.1
  • 126
    • 0032586264 scopus 로고    scopus 로고
    • Microbubbles and mitral valve prostheses-transesophageal echocardiographic evaluation
    • Levy D.J., Child J.S., Rambod E., Gharib M., Milo S., and Reisner S.A. Microbubbles and mitral valve prostheses-transesophageal echocardiographic evaluation. Eur J Ultrasound 10 (1999) 31-40
    • (1999) Eur J Ultrasound , vol.10 , pp. 31-40
    • Levy, D.J.1    Child, J.S.2    Rambod, E.3    Gharib, M.4    Milo, S.5    Reisner, S.A.6
  • 127
    • 0036776095 scopus 로고    scopus 로고
    • Cavitation versus degassing: in vitro study of the microbubble phenomenon observed during echocardiography in patients with mechanical prosthetic cardiac valves
    • Girod G., Jaussi A., Rosset C., de Werra P., Hirt F., and Kappenberger L. Cavitation versus degassing: in vitro study of the microbubble phenomenon observed during echocardiography in patients with mechanical prosthetic cardiac valves. Echocardiography 19 (2002) 531-536
    • (2002) Echocardiography , vol.19 , pp. 531-536
    • Girod, G.1    Jaussi, A.2    Rosset, C.3    de Werra, P.4    Hirt, F.5    Kappenberger, L.6
  • 129
    • 0041761121 scopus 로고    scopus 로고
    • Mitral mechanical heart valves: in vitro studies of their closure vortex and microbubble formation with possible medical implications
    • Milo S., Rambod E., Gutfinger C., and Gharib M. Mitral mechanical heart valves: in vitro studies of their closure vortex and microbubble formation with possible medical implications. Eur J Cardiothorac Surg 24 (2003) 364-370
    • (2003) Eur J Cardiothorac Surg , vol.24 , pp. 364-370
    • Milo, S.1    Rambod, E.2    Gutfinger, C.3    Gharib, M.4
  • 130
    • 0036357996 scopus 로고    scopus 로고
    • Mechanisms of cavitation and the formation of stable bubbles on the Bjork-Shiley Monostrut prosthetic heart valve
    • Bachmann C., Kini V., Deutsch S., Fontaine A.A., and Tarbell J.M. Mechanisms of cavitation and the formation of stable bubbles on the Bjork-Shiley Monostrut prosthetic heart valve. J Heart Valve Dis 11 (2002) 105-113
    • (2002) J Heart Valve Dis , vol.11 , pp. 105-113
    • Bachmann, C.1    Kini, V.2    Deutsch, S.3    Fontaine, A.A.4    Tarbell, J.M.5
  • 132
    • 0037465510 scopus 로고    scopus 로고
    • Role of risk factors in the modulation of tissue factor activity and blood thrombogenicity
    • Sambola A., Osende J., Hathcock J., Degen M., Nemerson Y., Fuster V., et al. Role of risk factors in the modulation of tissue factor activity and blood thrombogenicity. Circulation 107 (2003) 973-977
    • (2003) Circulation , vol.107 , pp. 973-977
    • Sambola, A.1    Osende, J.2    Hathcock, J.3    Degen, M.4    Nemerson, Y.5    Fuster, V.6
  • 134
    • 14344263606 scopus 로고    scopus 로고
    • Direct numerical simulations of micro-bubble expansion in gas embolotherapy
    • Ye T., and Bull J.L. Direct numerical simulations of micro-bubble expansion in gas embolotherapy. J Biomech Eng 126 (2004) 745-759
    • (2004) J Biomech Eng , vol.126 , pp. 745-759
    • Ye, T.1    Bull, J.L.2
  • 136
    • 33746913888 scopus 로고    scopus 로고
    • Microbubble expansion in a flexible tube
    • Ye T., and Bull J.L. Microbubble expansion in a flexible tube. J Biomech Eng 128 (2006) 554-563
    • (2006) J Biomech Eng , vol.128 , pp. 554-563
    • Ye, T.1    Bull, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.