-
1
-
-
33845385796
-
Accuracy of three-dimensional measurements using cone-beam CT
-
Pinsky H.M., Dyda S., Pinsky R.W., Misch K.A., and Sarment D.P. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofac Radiol 35 (2006) 410-416
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 410-416
-
-
Pinsky, H.M.1
Dyda, S.2
Pinsky, R.W.3
Misch, K.A.4
Sarment, D.P.5
-
2
-
-
0020122847
-
Factors influencing the radiographic appearance of bony lesions
-
Bender I.B. Factors influencing the radiographic appearance of bony lesions. J Endod 8 (1982) 161-170
-
(1982)
J Endod
, vol.8
, pp. 161-170
-
-
Bender, I.B.1
-
3
-
-
33846254175
-
Digital and advanced imaging in endodontics: a review
-
Nair M.K., and Nair U.P. Digital and advanced imaging in endodontics: a review. J Endod 33 (2007) 1-6
-
(2007)
J Endod
, vol.33
, pp. 1-6
-
-
Nair, M.K.1
Nair, U.P.2
-
5
-
-
34548552850
-
The potential applications of cone beam computed tomography in the management of endodontic problems
-
Patel S., Dawood A., Pitt Ford T., and Whaites E. The potential applications of cone beam computed tomography in the management of endodontic problems. Int Endod J 40 (2007) 818-830
-
(2007)
Int Endod J
, vol.40
, pp. 818-830
-
-
Patel, S.1
Dawood, A.2
Pitt Ford, T.3
Whaites, E.4
-
7
-
-
0038755182
-
A comparison of a new limited cone beam tomography for dental use with a multidetector row helical CT machine
-
371-37
-
Hashimoto K., Arai Y., Iwai K., Araki M., Kawashima S., and Terakado M. A comparison of a new limited cone beam tomography for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95 (2003) 371-37
-
(2003)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.95
-
-
Hashimoto, K.1
Arai, Y.2
Iwai, K.3
Araki, M.4
Kawashima, S.5
Terakado, M.6
-
8
-
-
33846198788
-
A comparative study of cone-beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars
-
Tantanapornkul W., Okouchi K., Fujiwara Y., Yamashiro M., Maruoka Y., Ohbayashi N., and Kurabayashi T. A comparative study of cone-beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) 253-259
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.103
, pp. 253-259
-
-
Tantanapornkul, W.1
Okouchi, K.2
Fujiwara, Y.3
Yamashiro, M.4
Maruoka, Y.5
Ohbayashi, N.6
Kurabayashi, T.7
-
9
-
-
14244256208
-
Using a flat-panel detector in high resolution con-beam CT for dental imaging
-
Baba R., Ueda K., and Okabe M. Using a flat-panel detector in high resolution con-beam CT for dental imaging. Dentomaxillofac Radiol 33 (2004) 285-290
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 285-290
-
-
Baba, R.1
Ueda, K.2
Okabe, M.3
-
10
-
-
0032240404
-
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
-
Mozzo P., Procacci C., Tacconi A., Martini P.T., and Andreis I.A.B. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8 (1998) 1558-1564
-
(1998)
Eur Radiol
, vol.8
, pp. 1558-1564
-
-
Mozzo, P.1
Procacci, C.2
Tacconi, A.3
Martini, P.T.4
Andreis, I.A.B.5
-
11
-
-
33644639722
-
Clinical applications of cone-beam computed tomography in dental practice
-
Scarfe W.C., Farman A.G., and Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 72 (2006) 75-80
-
(2006)
J Can Dent Assoc
, vol.72
, pp. 75-80
-
-
Scarfe, W.C.1
Farman, A.G.2
Sukovic, P.3
-
12
-
-
45949095409
-
Specialized radiographic techniques
-
White S.C., and Pharoah M.J. (Eds), Mosby, St. Louis
-
Frederiksen N.L. Specialized radiographic techniques. In: White S.C., and Pharoah M.J. (Eds). Oral radiology. Principles and interpretation. 5th ed. (2004), Mosby, St. Louis 245-264
-
(2004)
Oral radiology. Principles and interpretation. 5th ed.
, pp. 245-264
-
-
Frederiksen, N.L.1
-
13
-
-
0642365211
-
Cone beam computed tomography in craniofacial imaging
-
Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthod Craniofacial Res 6 (2003) 31-36
-
(2003)
Orthod Craniofacial Res
, vol.6
, pp. 31-36
-
-
Sukovic, P.1
-
14
-
-
0030252710
-
Interpretation of chemically created periapical lesions using direct digital imaging
-
Meier A.W., Brown C.E., Miles D.A., and Analoui M. Interpretation of chemically created periapical lesions using direct digital imaging. J Endod 22 (1996) 516-520
-
(1996)
J Endod
, vol.22
, pp. 516-520
-
-
Meier, A.W.1
Brown, C.E.2
Miles, D.A.3
Analoui, M.4
-
15
-
-
34249656423
-
Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws
-
Stavropoulos A., and Wenzel A. Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws. Clin Oral Invest 11 (2007) 101-106
-
(2007)
Clin Oral Invest
, vol.11
, pp. 101-106
-
-
Stavropoulos, A.1
Wenzel, A.2
-
16
-
-
0026451071
-
Direct digital radiography for the detection of periodontal bone lesions
-
Furkart A.J., Dove S.B., McDavid W.D., Nummikoski P., and Matteson S. Direct digital radiography for the detection of periodontal bone lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 74 (1992) 652-660
-
(1992)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.74
, pp. 652-660
-
-
Furkart, A.J.1
Dove, S.B.2
McDavid, W.D.3
Nummikoski, P.4
Matteson, S.5
-
17
-
-
0030225854
-
Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. Overall comparison between conventional and direct digital radiography
-
Kullendorff B., Nilsson M., and Rohlin M. Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. Overall comparison between conventional and direct digital radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 82 (1996) 344-350
-
(1996)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.82
, pp. 344-350
-
-
Kullendorff, B.1
Nilsson, M.2
Rohlin, M.3
-
18
-
-
0032250475
-
Detectability of artificial periapical lesions using direct digital and conventional radiography
-
Barbat J., and Messer H.H. Detectability of artificial periapical lesions using direct digital and conventional radiography. J Endod 24 (1998) 837-842
-
(1998)
J Endod
, vol.24
, pp. 837-842
-
-
Barbat, J.1
Messer, H.H.2
-
19
-
-
0032038164
-
Interpretation of periapical lesions comparing conventional, direct digital, and telephonically transmitted radiographic images
-
Mistak E.J., Loushine R.J., Primack P.D., West L.A., and Runyan D.A. Interpretation of periapical lesions comparing conventional, direct digital, and telephonically transmitted radiographic images. J Endod 24 (1998) 262-266
-
(1998)
J Endod
, vol.24
, pp. 262-266
-
-
Mistak, E.J.1
Loushine, R.J.2
Primack, P.D.3
West, L.A.4
Runyan, D.A.5
-
20
-
-
0032109730
-
Storage-phosphor computed radiography versus film radiography in the detection of pathologic periradicular bone loss in cadavers
-
Holtzmann D.J., Johnson W.T., Southard T.E., Khademi J.A., Chang P.J., and Rivera E.M. Storage-phosphor computed radiography versus film radiography in the detection of pathologic periradicular bone loss in cadavers. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 86 (1998) 90-97
-
(1998)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.86
, pp. 90-97
-
-
Holtzmann, D.J.1
Johnson, W.T.2
Southard, T.E.3
Khademi, J.A.4
Chang, P.J.5
Rivera, E.M.6
-
21
-
-
0034146665
-
Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions
-
Paurazas S.B., Geist J.R., Pink F.E., Hoen M.M., and Steiman H.R. Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89 (2000) 356-362
-
(2000)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.89
, pp. 356-362
-
-
Paurazas, S.B.1
Geist, J.R.2
Pink, F.E.3
Hoen, M.M.4
Steiman, H.R.5
-
22
-
-
17144415271
-
Comparison of two different direct digital radiography systems for the ability to detect artificially prepared periapical lesions
-
Folk R.B., Thorpe J.R., McClanahan S.B., Johnson J.D., and Strother J.M. Comparison of two different direct digital radiography systems for the ability to detect artificially prepared periapical lesions. J Endod 31 (2005) 304-306
-
(2005)
J Endod
, vol.31
, pp. 304-306
-
-
Folk, R.B.1
Thorpe, J.R.2
McClanahan, S.B.3
Johnson, J.D.4
Strother, J.M.5
-
23
-
-
0028524992
-
Interpretation of periapical lesions using radiovisiography
-
Yokota E.T., Miles D.A., Newton C.W., and Brown C.E. Interpretation of periapical lesions using radiovisiography. J Endod 20 (1994) 490-494
-
(1994)
J Endod
, vol.20
, pp. 490-494
-
-
Yokota, E.T.1
Miles, D.A.2
Newton, C.W.3
Brown, C.E.4
-
24
-
-
0030075153
-
Intrepretation of chemically created lesions using direct digital imaging
-
Tirrell B.C., Miles D.A., Brown C.E., and Legan J.J. Intrepretation of chemically created lesions using direct digital imaging. J Endod 22 (1996) 74-78
-
(1996)
J Endod
, vol.22
, pp. 74-78
-
-
Tirrell, B.C.1
Miles, D.A.2
Brown, C.E.3
Legan, J.J.4
-
25
-
-
0031197203
-
Direct digital radiography for the detection of periapical bone lesions: a clinical study
-
Kullendorff B., Petersson K., and Rohlin M. Direct digital radiography for the detection of periapical bone lesions: a clinical study. Dent Traumatol 13 (1997) 183-189
-
(1997)
Dent Traumatol
, vol.13
, pp. 183-189
-
-
Kullendorff, B.1
Petersson, K.2
Rohlin, M.3
-
26
-
-
0033741626
-
Radiovisiography in the detection of periapical lesions
-
Sullivan J.E., Di Fiore P.M., and Koerber A. Radiovisiography in the detection of periapical lesions. J Endod 26 (2000) 32-35
-
(2000)
J Endod
, vol.26
, pp. 32-35
-
-
Sullivan, J.E.1
Di Fiore, P.M.2
Koerber, A.3
-
27
-
-
0035405788
-
A comparative evaluation of the diagnostic efficacy of film and digital sensors for detection of simulated periapical lesions
-
Wallace J.A., Nair M.K., Colaco M.F., and Kapa S.F. A comparative evaluation of the diagnostic efficacy of film and digital sensors for detection of simulated periapical lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 92 (2001) 93-97
-
(2001)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.92
, pp. 93-97
-
-
Wallace, J.A.1
Nair, M.K.2
Colaco, M.F.3
Kapa, S.F.4
-
28
-
-
0030277660
-
Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. II. Effects on diagnostic accuracy after application of image processing
-
585-59
-
Kullendorff B., and Nilsson M. Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. II. Effects on diagnostic accuracy after application of image processing. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 82 (1996) 585-59
-
(1996)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.82
-
-
Kullendorff, B.1
Nilsson, M.2
-
29
-
-
33746041477
-
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, New Tom 3G and i-CAT
-
Ludlow J.B., Davies-Ludlow L.E., Brooks S.L., and Howerton W.B. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, New Tom 3G and i-CAT. Dentomaxillofac Radiol 35 (2006) 219-226
-
(2006)
Dentomaxillofac Radiol
, vol.35
, pp. 219-226
-
-
Ludlow, J.B.1
Davies-Ludlow, L.E.2
Brooks, S.L.3
Howerton, W.B.4
|