-
1
-
-
0003817720
-
-
Young FR (ed) London, McGraw-Hill Book Company
-
Young FR (ed): Cavitation. London, McGraw-Hill Book Company, 1989.
-
(1989)
Cavitation
-
-
-
2
-
-
0024495078
-
Leaflet fracture in Edwards Duromedics bileaflet valves
-
Klepetko W, Moritz A: Leaflet fracture in Edwards Duromedics bileaflet valves. J Thorac Cardio Vasc Surg 97: 90-94, 1989.
-
(1989)
J Thorac Cardio Vasc Surg
, vol.97
, pp. 90-94
-
-
Klepetko, W.1
Moritz, A.2
-
3
-
-
0031961301
-
Cavitation potential of pyrolytic carbon heart valve Prostheses: A review and current status
-
Hwang NHC: Cavitation potential of pyrolytic carbon heart valve Prostheses: A review and current status. J Heart Valve Dis 7: 140-150, 1998.
-
(1998)
J Heart Valve Dis
, vol.7
, pp. 140-150
-
-
Hwang, N.H.C.1
-
4
-
-
0034793868
-
Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model
-
He ZM, Xi BS, Zhu KQ, Hwang NHC: Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model. J Heart Valve Dis 10: 666-674, 2001.
-
(2001)
J Heart Valve Dis
, vol.10
, pp. 666-674
-
-
He, Z.M.1
Xi, B.S.2
Zhu, K.Q.3
Hwang, N.H.C.4
-
5
-
-
0026168904
-
Review-mechanisms of cavitation inception
-
Rood EP: Review-mechanisms of cavitation inception. J Fluids Eng 113: 163-175, 1991.
-
(1991)
J Fluids Eng
, vol.113
, pp. 163-175
-
-
Rood, E.P.1
-
6
-
-
0027943765
-
Cavitation dynamics of mechanical heart valve prostheses
-
Lee CS, Chandran KB, Chen LD: Cavitation dynamics of mechanical heart valve prostheses. Artif Organs 18: 138-142, 1994.
-
(1994)
Artif Organs
, vol.18
, pp. 138-142
-
-
Lee, C.S.1
Chandran, K.B.2
Chen, L.D.3
-
7
-
-
0030087603
-
Cavitation dynamics of Medtronic hall mechanical heart valve prosthesis: Fluid squeezing effect
-
Lee CS, Chandran KB, Chen LD: Cavitation dynamics of Medtronic hall mechanical heart valve prosthesis: fluid squeezing effect. J Biomech Eng 118: 97-105, 1996.
-
(1996)
J Biomech Eng
, vol.118
, pp. 97-105
-
-
Lee, C.S.1
Chandran, K.B.2
Chen, L.D.3
-
8
-
-
0032294655
-
In vitro demonstration of squeeze flow at the instant of mechanical heart valve closure
-
Chandran KB, Chew YT, Low HT, et al: In vitro demonstration of squeeze flow at the instant of mechanical heart valve closure. ASME Adv Bioeng 39: 75-76, 1998.
-
(1998)
ASME Adv Bioeng
, vol.39
, pp. 75-76
-
-
Chandran, K.B.1
Chew, Y.T.2
Low, H.T.3
-
9
-
-
0042125061
-
Cavitation phenomenon in mechanical heart valves: The role of squeeze flow velocity and contact area on cavitation initiation between two impinging rods
-
Lim WL, Chew YT, Low HT, Foo WL: Cavitation phenomenon in mechanical heart valves: The role of squeeze flow velocity and contact area on cavitation initiation between two impinging rods. J Biomech 36: 1269-1280, 2003.
-
(2003)
J Biomech
, vol.36
, pp. 1269-1280
-
-
Lim, W.L.1
Chew, Y.T.2
Low, H.T.3
Foo, W.L.4
-
10
-
-
0031965282
-
Mean velocity and Reynolds stress measurements in the regurgitant jets of tilting disk heart valves in an artificial heart environment
-
Maymir JC, Deutsch S, Meyer RS, et al: Mean velocity and Reynolds stress measurements in the regurgitant jets of tilting disk heart valves in an artificial heart environment. Ann Biomed Eng 26: 146-156, 1998.
-
(1998)
Ann Biomed Eng
, vol.26
, pp. 146-156
-
-
Maymir, J.C.1
Deutsch, S.2
Meyer, R.S.3
-
11
-
-
0033623709
-
Flow visualization in mechanical heart valves: Occluder rebound and cavitation potential
-
Kini V, Bachmann C, Fontaine A, et al: Flow visualization in mechanical heart valves: Occluder rebound and cavitation potential. Ann Biomed Eng 28: 431-441, 2000.
-
(2000)
Ann Biomed Eng
, vol.28
, pp. 431-441
-
-
Kini, V.1
Bachmann, C.2
Fontaine, A.3
-
12
-
-
0043236252
-
Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry
-
Manning KB, Kini V, Fontaine AA, et al: Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry. Artif Organs 27: 840-846, 2003.
-
(2003)
Artif Organs
, vol.27
, pp. 840-846
-
-
Manning, K.B.1
Kini, V.2
Fontaine, A.A.3
-
13
-
-
0028533807
-
A squeeze flow phenomenon at closing of a bileaflet mechanical heart valve prosthesis
-
Blustein D, Einav S, Hwang NHC: A squeeze flow phenomenon at closing of a bileaflet mechanical heart valve prosthesis. J Biomech 27: 1369-1378, 1994.
-
(1994)
J Biomech
, vol.27
, pp. 1369-1378
-
-
Blustein, D.1
Einav, S.2
Hwang, N.H.C.3
-
14
-
-
0028303198
-
An experimental-computational analysis of MHV cavitation: Effect of leaflet squeezing and rebound
-
Makhijani VB, Yang HQ, Singhal AK, Hwang NHC: An experimental- computational analysis of MHV cavitation: Effect of leaflet squeezing and rebound. J Heart Valve Dis 3(Suppl I): 35-48, 1994.
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.1 SUPPL.
, pp. 35-48
-
-
Makhijani, V.B.1
Yang, H.Q.2
Singhal, A.K.3
Hwang, N.H.C.4
-
15
-
-
0030032456
-
Numerical study of squeeze-flow in tilting disc mechanical heart valves
-
Makhijani VB, Siegel JM, Hwang NHC: Numerical study of squeeze-flow in tilting disc mechanical heart valves. J Heart Valve Dis 5: 97-103, 1996.
-
(1996)
J Heart Valve Dis
, vol.5
, pp. 97-103
-
-
Makhijani, V.B.1
Siegel, J.M.2
Hwang, N.H.C.3
-
16
-
-
12044260218
-
Particle-imaging techniques for experimental fluid mechanics
-
Adrian RJ: Particle-imaging techniques for experimental fluid mechanics. Ann Rev Fluid Mech 23: 261-304, 1991.
-
(1991)
Ann Rev Fluid Mech
, vol.23
, pp. 261-304
-
-
Adrian, R.J.1
-
17
-
-
0036646795
-
Unsteady flow through a new mechanical heart valve prosthesis analyzed by digital particle image velocimetry
-
Brucker C, Steinseifer U, Schroder W, Reul H: Unsteady flow through a new mechanical heart valve prosthesis analyzed by digital particle image velocimetry. Meas Sci Tech 13: 1043-1049, 2002.
-
(2002)
Meas Sci Tech
, vol.13
, pp. 1043-1049
-
-
Brucker, C.1
Steinseifer, U.2
Schroder, W.3
Reul, H.4
-
18
-
-
0028275103
-
Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: Correlation with cavitation initiation
-
Chandran KB, Lee CS, Chen LD: Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: Correlation with cavitation initiation. J Heart Valve Dis 3(Suppl I): 65-76,1994.
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.1 SUPPL.
, pp. 65-76
-
-
Chandran, K.B.1
Lee, C.S.2
Chen, L.D.3
-
19
-
-
0031282173
-
Mechanical valve closing dynamics: Relationship between velocity of closing, pressure transients, and cavitation initiation
-
Chandran KB, Aluri S: Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation. Ann Biomed Eng 25: 926-938, 1997.
-
(1997)
Ann Biomed Eng
, vol.25
, pp. 926-938
-
-
Chandran, K.B.1
Aluri, S.2
-
20
-
-
0032112265
-
Negative pressure transients with mechanical hear valve closure: Correlation between in vitro and in vivo results
-
Chandran KB, Dexter EU, Aluri S, Richenbacher WE: Negative pressure transients with mechanical hear valve closure: correlation between in vitro and in vivo results. Ann Biomed Eng 26: 546-556, 1998.
-
(1998)
Ann Biomed Eng
, vol.26
, pp. 546-556
-
-
Chandran, K.B.1
Dexter, E.U.2
Aluri, S.3
Richenbacher, W.E.4
-
21
-
-
0029828882
-
An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves
-
Ellis JT, Healy TM, Fontaine AA, Weston MW: An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. J Heart Valve Dis 5: 600-606, 1996.
-
(1996)
J Heart Valve Dis
, vol.5
, pp. 600-606
-
-
Ellis, J.T.1
Healy, T.M.2
Fontaine, A.A.3
Weston, M.W.4
-
22
-
-
0025144789
-
Laser assessment of leaflet closing motion in prosthetic heart valve
-
Guo GX, Xu CC, Hwang NHC: Laser assessment of leaflet closing motion in prosthetic heart valve. J Biomed Eng 12: 447-481, 1990.
-
(1990)
J Biomed Eng
, vol.12
, pp. 447-481
-
-
Guo, G.X.1
Xu, C.C.2
Hwang, N.H.C.3
-
23
-
-
0032072741
-
Steady flow dynamics of prosthetic aortic hearts: A comparative evaluation with PIV techniques
-
Lim WL, Chew YT, Chew TC, Low HT: Steady flow dynamics of prosthetic aortic hearts: A comparative evaluation with PIV techniques. J Biomech 31: 411-421, 1998.
-
(1998)
J Biomech
, vol.31
, pp. 411-421
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
24
-
-
0034791973
-
Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurement and shear induced blood damage
-
Lim WL, Chew YT, Chew TC, Low HT: Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurement and shear induced blood damage. J Biomech 34: 1417-1427, 2001.
-
(2001)
J Biomech
, vol.34
, pp. 1417-1427
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
25
-
-
0030865224
-
Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve
-
Maymir JC, Deutsch S, Meyer RS, et al: Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve. Artif Organs 21: 1014-1025, 1997.
-
(1997)
Artif Organs
, vol.21
, pp. 1014-1025
-
-
Maymir, J.C.1
Deutsch, S.2
Meyer, R.S.3
-
26
-
-
0001075219
-
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
-
Prasad AK, Adrian RJ, Landreth CC, Offutt PW: Effect of resolution on the speed and accuracy of particle image velocimetry interrogation. Exp Fluids 13: 105-116, 1992.
-
(1992)
Exp Fluids
, vol.13
, pp. 105-116
-
-
Prasad, A.K.1
Adrian, R.J.2
Landreth, C.C.3
Offutt, P.W.4
-
27
-
-
0003525067
-
-
Raffel M, Willert C, Kompenhans J (eds) Berlin, New York, Springer
-
Raffel M, Willert C, Kompenhans J (eds): Particle Image Velocimetry: A Practical Guide. Berlin, New York, Springer, 1998.
-
(1998)
Particle Image Velocimetry: A Practical Guide
-
-
-
28
-
-
0028287316
-
In vitro observation of mechanical heart valve cavitation
-
Shu MCS, Leuer LH, Armitage TL, et al: In vitro observation of mechanical heart valve cavitation. J Heart Valve Dis 3(Suppl I): S85-S93, 1994.
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.1 SUPPL.
-
-
Shu, M.C.S.1
Leuer, L.H.2
Armitage, T.L.3
-
29
-
-
0033774274
-
Particle image velocity investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow
-
Subramanian A, Mu H, Kadambi JR, et al: Particle image velocity investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow. J Heart Valve Dis 9: 721-731, 2000.
-
(2000)
J Heart Valve Dis
, vol.9
, pp. 721-731
-
-
Subramanian, A.1
Mu, H.2
Kadambi, J.R.3
-
30
-
-
0025792678
-
Digital particle image velocimetry
-
Willert CE, Gharib M: Digital particle image velocimetry. Exp Fluids 10: 181-193, 1991.
-
(1991)
Exp Fluids
, vol.10
, pp. 181-193
-
-
Willert, C.E.1
Gharib, M.2
-
31
-
-
0028298260
-
Occluder closing behavior: A key factor in mechanical heart valve cavitation
-
Wu ZJ, Wang Y, Hwang NHC: Occluder closing behavior: A key factor in mechanical heart valve cavitation. J Heart Valve Dis 3(Suppl I): 25-34, 1994.
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.1 SUPPL.
, pp. 25-34
-
-
Wu, Z.J.1
Wang, Y.2
Hwang, N.H.C.3
-
32
-
-
0029155885
-
Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: Mounting compliance effect
-
Wu ZJ, Gao BZ, Hwang NHC: Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: Mounting compliance effect. J Heart Valve Dis 4: 553-567, 1995.
-
(1995)
J Heart Valve Dis
, vol.4
, pp. 553-567
-
-
Wu, Z.J.1
Gao, B.Z.2
Hwang, N.H.C.3
-
33
-
-
0035086821
-
Digital particle image velocimetry investigation of the pulsating flow around a simplified 2-D model of a bileaflet heart valve
-
Zhao JB, Shi YB, Yeo JH, Hwang NHC: Digital particle image velocimetry investigation of the pulsating flow around a simplified 2-D model of a bileaflet heart valve. J Heart Valve Dis 10: 239-253, 2001.
-
(2001)
J Heart Valve Dis
, vol.10
, pp. 239-253
-
-
Zhao, J.B.1
Shi, Y.B.2
Yeo, J.H.3
Hwang, N.H.C.4
|