메뉴 건너뛰기




Volumn 135, Issue 5, 2009, Pages 564.e1-564.e19

Mini-implants in orthodontics: A systematic review of the literature

Author keywords

[No Author keywords available]

Indexed keywords


EID: 65249139979     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2008.09.026     Document Type: Article
Times cited : (192)

References (94)
  • 1
    • 0025333345 scopus 로고
    • Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
    • Roberts W.E., Marshall K.J., and Mozsary P.G. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 60 (1990) 135-152
    • (1990) Angle Orthod , vol.60 , pp. 135-152
    • Roberts, W.E.1    Marshall, K.J.2    Mozsary, P.G.3
  • 2
    • 0032249071 scopus 로고    scopus 로고
    • Aspects of the use of endosseous palatal implants in orthodontic therapy
    • Wehrbein H., and Merz B.R. Aspects of the use of endosseous palatal implants in orthodontic therapy. J Esthet Dent 10 (1998) 315-324
    • (1998) J Esthet Dent , vol.10 , pp. 315-324
    • Wehrbein, H.1    Merz, B.R.2
  • 3
    • 0020740361 scopus 로고
    • Studies on the efficacy of implants as orthodontic anchorage
    • Gray J.B., Steen M.E., King G.J., and Clark A.E. Studies on the efficacy of implants as orthodontic anchorage. Am J Orthod 83 (1983) 311-317
    • (1983) Am J Orthod , vol.83 , pp. 311-317
    • Gray, J.B.1    Steen, M.E.2    King, G.J.3    Clark, A.E.4
  • 5
    • 0024846195 scopus 로고
    • Rigid endosseous implants for orthodontic and orthopedic anchorage
    • Roberts W.E., Helm F.R., Marshall K.J., and Gongloff R.K. Rigid endosseous implants for orthodontic and orthopedic anchorage. Angle Orthod 59 (1989) 247-256
    • (1989) Angle Orthod , vol.59 , pp. 247-256
    • Roberts, W.E.1    Helm, F.R.2    Marshall, K.J.3    Gongloff, R.K.4
  • 6
    • 77956981059 scopus 로고
    • Osseointegrated titanium implants: a new approach in orthodontic treatment
    • Ödman J., Lekholm U., Jemt T., Brånemark P.I., and Thilander B. Osseointegrated titanium implants: a new approach in orthodontic treatment. Eur J Orthod 10 (1988) 98-105
    • (1988) Eur J Orthod , vol.10 , pp. 98-105
    • Ödman, J.1    Lekholm, U.2    Jemt, T.3    Brånemark, P.I.4    Thilander, B.5
  • 8
    • 0035344075 scopus 로고    scopus 로고
    • A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog
    • Ohmae M., Saito S., Morohashi T., Seki K., Qu H., Kanomi R., et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop 119 (2001) 489-497
    • (2001) Am J Orthod Dentofacial Orthop , vol.119 , pp. 489-497
    • Ohmae, M.1    Saito, S.2    Morohashi, T.3    Seki, K.4    Qu, H.5    Kanomi, R.6
  • 9
    • 14544304073 scopus 로고    scopus 로고
    • Temporary anchorage devices in orthodontics: a paradigm shift
    • Cope J.B. Temporary anchorage devices in orthodontics: a paradigm shift. Semin Orthod 11 (2005) 3-9
    • (2005) Semin Orthod , vol.11 , pp. 3-9
    • Cope, J.B.1
  • 10
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 11
    • 33847671933 scopus 로고    scopus 로고
    • L'ancrage intra-osseux en orthodontie à l'aide de mini-et de microvis
    • Berens A., Wiechmann D., and Rudiger J. L'ancrage intra-osseux en orthodontie à l'aide de mini-et de microvis. Int Orthod 3 (2005) 235-243
    • (2005) Int Orthod , vol.3 , pp. 235-243
    • Berens, A.1    Wiechmann, D.2    Rudiger, J.3
  • 14
    • 0035432240 scopus 로고    scopus 로고
    • Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications
    • Freudenthaler J.W., Haas R., and Bantleon H.P. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res 12 (2001) 358-363
    • (2001) Clin Oral Implants Res , vol.12 , pp. 358-363
    • Freudenthaler, J.W.1    Haas, R.2    Bantleon, H.P.3
  • 15
    • 4844229252 scopus 로고    scopus 로고
    • Clinical suitability of titanium miniscrews for orthodontic anchorage-preliminary experiences
    • Fritz U., Ehmer A., and Diedrich P. Clinical suitability of titanium miniscrews for orthodontic anchorage-preliminary experiences. J Orofac Orthop 65 (2004) 410-418
    • (2004) J Orofac Orthop , vol.65 , pp. 410-418
    • Fritz, U.1    Ehmer, A.2    Diedrich, P.3
  • 16
    • 33646557306 scopus 로고    scopus 로고
    • Implantable devices as orthodontic anchorage: a review of current treatment modalities
    • Heymann G.C., and Tulloch J.F. Implantable devices as orthodontic anchorage: a review of current treatment modalities. J Esthet Restor Dent 18 (2006) 68-80
    • (2006) J Esthet Restor Dent , vol.18 , pp. 68-80
    • Heymann, G.C.1    Tulloch, J.F.2
  • 17
  • 19
    • 20544455939 scopus 로고    scopus 로고
    • Temporary anchorage devices: a status report
    • Mah J., and Bergstrand F. Temporary anchorage devices: a status report. J Clin Orthod 39 (2005) 132-136
    • (2005) J Clin Orthod , vol.39 , pp. 132-136
    • Mah, J.1    Bergstrand, F.2
  • 20
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 21
    • 3042598772 scopus 로고    scopus 로고
    • Do miniscrews remain stationary under orthodontic forces?
    • Liou E.J., Pai B.C., and Lin J.C. Do miniscrews remain stationary under orthodontic forces?. Am J Orthod Dentofacial Orthop 126 (2004) 42-47
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 42-47
    • Liou, E.J.1    Pai, B.C.2    Lin, J.C.3
  • 22
    • 33645054577 scopus 로고    scopus 로고
    • Recommended placement torque when tightening an orthodontic mini-implant
    • Motoyoshi M., Hirabayashi M., Uemura M., and Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17 (2006) 109-114
    • (2006) Clin Oral Implants Res , vol.17 , pp. 109-114
    • Motoyoshi, M.1    Hirabayashi, M.2    Uemura, M.3    Shimizu, N.4
  • 23
    • 33646037315 scopus 로고    scopus 로고
    • Comparison and measurement of the amount of anchorage loss of the molars with and without the use of implant anchorage during canine retraction
    • Thiruvenkatachari B., Pavithranand A., Rajasigamani K., and Kyung H.M. Comparison and measurement of the amount of anchorage loss of the molars with and without the use of implant anchorage during canine retraction. Am J Orthod Dentofacial Orthop 129 (2006) 551-554
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 551-554
    • Thiruvenkatachari, B.1    Pavithranand, A.2    Rajasigamani, K.3    Kyung, H.M.4
  • 24
    • 33745835122 scopus 로고    scopus 로고
    • Factors affecting the clinical success of screw implants used as orthodontic anchorage
    • Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18-25
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 18-25
    • Park, H.S.1    Jeong, S.H.2    Kwon, O.W.3
  • 27
    • 33846627877 scopus 로고    scopus 로고
    • The use of temporary anchorage devices for molar intrusion
    • Kravitz N.D., Kusnoto B., Tsay T.P., and Hohlt W.F. The use of temporary anchorage devices for molar intrusion. J Am Dent Assoc 138 (2007) 56-64
    • (2007) J Am Dent Assoc , vol.138 , pp. 56-64
    • Kravitz, N.D.1    Kusnoto, B.2    Tsay, T.P.3    Hohlt, W.F.4
  • 28
    • 34548396403 scopus 로고    scopus 로고
    • A comparative evaluation of current orthodontic miniscrew systems
    • Lin J.C., Liou E.J., Yeh C.L., and Evans C.A. A comparative evaluation of current orthodontic miniscrew systems. World J Orthod 8 (2007) 136-144
    • (2007) World J Orthod , vol.8 , pp. 136-144
    • Lin, J.C.1    Liou, E.J.2    Yeh, C.L.3    Evans, C.A.4
  • 29
    • 44949219312 scopus 로고    scopus 로고
    • Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods
    • CD005098
    • Skeggs R.M., Benson P.E., and Dyer F. Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods. Cochrane Database Syst Rev 3 (2007 Jul 18) CD005098
    • (2007) Cochrane Database Syst Rev , Issue.3
    • Skeggs, R.M.1    Benson, P.E.2    Dyer, F.3
  • 30
    • 45849096488 scopus 로고    scopus 로고
    • Miniscrews of palatal implants for skeletal anchorage in the maxilla: comparative aspects for decision making
    • Wehrbein H., and Göllner P. Miniscrews of palatal implants for skeletal anchorage in the maxilla: comparative aspects for decision making. World J Orthod 9 (2008) 63-73
    • (2008) World J Orthod , vol.9 , pp. 63-73
    • Wehrbein, H.1    Göllner, P.2
  • 31
  • 32
    • 39049183891 scopus 로고    scopus 로고
    • Current products and practice. Bone anchorage devices in orthodontics
    • Prabhu J., and Cousley R.R.J. Current products and practice. Bone anchorage devices in orthodontics. J Orthod 33 (2006) 288-307
    • (2006) J Orthod , vol.33 , pp. 288-307
    • Prabhu, J.1    Cousley, R.R.J.2
  • 33
    • 33746018652 scopus 로고    scopus 로고
    • Implant vs screw loading protocols in orthodontics
    • Ohashi E., Pecho O.E., Moron M., and Lagravere M.O. Implant vs screw loading protocols in orthodontics. Angle Orthod 76 (2006) 721-727
    • (2006) Angle Orthod , vol.76 , pp. 721-727
    • Ohashi, E.1    Pecho, O.E.2    Moron, M.3    Lagravere, M.O.4
  • 35
    • 84887346660 scopus 로고    scopus 로고
    • Higgins JPT, Green S, editiors. Cochrane Handbook for Systematic Reviews of Interventions 5.0.0. (updated February 2008). The Cochrane Collaboration, 2008. Available at: www.cochrane-handbook.org.
    • Higgins JPT, Green S, editiors. Cochrane Handbook for Systematic Reviews of Interventions 5.0.0. (updated February 2008). The Cochrane Collaboration, 2008. Available at: www.cochrane-handbook.org.
  • 36
    • 29144494962 scopus 로고    scopus 로고
    • CONSORT and QUORUM guidelines for reporting randomized clinical trials and systematic reviews
    • Turpin D.L. CONSORT and QUORUM guidelines for reporting randomized clinical trials and systematic reviews. Am J Orthod Dentofacial Orthop 128 (2005) 681-685
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 681-685
    • Turpin, D.L.1
  • 37
    • 34447294838 scopus 로고    scopus 로고
    • A prospective clinical investigation of the failure rate of immediately loaded mini-implants used for orthodontic anchorage
    • Luzi C., Verna C., and Melsen B. A prospective clinical investigation of the failure rate of immediately loaded mini-implants used for orthodontic anchorage. Prog Orthod 8 (2007) 192-201
    • (2007) Prog Orthod , vol.8 , pp. 192-201
    • Luzi, C.1    Verna, C.2    Melsen, B.3
  • 38
  • 40
    • 38349009101 scopus 로고    scopus 로고
    • Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region
    • Moon C.H., Lee D.G., Lee H.S., Im J.S., and Baek S.H. Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region. Angle Orthod 78 (2008) 101-106
    • (2008) Angle Orthod , vol.78 , pp. 101-106
    • Moon, C.H.1    Lee, D.G.2    Lee, H.S.3    Im, J.S.4    Baek, S.H.5
  • 41
    • 33847689704 scopus 로고    scopus 로고
    • Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study
    • Wiechmann D., Meyer U., and Büchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 18 (2007) 263-267
    • (2007) Clin Oral Implants Res , vol.18 , pp. 263-267
    • Wiechmann, D.1    Meyer, U.2    Büchter, A.3
  • 43
    • 35649012521 scopus 로고    scopus 로고
    • Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants
    • Motoyoshi M., Yoshida T., Ono A., and Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22 (2007) 779-784
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 779-784
    • Motoyoshi, M.1    Yoshida, T.2    Ono, A.3    Shimizu, N.4
  • 45
    • 38349001355 scopus 로고    scopus 로고
    • Influence of surface characteristics on survival rates of mini-implants
    • Chaddad K., Ferreira A.F., Geurs N., and Reddy M.S. Influence of surface characteristics on survival rates of mini-implants. Angle Orthod 78 (2008) 107-113
    • (2008) Angle Orthod , vol.78 , pp. 107-113
    • Chaddad, K.1    Ferreira, A.F.2    Geurs, N.3    Reddy, M.S.4
  • 46
    • 37849189156 scopus 로고    scopus 로고
    • Mini- and micro-screws for temporary skeletal anchorage in orthodontic therapy
    • Berens A., Wiechmann D., and Dempf R. Mini- and micro-screws for temporary skeletal anchorage in orthodontic therapy. J Orofac Orthop 67 (2006) 450-458
    • (2006) J Orofac Orthop , vol.67 , pp. 450-458
    • Berens, A.1    Wiechmann, D.2    Dempf, R.3
  • 47
    • 41849105781 scopus 로고    scopus 로고
    • Anchorage efficacy of palatally-inserted miniscrews in molar distalization with a periodontally/miniscrew-anchored distal jet
    • Kinzinger G., Gulden N., Yildizhan F., Hermanns-Sachweh B., and Diedrich P. Anchorage efficacy of palatally-inserted miniscrews in molar distalization with a periodontally/miniscrew-anchored distal jet. J Orofac Orthop 69 (2008) 110-120
    • (2008) J Orofac Orthop , vol.69 , pp. 110-120
    • Kinzinger, G.1    Gulden, N.2    Yildizhan, F.3    Hermanns-Sachweh, B.4    Diedrich, P.5
  • 50
    • 34249887658 scopus 로고    scopus 로고
    • Weighing up the evidence
    • Ledford H. Weighing up the evidence. Nature 447 (2007) 512-513
    • (2007) Nature , vol.447 , pp. 512-513
    • Ledford, H.1
  • 51
    • 34247167529 scopus 로고    scopus 로고
    • Risks and complications of orthodontic miniscrews
    • Kravitz N.D., and Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 131 4 Suppl (2007) S43-S51
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , Issue.4 SUPPL
    • Kravitz, N.D.1    Kusnoto, B.2
  • 52
    • 37449004200 scopus 로고    scopus 로고
    • Comparison of the loading behavior of self-drilling and predrilled miniscrews throughout orthodontic loading
    • Wang Y.C., and Liou E.J. Comparison of the loading behavior of self-drilling and predrilled miniscrews throughout orthodontic loading. Am J Orthod Dentofacial Orthop 133 (2008) 38-43
    • (2008) Am J Orthod Dentofacial Orthop , vol.133 , pp. 38-43
    • Wang, Y.C.1    Liou, E.J.2
  • 54
    • 37249035998 scopus 로고    scopus 로고
    • Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study
    • Chen Y.H., Chang H.H., Chen Y.J., Lee D., Chiang H.H., and Yao C.C. Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study. Clin Oral Implants Res 19 (2008) 99-106
    • (2008) Clin Oral Implants Res , vol.19 , pp. 99-106
    • Chen, Y.H.1    Chang, H.H.2    Chen, Y.J.3    Lee, D.4    Chiang, H.H.5    Yao, C.C.6
  • 56
    • 0035259306 scopus 로고    scopus 로고
    • The influences of molar intrusion on the inferior alveolar neurovascular bundle and root using the skeletal anchorage system in dogs
    • Daimaruya T., Nagasaka H., Umemori M., Sugawara J., and Mitani H. The influences of molar intrusion on the inferior alveolar neurovascular bundle and root using the skeletal anchorage system in dogs. Angle Orthod 71 (2001) 60-70
    • (2001) Angle Orthod , vol.71 , pp. 60-70
    • Daimaruya, T.1    Nagasaka, H.2    Umemori, M.3    Sugawara, J.4    Mitani, H.5
  • 57
    • 33845413000 scopus 로고    scopus 로고
    • Tapered orthodontic miniscrews induce bone-screw cohesion following immediate loading
    • Yano S., Motoyoshi M., Uemura M., Ono A., and Shimizu N. Tapered orthodontic miniscrews induce bone-screw cohesion following immediate loading. Eur J Orthod 28 (2006) 541-546
    • (2006) Eur J Orthod , vol.28 , pp. 541-546
    • Yano, S.1    Motoyoshi, M.2    Uemura, M.3    Ono, A.4    Shimizu, N.5
  • 58
    • 26944457438 scopus 로고    scopus 로고
    • Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis
    • Motoyoshi M., Yano S., Tsuruoka T., and Shimizu N. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis. Clin Oral Implants Res 16 (2005) 480-485
    • (2005) Clin Oral Implants Res , vol.16 , pp. 480-485
    • Motoyoshi, M.1    Yano, S.2    Tsuruoka, T.3    Shimizu, N.4
  • 59
    • 37649004793 scopus 로고    scopus 로고
    • Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness
    • Song Y.Y., Cha J.Y., and Hwang C.J. Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod 77 (2007) 979-985
    • (2007) Angle Orthod , vol.77 , pp. 979-985
    • Song, Y.Y.1    Cha, J.Y.2    Hwang, C.J.3
  • 60
    • 0035689180 scopus 로고    scopus 로고
    • Fine thread versus coarse thread. A comparison of the maximum holding power
    • Gausepohl T., Möhring R., Pennig D., and Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power. Injury 32 Suppl 4 (2001) SD1-SD7
    • (2001) Injury , vol.32 , Issue.SUPPL. 4
    • Gausepohl, T.1    Möhring, R.2    Pennig, D.3    Koebke, J.4
  • 61
    • 38649127843 scopus 로고    scopus 로고
    • Impact of implant design on primary stability of orthodontic mini-implants
    • Wilmes B., Ottenstreuer S., Su Y.Y., and Drescher D. Impact of implant design on primary stability of orthodontic mini-implants. J Orofac Orthop 69 (2008) 42-50
    • (2008) J Orofac Orthop , vol.69 , pp. 42-50
    • Wilmes, B.1    Ottenstreuer, S.2    Su, Y.Y.3    Drescher, D.4
  • 62
    • 33744458766 scopus 로고    scopus 로고
    • Parameters affecting primary stability of orthodontic mini-implants
    • Wilmes B., Rademacher C., Olthoff G., and Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67 (2006) 162-174
    • (2006) J Orofac Orthop , vol.67 , pp. 162-174
    • Wilmes, B.1    Rademacher, C.2    Olthoff, G.3    Drescher, D.4
  • 63
    • 32944471409 scopus 로고    scopus 로고
    • Mini-implants: where are we?
    • Melsen B. Mini-implants: where are we?. J Clin Orthod 39 (2005) 539-547
    • (2005) J Clin Orthod , vol.39 , pp. 539-547
    • Melsen, B.1
  • 64
    • 21444451316 scopus 로고    scopus 로고
    • Mechanical properties of three different commercially available miniscrews for skeletal anchorage
    • Carano A., Lonardo P., Velo S., and Incorvati C. Mechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod 6 (2005) 82-97
    • (2005) Prog Orthod , vol.6 , pp. 82-97
    • Carano, A.1    Lonardo, P.2    Velo, S.3    Incorvati, C.4
  • 65
    • 16644381734 scopus 로고    scopus 로고
    • Clinical applications of the mini-screw-anchorage system (M.A.S.) in the maxillary alveolar bone
    • Carano A., Velo S., Incorvati C., and Poggio P. Clinical applications of the mini-screw-anchorage system (M.A.S.) in the maxillary alveolar bone. Prog Orthod 5 (2004) 212-235
    • (2004) Prog Orthod , vol.5 , pp. 212-235
    • Carano, A.1    Velo, S.2    Incorvati, C.3    Poggio, P.4
  • 66
    • 14544272341 scopus 로고    scopus 로고
    • Miniscrew implants: the spider screw anchorage system
    • Maino B.G., Mura P., and Bednar J. Miniscrew implants: the spider screw anchorage system. Semin Orthod 11 (2005) 40-46
    • (2005) Semin Orthod , vol.11 , pp. 40-46
    • Maino, B.G.1    Mura, P.2    Bednar, J.3
  • 67
    • 13244284696 scopus 로고    scopus 로고
    • Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment
    • Hong R.K., Heo J.M., and Ha Y.K. Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment. Angle Orthod 75 (2005) 129-141
    • (2005) Angle Orthod , vol.75 , pp. 129-141
    • Hong, R.K.1    Heo, J.M.2    Ha, Y.K.3
  • 69
    • 41249094461 scopus 로고    scopus 로고
    • Cortical bone thickness in the buccal posterior region for orthodontic mini-implants
    • Ono A., Motoyoshi M., and Shimizu N. Cortical bone thickness in the buccal posterior region for orthodontic mini-implants. Int J Oral Maxillofac Surg 37 (2008) 334-340
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 334-340
    • Ono, A.1    Motoyoshi, M.2    Shimizu, N.3
  • 71
    • 16544393095 scopus 로고    scopus 로고
    • The C-orthodontic micro-implant
    • Chung K.R., Kim S.H., and Kook Y.A. The C-orthodontic micro-implant. J Clin Orthod 38 (2004) 478-486
    • (2004) J Clin Orthod , vol.38 , pp. 478-486
    • Chung, K.R.1    Kim, S.H.2    Kook, Y.A.3
  • 73
    • 33748913160 scopus 로고    scopus 로고
    • Osteonecrosis of the jaws by long-term therapy with bisphosphonates
    • Piesold J.U., Al-Nawas B., and Grotz K.A. Osteonecrosis of the jaws by long-term therapy with bisphosphonates. Mund Kiefer Gesichtschir 10 (2006) 287-300
    • (2006) Mund Kiefer Gesichtschir , vol.10 , pp. 287-300
    • Piesold, J.U.1    Al-Nawas, B.2    Grotz, K.A.3
  • 74
    • 37649013582 scopus 로고    scopus 로고
    • Osseointegrated implants in subjects treated for generalized aggressive periodontitis: 10-year results of a prospective, long-term cohort study
    • Mengel R., Behle M., and Flores-de-Jacoby L. Osseointegrated implants in subjects treated for generalized aggressive periodontitis: 10-year results of a prospective, long-term cohort study. J Periodontol 78 (2007) 2229-2237
    • (2007) J Periodontol , vol.78 , pp. 2229-2237
    • Mengel, R.1    Behle, M.2    Flores-de-Jacoby, L.3
  • 76
    • 14544287285 scopus 로고    scopus 로고
    • Miniscrew implants: the Aarhus anchorage system
    • Melsen B., and Verna C. Miniscrew implants: the Aarhus anchorage system. Semin Orthod 11 (2005) 24-31
    • (2005) Semin Orthod , vol.11 , pp. 24-31
    • Melsen, B.1    Verna, C.2
  • 77
    • 1342308955 scopus 로고    scopus 로고
    • A new bone screw for orthodontic anchorage
    • Lin J.C., and Liou E.J. A new bone screw for orthodontic anchorage. J Clin Orthod 37 (2003) 676-681
    • (2003) J Clin Orthod , vol.37 , pp. 676-681
    • Lin, J.C.1    Liou, E.J.2
  • 78
    • 14544296122 scopus 로고    scopus 로고
    • Intraoral hard and soft tissue depths for temporary anchorage devices
    • Costa A., Pasta G., and Bergamaschi G. Intraoral hard and soft tissue depths for temporary anchorage devices. Semin Orthod 11 (2005) 10-15
    • (2005) Semin Orthod , vol.11 , pp. 10-15
    • Costa, A.1    Pasta, G.2    Bergamaschi, G.3
  • 79
    • 0023968448 scopus 로고
    • Bone-implant interface structures after nontapping and tapping insertion of screw-type titanium alloy endosseous implants
    • Satomi K., Akagawa Y., Nikai H., and Tsuru H. Bone-implant interface structures after nontapping and tapping insertion of screw-type titanium alloy endosseous implants. J Prosthet Dent 59 (1988) 339-342
    • (1988) J Prosthet Dent , vol.59 , pp. 339-342
    • Satomi, K.1    Akagawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 80
    • 0021685213 scopus 로고
    • The effect of heat on bone generation: an experimental study in the rabbit using the bone growth chamber
    • Eriksson R.A., and Albrektsson T. The effect of heat on bone generation: an experimental study in the rabbit using the bone growth chamber. J Oral Maxillofac Surg 42 (1984) 705-711
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 81
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: a vital microscopic study in the rabbit
    • Eriksson R.A., and Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital microscopic study in the rabbit. J Prosthet Dent 50 (1983) 101-107
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, R.A.1    Albrektsson, T.2
  • 82
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 (1998) 491-501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 83
    • 3042596572 scopus 로고    scopus 로고
    • Treatment of ectopic mandibular second molar with titanium miniscrews
    • Giancotti A., Arcuri C., and Barlattani A. Treatment of ectopic mandibular second molar with titanium miniscrews. Am J Orthod Dentofacial Orthop 126 (2004) 113-117
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 113-117
    • Giancotti, A.1    Arcuri, C.2    Barlattani, A.3
  • 84
    • 21444457307 scopus 로고    scopus 로고
    • Spider screw: skeletal anchorage system
    • Maino B.G., Maino G., and Mura P. Spider screw: skeletal anchorage system. Prog Orthod 6 (2005) 70-81
    • (2005) Prog Orthod , vol.6 , pp. 70-81
    • Maino, B.G.1    Maino, G.2    Mura, P.3
  • 85
    • 0018564497 scopus 로고
    • The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects
    • Brunski J.B., Moccia Jr. A.F., Pollack S.R., Korostoff E., and Trachtenberg D.I. The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects. J Dent Res 58 (1979) 1953-1969
    • (1979) J Dent Res , vol.58 , pp. 1953-1969
    • Brunski, J.B.1    Moccia Jr., A.F.2    Pollack, S.R.3    Korostoff, E.4    Trachtenberg, D.I.5
  • 86
    • 0019414459 scopus 로고
    • The reactions of bone, connective tissue, and eptithelium to endosteal implants with titanium-sprayed surfaces
    • Schroeder A., van der Zypen E., Stich H., and Sutter F. The reactions of bone, connective tissue, and eptithelium to endosteal implants with titanium-sprayed surfaces. J Maxillofac Surg 9 (1981) 15-25
    • (1981) J Maxillofac Surg , vol.9 , pp. 15-25
    • Schroeder, A.1    van der Zypen, E.2    Stich, H.3    Sutter, F.4
  • 87
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature
    • Szmukler-Moncler S., Salama H., Reingewirtz Y., and Dubruille J.H. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43 (1998) 192-203
    • (1998) J Biomed Mater Res , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 88
    • 23344442786 scopus 로고    scopus 로고
    • Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage
    • Kim J.W., Ahn S.J., and Chang Y.I. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 128 (2005) 190-194
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 190-194
    • Kim, J.W.1    Ahn, S.J.2    Chang, Y.I.3
  • 90
    • 34248340063 scopus 로고    scopus 로고
    • Analysis of stress and strain around orthodontically loaded implants: an animal study
    • Cattaneo P.M., Dalstra M., and Melsen B. Analysis of stress and strain around orthodontically loaded implants: an animal study. Int J Oral Maxillofac Implants 22 (2007) 213-225
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 213-225
    • Cattaneo, P.M.1    Dalstra, M.2    Melsen, B.3
  • 91
    • 14544272069 scopus 로고    scopus 로고
    • Load transfer of miniscrews for orthodontic anchorage
    • Dalstra M., Cattaneo P.M., and Melsen B. Load transfer of miniscrews for orthodontic anchorage. Orthodontics 1 (2004) 53-62
    • (2004) Orthodontics , vol.1 , pp. 53-62
    • Dalstra, M.1    Cattaneo, P.M.2    Melsen, B.3
  • 92
    • 14544303622 scopus 로고    scopus 로고
    • Miniscrew implants: IMTEC mini ortho implants
    • Herman R., and Cope J.B. Miniscrew implants: IMTEC mini ortho implants. Semin Orthod 11 (2005) 32-39
    • (2005) Semin Orthod , vol.11 , pp. 32-39
    • Herman, R.1    Cope, J.B.2
  • 93
    • 0034853307 scopus 로고    scopus 로고
    • The effect of right or left-handedness on oral hygiene
    • Tezel A., Orbak R., and Canakci V. The effect of right or left-handedness on oral hygiene. Int J Neurosci 109 (2001) 1-9
    • (2001) Int J Neurosci , vol.109 , pp. 1-9
    • Tezel, A.1    Orbak, R.2    Canakci, V.3
  • 94
    • 0027683837 scopus 로고
    • Avoid pitfalls of overloading and micromotion of intraosseous implants
    • Brunski J.B. Avoid pitfalls of overloading and micromotion of intraosseous implants. Dent Implantol Update 4 (1993) 77-81
    • (1993) Dent Implantol Update , vol.4 , pp. 77-81
    • Brunski, J.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.