메뉴 건너뛰기




Volumn 130, Issue 1, 2006, Pages 18-25

Factors affecting the clinical success of screw implants used as orthodontic anchorage

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BONE SCREW; ELECTRONICS; EQUIPMENT; EQUIPMENT DESIGN; FEMALE; HUMAN; INFLAMMATION; INSTRUMENTATION; MALE; ORTHODONTICS; RISK; RISK FACTOR; STATISTICAL MODEL; TOOTH IMPLANTATION; TREATMENT OUTCOME;

EID: 33745835122     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2004.11.032     Document Type: Article
Times cited : (456)

References (27)
  • 2
    • 0020739585 scopus 로고
    • The possibility of skeletal anchorage
    • Creekmore T.D., and Eklund M.K. The possibility of skeletal anchorage. J Clin Orthod 17 (1983) 266-269
    • (1983) J Clin Orthod , vol.17 , pp. 266-269
    • Creekmore, T.D.1    Eklund, M.K.2
  • 4
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 5
    • 7044273408 scopus 로고    scopus 로고
    • The skeletal cortical anchorage using titanium microscrew implants
    • Park H.S. The skeletal cortical anchorage using titanium microscrew implants. Korean J Orthod 29 (1999) 699-706
    • (1999) Korean J Orthod , vol.29 , pp. 699-706
    • Park, H.S.1
  • 7
    • 4444249537 scopus 로고    scopus 로고
    • Nonextraction treatment with microscrew implants
    • Park H.S., Kwon T.G., and Sung J.H. Nonextraction treatment with microscrew implants. Angle Orthod 74 (2004) 539-549
    • (2004) Angle Orthod , vol.74 , pp. 539-549
    • Park, H.S.1    Kwon, T.G.2    Sung, J.H.3
  • 9
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 11
    • 32644476336 scopus 로고    scopus 로고
    • Clinical study on success rate of microscrew implants for orthodontic anchorage
    • Park H.S. Clinical study on success rate of microscrew implants for orthodontic anchorage. Korean J Orthod 33 (2003) 151-156
    • (2003) Korean J Orthod , vol.33 , pp. 151-156
    • Park, H.S.1
  • 12
    • 0035344075 scopus 로고    scopus 로고
    • A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog
    • Ohmae M., Saito S., Morohashi T., Seki K., Qu H., Kanomi R., et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop 119 (2001) 489-497
    • (2001) Am J Orthod Dentofacial Orthop , vol.119 , pp. 489-497
    • Ohmae, M.1    Saito, S.2    Morohashi, T.3    Seki, K.4    Qu, H.5    Kanomi, R.6
  • 14
    • 0031205159 scopus 로고    scopus 로고
    • Reintegration of mobilized titanium implants. An experimental study in rabbit tibia
    • Ivanoff C.J., Sennerby L., and Lekholm U. Reintegration of mobilized titanium implants. An experimental study in rabbit tibia. Int J Oral Maxillofac Surg 26 (1997) 310-315
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 310-315
    • Ivanoff, C.J.1    Sennerby, L.2    Lekholm, U.3
  • 15
    • 0033161184 scopus 로고    scopus 로고
    • Differential diagnosis and treatment strategies for biologic complications and failing oral implants. a review of the literature
    • Esposito M., Hirsch J., Lekholm U., and Thomsen P. Differential diagnosis and treatment strategies for biologic complications and failing oral implants. a review of the literature. Int J Oral Maxillofac Implants 14 (1999) 473-490
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 473-490
    • Esposito, M.1    Hirsch, J.2    Lekholm, U.3    Thomsen, P.4
  • 16
    • 0034853307 scopus 로고    scopus 로고
    • The effect of right or left-handedness on oral hygiene
    • Tezel A., Orbak R., and Canakci V. The effect of right or left-handedness on oral hygiene. Int J Neurosci 109 (2001) 1-9
    • (2001) Int J Neurosci , vol.109 , pp. 1-9
    • Tezel, A.1    Orbak, R.2    Canakci, V.3
  • 18
    • 4444301021 scopus 로고    scopus 로고
    • An anatomical study using CT images for the implantation of micro-implants
    • Park H.S. An anatomical study using CT images for the implantation of micro-implants. Korean J Orthod 32 (2002) 435-441
    • (2002) Korean J Orthod , vol.32 , pp. 435-441
    • Park, H.S.1
  • 19
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury. a vital-microscopic study in the rabbit
    • Eriksson A.R., and Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury. a vital-microscopic study in the rabbit. J Prosthet Dent 50 (1983) 101-107
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 20
    • 0032601842 scopus 로고    scopus 로고
    • Factors affecting heat generation during implant site preparation. a review of biologic observations and future considerations
    • Tehemar S.H. Factors affecting heat generation during implant site preparation. a review of biologic observations and future considerations. Int J Oral Maxillofac Implants 14 (1999) 127-136
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 127-136
    • Tehemar, S.H.1
  • 21
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews L.S., and Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg Am 54 (1972) 297-308
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 22
    • 6344294062 scopus 로고    scopus 로고
    • Spontaneous progression of experimentally induced peri-implantitis
    • Zitzmann N.U., Berglundh T., Ericsson I., and Lindhe J. Spontaneous progression of experimentally induced peri-implantitis. J Clin Periodontol 31 (2004) 845-849
    • (2004) J Clin Periodontol , vol.31 , pp. 845-849
    • Zitzmann, N.U.1    Berglundh, T.2    Ericsson, I.3    Lindhe, J.4
  • 25
    • 1042284432 scopus 로고    scopus 로고
    • Immediate loading of implants used for orthodontic anchorage
    • Melsen B., and Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3 (2000) 23-28
    • (2000) Clin Orthod Res , vol.3 , pp. 23-28
    • Melsen, B.1    Costa, A.2
  • 26
    • 0034927039 scopus 로고    scopus 로고
    • Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy. a study in sheep mandibles
    • Uckan S., Schwimmer A., Kummer F., and Greenberg A.M. Effect of the angle of the screw on the stability of the mandibular sagittal split ramus osteotomy. a study in sheep mandibles. Br J Oral Maxillofac Surg 39 (2001) 266-268
    • (2001) Br J Oral Maxillofac Surg , vol.39 , pp. 266-268
    • Uckan, S.1    Schwimmer, A.2    Kummer, F.3    Greenberg, A.M.4
  • 27
    • 0346461396 scopus 로고    scopus 로고
    • Influence of implant length and diameter on stress distribution. a finite element analysis
    • Himmlova L., Dostalova T., Kacovsky A., and Konvickova S. Influence of implant length and diameter on stress distribution. a finite element analysis. J Prosthet Dent 19 (2004) 20-25
    • (2004) J Prosthet Dent , vol.19 , pp. 20-25
    • Himmlova, L.1    Dostalova, T.2    Kacovsky, A.3    Konvickova, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.