-
1
-
-
0032470563
-
Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy
-
Abbasoglu, O. E., Bowman, R. W., Cavanagh, H. D. McCulley, J. P. (1998) Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology 105, 2193 2196.
-
(1998)
Ophthalmology
, vol.105
, pp. 2193-2196
-
-
Abbasoglu, O.E.1
Bowman, R.W.2
Cavanagh, H.D.3
McCulley, J.P.4
-
2
-
-
33746350421
-
Central and peripheral corneal thickness: Influence on the iop measurement by Tonopen
-
Amaral, W. O., Teixeira, R. M., Alencar, L. M., Cronemberger, S. Calixto, N. (2006) Central and peripheral corneal thickness: influence on the iop measurement by Tonopen. Arq Bras. Oftalmol. 69, 41 45.
-
(2006)
Arq Bras. Oftalmol.
, vol.69
, pp. 41-45
-
-
Amaral, W.O.1
Teixeira, R.M.2
Alencar, L.M.3
Cronemberger, S.4
Calixto, N.5
-
3
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland, J. M. Altman, D. G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1, 307 310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
4
-
-
0037562793
-
Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications
-
Boote, C., Dennis, S., Newton, R. H., Puri, H. Meek, K. M. (2003) Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications. Invest. Ophthalmol. Vis. Sci 44, 2941 2948.
-
(2003)
Invest. Ophthalmol. Vis. Sci
, vol.44
, pp. 2941-2948
-
-
Boote, C.1
Dennis, S.2
Newton, R.H.3
Puri, H.4
Meek, K.M.5
-
5
-
-
33646190149
-
Central corneal thickness and corneal hysteresis associated with glaucoma damage
-
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D. Quigley, H. A. (2006) Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am. J. Ophthalmol. 141, 868 875.
-
(2006)
Am. J. Ophthalmol.
, vol.141
, pp. 868-875
-
-
Congdon, N.G.1
Broman, A.T.2
Bandeen-Roche, K.3
Grover, D.4
Quigley, H.A.5
-
6
-
-
33645464184
-
Clinical evaluation of rebound tonometer
-
Davies, L. N., Bartlett, H., Mallen, E. A. Wolffsohn, J. S. (2006) Clinical evaluation of rebound tonometer. Acta Ophthalmol. Scand. 84, 206 209.
-
(2006)
Acta Ophthalmol. Scand.
, vol.84
, pp. 206-209
-
-
Davies, L.N.1
Bartlett, H.2
Mallen, E.A.3
Wolffsohn, J.S.4
-
7
-
-
28244452880
-
Comparison of the ICare(R) rebound tonometer with the Goldmann tonometer in a normal population
-
Fernandes, P., Diaz-Rey, J. A., Queiros, A., Gonzalez-Meijome, J. M. Jorge, J. (2005) Comparison of the ICare(R) rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol. Opt. 25, 436 440.
-
(2005)
Ophthalmic Physiol. Opt.
, vol.25
, pp. 436-440
-
-
Fernandes, P.1
Diaz-Rey, J.A.2
Queiros, A.3
Gonzalez-Meijome, J.M.4
Jorge, J.5
-
8
-
-
33644629030
-
Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
-
Garcia-Resua, C., Gonzalez-Meijome, J. M., Gilino, J. Yebra-Pimentel, E. (2006) Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom Vis. Sci 83, 102 107.
-
(2006)
Optom Vis. Sci
, vol.83
, pp. 102-107
-
-
Garcia-Resua, C.1
Gonzalez-Meijome, J.M.2
Gilino, J.3
Yebra-Pimentel, E.4
-
9
-
-
33845239951
-
Age differences in central and peripheral intraocular pressure using a rebound tonometer
-
Gonzalez-Meijome, J. M., Jorge, J., Queiros, A., Fernandes, P., Montes-Mico, R., Almeida, J. B. Parafita, M. A. (2006) Age differences in central and peripheral intraocular pressure using a rebound tonometer. Br. J. Ophthalmol. 90, 1495 1500.
-
(2006)
Br. J. Ophthalmol.
, vol.90
, pp. 1495-1500
-
-
Gonzalez-Meijome, J.M.1
Jorge, J.2
Queiros, A.3
Fernandes, P.4
Montes-Mico, R.5
Almeida, J.B.6
Parafita, M.A.7
-
10
-
-
33745667304
-
Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness
-
Iliev, M. E., Goldblum, D., Katsoulis, K., Amstutz, C. Frueh, B. (2006) Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness. Br. J. Ophthalmol 90, 833 835.
-
(2006)
Br. J. Ophthalmol
, vol.90
, pp. 833-835
-
-
Iliev, M.E.1
Goldblum, D.2
Katsoulis, K.3
Amstutz, C.4
Frueh, B.5
-
11
-
-
28244471011
-
Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*
-
van der Jagt, L. H. Jansonius, N. M. (2005) Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*. Ophthalmic Physiol. Opt. 25, 429 435.
-
(2005)
Ophthalmic Physiol. Opt.
, vol.25
, pp. 429-435
-
-
Van Der Jagt, L.H.1
Jansonius, N.M.2
-
12
-
-
0036832464
-
Clinical performance of the Reichert AT550: A new non-contact tonometer
-
Jorge, J., Diaz-Rey, J. A., Gonzalez-Meijome, J. M., Almeida, J. B. Parafita, M. A. (2002) Clinical performance of the Reichert AT550: a new non-contact tonometer. Ophthalmic Physiol. Opt. 22, 560 564.
-
(2002)
Ophthalmic Physiol. Opt.
, vol.22
, pp. 560-564
-
-
Jorge, J.1
Diaz-Rey, J.A.2
Gonzalez-Meijome, J.M.3
Almeida, J.B.4
Parafita, M.A.5
-
13
-
-
1542754969
-
Clinical performance of non-contact tonometry by Reichert AT550 in glaucomatous patients
-
Jorge, J., Gonzalez-Meijome, J. M., Diaz-Rey, J. A., Almeida, J. B., Ribeiro, P. Parafita, M. A. (2003) Clinical performance of non-contact tonometry by Reichert AT550 in glaucomatous patients. Ophthalmic Physiol. Opt. 23, 503 506.
-
(2003)
Ophthalmic Physiol. Opt.
, vol.23
, pp. 503-506
-
-
Jorge, J.1
Gonzalez-Meijome, J.M.2
Diaz-Rey, J.A.3
Almeida, J.B.4
Ribeiro, P.5
Parafita, M.A.6
-
14
-
-
0041360373
-
Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
-
Kaufmann, C., Bachmann, L. M. Thiel, M. A. (2003) Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest. Ophthalmol. Vis. Sci. 44, 3790 3794.
-
(2003)
Invest. Ophthalmol. Vis. Sci.
, vol.44
, pp. 3790-3794
-
-
Kaufmann, C.1
Bachmann, L.M.2
Thiel, M.A.3
-
15
-
-
4344659799
-
Comparison of dynamic contour tonometry with goldmann applanation tonometry
-
Kaufmann, C., Bachmann, L. M. Thiel, M. A. (2004) Comparison of dynamic contour tonometry with goldmann applanation tonometry. Invest. Ophthalmol. Vis. Sci. 45, 3118 3121.
-
(2004)
Invest. Ophthalmol. Vis. Sci.
, vol.45
, pp. 3118-3121
-
-
Kaufmann, C.1
Bachmann, L.M.2
Thiel, M.A.3
-
16
-
-
0034115306
-
A new induction-based impact method for measuring intraocular pressure
-
Kontiola, A. I. (2000) A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol. Scand. 78, 142 145.
-
(2000)
Acta Ophthalmol. Scand.
, vol.78
, pp. 142-145
-
-
Kontiola, A.I.1
-
17
-
-
1142299596
-
Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
-
Kontiola, A. Puska, P. (2004) Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch. Clin. Exp. Ophthalmol. 242, 3 7.
-
(2004)
Graefes Arch. Clin. Exp. Ophthalmol.
, vol.242
, pp. 3-7
-
-
Kontiola, A.1
Puska, P.2
-
18
-
-
0035704347
-
The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
-
Kontiola, A. I., Goldblum, D., Mittag, T. Danias, J. (2001) The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Exp. Eye Res. 73, 781 785.
-
(2001)
Exp. Eye Res.
, vol.73
, pp. 781-785
-
-
Kontiola, A.I.1
Goldblum, D.2
Mittag, T.3
Danias, J.4
-
19
-
-
13844317411
-
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
-
Luce, D. A. (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J. Cataract Refract. Surg. 31, 156 162.
-
(2005)
J. Cataract Refract. Surg.
, vol.31
, pp. 156-162
-
-
Luce, D.A.1
-
20
-
-
33644797317
-
Reproducibility and clinical evaluation of rebound tonometry
-
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Castillo, A. Garcia-Sanchez, J. (2005) Reproducibility and clinical evaluation of rebound tonometry. Invest. Ophthalmol. Vis. Sci. 46, 4578 4580.
-
(2005)
Invest. Ophthalmol. Vis. Sci.
, vol.46
, pp. 4578-4580
-
-
Martinez-De-La-Casa, J.M.1
Garcia-Feijoo, J.2
Castillo, A.3
Garcia-Sanchez, J.4
-
21
-
-
33751505840
-
Effect of Corneal Thickness on Dynamic Contour, Rebound, and Goldmann Tonometry
-
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Vico, E., Fernandez-Vidal, A., Benitez Del Castillo, J. M., Wasfi, M. Garcia-Sanchez, J. (2006a) Effect of Corneal Thickness on Dynamic Contour, Rebound, and Goldmann Tonometry. Ophthalmology 113, 2162.
-
(2006)
Ophthalmology
, vol.113
, pp. 2162
-
-
Martinez-De-La-Casa, J.M.1
Garcia-Feijoo, J.2
Vico, E.3
Fernandez-Vidal, A.4
Benitez Del Castillo, J.M.5
Wasfi, M.6
Garcia-Sanchez, J.7
-
22
-
-
33751505840
-
Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry
-
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Vico, E., Fernandez-Vidal, A., itez del Castillo, J. M., Wasfi, M. Garcia-Sanchez, J. (2006b) Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry. Ophthalmology 113, 2156 2162.
-
(2006)
Ophthalmology
, vol.113
, pp. 2156-2162
-
-
Martinez-De-La-Casa, J.M.1
Garcia-Feijoo, J.2
Vico, E.3
Fernandez-Vidal, A.4
Itez Del Castillo, J.M.5
Wasfi, M.6
Garcia-Sanchez, J.7
-
23
-
-
0032994224
-
Tono-Pen tonometer and corneal thickness
-
Mok, K. H., Wong, C. S. Lee, V. W. (1999) Tono-Pen tonometer and corneal thickness. Eye 13 (Pt 1 35 37.
-
(1999)
Eye
, vol.13
, Issue.1
, pp. 35-37
-
-
Mok, K.H.1
Wong, C.S.2
Lee, V.W.3
-
24
-
-
0035070611
-
Intraocular pressure after excimer laser myopic refractive surgery
-
Montes-Mico, R. Charman, W. N. (2001) Intraocular pressure after excimer laser myopic refractive surgery. Ophthalmic Physiol. Opt. 21, 228 235.
-
(2001)
Ophthalmic Physiol. Opt.
, vol.21
, pp. 228-235
-
-
Montes-Mico, R.1
Charman, W.N.2
-
25
-
-
33745481846
-
Non-contact tonometry synchronized with cardiac rhythm and its relationship with blood pressure
-
Queiros, A., Gonzalez-Meijome, J. M., Fernandes, P., Jorge, J., Almeida, J. B. Parafita, M. A. (2006) Non-contact tonometry synchronized with cardiac rhythm and its relationship with blood pressure. Ophthalmic Physiol. Opt. 26, 384 391.
-
(2006)
Ophthalmic Physiol. Opt.
, vol.26
, pp. 384-391
-
-
Queiros, A.1
Gonzalez-Meijome, J.M.2
Fernandes, P.3
Jorge, J.4
Almeida, J.B.5
Parafita, M.A.6
-
26
-
-
0033930294
-
Central and peripheral pressure measurements with the Goldmann tonometer and Tono-Pen after photorefractive keratectomy for myopia
-
Schipper, I., Senn, P., Oyo-Szerenyi, K. Peter, R. (2000) Central and peripheral pressure measurements with the Goldmann tonometer and Tono-Pen after photorefractive keratectomy for myopia. J. Cataract Refract. Surg. 26, 929 933.
-
(2000)
J. Cataract Refract. Surg.
, vol.26
, pp. 929-933
-
-
Schipper, I.1
Senn, P.2
Oyo-Szerenyi, K.3
Peter, R.4
-
27
-
-
0742286885
-
Correspondence of Tono-Pen intraocular pressure measurements performed at the central cornea and mid-peripheral cornea
-
Sullivan-Mee, M. Pham, F. (2004) Correspondence of Tono-Pen intraocular pressure measurements performed at the central cornea and mid-peripheral cornea. Optometry 75, 26 32.
-
(2004)
Optometry
, vol.75
, pp. 26-32
-
-
Sullivan-Mee, M.1
Pham, F.2
|