-
1
-
-
0037089606
-
Passivation of nitinol wire for vascular implants-a demonstration of the benefits
-
O'Brien B., Carroll W.M., and Kelly M.J. Passivation of nitinol wire for vascular implants-a demonstration of the benefits. Biomaterials 23 (2002) 1739-1748
-
(2002)
Biomaterials
, vol.23
, pp. 1739-1748
-
-
O'Brien, B.1
Carroll, W.M.2
Kelly, M.J.3
-
2
-
-
0027361059
-
Nitinol intravascular stent: results of preclinical evaluation
-
Cragg A.H., De Jong S.C., Barnhart W.H., Landas S.K., and Smith T.P. Nitinol intravascular stent: results of preclinical evaluation. Radiology 189 (1993) 775-778
-
(1993)
Radiology
, vol.189
, pp. 775-778
-
-
Cragg, A.H.1
De Jong, S.C.2
Barnhart, W.H.3
Landas, S.K.4
Smith, T.P.5
-
3
-
-
0345129973
-
Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents
-
Trépanier C., Leung T.K., Tabrizian M., Yahia LH., Bienvenu J.-G., Tanguay J.-F., Piron D.L., and Bilodeau L. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. J. Biomed. Mater. Res. Appl. Biomater. 48 (1999) 165-171
-
(1999)
J. Biomed. Mater. Res. Appl. Biomater.
, vol.48
, pp. 165-171
-
-
Trépanier, C.1
Leung, T.K.2
Tabrizian, M.3
Yahia, LH.4
Bienvenu, J.-G.5
Tanguay, J.-F.6
Piron, D.L.7
Bilodeau, L.8
-
4
-
-
0036013823
-
Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model
-
Thierry B., Merhi Y., Bilodeau L., Trépanier C., and Tabrizian M. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model. Biomaterials 23 (2002) 2997-3005
-
(2002)
Biomaterials
, vol.23
, pp. 2997-3005
-
-
Thierry, B.1
Merhi, Y.2
Bilodeau, L.3
Trépanier, C.4
Tabrizian, M.5
-
5
-
-
0034333624
-
Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide
-
Shih C.-C., Lin S.-J., Chung K.-H., Chen Y.-L., and Su Y.-Y. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide. J. Biomed. Mater. Res. 52 (2000) 323-332
-
(2000)
J. Biomed. Mater. Res.
, vol.52
, pp. 323-332
-
-
Shih, C.-C.1
Lin, S.-J.2
Chung, K.-H.3
Chen, Y.-L.4
Su, Y.-Y.5
-
6
-
-
34548479942
-
Effects of Ti/TiN multilayer on corrosion resistance of nickel-titanium orthodontic brackets in artificial saliva
-
Liu C., Chu P.K., Lin G., and Yang D. Effects of Ti/TiN multilayer on corrosion resistance of nickel-titanium orthodontic brackets in artificial saliva. Corros. Sci. 49 (2007) 3783-3796
-
(2007)
Corros. Sci.
, vol.49
, pp. 3783-3796
-
-
Liu, C.1
Chu, P.K.2
Lin, G.3
Yang, D.4
-
7
-
-
23744484024
-
Nickel ion release from orthodontic NiTi wires under simulation of realistic in-situ conditions
-
Arndt M., Brück A., Scully T., Jäger A., and Bourauel C. Nickel ion release from orthodontic NiTi wires under simulation of realistic in-situ conditions. J. Mater. Sci. 40 (2005) 3659-3667
-
(2005)
J. Mater. Sci.
, vol.40
, pp. 3659-3667
-
-
Arndt, M.1
Brück, A.2
Scully, T.3
Jäger, A.4
Bourauel, C.5
-
8
-
-
50549087358
-
Effects of cold drawing and annealing on mechanical properties and microstructure of Co-Cr-Mo-Ni-Fe Alloys for surgical implants
-
Okazaki Y. Effects of cold drawing and annealing on mechanical properties and microstructure of Co-Cr-Mo-Ni-Fe Alloys for surgical implants. Mater. Trans. 49 (2008) 1656-1660
-
(2008)
Mater. Trans.
, vol.49
, pp. 1656-1660
-
-
Okazaki, Y.1
-
9
-
-
0032923862
-
Metal release and excretion from cementless titanium alloy total knee replacements
-
Jacobs J.J., Silverton C., Hallab N.J., Skipor A.K., Patterson L., Black J., and Galante J.O. Metal release and excretion from cementless titanium alloy total knee replacements. Clin. Orthop. Relat. Res. 358 (1999) 173-180
-
(1999)
Clin. Orthop. Relat. Res.
, vol.358
, pp. 173-180
-
-
Jacobs, J.J.1
Silverton, C.2
Hallab, N.J.3
Skipor, A.K.4
Patterson, L.5
Black, J.6
Galante, J.O.7
-
10
-
-
34548137271
-
Metal ion levels in patients with stainless steel spinal instrumentation
-
McPhee I.B., and Swanson C.E. Metal ion levels in patients with stainless steel spinal instrumentation. Spine 32 (2007) 1963-1968
-
(2007)
Spine
, vol.32
, pp. 1963-1968
-
-
McPhee, I.B.1
Swanson, C.E.2
-
11
-
-
0035108321
-
Metal sensitivity in patients with orthopaedic implants
-
Hallab N., Merritt K., and Jacobs J.J. Metal sensitivity in patients with orthopaedic implants. J. Bone Joint Surg. Am. 83A (2001) 428-436
-
(2001)
J. Bone Joint Surg. Am.
, vol.83 A
, pp. 428-436
-
-
Hallab, N.1
Merritt, K.2
Jacobs, J.J.3
-
12
-
-
0031727764
-
Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
-
Jacobs J.J., Skipor A.K., Patterson L.M., Hallab N.J., Paprosky W.G., Black J., and Galante J.O. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J. Bone Joint Surg. Am. 80A (1998) 1447-1458
-
(1998)
J. Bone Joint Surg. Am.
, vol.80 A
, pp. 1447-1458
-
-
Jacobs, J.J.1
Skipor, A.K.2
Patterson, L.M.3
Hallab, N.J.4
Paprosky, W.G.5
Black, J.6
Galante, J.O.7
-
13
-
-
0019128573
-
Metal ion release after total hip replacement
-
Dobbs H.S., and Minski M.J. Metal ion release after total hip replacement. Biomaterials 1 (1980) 193-198
-
(1980)
Biomaterials
, vol.1
, pp. 193-198
-
-
Dobbs, H.S.1
Minski, M.J.2
-
14
-
-
0031573493
-
Effects of metal ions on white blood cells of patients with failed total joint arthroplasties
-
Savarino L., Granchi D., Ciapetti G., Stea S., Donati M.E., Zinghi G., Fontanesi G., Rotini R., and Montanaro L. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties. J. Biomed. Mater. Res. 47 (1999) 543-550
-
(1999)
J. Biomed. Mater. Res.
, vol.47
, pp. 543-550
-
-
Savarino, L.1
Granchi, D.2
Ciapetti, G.3
Stea, S.4
Donati, M.E.5
Zinghi, G.6
Fontanesi, G.7
Rotini, R.8
Montanaro, L.9
-
15
-
-
0037052806
-
Urinary 8-hydroxydeoxyguanosine and sister chromatid exchanges in patients with total hip replacements
-
Pilger A., Schaffer A., Rüdiger H.W., and Osterode W. Urinary 8-hydroxydeoxyguanosine and sister chromatid exchanges in patients with total hip replacements. J. Toxicol. Environ. Health Part A 65 (2002) 655-664
-
(2002)
J. Toxicol. Environ. Health Part A
, vol.65
, pp. 655-664
-
-
Pilger, A.1
Schaffer, A.2
Rüdiger, H.W.3
Osterode, W.4
-
16
-
-
33644805262
-
The rationale for metal-on-metal total hip arthroplasty
-
Cuckler J.M. The rationale for metal-on-metal total hip arthroplasty. Clin. Orthop. Relat. Res. 441 (2005) 132-136
-
(2005)
Clin. Orthop. Relat. Res.
, vol.441
, pp. 132-136
-
-
Cuckler, J.M.1
-
17
-
-
42449094638
-
Does ion release differ between hip resurfacing and metal-on-metal THA?
-
Moroni A., Savarino L., Cadossi M., Baldini N., and Giannini S. Does ion release differ between hip resurfacing and metal-on-metal THA?. Clin Orthop Relat Res 466 (2008) 700-707
-
(2008)
Clin Orthop Relat Res
, vol.466
, pp. 700-707
-
-
Moroni, A.1
Savarino, L.2
Cadossi, M.3
Baldini, N.4
Giannini, S.5
-
18
-
-
0036380582
-
Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings
-
Savarino L., Granchi D., Ciapetti G., Cenni E., Pantoli A.N., Rotini R., Veronesi C.A., Baldini N., and Giunti A. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J. Biomed. Mater. Res. 63 (2002) 467-474
-
(2002)
J. Biomed. Mater. Res.
, vol.63
, pp. 467-474
-
-
Savarino, L.1
Granchi, D.2
Ciapetti, G.3
Cenni, E.4
Pantoli, A.N.5
Rotini, R.6
Veronesi, C.A.7
Baldini, N.8
Giunti, A.9
-
19
-
-
34249789255
-
Chromium and cobalt ion release following the durom high carbon content, forged metal-on-metal surface replacement of the hip
-
Vendittoli P.-A., Mottard S., Roy A.G., Dupont C., and Lavigne M. Chromium and cobalt ion release following the durom high carbon content, forged metal-on-metal surface replacement of the hip. J. Bone Joint Surg. Br. 89B (2007) 441-448
-
(2007)
J. Bone Joint Surg. Br.
, vol.89 B
, pp. 441-448
-
-
Vendittoli, P.-A.1
Mottard, S.2
Roy, A.G.3
Dupont, C.4
Lavigne, M.5
-
20
-
-
0030905094
-
Elevated serum cobalt with metal-on-metal articulating surfaces
-
Brodner W., Bitzan P., Meisinger V., Kaider A., Gottsauner-Wolf F., and Kotz R. Elevated serum cobalt with metal-on-metal articulating surfaces. J. Bone Joint Surg. Br. 79B (1997) 316-321
-
(1997)
J. Bone Joint Surg. Br.
, vol.79 B
, pp. 316-321
-
-
Brodner, W.1
Bitzan, P.2
Meisinger, V.3
Kaider, A.4
Gottsauner-Wolf, F.5
Kotz, R.6
-
21
-
-
14844286982
-
Metal-on-metal total hip replacement - what does the literature say?
-
Dumbleton J.H., and Manley M.T. Metal-on-metal total hip replacement - what does the literature say?. J. Arthrop. 20 (2005) 174-188
-
(2005)
J. Arthrop.
, vol.20
, pp. 174-188
-
-
Dumbleton, J.H.1
Manley, M.T.2
-
22
-
-
0347505008
-
Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation
-
Massé A., Bosetti M., Buratti C., Visentin O., Bergadano D., and Cannas M. Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation. J. Biomed. Mater. Res. Part B Appl. Biomater. 67B (2003) 750-757
-
(2003)
J. Biomed. Mater. Res. Part B Appl. Biomater.
, vol.67 B
, pp. 750-757
-
-
Massé, A.1
Bosetti, M.2
Buratti, C.3
Visentin, O.4
Bergadano, D.5
Cannas, M.6
-
23
-
-
0344306477
-
Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results
-
Savarino L., Granchi D., Ciapetti G., Cenni E., Greco M., Rotini R., Veronesi C.A., Baldini N., and Giunti A. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J. Biomed. Mater. Res. Part A 66A (2003) 450-456
-
(2003)
J. Biomed. Mater. Res. Part A
, vol.66 A
, pp. 450-456
-
-
Savarino, L.1
Granchi, D.2
Ciapetti, G.3
Cenni, E.4
Greco, M.5
Rotini, R.6
Veronesi, C.A.7
Baldini, N.8
Giunti, A.9
-
24
-
-
0033308094
-
Serum protein carriers of chromium in patients with cobalt-base alloy total joint replacement components
-
Disegi J.A., Kennedy R.L., and Pilliar R. (Eds), American Society For Testing And Materials Special Technical Publication (ASTM STP1365)
-
Hallab N.J., Jacobs J.J., Skipor A., Black J., Mikecz K., and Galante J.O. Serum protein carriers of chromium in patients with cobalt-base alloy total joint replacement components. In: Disegi J.A., Kennedy R.L., and Pilliar R. (Eds). Cobalt-Base Alloys for Biomedical Applications (1999), American Society For Testing And Materials Special Technical Publication (ASTM STP1365) 210-219
-
(1999)
Cobalt-Base Alloys for Biomedical Applications
, pp. 210-219
-
-
Hallab, N.J.1
Jacobs, J.J.2
Skipor, A.3
Black, J.4
Mikecz, K.5
Galante, J.O.6
-
25
-
-
33646234247
-
Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement
-
Savarino L., Greco M., Cenni E., Cavasinni L., Rotini R., Baldini N., and Giunti A. Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. J. Bone Joint Surg. Br. 88B (2006) 472-476
-
(2006)
J. Bone Joint Surg. Br.
, vol.88 B
, pp. 472-476
-
-
Savarino, L.1
Greco, M.2
Cenni, E.3
Cavasinni, L.4
Rotini, R.5
Baldini, N.6
Giunti, A.7
-
26
-
-
33750870614
-
Current in vivo wear of metal-on-metal bearing assessed by exercise-related rise in plasma cobalt level
-
Khań M., Takahashi T., Kuiper J.H., Sieniawska C.E., Takagi K., and Richardson J.B. Current in vivo wear of metal-on-metal bearing assessed by exercise-related rise in plasma cobalt level. J. Orthop. Res. 24 (2006) 2029-2035
-
(2006)
J. Orthop. Res.
, vol.24
, pp. 2029-2035
-
-
Khań, M.1
Takahashi, T.2
Kuiper, J.H.3
Sieniawska, C.E.4
Takagi, K.5
Richardson, J.B.6
-
27
-
-
33645234539
-
The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty
-
Cobb A.G., and Schmalzreid T.P. The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty. Proc. Inst. Mech. Eng. H. 220 (2006) 385-398
-
(2006)
Proc. Inst. Mech. Eng. H.
, vol.220
, pp. 385-398
-
-
Cobb, A.G.1
Schmalzreid, T.P.2
-
28
-
-
9444243222
-
Metal ion release from metal implants
-
Hanawa T. Metal ion release from metal implants. Mater. Sci. Eng. C. 24 (2004) 745-752
-
(2004)
Mater. Sci. Eng. C.
, vol.24
, pp. 745-752
-
-
Hanawa, T.1
-
29
-
-
0028500384
-
Surface modification of titanium alloy implants
-
Browne M., and Gregson P.J. Surface modification of titanium alloy implants. Biomaterials 15 (1994) 894-898
-
(1994)
Biomaterials
, vol.15
, pp. 894-898
-
-
Browne, M.1
Gregson, P.J.2
-
30
-
-
0030684995
-
Corrosion resistance of implant alloys in Pseudo physiological solution and role of alloying elements in passive films
-
Okazaki Y., Tateishi T., and Ito Y. Corrosion resistance of implant alloys in Pseudo physiological solution and role of alloying elements in passive films. Mater. Trans. JIM 38 (1997) 78-84
-
(1997)
Mater. Trans. JIM
, vol.38
, pp. 78-84
-
-
Okazaki, Y.1
Tateishi, T.2
Ito, Y.3
-
31
-
-
33751326121
-
Metal release from various grades of stainless steel exposed to synthetic body fluids
-
Herting G., Odnevall Wallinder I., and Leygraf C. Metal release from various grades of stainless steel exposed to synthetic body fluids. Corros. Sci. 49 (2007) 103-111
-
(2007)
Corros. Sci.
, vol.49
, pp. 103-111
-
-
Herting, G.1
Odnevall Wallinder, I.2
Leygraf, C.3
-
32
-
-
33746266425
-
Factors that influence the release of metals from stainless steels exposed to physiological media
-
Herting G., Odnevall Wallinder I., and Leygraf C. Factors that influence the release of metals from stainless steels exposed to physiological media. Corros. Sci. 48 (2006) 2120-2132
-
(2006)
Corros. Sci.
, vol.48
, pp. 2120-2132
-
-
Herting, G.1
Odnevall Wallinder, I.2
Leygraf, C.3
-
33
-
-
39749135591
-
Corrosion-induced release of chromium and iron from ferritic stainless steel grade AISI 430 in stimulated food contact
-
Herting G., Odnevall Wallinder I., and Leygraf C. Corrosion-induced release of chromium and iron from ferritic stainless steel grade AISI 430 in stimulated food contact. J. Food Eng. 87 (2008) 291-300
-
(2008)
J. Food Eng.
, vol.87
, pp. 291-300
-
-
Herting, G.1
Odnevall Wallinder, I.2
Leygraf, C.3
-
34
-
-
1342264209
-
Passive and transpassive behaviour of CoCrMo in simulated biological solutions
-
Hodgson A.W.E., Kurz S., Virtanen S., Fervel V., Olsson C.-O.A., and Mischler S. Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochimic. Acta 49 (2004) 2167-2178
-
(2004)
Electrochimic. Acta
, vol.49
, pp. 2167-2178
-
-
Hodgson, A.W.E.1
Kurz, S.2
Virtanen, S.3
Fervel, V.4
Olsson, C.-O.A.5
Mischler, S.6
-
35
-
-
20344385048
-
Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants
-
Lewis A.C., Kilburn M.R., Papageorgiou I., Allen G.C., and Case C.P. Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants. J. Biomed. Mater. Res. 73A (2005) 456-467
-
(2005)
J. Biomed. Mater. Res.
, vol.73 A
, pp. 456-467
-
-
Lewis, A.C.1
Kilburn, M.R.2
Papageorgiou, I.3
Allen, G.C.4
Case, C.P.5
-
36
-
-
0032052625
-
Electrochemical and surface characterization of a nickel-titanium alloy
-
Wever D.J., Veldhuizen A.G., de Vries J., Busscher H.J., Uges D.R.A., and van Horn J.R. Electrochemical and surface characterization of a nickel-titanium alloy. Biomaterials 19 (1998) 761-769
-
(1998)
Biomaterials
, vol.19
, pp. 761-769
-
-
Wever, D.J.1
Veldhuizen, A.G.2
de Vries, J.3
Busscher, H.J.4
Uges, D.R.A.5
van Horn, J.R.6
-
37
-
-
0030340747
-
On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
-
Shabalovskaya S.A. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. Bio-Med. Mater. Eng. 6 (1996) 267-289
-
(1996)
Bio-Med. Mater. Eng.
, vol.6
, pp. 267-289
-
-
Shabalovskaya, S.A.1
-
38
-
-
0036179018
-
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
-
Shabalovskaya S.A. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Bio-Med. Mater. Eng. 12 (2002) 69-109
-
(2002)
Bio-Med. Mater. Eng.
, vol.12
, pp. 69-109
-
-
Shabalovskaya, S.A.1
-
39
-
-
0034666762
-
Effect of surface treatment and sterilization processes on the corrosion behaviour of NiTi shape memory alloy
-
Thierry B., Tabrizian M., Trepanier C., Savadogo O., and Yahia LH. Effect of surface treatment and sterilization processes on the corrosion behaviour of NiTi shape memory alloy. J. Biomed. Mater. Res. 51 (2000) 685-693
-
(2000)
J. Biomed. Mater. Res.
, vol.51
, pp. 685-693
-
-
Thierry, B.1
Tabrizian, M.2
Trepanier, C.3
Savadogo, O.4
Yahia, LH.5
-
40
-
-
0032403412
-
Effect of modification of oxide layer on NiTi stent corrosion resistance
-
Trépanier C., Tabrizian M., Yahia L., Bilodeau L., and Piron D.L. Effect of modification of oxide layer on NiTi stent corrosion resistance. J. Biomed. Mater. Res. Appl. Biomater. 43 (1998) 433-440
-
(1998)
J. Biomed. Mater. Res. Appl. Biomater.
, vol.43
, pp. 433-440
-
-
Trépanier, C.1
Tabrizian, M.2
Yahia, L.3
Bilodeau, L.4
Piron, D.L.5
-
41
-
-
33748999537
-
Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release
-
Clarke B., Carroll W., Rochev Y., Hynes M., Bradley D., and Plumley D. Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release. J. Biomed. Mater. Res. 79A (2006) 61-70
-
(2006)
J. Biomed. Mater. Res.
, vol.79 A
, pp. 61-70
-
-
Clarke, B.1
Carroll, W.2
Rochev, Y.3
Hynes, M.4
Bradley, D.5
Plumley, D.6
-
42
-
-
34250654178
-
Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release
-
Summer B., Fink U., Zeller R., Rueff F., Maier S., Roider G., and Thomas P. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release. Contact Dermatitis 57 (2007) 35-39
-
(2007)
Contact Dermatitis
, vol.57
, pp. 35-39
-
-
Summer, B.1
Fink, U.2
Zeller, R.3
Rueff, F.4
Maier, S.5
Roider, G.6
Thomas, P.7
-
43
-
-
0026324454
-
Implications of metallic corrosion in total knee arthroplasty
-
Wapner K.L. Implications of metallic corrosion in total knee arthroplasty. Clin. Orthop. Relat. Res. 271 (1991) 12-20
-
(1991)
Clin. Orthop. Relat. Res.
, vol.271
, pp. 12-20
-
-
Wapner, K.L.1
-
44
-
-
56649121085
-
-
ISO 5832-1, Implants for Surgery - Metallic materials - Part 1: Wrought Stainless Steel, 2007.
-
ISO 5832-1, Implants for Surgery - Metallic materials - Part 1: Wrought Stainless Steel, 2007.
-
-
-
-
45
-
-
56649105717
-
-
ISO 5832-9, Implants for Surgery - Metallic Materials - Part 9: Wrought High Nitrogen Stainless Steel, 2007.
-
ISO 5832-9, Implants for Surgery - Metallic Materials - Part 9: Wrought High Nitrogen Stainless Steel, 2007.
-
-
-
-
46
-
-
48249090084
-
Effects of solution treatment and cold rolling on microstructure and mechanical properties of stainless steel for surgical implants
-
Okazaki Y. Effects of solution treatment and cold rolling on microstructure and mechanical properties of stainless steel for surgical implants. Mater. Trans. 49 (2008) 1423-1427
-
(2008)
Mater. Trans.
, vol.49
, pp. 1423-1427
-
-
Okazaki, Y.1
-
47
-
-
44349148752
-
Effects of heat treatment and hot forging on microstructure and mechanical properties of Co-Cr-Mo alloy for surgical implants
-
Okazaki Y. Effects of heat treatment and hot forging on microstructure and mechanical properties of Co-Cr-Mo alloy for surgical implants. Mater. Trans. 49 (2008) 817-823
-
(2008)
Mater. Trans.
, vol.49
, pp. 817-823
-
-
Okazaki, Y.1
-
48
-
-
56649122485
-
-
JIS T 0304, Testing Method for Metal Release from Metallic Biomaterials, 2002.
-
JIS T 0304, Testing Method for Metal Release from Metallic Biomaterials, 2002.
-
-
-
-
49
-
-
56649111814
-
-
JIS T 0302, Testing Method for Corrosion Resistance of Metallic Biomaterials by Anodic Polarization Measurement, 2000.
-
JIS T 0302, Testing Method for Corrosion Resistance of Metallic Biomaterials by Anodic Polarization Measurement, 2000.
-
-
-
-
50
-
-
56649125214
-
-
ISO 16428, Implants for Surgery - Test Solutions and Environmental Conditions for Static and Dynamic Corrosion Tests on Implantable Materials and Medical Devices, 2005.
-
ISO 16428, Implants for Surgery - Test Solutions and Environmental Conditions for Static and Dynamic Corrosion Tests on Implantable Materials and Medical Devices, 2005.
-
-
-
-
51
-
-
56649121084
-
-
ISO 16429, Implants for Surgery - Measurements of Open-Circuit Potential to Assess Corrosion Behaviour of Metallic Implantable Materials and Medical Devices Over Extended Time Periods, 2004.
-
ISO 16429, Implants for Surgery - Measurements of Open-Circuit Potential to Assess Corrosion Behaviour of Metallic Implantable Materials and Medical Devices Over Extended Time Periods, 2004.
-
-
-
-
52
-
-
56649091804
-
-
Official J European Union L 301, 27. 9. 2004, p. 51, Commission Directive 2004/96/EC, Amending Council Directive 76/769/EEC as Regards Restrictions on the Marketing and Use of Nickel for Piercing Post Assemblies for the Purpose of Adapting its Annex I to Technical Progress.
-
Official J European Union L 301, 27. 9. 2004, p. 51, Commission Directive 2004/96/EC, Amending Council Directive 76/769/EEC as Regards Restrictions on the Marketing and Use of Nickel for Piercing Post Assemblies for the Purpose of Adapting its Annex I to Technical Progress.
-
-
-
-
53
-
-
0038722957
-
-
Winters G.L., and Nutt M.J. (Eds), ASTM International (ASTM STP 1438), West Conshohocken
-
Haraldsson C., and Cowen S. Characterization of Sandvik Bioline high-N-A comparison of standard grades F1314 and F1586 stainless steels for medical and surgical applications. In: Winters G.L., and Nutt M.J. (Eds) (2003), ASTM International (ASTM STP 1438), West Conshohocken 3-12
-
(2003)
Characterization of Sandvik Bioline high-N-A comparison of standard grades F1314 and F1586 stainless steels for medical and surgical applications
, pp. 3-12
-
-
Haraldsson, C.1
Cowen, S.2
-
54
-
-
0027942355
-
Effect of chemical composition of man-made vitreous fibers on the rate of dissolution in vitro at different pHs
-
Christensen V.R., Lund Jensen S., Guldberg M., and Kamstrup O. Effect of chemical composition of man-made vitreous fibers on the rate of dissolution in vitro at different pHs. Environ. Health Persp. 102 (1994) 83-86
-
(1994)
Environ. Health Persp.
, vol.102
, pp. 83-86
-
-
Christensen, V.R.1
Lund Jensen, S.2
Guldberg, M.3
Kamstrup, O.4
-
55
-
-
0023567506
-
Metal release from heat-treated orthodontic archwires
-
Gjerdet N.R., and Hero H. Metal release from heat-treated orthodontic archwires. Acta Odontol. Scand. 45 (1987) 409-414
-
(1987)
Acta Odontol. Scand.
, vol.45
, pp. 409-414
-
-
Gjerdet, N.R.1
Hero, H.2
-
56
-
-
56649118009
-
-
ASTM F2063, Standard Specification for Wrought Nickel-Titanium Shape Memory Alloys for Medical Devices and Surgical Implants.
-
ASTM F2063, Standard Specification for Wrought Nickel-Titanium Shape Memory Alloys for Medical Devices and Surgical Implants.
-
-
-
-
57
-
-
0031214566
-
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
-
Wever D.J., Veldhuizen A.G., Sanders M.M., Schakenraad J.M., and van Horn J.R. Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. Biomaterials 18 (1997) 1115-1120
-
(1997)
Biomaterials
, vol.18
, pp. 1115-1120
-
-
Wever, D.J.1
Veldhuizen, A.G.2
Sanders, M.M.3
Schakenraad, J.M.4
van Horn, J.R.5
-
58
-
-
0033033120
-
Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation
-
Assad M., Lemieux N., Rivard C.H., and Yahia LH. Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation. Bio-Med. Mater. Eng. 9 (1999) 1-12
-
(1999)
Bio-Med. Mater. Eng.
, vol.9
, pp. 1-12
-
-
Assad, M.1
Lemieux, N.2
Rivard, C.H.3
Yahia, LH.4
-
59
-
-
2642582913
-
Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
-
Ryhänen J., Niemi E., Serlo W., Niemelä E., Sandvik P., Pernu H., and Salo T. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J. Biomed. Mater. Res. 35 (1997) 451-457
-
(1997)
J. Biomed. Mater. Res.
, vol.35
, pp. 451-457
-
-
Ryhänen, J.1
Niemi, E.2
Serlo, W.3
Niemelä, E.4
Sandvik, P.5
Pernu, H.6
Salo, T.7
-
61
-
-
0036013926
-
On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility
-
Es-Souni M., Es-Souni M., and Fischer-Brandies H. On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility. Biomaterials 23 (2002) 2887-2894
-
(2002)
Biomaterials
, vol.23
, pp. 2887-2894
-
-
Es-Souni, M.1
Es-Souni, M.2
Fischer-Brandies, H.3
-
62
-
-
0032808131
-
Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations
-
Jia W., Beatty M.W., Reinhardt R.A., Petro T.M., Cohen D.M., Maze C.R., Strom E.A., and Hoffman M. Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations. J. Biomed. Mater. Res. Appl. Biomater. 48 (1999) 488-495
-
(1999)
J. Biomed. Mater. Res. Appl. Biomater.
, vol.48
, pp. 488-495
-
-
Jia, W.1
Beatty, M.W.2
Reinhardt, R.A.3
Petro, T.M.4
Cohen, D.M.5
Maze, C.R.6
Strom, E.A.7
Hoffman, M.8
|