메뉴 건너뛰기




Volumn 37, Issue 4, 2008, Pages 334-340

Cortical bone thickness in the buccal posterior region for orthodontic mini-implants

Author keywords

anchor; computed tomography; cortical bone thickness; orthodontics; screw

Indexed keywords

ADOLESCENT; ADULT; ALVEOLAR BONE; ARTICLE; CHEEK; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; FEMALE; GINGIVA; HUMAN; IMPLANTATION; MALE; MOLAR TOOTH; ORTHODONTICS; THICKNESS;

EID: 41249094461     PISSN: 09015027     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijom.2008.01.005     Document Type: Article
Times cited : (140)

References (21)
  • 2
    • 0000516670 scopus 로고
    • A study of the width of attached gingiva
    • Bowers G.M. A study of the width of attached gingiva. J Periodontol 34 (1962) 201-209
    • (1962) J Periodontol , vol.34 , pp. 201-209
    • Bowers, G.M.1
  • 3
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 5
    • 33744930120 scopus 로고    scopus 로고
    • Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants
    • 721.e7-721.e12
    • Deguchi T., Nasu M., Murakami K., Yabuuchi T., Kamioka H., and Takano-Yamamoto T. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofac Orthop 129 (2006) 721.e7-721.e12
    • (2006) Am J Orthod Dentofac Orthop , vol.129
    • Deguchi, T.1    Nasu, M.2    Murakami, K.3    Yabuuchi, T.4    Kamioka, H.5    Takano-Yamamoto, T.6
  • 6
    • 0035432240 scopus 로고    scopus 로고
    • Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications
    • Freudenthaler J.W., Bantleon H.P., and Haas R. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res 12 (2001) 358-363
    • (2001) Clin Oral Implants Res , vol.12 , pp. 358-363
    • Freudenthaler, J.W.1    Bantleon, H.P.2    Haas, R.3
  • 7
    • 3843123180 scopus 로고    scopus 로고
    • Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate
    • Gahleitner A., Podesser B., Schick S., Watzek G., and Imhof H. Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate. Eur J Orthod 51 (2004) 257-262
    • (2004) Eur J Orthod , vol.51 , pp. 257-262
    • Gahleitner, A.1    Podesser, B.2    Schick, S.3    Watzek, G.4    Imhof, H.5
  • 9
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 10
    • 0035492033 scopus 로고    scopus 로고
    • Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion
    • Lee J.S., Park H.S., and Kyung H.M. Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion. J Clin Orthod 35 (2001) 643-647
    • (2001) J Clin Orthod , vol.35 , pp. 643-647
    • Lee, J.S.1    Park, H.S.2    Kyung, H.M.3
  • 11
    • 0141921987 scopus 로고    scopus 로고
    • Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
    • Miyawaki S., Koyama I., Inoue M., Mishima K., Sugawara T., and Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofac Orthop 124 (2003) 373-378
    • (2003) Am J Orthod Dentofac Orthop , vol.124 , pp. 373-378
    • Miyawaki, S.1    Koyama, I.2    Inoue, M.3    Mishima, K.4    Sugawara, T.5    Yamamoto, T.6
  • 12
    • 33645054577 scopus 로고    scopus 로고
    • Recommended placement torque when tightening an orthodontic mini-implant
    • Motoyoshi M., Hirabayashi M., Uemura M., and Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17 (2006) 109-114
    • (2006) Clin Oral Implants Res , vol.17 , pp. 109-114
    • Motoyoshi, M.1    Hirabayashi, M.2    Uemura, M.3    Shimizu, N.4
  • 13
    • 35649012521 scopus 로고    scopus 로고
    • Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants
    • Motoyoshi M., Yoshida T., Ono A., and Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22 (2007) 779-784
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 779-784
    • Motoyoshi, M.1    Yoshida, T.2    Ono, A.3    Shimizu, N.4
  • 14
    • 0036777545 scopus 로고    scopus 로고
    • A simple method of molar uprighting with microimplant anchorage
    • Park H.S., Kyung H.M., and Sung J.H. A simple method of molar uprighting with microimplant anchorage. J Clin Orthod 36 (2002) 592-596
    • (2002) J Clin Orthod , vol.36 , pp. 592-596
    • Park, H.S.1    Kyung, H.M.2    Sung, J.H.3
  • 15
    • 4444249537 scopus 로고    scopus 로고
    • Non extraction treatment with microscrew implant
    • Park H.S., Kwon D.G., and Sung J.H. Non extraction treatment with microscrew implant. Angle Orthod 74 (2004) 539-549
    • (2004) Angle Orthod , vol.74 , pp. 539-549
    • Park, H.S.1    Kwon, D.G.2    Sung, J.H.3
  • 18
    • 0020073056 scopus 로고
    • A clinical study comparing the width of attached gingiva and the prevalence of gingival recessions
    • Tenenbaum H. A clinical study comparing the width of attached gingiva and the prevalence of gingival recessions. J Periodontol 9 (1982) 86-92
    • (1982) J Periodontol , vol.9 , pp. 86-92
    • Tenenbaum, H.1
  • 19
    • 0022706237 scopus 로고
    • A clinical study of the width of the attached gingiva in the deciduous, transitional and permanent dentitions
    • Tenenbaum H., and Tenembaum M. A clinical study of the width of the attached gingiva in the deciduous, transitional and permanent dentitions. J Periodontol 13 (1986) 270-275
    • (1986) J Periodontol , vol.13 , pp. 270-275
    • Tenenbaum, H.1    Tenembaum, M.2
  • 21
    • 41249099691 scopus 로고    scopus 로고
    • Morphological measurement of biologic width in Chinese people
    • Xie G.Y., Chen J.H., Wang H., and Wang Y.J. Morphological measurement of biologic width in Chinese people. J Oral Sci 49 (2007) 197-200
    • (2007) J Oral Sci , vol.49 , pp. 197-200
    • Xie, G.Y.1    Chen, J.H.2    Wang, H.3    Wang, Y.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.