1
-
-
0032456868
-
Shape memory and superelastic alloys: The new medical materials with growing demand
-
Moorleghem WV, Chandrasekaran M, Reynaerts D, Peirs J, Brussel HV. Shape memory and superelastic alloys: The new medical materials with growing demand. Biomed Mater Res 1998;8:55-60.
-
(1998)
Biomed Mater Res
, vol.8
, pp. 55-60
-
-
Moorleghem, W.V.1
Chandrasekaran, M.2
Reynaerts, D.3
Peirs, J.4
Brussel, H.V.5
-
2
-
-
0342796046
-
Nitinol stents versus stainless steel: Thrombogenicity study using an ex vivo model
-
to appear
-
Thierry B, Merhi Y, Trepanier C, Bilodeau L, Yahia L'H, Tabrizian M. Nitinol stents versus stainless steel: Thrombogenicity study using an ex vivo model. J Am Coll Cadr (to appear).
-
J Am Coll Cadr
-
-
Thierry, B.1
Merhi, Y.2
Trepanier, C.3
Bilodeau, L.'H.4
Yahia, L.5
Tabrizian, M.6
-
3
-
-
0029739551
-
Subacute thrombosis and vascular injury resulting from slotted-tube Nitinol and stainless steel stents in a rabbit carotid artery model
-
Sheth S, Litvack F, Dev V, Fishbein MC, Forrester JS, Eigler N. Subacute thrombosis and vascular injury resulting from slotted-tube Nitinol and stainless steel stents in a rabbit carotid artery model. Circulation 1996;94:1733-1740.
-
(1996)
Circulation
, vol.94
, pp. 1733-1740
-
-
Sheth, S.1
Litvack, F.2
Dev, V.3
Fishbein, M.C.4
Forrester, J.S.5
Eigler, N.6
-
4
-
-
0031830801
-
Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding Nitinol stent in an experimental model
-
Carter AJ, Scott D, Laird JR, Bailey L, Kovach JA, Hoopes TG, et al. Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding Nitinol stent in an experimental model. Cathet Cardiovasc Diagn 1998;44:193-201.
-
(1998)
Cathet Cardiovasc Diagn
, vol.44
, pp. 193-201
-
-
Carter, A.J.1
Scott, D.2
Laird, J.R.3
Bailey, L.4
Kovach, J.A.5
Hoopes, T.G.6
-
6
-
-
0017642736
-
Metal sensitivity in patients treated for tibial fractures with plates of stainless steel
-
Cramers M, Lucht L. Metal sensitivity in patients treated for tibial fractures with plates of stainless steel. Acta Orthop Scand 1977;48:245-249.
-
(1977)
Acta Orthop Scand
, vol.48
, pp. 245-249
-
-
Cramers, M.1
Lucht, L.2
-
7
-
-
4243266733
-
Nickel allergy in patients with in-stent restenosis
-
XXIst Congress of the European Society of Cardiology
-
Köster R, Vieluf D, Kiehn M, Sommerauer M, Kä J, Meinertz T, Hamm CW. Nickel allergy in patients with in-stent restenosis [abstr], XXIst Congress of the European Society of Cardiology. Eur Heart J 1999;20:605.
-
(1999)
Eur Heart J
, vol.20
, pp. 605
-
-
Köster, R.1
Vieluf, D.2
Kiehn, M.3
Sommerauer, M.4
Kä, J.5
Meinertz, T.6
Hamm, C.W.7
-
8
-
-
0032943419
-
Ability of nicontaining biomedical alloys to activate monocytes and endothelial cells in vitro
-
Wataha JC, Lockwood PE, Marek M, Ghazi M. Ability of Nicontaining biomedical alloys to activate monocytes and endothelial cells in vitro. J Biomed Mater Res 1999;45:251-257.
-
(1999)
J Biomed Mater Res
, vol.45
, pp. 251-257
-
-
Wataha, J.C.1
Lockwood, P.E.2
Marek, M.3
Ghazi, M.4
-
9
-
-
0030560643
-
Titanium, chromium and cobalt ions modulate the release of bone-associated cytokynes by human monocytes/macrophages in vitro
-
Wang JY, Wicklund BH, Gustilo RB, Tsukayama DT. Titanium, chromium and cobalt ions modulate the release of bone-associated cytokynes by human monocytes/macrophages in vitro. Biomaterials 1996;17:2233-2240.
-
(1996)
Biomaterials
, vol.17
, pp. 2233-2240
-
-
Wang, J.Y.1
Wicklund, B.H.2
Gustilo, R.B.3
Tsukayama, D.T.4
-
10
-
-
0031727764
-
Metal release in patient who have had a primary total hip arthroplasty
-
Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J. Metal release in patient who have had a primary total hip arthroplasty. J Bone Joint Surg 1998;80A:1447-1458.
-
(1998)
J Bone Joint Surg
, vol.80 A
, pp. 1447-1458
-
-
Jacobs, J.J.1
Skipor, A.K.2
Patterson, L.M.3
Hallab, N.J.4
Paprosky, W.G.5
Black, J.6
-
11
-
-
0343666303
-
Tantalum coating reduces surface corrosion of stents
-
XXlst Congress of the European Society of Cardiology
-
Frey AW, Schwarzacher S, Tataru MCH, Roskamm H, Yeung A. Tantalum coating reduces surface corrosion of stents [abstr]. XXlst Congress of the European Society of Cardiology. Eur Heart J 1999;20:272.
-
(1999)
Eur Heart J
, vol.20
, pp. 272
-
-
Frey, A.W.1
Schwarzacher, S.2
Tataru, M.C.H.3
Roskamm, H.4
Yeung, A.5
-
12
-
-
0032052625
-
Electrochemical and surface characterization of a nickel-titanium alloy
-
Wever DJ, Veldhuizen AG, de Vries J, Busscher HJ, Uges DRA, van Horn JR. Electrochemical and surface characterization of a nickel-titanium alloy. Biomaterials 1998;19:761-769.
-
(1998)
Biomaterials
, vol.19
, pp. 761-769
-
-
Wever, D.J.1
Veldhuizen, A.G.2
De Vries, J.3
Busscher, H.J.4
Uges, D.R.A.5
Van Horn, J.R.6
-
13
-
-
2642582913
-
Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
-
Ryhanen J, Niemi E, Serlo W, Niemela E, Sandvik P, Pernu H, Salo T. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 1997;35:451-457.
-
(1997)
J Biomed Mater Res
, vol.35
, pp. 451-457
-
-
Ryhanen, J.1
Niemi, E.2
Serlo, W.3
Niemela, E.4
Sandvik, P.5
Pernu, H.6
Salo, T.7
-
14
-
-
0032403412
-
Effect of modification of oxide layer on NiTi stent corrosion resistance
-
Trepanier C, Tabrizian M, Yahia L'H, Bilodeau L, Piron DL. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res 1998;43:423-430
-
(1998)
J Biomed Mater Res
, vol.43
, pp. 423-430
-
-
Trepanier, C.1
Tabrizian, M.2
Yahia, L.3
Bilodeau, L.'H.4
Piron, D.L.5
-
15
-
-
0343666304
-
-
Philadelphia, PA: ASTM; Section 13
-
Annual book of ASTM standards. Vol. 13.01. Philadelphia, PA: ASTM; 1996. Section 13.
-
(1996)
Annual Book of ASTM Standards
, vol.13
, Issue.1
-
-
-
16
-
-
0001320271
-
Effects of surface finish on the corrosion of NiTi alloy for biomedical application
-
Pacific Grove, California
-
Trigwell S, Selvaduray G. Effects of surface finish on the corrosion of NiTi alloy for biomedical application. Proc Int Conf Shape Memory and Superelasticity, Pacific Grove, California, 1996. p 383-388.
-
(1996)
Proc Int Conf Shape Memory and Superelasticity
, pp. 383-388
-
-
Trigwell, S.1
Selvaduray, G.2
-
18
-
-
0030484525
-
Effects of multiple sterilization on surface characteristics and in vitro biological responses to titanium
-
Vezeau PJ, Koorbusch GF, Draughn RA, Keller JC. Effects of multiple sterilization on surface characteristics and in vitro biological responses to titanium. J Oral Maxillofac Surg 1996;54: 738-746.
-
(1996)
J Oral Maxillofac Surg
, vol.54
, pp. 738-746
-
-
Vezeau, P.J.1
Koorbusch, G.F.2
Draughn, R.A.3
Keller, J.C.4
-
19
-
-
0014580251
-
Corrosion behaviour of surgical implant materials: 1. Effects of sterilization
-
Revie RW, Greene ND. Corrosion behaviour of surgical implant materials: 1. Effects of sterilization. Corrosion Sci 1969;9: 755-762.
-
(1969)
Corrosion Sci
, vol.9
, pp. 755-762
-
-
Revie, R.W.1
Greene, N.D.2
-
20
-
-
0030340747
-
On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
-
Shabalovskaya SA. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. Biomed Mater Eng 1996;6:267-289.
-
(1996)
Biomed Mater Eng
, vol.6
, pp. 267-289
-
-
Shabalovskaya, S.A.1
-
21
-
-
0003708258
-
-
Eden Prairie, MN, Physical Electronics Industries, Inc.
-
Davis LE, MacDonald NC, Palmberg PW, Riach GE, Weber RE. Handbook of auger electron spectroscopy. Eden Prairie, MN, Physical Electronics Industries, Inc. p. 5-18.
-
Handbook of Auger Electron Spectroscopy
, pp. 5-18
-
-
Davis, L.E.1
MacDonald, N.C.2
Palmberg, P.W.3
Riach, G.E.4
Weber, R.E.5
-
22
-
-
0342796045
-
-
Philadelphia, PA: ASTM; Sections 1-6
-
Annual book of ASTM standards, vol. 13.02. Philadelphia, PA: ASTM; 1996. Sections 1-6.
-
(1996)
Annual Book of ASTM Standards
, vol.13
, Issue.2
-
-
-
25
-
-
0028107940
-
Titanium with different oxides: In vitro studies of protein adsorption and contact activation
-
Wälivaara B, Aronsson BO, Rodahl M, Lausmaa J, Tengvall P. Titanium with different oxides: In vitro studies of protein adsorption and contact activation. Biomaterials 1994;15:827-834.
-
(1994)
Biomaterials
, vol.15
, pp. 827-834
-
-
Wälivaara, B.1
Aronsson, B.O.2
Rodahl, M.3
Lausmaa, J.4
Tengvall, P.5
-
26
-
-
0033119606
-
Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires
-
Rondelli G, Vicentini B. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires. Biomaterials 1999;20:785-792.
-
(1999)
Biomaterials
, vol.20
, pp. 785-792
-
-
Rondelli, G.1
Vicentini, B.2
-
27
-
-
0024709613
-
In vivo measurement of anodic polarization of orthopaedic implant alloys: Comparative study of in vivo and in vitro experiments
-
Nakayama Y. In vivo measurement of anodic polarization of orthopaedic implant alloys: Comparative study of in vivo and in vitro experiments. Biomaterials 1989;10:42-424.
-
(1989)
Biomaterials
, vol.10
, pp. 42-424
-
-
Nakayama, Y.1
-
28
-
-
0018024652
-
Inhibition of corrosion during autoclave sterilization of carbon steel dental instruments
-
Bertolotti RL, Hurst V. Inhibition of corrosion during autoclave sterilization of carbon steel dental instruments. J Am Dent Assoc 1978;97:628-32.
-
(1978)
J Am Dent Assoc
, vol.97
, pp. 628-632
-
-
Bertolotti, R.L.1
Hurst, V.2
-
29
-
-
0032527083
-
Effects of surface treatment on unalloyed titanium implants: Spectroscopic analyses
-
Kilapdi DV, Raikar GN, Liu J, Lemons JE, Vohra Y, Gregory JC. Effects of surface treatment on unalloyed titanium implants: Spectroscopic analyses. J Biomed Mater Res 1998;40:646-659.
-
(1998)
J Biomed Mater Res
, vol.40
, pp. 646-659
-
-
Kilapdi, D.V.1
Raikar, G.N.2
Liu, J.3
Lemons, J.E.4
Vohra, Y.5
Gregory, J.C.6
-
30
-
-
3543129032
-
Corrosion characteristics of Ti-Ni shape-memory alloys in saline solution
-
Pacific Grove, California
-
Wang XX, Zhao LC, Chai W. Corrosion characteristics of Ti-Ni shape-memory alloys in saline solution. Proc Int Conf Shape Memory and Superelasticity, Pacific Grove, California, 1996. p 379-382.
-
(1996)
Proc Int Conf Shape Memory and Superelasticity
, pp. 379-382
-
-
Wang, X.X.1
Zhao, L.C.2
Chai, W.3
-
31
-
-
0022093971
-
Auger electron spectroscopic studies of stainless steel implants
-
Sundgren J-E, Bodo P, Lundstrom I, Berggren A, Hellem S. Auger electron spectroscopic studies of stainless steel implants. J Biomed Mater Res 1985;19:663-671.
-
(1985)
J Biomed Mater Res
, vol.19
, pp. 663-671
-
-
Sundgren, J.-E.1
Bodo, P.2
Lundstrom, I.3
Berggren, A.4
Hellem, S.5
-
32
-
-
0032808131
-
Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations
-
Jia W, Beatty MW, Reinhardt RA, Petro TM, Cohen DM, Hoffman M, et al. Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations. J Biomed Mater Res Appl Biomater 1999;48:488-495.
-
(1999)
J Biomed Mater Res Appl Biomater
, vol.48
, pp. 488-495
-
-
Jia, W.1
Beatty, M.W.2
Reinhardt, R.A.3
Petro, T.M.4
Cohen, D.M.5
Hoffman, M.6
-
34
-
-
0024505038
-
Nickel absorption and kinetics in human volunteers
-
Sunderman FW, Hopfer SM, Sweeny KR, Marcus AH, Most BM, Creason J. Nickel absorption and kinetics in human volunteers. Proc Soc Exp Biol Med 1989;191:5-11.
-
(1989)
Proc Soc Exp Biol Med
, vol.191
, pp. 5-11
-
-
Sunderman, F.W.1
Hopfer, S.M.2
Sweeny, K.R.3
Marcus, A.H.4
Most, B.M.5
Creason, J.6
-
35
-
-
0029814931
-
Distribution of cobalt chromium wear and corrosion products and biologic reactions
-
Merrit K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Rel Res 1996;329S:S233-S243.
-
(1996)
Clin Orthop Rel Res
, vol.329 S
-
-
Merrit, K.1
Brown, S.A.2
-
36
-
-
0032210932
-
The reduction half cell in biomaterials corrosion: Oxygen diffusion profiles near and cell response to polarized titanium surfaces
-
Gilbert JL, Zarka L, Chang E, Thomas CH. The reduction half cell in biomaterials corrosion: Oxygen diffusion profiles near and cell response to polarized titanium surfaces. J Biomed Mater Res 1998;42:321-330.
-
(1998)
J Biomed Mater Res
, vol.42
, pp. 321-330
-
-
Gilbert, J.L.1
Zarka, L.2
Chang, E.3
Thomas, C.H.4
-
37
-
-
0342796043
-
In vitro galvanic corrosion testing of tantalum, nitinol, and type 316L stainless steel stents
-
April 28-May 2, Providence
-
Shin M. In vitro galvanic corrosion testing of tantalum, nitinol, and type 316L stainless steel stents. Soc Biomater 25th ann meet trans, April 28-May 2, Providence, 1999. p 479.
-
(1999)
Soc Biomater 25th Ann Meet Trans
, pp. 479
-
-
Shin, M.1
-
39
-
-
0025918458
-
Calcium phosphates naturally formed on titanium in electrolyte solution
-
Hanawa T, Oda M. Calcium phosphates naturally formed on titanium in electrolyte solution. Biomaterials 1991;12:767-774.
-
(1991)
Biomaterials
, vol.12
, pp. 767-774
-
-
Hanawa, T.1
Oda, M.2
|