메뉴 건너뛰기




Volumn 32, Issue 18, 2007, Pages 1963-1968

Metal ion levels in patients with stainless steel spinal instrumentation

Author keywords

Chromium; Corrosion; Nickel; Spinal implant; Stainless steel

Indexed keywords

CHROMIUM; CREATININE; METAL ION; NICKEL; STAINLESS STEEL;

EID: 34548137271     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318133aa0d     Document Type: Article
Times cited : (34)

References (65)
  • 1
    • 0014575655 scopus 로고
    • Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint: With special reference to the bacterial content of the air of the operating room
    • Charnley J, Eftekhar N. Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint: with special reference to the bacterial content of the air of the operating room. Br J Surg 1969;56:641-9.
    • (1969) Br J Surg , vol.56 , pp. 641-649
    • Charnley, J.1    Eftekhar, N.2
  • 2
    • 0017777772 scopus 로고
    • Late infection after hip replacement
    • Bayston R, Zachary RB. Late infection after hip replacement. Br Med J 1977;2:770-1.
    • (1977) Br Med J , vol.2 , pp. 770-771
    • Bayston, R.1    Zachary, R.B.2
  • 3
    • 0017386404 scopus 로고
    • Late infection after total hip replacement
    • Downes EM. Late infection after total hip replacement. J Bone Joint Surg Br 1977;59:42-4.
    • (1977) J Bone Joint Surg Br , vol.59 , pp. 42-44
    • Downes, E.M.1
  • 4
    • 0015545829 scopus 로고
    • Massive articular osteolysis in rheumatoid arthritis, treated by total hip replacement: Case report and review of literature
    • Kennedy WR, Johnston AD, Becker A. Massive articular osteolysis in rheumatoid arthritis, treated by total hip replacement: case report and review of literature. Clin Orthop 1973:161-73.
    • (1973) Clin Orthop , pp. 161-173
    • Kennedy, W.R.1    Johnston, A.D.2    Becker, A.3
  • 6
    • 0017129995 scopus 로고
    • Extensive localized bone resorption in the femur following total hip replacement
    • Harris WH, Schiller AL, Scholler JM, et al. Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg Am 1976;58:612-8.
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 612-618
    • Harris, W.H.1    Schiller, A.L.2    Scholler, J.M.3
  • 7
    • 0014849042 scopus 로고
    • Loosening of total hip replacements with cement fixation: Clinical findings and laboratory studies
    • Wilson JN, Scales JT. Loosening of total hip replacements with cement fixation: clinical findings and laboratory studies. Clin Orthop 1970;72:145-60.
    • (1970) Clin Orthop , vol.72 , pp. 145-160
    • Wilson, J.N.1    Scales, J.T.2
  • 8
    • 0015429842 scopus 로고
    • Loosening of the cemented acetabular cup in total hip replacement
    • Andersson GB, Freeman MA, Swanson SA. Loosening of the cemented acetabular cup in total hip replacement. J Bone Joint Surg Br 1972;54:590-9.
    • (1972) J Bone Joint Surg Br , vol.54 , pp. 590-599
    • Andersson, G.B.1    Freeman, M.A.2    Swanson, S.A.3
  • 10
    • 0016968013 scopus 로고
    • The pathology of the joint tissues and its clinical relevance in prosthesis failure
    • Mirra JM, Amstutz HC, Matos M, et al. The pathology of the joint tissues and its clinical relevance in prosthesis failure. Clin Orthop 1976;117:221-40.
    • (1976) Clin Orthop , vol.117 , pp. 221-240
    • Mirra, J.M.1    Amstutz, H.C.2    Matos, M.3
  • 12
    • 0015932520 scopus 로고
    • Acrylic bone cement hazard
    • Coventry MB. Acrylic bone cement hazard. JAMA 1973;223:442.
    • (1973) JAMA , vol.223 , pp. 442
    • Coventry, M.B.1
  • 13
    • 0016251286 scopus 로고
    • Reaction of bone to methacrylate after hip arthroplasty: A long-term gross, light microscopic, and scanning electron microscopic study
    • Willert HG, Ludwig J, Semlitsch M. Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study. J Bone Joint Surg Am 1974;56:1368-82.
    • (1974) J Bone Joint Surg Am , vol.56 , pp. 1368-1382
    • Willert, H.G.1    Ludwig, J.2    Semlitsch, M.3
  • 14
    • 0029817370 scopus 로고    scopus 로고
    • Cobalt and chromium concentrations in patients with metal on metal total hip replacements
    • Jacobs JJ, Skipor AK, Doorn PF, et al. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin Orthop 1996;329(suppl):256-63.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 256-263
    • Jacobs, J.J.1    Skipor, A.K.2    Doorn, P.F.3
  • 15
    • 0346037224 scopus 로고    scopus 로고
    • Serum and urine metal levels in patients with metal-on-metal surface arthroplasty
    • Skipor AK, Campbell PA, Patterson LM, et al. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med 2002;13:1227-34.
    • (2002) J Mater Sci Mater Med , vol.13 , pp. 1227-1234
    • Skipor, A.K.1    Campbell, P.A.2    Patterson, L.M.3
  • 16
    • 0036380582 scopus 로고    scopus 로고
    • Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with metal-on-polyethylene bearings
    • Savarino L, Granchi D, Ciapetti G, et al. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 2002;63:467-74.
    • (2002) J Biomed Mater Res , vol.63 , pp. 467-474
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3
  • 17
    • 0242490794 scopus 로고    scopus 로고
    • Serum cobalt levels after metal-on-metal total hip arthroplasty
    • Brodner W, Bitzan P, Meisinger V, et al. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am 2003;85:2168-73.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 2168-2173
    • Brodner, W.1    Bitzan, P.2    Meisinger, V.3
  • 18
    • 0344306477 scopus 로고    scopus 로고
    • Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: A comparison between short- and medium term results
    • Savarino L, Granchi D, Ciapetti G, et al. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium term results. J Biomed Mater Res 2003;66:450-6.
    • (2003) J Biomed Mater Res , vol.66 , pp. 450-456
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3
  • 19
    • 4444367202 scopus 로고    scopus 로고
    • Chronological changes of serum chromium levels after modern metal-on-metal total hip arthroplasty
    • Maezawa K, Nozawa M, Matsuda K, et al. Chronological changes of serum chromium levels after modern metal-on-metal total hip arthroplasty. Acta Orthop Scand 2004;75:422-6.
    • (2004) Acta Orthop Scand , vol.75 , pp. 422-426
    • Maezawa, K.1    Nozawa, M.2    Matsuda, K.3
  • 20
    • 18244384199 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements
    • Milosev I, Pisot V, Campbell P. Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements. J Orthop Res 2005;23:526-35.
    • (2005) J Orthop Res , vol.23 , pp. 526-535
    • Milosev, I.1    Pisot, V.2    Campbell, P.3
  • 21
    • 0028845164 scopus 로고
    • Local and distant products from modularity
    • Jacobs JJ, Urban RM, Gilbert JL, et al. Local and distant products from modularity. Clin Orthop 1995;319:94-105.
    • (1995) Clin Orthop , vol.319 , pp. 94-105
    • Jacobs, J.J.1    Urban, R.M.2    Gilbert, J.L.3
  • 22
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty: A prospective, controlled, longitudinal study
    • Jacobs JJ, Skipor AK, Patterson LM, et al. Metal release in patients who have had a primary total hip arthroplasty: a prospective, controlled, longitudinal study. J Bone Joint Surg Am 1998;80:1447-58.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, L.M.3
  • 23
    • 0036787573 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in a complex modular total hip arthroplasty system
    • Harding I, Bonomo A, Crawford R, et al. Serum levels of cobalt and chromium in a complex modular total hip arthroplasty system. J Arthroplasty 2002;17:893-5.
    • (2002) J Arthroplasty , vol.17 , pp. 893-895
    • Harding, I.1    Bonomo, A.2    Crawford, R.3
  • 24
    • 0041527157 scopus 로고    scopus 로고
    • Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty
    • Clarke MT, Lee PT, Arora A, et al. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br 2003;85:913-7.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 913-917
    • Clarke, M.T.1    Lee, P.T.2    Arora, A.3
  • 25
    • 9644279533 scopus 로고    scopus 로고
    • Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty
    • Brodner W, Grubl A, Jankovsky R, et al. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 2004;19(suppl 3):66-70.
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL. 3 , pp. 66-70
    • Brodner, W.1    Grubl, A.2    Jankovsky, R.3
  • 26
    • 0032943726 scopus 로고    scopus 로고
    • An assessment of the histological criteria used to diagnose infection in hip revision arthroplasty tissues
    • Pandey R, Drakoulakis E, Athanasou NA. An assessment of the histological criteria used to diagnose infection in hip revision arthroplasty tissues. J Clin Pathol 1999;52:118-23.
    • (1999) J Clin Pathol , vol.52 , pp. 118-123
    • Pandey, R.1    Drakoulakis, E.2    Athanasou, N.A.3
  • 27
    • 0036338720 scopus 로고    scopus 로고
    • Intraoperative frozen section analysis in revision total joint arthroplasty
    • Banit DM, Kaufer H, Hartford JM. Intraoperative frozen section analysis in revision total joint arthroplasty. Clin Orthop 2002;401:230-8.
    • (2002) Clin Orthop , vol.401 , pp. 230-238
    • Banit, D.M.1    Kaufer, H.2    Hartford, J.M.3
  • 29
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban RM, Jacobs JJ, Tomlinson MJ, et al. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am 2000;82:457-76.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3
  • 30
    • 9644263984 scopus 로고    scopus 로고
    • Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty
    • Urban RM, Tomlinson MJ, Hall DJ, et al. Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty 2004;19(suppl 3):94-101.
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL. 3 , pp. 94-101
    • Urban, R.M.1    Tomlinson, M.J.2    Hall, D.J.3
  • 31
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt and nickel after total hip replacement: A six month study
    • Black J, Maitin EC, Gelman H, et al. Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study. Biomaterials 1983;4:160-4.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3
  • 32
    • 0021915153 scopus 로고
    • Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplasty
    • Bartolozzi A, Black J. Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplasty. Biomaterials 1985;6:2-8.
    • (1985) Biomaterials , vol.6 , pp. 2-8
    • Bartolozzi, A.1    Black, J.2
  • 33
    • 0022892499 scopus 로고
    • Metal ions in body fluids after arthroplasty
    • Pazzaglia UE, Black J. Metal ions in body fluids after arthroplasty. Acta Orthop Scand 1986;57:415-8.
    • (1986) Acta Orthop Scand , vol.57 , pp. 415-418
    • Pazzaglia, U.E.1    Black, J.2
  • 34
  • 35
    • 0032923862 scopus 로고    scopus 로고
    • Metal release and excretion from cementless titanium alloy total knee replacements
    • Jacobs JJ, Silverton C, Hallab NJ, et al. Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop 1999;358:173-80.
    • (1999) Clin Orthop , vol.358 , pp. 173-180
    • Jacobs, J.J.1    Silverton, C.2    Hallab, N.J.3
  • 36
    • 0026347807 scopus 로고
    • Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy
    • Jacobs JJ, Skipor AK, Black J, et al. Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. J Bone Joint Surg Am 1991;73:1475-86.
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 1475-1486
    • Jacobs, J.J.1    Skipor, A.K.2    Black, J.3
  • 37
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • Lhotka C, Szekeres T, Steffan I, et al. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res 2003;21:189-95.
    • (2003) J Orthop Res , vol.21 , pp. 189-195
    • Lhotka, C.1    Szekeres, T.2    Steffan, I.3
  • 38
    • 9644281005 scopus 로고    scopus 로고
    • Can metal levels be used to monitor metal-on-metal hip arthroplasties?
    • Jacobs JJ, Skipor AK, Campbell PA, et al. Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty 2004;19(suppl 3):59-65.
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL. 3 , pp. 59-65
    • Jacobs, J.J.1    Skipor, A.K.2    Campbell, P.A.3
  • 39
    • 18944372870 scopus 로고    scopus 로고
    • Metal ion levels after metal-on-metal proximal femoral replacements: A 30-year follow-up
    • Dunstan E, Sanghrajka AP, Tilley S, et al. Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up. J Bone Joint Surg Br 2005;87:628-31.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 628-631
    • Dunstan, E.1    Sanghrajka, A.P.2    Tilley, S.3
  • 41
    • 23344445560 scopus 로고    scopus 로고
    • Intraspinal metalloma resulting in late paraparesis
    • Tezer M, Kuzgun U, Hamzaoglu A, et al. Intraspinal metalloma resulting in late paraparesis. Arch Orthop Trauma Surg 2005;125:417-21.
    • (2005) Arch Orthop Trauma Surg , vol.125 , pp. 417-421
    • Tezer, M.1    Kuzgun, U.2    Hamzaoglu, A.3
  • 43
    • 17644383668 scopus 로고    scopus 로고
    • Corrosion of spinal implants retrieved from patients with scoliosis
    • Akazawa T, Minami S, Takahashi K, et al. Corrosion of spinal implants retrieved from patients with scoliosis. J Orthop Sci 2005;10:200-5.
    • (2005) J Orthop Sci , vol.10 , pp. 200-205
    • Akazawa, T.1    Minami, S.2    Takahashi, K.3
  • 44
    • 3542993218 scopus 로고    scopus 로고
    • Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain
    • Senaran H, Atilla P, Kaymaz F, et al. Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain. Spine 2004;29:1618-23.
    • (2004) Spine , vol.29 , pp. 1618-1623
    • Senaran, H.1    Atilla, P.2    Kaymaz, F.3
  • 45
    • 0142089924 scopus 로고    scopus 로고
    • Spinal implant debris-induced osteolysis
    • Hallab NJ, Cunningham BW, Jacobs JJ. Spinal implant debris-induced osteolysis. Spine 2003;28(suppl):125-38.
    • (2003) Spine , vol.28 , Issue.SUPPL. , pp. 125-138
    • Hallab, N.J.1    Cunningham, B.W.2    Jacobs, J.J.3
  • 46
    • 0036095572 scopus 로고    scopus 로고
    • The influence of material and design features on the mechanical properties of transpedicular spinal fixation implants
    • Hahn M, Nassutt R, Delling G, et al. The influence of material and design features on the mechanical properties of transpedicular spinal fixation implants. J Biomed Mater Res 63:354-62.
    • J Biomed Mater Res , vol.63 , pp. 354-362
    • Hahn, M.1    Nassutt, R.2    Delling, G.3
  • 47
    • 0033995197 scopus 로고    scopus 로고
    • Reoperation after primary posterior instrumentation and fusion for idiopathic scoliosis: Toward defining late operative site pain of unknown cause
    • Cook S, Asher M, Lai SM, et al. Reoperation after primary posterior instrumentation and fusion for idiopathic scoliosis: toward defining late operative site pain of unknown cause. Spine 2000;25:463-8.
    • (2000) Spine , vol.25 , pp. 463-468
    • Cook, S.1    Asher, M.2    Lai, S.M.3
  • 48
    • 0033562411 scopus 로고    scopus 로고
    • Corrosion on an internal spinal fixator system
    • Vieweg U, van Roost D, Wolf HK, et al. Corrosion on an internal spinal fixator system. Spine 1999;24:946-51.
    • (1999) Spine , vol.24 , pp. 946-951
    • Vieweg, U.1    van Roost, D.2    Wolf, H.K.3
  • 49
    • 0033134799 scopus 로고    scopus 로고
    • Metal debris from titanium spinal implants
    • Wang JC, Yu WD, Sandhu HS, et al. Metal debris from titanium spinal implants. Spine 1999;24:899-903.
    • (1999) Spine , vol.24 , pp. 899-903
    • Wang, J.C.1    Yu, W.D.2    Sandhu, H.S.3
  • 50
    • 0024603840 scopus 로고
    • Role of corrosion in Harrington and Luque rods failure
    • Prikryl M, Srivastava SC, Viviani GR, et al. Role of corrosion in Harrington and Luque rods failure. Biomaterials 1989;10:109-17.
    • (1989) Biomaterials , vol.10 , pp. 109-117
    • Prikryl, M.1    Srivastava, S.C.2    Viviani, G.R.3
  • 51
    • 18244399600 scopus 로고    scopus 로고
    • Serum levels of nickel and chromium after instrumented posterior spinal arthrodesis
    • Kim YJ, Kassab F, Berven SH, et al. Serum levels of nickel and chromium after instrumented posterior spinal arthrodesis. Spine 2005;30:923-6.
    • (2005) Spine , vol.30 , pp. 923-926
    • Kim, Y.J.1    Kassab, F.2    Berven, S.H.3
  • 52
    • 0038046347 scopus 로고    scopus 로고
    • Metal concentrations in serum and hair of patients with titanium alloy spinal implants
    • Kasai Y, Iida R, Uchida A. Metal concentrations in serum and hair of patients with titanium alloy spinal implants. Spine 2003;28:1320-1326.
    • (2003) Spine , vol.28 , pp. 1320-1326
    • Kasai, Y.1    Iida, R.2    Uchida, A.3
  • 53
    • 34548117969 scopus 로고    scopus 로고
    • American Conference of Government Industrial Hygienists. Chromium. In: Documentation of the Threshold Limit Values for Chemical Substances in the Workroom Environment: Chromium. Cincinnati, OH: American Conference of Government Industrial Hygienists; 1991:91-6.
    • American Conference of Government Industrial Hygienists. Chromium. In: Documentation of the Threshold Limit Values for Chemical Substances in the Workroom Environment: Chromium. Cincinnati, OH: American Conference of Government Industrial Hygienists; 1991:91-6.
  • 55
    • 34548130388 scopus 로고    scopus 로고
    • XProStatistical Software, version 3.0 User's Guide
    • Dataxiom Software
    • Dataxiom Software. XProStatistical Software, version 3.0 User's Guide. Los Angeles: Dataxiom Software; 2003:68.
    • (2003) Los Angeles: Dataxiom Software , pp. 68
  • 57
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt chromium wear and corrosion products and biologic reactions
    • Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop 1996;329(suppl):233-43.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 233-243
    • Merritt, K.1    Brown, S.A.2
  • 58
    • 0024797834 scopus 로고
    • Urinary excretion of chromium in chromeplaters after discontinued exposure
    • Lindberg E, Vesterberg O. Urinary excretion of chromium in chromeplaters after discontinued exposure. Am J Ind Med 1989;16:485-92.
    • (1989) Am J Ind Med , vol.16 , pp. 485-492
    • Lindberg, E.1    Vesterberg, O.2
  • 59
    • 34548113273 scopus 로고    scopus 로고
    • www.hse.gov.uk/aboutus/hsc/ iacs/acts/watch/100604/p10ann1.pdf.
  • 60
    • 0033626538 scopus 로고    scopus 로고
    • Serumcobalt- und Serumchromspiegel bei zwei chronisch niereninsuffizienten Patientinnen mit Hufttotalendoprothese und Metall-Metall-Gleitpaarung
    • Brodner W, Grohs JG, Bitzan P, et al. Serumcobalt- und Serumchromspiegel bei zwei chronisch niereninsuffizienten Patientinnen mit Hufttotalendoprothese und Metall-Metall-Gleitpaarung. Z Orthop Ihre Grenzgeb 2000;138:425-9.
    • (2000) Z Orthop Ihre Grenzgeb , vol.138 , pp. 425-429
    • Brodner, W.1    Grohs, J.G.2    Bitzan, P.3
  • 61
    • 0029789979 scopus 로고    scopus 로고
    • Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty
    • Visuri T, Pukkala E, Paavolainen P, et al. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop 1996;329(suppl):280-9.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 280-289
    • Visuri, T.1    Pukkala, E.2    Paavolainen, P.3
  • 62
    • 0029837641 scopus 로고    scopus 로고
    • Development of hematopoietic cancers after implantation of total joint replacement
    • Gillespie WJ, Henry DA, O'Connell DL, et al. Development of hematopoietic cancers after implantation of total joint replacement. Clin Orthop 1996;329(suppl):290-6.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 290-296
    • Gillespie, W.J.1    Henry, D.A.2    O'Connell, D.L.3
  • 63
    • 0029926973 scopus 로고    scopus 로고
    • Cancer risk from orthopedic prostheses
    • Coleman MP. Cancer risk from orthopedic prostheses. Ann Clin Lab Sci 1996;26:139-46.
    • (1996) Ann Clin Lab Sci , vol.26 , pp. 139-146
    • Coleman, M.P.1
  • 64
    • 0036604465 scopus 로고    scopus 로고
    • Incidence of cancer among patients with knee implants in Sweden, 1980-1994
    • Fryzek JP, Ye W, Signorello LB, et al. Incidence of cancer among patients with knee implants in Sweden, 1980-1994. Cancer 2002;4:3057-62.
    • (2002) Cancer , vol.4 , pp. 3057-3062
    • Fryzek, J.P.1    Ye, W.2    Signorello, L.B.3
  • 65
    • 18044396545 scopus 로고    scopus 로고
    • Cancer following hip and knee arthroplasty: Record linkage study
    • Goldacre MJ, Wotton CJ, Seagroatt V, et al. Cancer following hip and knee arthroplasty: record linkage study. Br J Cancer 2005;2:1298-301.
    • (2005) Br J Cancer , vol.2 , pp. 1298-1301
    • Goldacre, M.J.1    Wotton, C.J.2    Seagroatt, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.