메뉴 건너뛰기




Volumn 81, Issue 12 A, 1998, Pages 58G-61G

In vitro studies of a new thrombus-specific ultrasound contrast agent

Author keywords

[No Author keywords available]

Indexed keywords

HEXAPEPTIDE; LIPOSOME; MRX 408; UNCLASSIFIED DRUG;

EID: 0032543535     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(98)00055-1     Document Type: Conference Paper
Times cited : (148)

References (19)
  • 3
    • 0027976616 scopus 로고
    • Comparison of venography, duplex imaging, and bilateral impedance plethysmography for diagnosis of lower extremity deep vein thrombosis
    • Kristo DA, Perry ME, Kollef MH. Comparison of venography, duplex imaging, and bilateral impedance plethysmography for diagnosis of lower extremity deep vein thrombosis. South Med J 1994;87:55-60.
    • (1994) South Med J , vol.87 , pp. 55-60
    • Kristo, D.A.1    Perry, M.E.2    Kollef, M.H.3
  • 4
    • 0028970450 scopus 로고
    • Bilateral lower extremity US in the patient with unilateral symptoms of deep venous thrombosis: Assessment of need
    • Scheiman RG, McArdle CR. Bilateral lower extremity US in the patient with unilateral symptoms of deep venous thrombosis: assessment of need. Radiology 1995;194:171-173.
    • (1995) Radiology , vol.194 , pp. 171-173
    • Scheiman, R.G.1    McArdle, C.R.2
  • 8
    • 0026231953 scopus 로고
    • Antifibrin scintigraphy in the diagnostic evaluation of acute deep venous thrombosis
    • Schaible TF, Alavi A. Antifibrin scintigraphy in the diagnostic evaluation of acute deep venous thrombosis. Semin Nucl Med 1991;4:313-324.
    • (1991) Semin Nucl Med , vol.4 , pp. 313-324
    • Schaible, T.F.1    Alavi, A.2
  • 10
    • 0029392419 scopus 로고
    • Bilateral lower-extremity US for deep venous thrombosis
    • Blebea J, Strothman G, Fowl R. Bilateral lower-extremity US for deep venous thrombosis. Radiology 1995;197:315-316.
    • (1995) Radiology , vol.197 , pp. 315-316
    • Blebea, J.1    Strothman, G.2    Fowl, R.3
  • 11
    • 0028071019 scopus 로고
    • Diagnosis of acute deep venous thrombosis of the lower extremities: Prospective evaluation of color Doppler flow imaging versus venography
    • Lewis BD, James EM, Welch TJ, Joyce JW, Hallett JW, Weaver AL. Diagnosis of acute deep venous thrombosis of the lower extremities: prospective evaluation of color Doppler flow imaging versus venography. Radiology 1994; 192:651-655.
    • (1994) Radiology , vol.192 , pp. 651-655
    • Lewis, B.D.1    James, E.M.2    Welch, T.J.3    Joyce, J.W.4    Hallett, J.W.5    Weaver, A.L.6
  • 12
    • 0029282285 scopus 로고
    • Diagnosis of acute deep venous thrombosis of the lower extremities: Prospective evaluation of color Doppler flow imaging versus venography
    • Abstr.
    • Tschersich HU. Diagnosis of acute deep venous thrombosis of the lower extremities: prospective evaluation of color Doppler flow imaging versus venography. (Abstr.) Radiology 1995;195:289.
    • (1995) Radiology , vol.195 , pp. 289
    • Tschersich, H.U.1
  • 13
    • 22644447420 scopus 로고    scopus 로고
    • Iodixanol in leg phlebography: Randomized, double-blind parallel group phase III trial comparing iodixanol to ioxaglate
    • Sapoval MR, Beyssen BM, Girardot C, Musset MA, Legmann P, Brekke O, Gaux JC. Iodixanol in leg phlebography: randomized, double-blind parallel group phase III trial comparing iodixanol to ioxaglate. Clin Radio 1996;51: 210-213.
    • (1996) Clin Radio , vol.51 , pp. 210-213
    • Sapoval, M.R.1    Beyssen, B.M.2    Girardot, C.3    Musset, M.A.4    Legmann, P.5    Brekke, O.6    Gaux, J.C.7
  • 14
    • 0029347649 scopus 로고
    • Immediate and delayed tolerance of iohexol and ioxaglate in lower limb phlebography: Double-blind comparative study in humans
    • Bertrand P, Delhommais A, Alison D, Rouleau P. Immediate and delayed tolerance of iohexol and ioxaglate in lower limb phlebography: double-blind comparative study in humans. Acad Radiol 1995;2:683-686.
    • (1995) Acad Radiol , vol.2 , pp. 683-686
    • Bertrand, P.1    Delhommais, A.2    Alison, D.3    Rouleau, P.4
  • 16
    • 0002991888 scopus 로고    scopus 로고
    • MRX 115, an echocardiographic contrast agent, produces myocardial opacification after intravenous injection in primates: Studies before and after occlusion of left anterior descending coronary artery
    • Grauer SE, Xu J, Pantely GA, Ge S, Gong Z, Shiota T, Zhou X, Sahn DJ. MRX 115, an echocardiographic contrast agent, produces myocardial opacification after intravenous injection in primates: studies before and after occlusion of left anterior descending coronary artery. Acad Radiol 1996;3: S405-S406.
    • (1996) Acad Radiol , vol.3
    • Grauer, S.E.1    Xu, J.2    Pantely, G.A.3    Ge, S.4    Gong, Z.5    Shiota, T.6    Zhou, X.7    Sahn, D.J.8
  • 19