1
-
-
0028275103
-
Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: Correlation with cavitation initiation
-
Chandran KB, Lee CS, Chen LD. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: Correlation with cavitation initiation. J Heart Valve Dis 1994;3(suppl.I):S65-S76
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. I
-
-
Chandran, K.B.1
Lee, C.S.2
Chen, L.D.3
-
3
-
-
0028231956
-
Cavitation damage of pyrolytic carbon in mechanical heart valves
-
Kafesjian R, Howanec M, Ward GD, Diep L, Wagstaff L, Rhee R. Cavitation damage of pyrolytic carbon in mechanical heart valves. J Heart Valve Dis 1994;3(suppl.I):S2-S7
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. I
-
-
Kafesjian, R.1
Howanec, M.2
Ward, G.D.3
Diep, L.4
Wagstaff, L.5
Rhee, R.6
-
5
-
-
0024495078
-
Leaflet fracture in Edwards-Duromedics bileaflet valves
-
Klepetko W, Moritz A, Mlczoch J, Schurawitzki H, Domanig E, Wolner E. Leaflet fracture in Edwards-Duromedics bileaflet valves. J Thorac Cardiovasc Surg 1989;97:90-94
-
(1989)
J. Thorac. Cardiovasc. Surg.
, vol.97
, pp. 90-94
-
-
Klepetko, W.1
Moritz, A.2
Mlczoch, J.3
Schurawitzki, H.4
Domanig, E.5
Wolner, E.6
-
6
-
-
0024520952
-
Leaflet escape of a mitral Duromedics prosthesis. Case report
-
Deuvaert FE, Devriendt J, Massaut J, Van Nooten G, De Paepe J, Primo G. Leaflet escape of a mitral Duromedics prosthesis. Case report. Acta Chir Belg 1989;89:15-18
-
(1989)
Acta Chir. Belg.
, vol.89
, pp. 15-18
-
-
Deuvaert, F.E.1
Devriendt, J.2
Massaut, J.3
Van Nooten, G.4
De Paepe, J.5
Primo, G.6
-
7
-
-
0025118287
-
Fracture of the Duromedics mitral valve housing with leaflet escape
-
Dimitri WR, Williams BT. Fracture of the Duromedics mitral valve housing with leaflet escape. J Cardiovasc Surg (Torino) 1990;31:41-46
-
(1990)
J. Cardiovasc. Surg. (Torino)
, vol.31
, pp. 41-46
-
-
Dimitri, W.R.1
Williams, B.T.2
-
8
-
-
0026334644
-
Leaflet embolisation from Duromedics valves: A report of two cases
-
Kumar N, Balasundaram S, Rickard M, al Halees Z, Duran CM. Leaflet embolisation from Duromedics valves: A report of two cases. Thorac Cardiovasc Surg 1991;39:382-383
-
(1991)
Thorac. Cardiovasc. Surg.
, vol.39
, pp. 382-383
-
-
Kumar, N.1
Balasundaram, S.2
Rickard, M.3
al Halees, Z.4
Duran, C.M.5
-
9
-
-
0020572263
-
Escape of a leaflet from a St. Jude Medical prosthesis in the mitral position
-
Hjelms E. Escape of a leaflet from a St. Jude Medical prosthesis in the mitral position. Thorac Cardiovasc Surg 1983;31:310-312
-
(1983)
Thorac. Cardiovasc. Surg.
, vol.31
, pp. 310-312
-
-
Hjelms, E.1
-
10
-
-
0028333976
-
An in-vitro investigation of prosthetic heart valve cavitation in blood
-
Garrison LA, Lamson TC, Deutsch S, Geselowitz DB, Gaumond RP, Tarbell JM. An in-vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis 1994;3(suppl.I):S8-S22
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. I
-
-
Garrison, L.A.1
Lamson, T.C.2
Deutsch, S.3
Geselowitz, D.B.4
Gaumond, R.P.5
Tarbell, J.M.6
-
12
-
-
0029155885
-
Transient pressure at closing of monoleaflet mechanical heart valve prosthesis: Mounting compliance effect
-
Wu ZJ, Gao BZ, Hwang NH. Transient pressure at closing of monoleaflet mechanical heart valve prosthesis: Mounting compliance effect. J Heart Valve Dis 1995;4:553-567
-
(1995)
J. Heart Valve Dis.
, vol.4
, pp. 553-567
-
-
Wu, Z.J.1
Gao, B.Z.2
Hwang, N.H.3
-
13
-
-
0036739473
-
Spectral characteristics of mechanical heart valve closing sounds
-
Johansen P, Lomholt M, Nygaard H. Spectral characteristics of mechanical heart valve closing sounds. J Heart Valve Dis 2002;11:736-744
-
(2002)
J. Heart Valve Dis.
, vol.11
, pp. 736-744
-
-
Johansen, P.1
Lomholt, M.2
Nygaard, H.3
-
16
-
-
0032112265
-
Negative pressure transients with mechanical heart-valve closure: Correlation between in vitro and in vivo results
-
Chandran KB, Dexter EU, Aluri S, Richenbacher WE. Negative pressure transients with mechanical heart-valve closure: Correlation between in vitro and in vivo results. Ann Biomed Eng 1998;26:546-556
-
(1998)
Ann. Biomed. Eng.
, vol.26
, pp. 546-556
-
-
Chandran, K.B.1
Dexter, E.U.2
Aluri, S.3
Richenbacher, W.E.4
-
18
-
-
0028553865
-
Measurement of sounds generated by mechanical aortic and mitral heart valve prostheses
-
1994 IEEE Seventh Symposium on Computer-Based Medical Systems, 10-12 June 1994:55-60
-
Nygaard H, Inderbitzen R, Hasenkam JM, Wieting DW, Paulsen PK. Measurement of sounds generated by mechanical aortic and mitral heart valve prostheses. 1994 IEEE Seventh Symposium on Computer-Based Medical Systems, 10-12 June 1994:55-60, 2000
-
(2000)
-
-
Nygaard, H.1
Inderbitzen, R.2
Hasenkam, J.M.3
Wieting, D.W.4
Paulsen, P.K.5
-
19
-
-
0031282173
-
Mechanical valve closing dynamics: Relationship between velocity of closing, pressure transients, and cavitation initiation
-
Chandran KB, Aluri S. Mechanical valve closing dynamics: Relationship between velocity of closing, pressure transients, and cavitation initiation. Ann Biomed Eng 1997;25:926-938
-
(1997)
Ann. Biomed. Eng.
, vol.25
, pp. 926-938
-
-
Chandran, K.B.1
Aluri, S.2
-
21
-
-
0028287316
-
In vitro observations of mechanical heart valve cavitation
-
Shu MC, Leuer LH, Armitage TL, Schneider TE, Christiansen DR. In vitro observations of mechanical heart valve cavitation. J Heart Valve Dis 1994;3(suppl.I):S85-S92
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. I
-
-
Shu, M.C.1
Leuer, L.H.2
Armitage, T.L.3
Schneider, T.E.4
Christiansen, D.R.5
-
22
-
-
0028223502
-
Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses
-
Richard G, Beavan A, Strzepa P. Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses. J Heart Valve Dis 1994;3(suppl.I):S94-S101
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. I
-
-
Richard, G.1
Beavan, A.2
Strzepa, P.3
-
23
-
-
0027943765
-
Cavitation dynamics of mechanical heart valve prostheses
-
Lee CS, Chandran KB, Chen LD. Cavitation dynamics of mechanical heart valve prostheses. Artif Organs 1994;18:758-767
-
(1994)
Artif. Organs
, vol.18
, pp. 758-767
-
-
Lee, C.S.1
Chandran, K.B.2
Chen, L.D.3
-
24
-
-
0030087603
-
Cavitation dynamics of Medtronic Hall mechanical heart valve prosthesis: Fluid squeezing effect
-
Lee CS, Chandran KB, Chen LD. Cavitation dynamics of Medtronic Hall mechanical heart valve prosthesis: Fluid squeezing effect. J Biomech Eng 1996;118:97-105
-
(1996)
J. Biomech. Eng.
, vol.118
, pp. 97-105
-
-
Lee, C.S.1
Chandran, K.B.2
Chen, L.D.3
|