메뉴 건너뛰기




Volumn 27, Issue 2, 2007, Pages 190-193

Technical note: Accuracy and repeatability of a new portable ultrasound pachymeter

Author keywords

Corneal thickness; Pachymeter comparison; Portable ultrasound pachymetry

Indexed keywords

ADULT; ARTICLE; COMPARATIVE STUDY; CONFIDENCE INTERVAL; CONTROLLED STUDY; CORNEA THICKNESS; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PORTABLE EQUIPMENT; PRIORITY JOURNAL; ULTRASOUND;

EID: 33847208902     PISSN: 02755408     EISSN: 14751313     Source Type: Journal    
DOI: 10.1111/j.1475-1313.2006.00429.x     Document Type: Article
Times cited : (4)

References (20)
  • 1
    • 0038485796 scopus 로고    scopus 로고
    • The effects of overnight orthokeratology lens wear on corneal thickness
    • Alharbi, A. and Swarbrick, H. A. (2003) The effects of overnight orthokeratology lens wear on corneal thickness. Invest. Ophthalmol. Vis. Sci. 44, 2518-2523.
    • (2003) Invest. Ophthalmol. Vis. Sci , vol.44 , pp. 2518-2523
    • Alharbi, A.1    Swarbrick, H.A.2
  • 2
    • 23244449978 scopus 로고    scopus 로고
    • Overnight orthokeratology lens wear can inhibit the central stromal edema response
    • Alharbi, A., La Hood, D. and Swarbrick, H. A. (2005) Overnight orthokeratology lens wear can inhibit the central stromal edema response. Invest. Ophthalmol. Vis. Sci. 46, 2334-2340.
    • (2005) Invest. Ophthalmol. Vis. Sci , vol.46 , pp. 2334-2340
    • Alharbi, A.1    La Hood, D.2    Swarbrick, H.A.3
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J. M. and Altman, D. G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1, 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0032798810 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Topcon SP-2000P specular microscope and an ultrasound pachymeter
    • Bovelle, R., Kaufman, S. C., Thompson, H. W. and Hamano, H. (1999) Corneal thickness measurements with the Topcon SP-2000P specular microscope and an ultrasound pachymeter. Arch. Ophthalmol. 117, 868-870.
    • (1999) Arch. Ophthalmol , vol.117 , pp. 868-870
    • Bovelle, R.1    Kaufman, S.C.2    Thompson, H.W.3    Hamano, H.4
  • 5
    • 0036831268 scopus 로고    scopus 로고
    • Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure
    • Doughty, M. J., Laiquzzaman, M., Muller, A., Oblak, E. and Button, N. F. (2002) Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure. Ophthalmic Physiol. Opt. 22, 491-504.
    • (2002) Ophthalmic Physiol. Opt , vol.22 , pp. 491-504
    • Doughty, M.J.1    Laiquzzaman, M.2    Muller, A.3    Oblak, E.4    Button, N.F.5
  • 6
    • 0037378859 scopus 로고    scopus 로고
    • Diurnal variation of corneal sensitivity and thickness
    • Du, T. R., Vega, J. A., Fonn, D. and Simpson, T. (2003) Diurnal variation of corneal sensitivity and thickness. Cornea 22, 205-209.
    • (2003) Cornea , vol.22 , pp. 205-209
    • Du, T.R.1    Vega, J.A.2    Fonn, D.3    Simpson, T.4
  • 7
    • 3843067783 scopus 로고    scopus 로고
    • Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry
    • Gillis, A. and Zeyen, T. (2004) Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry. Bull. Soc. Belge. Ophtalmol., 292, 71-75.
    • (2004) Bull. Soc. Belge. Ophtalmol , vol.292 , pp. 71-75
    • Gillis, A.1    Zeyen, T.2
  • 8
    • 0037255230 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    • González-Méijome, J. M., Cervino, A., Yebra-Pimentel, E. and Parafita, M. A. (2003) Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry. J. Cataract. Refract. Surg. 29, 125-132.
    • (2003) J. Cataract. Refract. Surg , vol.29 , pp. 125-132
    • González-Méijome, J.M.1    Cervino, A.2    Yebra-Pimentel, E.3    Parafita, M.A.4
  • 9
    • 0343773370 scopus 로고    scopus 로고
    • Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures
    • Iskander, N. G., Anderson, P. E., Peters, N. T., Gimbel, H. V. and Ferensowicz, M. (2001) Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures. J. Cataract Refract. Surg. 27, 681-685.
    • (2001) J. Cataract Refract. Surg , vol.27 , pp. 681-685
    • Iskander, N.G.1    Anderson, P.E.2    Peters, N.T.3    Gimbel, H.V.4    Ferensowicz, M.5
  • 10
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • Lackner, B., Schmidinger, G., Pieh, S., Funovics, M. A. and Skorpik, C. (2005) Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom. Vis. Sci. 82, 892-899.
    • (2005) Optom. Vis. Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3    Funovics, M.A.4    Skorpik, C.5
  • 11
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability of corneal thickness measures
    • Marsich, M. W. and Bullimore, M. A. (2000) The repeatability of corneal thickness measures. Cornea 19, 792-795.
    • (2000) Cornea , vol.19 , pp. 792-795
    • Marsich, M.W.1    Bullimore, M.A.2
  • 12
    • 2942623857 scopus 로고    scopus 로고
    • Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods
    • McLaren, J. W., Nau, C. B., Erie, J. C. and Bourne, W. M. (2004) Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods. Am. J. Ophthalmol. 137, 1011-1020.
    • (2004) Am. J. Ophthalmol , vol.137 , pp. 1011-1020
    • McLaren, J.W.1    Nau, C.B.2    Erie, J.C.3    Bourne, W.M.4
  • 13
    • 0035737828 scopus 로고    scopus 로고
    • Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness
    • Modis, L., Jr, Langenbucher, A. and Seitz, B. (2001) Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness. Cornea 20, 711-714.
    • (2001) Cornea , vol.20 , pp. 711-714
    • Modis Jr, L.1    Langenbucher, A.2    Seitz, B.3
  • 16
    • 33847216449 scopus 로고    scopus 로고
    • Parafita, M. A., Yebra-Pimentel, E., Giraldez, M. J., Gonzalez, J., Gonzalez-Meijome, J. M. and Cerviño, A. (2002) Optical methods for corneal thickness measurement: a review. In: Recent Research Developments in Optics (ed. S. G. Pandalai), Research Signpost, Trivandrum, Kerala, pp. 35-51.
    • Parafita, M. A., Yebra-Pimentel, E., Giraldez, M. J., Gonzalez, J., Gonzalez-Meijome, J. M. and Cerviño, A. (2002) Optical methods for corneal thickness measurement: a review. In: Recent Research Developments in Optics (ed. S. G. Pandalai), Research Signpost, Trivandrum, Kerala, pp. 35-51.
  • 17
    • 0037986535 scopus 로고    scopus 로고
    • Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses
    • Perez, J. G., Meijome, J. M., Jalbert, I., Sweeney, D. F. and Erickson, P. (2003) Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses. Cornea 22, 304-307.
    • (2003) Cornea , vol.22 , pp. 304-307
    • Perez, J.G.1    Meijome, J.M.2    Jalbert, I.3    Sweeney, D.F.4    Erickson, P.5
  • 20
    • 0030732713 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    • Yaylali, V., Kaufman, S. C. and Thompson, H. W. (1997) Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry. J. Cataract Refract. Surg. 23, 1345-1350.
    • (1997) J. Cataract Refract. Surg , vol.23 , pp. 1345-1350
    • Yaylali, V.1    Kaufman, S.C.2    Thompson, H.W.3