메뉴 건너뛰기




Volumn 43, Issue 4, 1998, Pages 433-440

Effect of modification of oxide layer on NiTi stent corrosion resistance

Author keywords

Corrosion resistance; NiTi shape memory alloy; Stents; Surface characterization; Surface treatments

Indexed keywords

BIOCOMPATIBILITY; CORROSION RESISTANCE; ELECTROLYTIC POLISHING; HEAT TREATMENT; NICKEL ALLOYS; NITRIC ACID; OXIDES; PASSIVATION; POLARIZATION; SHAPE MEMORY EFFECT; SURFACE TREATMENT;

EID: 0032403412     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.3.CO;2-R     Document Type: Article
Times cited : (312)

References (33)
  • 1
    • 0023153178 scopus 로고
    • Intravascular stems to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart, U.; Puel, J.; Mirkovitch, V.; Joffre, F.; Kappenberger, L. Intravascular stems to prevent occlusion and restenosis after transluminal angioplasty. N. Engl. J. Med. 316(12):701-706; 1987.
    • (1987) N. Engl. J. Med. , vol.316 , Issue.12 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3    Joffre, F.4    Kappenberger, L.5
  • 2
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys, P. W.; et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N. Engl. J. Med. 331:489-495; 1994.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 489-495
    • Serruys, P.W.1
  • 3
    • 0027934377 scopus 로고
    • A randomized comparison of coronarystent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fishman, D. L.; et al. A randomized comparison of coronarystent placement and balloon angioplasty in the treatment of coronary artery disease. N. Engl. J. Med. 331:496-501; 1994.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 496-501
    • Fishman, D.L.1
  • 4
    • 0026151073 scopus 로고
    • Intracoronary stents
    • Lau, K. W.; Sigwart, U. Intracoronary stents. Ind. Heart J. 43(3):127-139; 1991.
    • (1991) Ind. Heart J. , vol.43 , Issue.3 , pp. 127-139
    • Lau, K.W.1    Sigwart, U.2
  • 5
    • 0030270078 scopus 로고    scopus 로고
    • Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants
    • Berger-Gorbet, M.; Broxup, B.; Rivard, C. H.; Yahia, L'H. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants. J. Biomed. Mater. Res. 32:243-248; 1996.
    • (1996) J. Biomed. Mater. Res. , vol.32 , pp. 243-248
    • Berger-Gorbet, M.1    Broxup, B.2    Rivard, C.H.3    Yahia, L'H.4
  • 7
    • 0002420396 scopus 로고
    • Preliminary data on in vitro study of proliferative rat spleen cell response to Ni-Ti surface characterized using ESCA analysis
    • Pelton, A.; Hodgson, D.; Duerig, T., Eds. Pacific Grove, CA
    • Shabalovskaya, S. A.; Cunnick, J.; Anderegg, J.; Harmon, B.; Sachdeva, R. Preliminary data on in vitro study of proliferative rat spleen cell response to Ni-Ti surface characterized using ESCA analysis. Pelton, A.; Hodgson, D.; Duerig, T., Eds. Shape Memory and Superelastic Technologies Conference Proceedings, Pacific Grove, CA: 1994:209-214.
    • (1994) Shape Memory and Superelastic Technologies Conference Proceedings , pp. 209-214
    • Shabalovskaya, S.A.1    Cunnick, J.2    Anderegg, J.3    Harmon, B.4    Sachdeva, R.5
  • 8
    • 84939677652 scopus 로고
    • Comparative cell culture effects of shape memory metal (Nitinol®), nickel and titanium: A biocompatibility estimation
    • Putters, J. L. M.; Kaulesar Sukul, D. M. K. S.; de Zeeuw, G. R.; Bijma, A.; Besselink, P. A. Comparative cell culture effects of shape memory metal (Nitinol®), nickel and titanium: a biocompatibility estimation. Eur. Surg. Res. 24:378-382; 1992.
    • (1992) Eur. Surg. Res. , vol.24 , pp. 378-382
    • Putters, J.L.M.1    Kaulesar Sukul, D.M.K.S.2    De Zeeuw, G.R.3    Bijma, A.4    Besselink, P.A.5
  • 10
    • 7844250509 scopus 로고
    • Improvement in corrosion resistance in Ti-Ni shape memory alloy for implant by oxide film coating
    • Kyoto, Japan
    • Sohmura, T. Improvement in corrosion resistance in Ti-Ni shape memory alloy for implant by oxide film coating. World Biomaterial Congress Proceedings, Kyoto, Japan; 1988:574.
    • (1988) World Biomaterial Congress Proceedings , pp. 574
    • Sohmura, T.1
  • 11
    • 0027677960 scopus 로고
    • Oxidation and diffusion processes in nickel-titanium oxide systems
    • Espinos, J. P.; Fernandez, A.; Gonzalez-Elipe, A. R. Oxidation and diffusion processes in nickel-titanium oxide systems. Surface Sci. 295:402-410; 1993.
    • (1993) Surface Sci. , vol.295 , pp. 402-410
    • Espinos, J.P.1    Fernandez, A.2    Gonzalez-Elipe, A.R.3
  • 12
    • 0000825105 scopus 로고
    • Surface engineering of titanium and titanium alloys
    • Metals Park, OH: ASM International
    • Bloyce, A.; Morion, P. H.; Bell, T. Surface engineering of titanium and titanium alloys. ASM Handbook, Vol. 5. Metals Park, OH: ASM International; 1994:835-851.
    • (1994) ASM Handbook , vol.5 , pp. 835-851
    • Bloyce, A.1    Morion, P.H.2    Bell, T.3
  • 13
    • 0025807957 scopus 로고
    • Effect of surface treatment on the dissolution of titanium-based implant materials
    • Wisbey, A.; Peter, P. J.; Tuke, M. Effect of surface treatment on the dissolution of titanium-based implant materials. Biomaterials 12:470-473; 1990.
    • (1990) Biomaterials , vol.12 , pp. 470-473
    • Wisbey, A.1    Peter, P.J.2    Tuke, M.3
  • 14
    • 7844235837 scopus 로고    scopus 로고
    • Philadelphia, PA: ASTM; Section 13
    • Annual Book of ASTM Standards, Vol. 13.01. Philadelphia, PA: ASTM; 1996:Section 13.
    • (1996) Annual Book of ASTM Standards , vol.13 , Issue.1
  • 15
    • 1542654907 scopus 로고
    • X-ray photoelectron spectroscopy
    • 9th edition, Philadelphia, PA: ASTM
    • Lumsden, J. B. X-ray photoelectron spectroscopy. Metals Handbook, Vol. 10, 9th edition, Philadelphia, PA: ASTM; 1986:568-580.
    • (1986) Metals Handbook , vol.10 , pp. 568-580
    • Lumsden, J.B.1
  • 19
    • 0019068816 scopus 로고
    • Anodic polarization behavior of TiNi and Ti-6Al-4V in simulated physiological solutions
    • Speck, M.; Fraker, A. C. Anodic polarization behavior of TiNi and Ti-6Al-4V in simulated physiological solutions. J. Dent. Res. 59:1590-1595; 1980.
    • (1980) J. Dent. Res. , vol.59 , pp. 1590-1595
    • Speck, M.1    Fraker, A.C.2
  • 20
    • 0030272059 scopus 로고    scopus 로고
    • Corrosion resistance tests on NiTi shape memory alloy
    • Rondelli, G. Corrosion resistance tests on NiTi shape memory alloy. Biomaterials 17:2003-2008; 1996.
    • (1996) Biomaterials , vol.17 , pp. 2003-2008
    • Rondelli, G.1
  • 21
    • 0001553752 scopus 로고
    • Biocompatibility of nickel-titanium shape memory alloy: An in vitro electrochemical study
    • Okuyama, M.; Yahia, L'H.; Piron, D. L.; Lombardi, S. Biocompatibility of nickel-titanium shape memory alloy: an in vitro electrochemical study. Biomater. Living Syst. Int. 3:145-160; 1995.
    • (1995) Biomater. Living Syst. Int. , vol.3 , pp. 145-160
    • Okuyama, M.1    Yahia, L'H.2    Piron, D.L.3    Lombardi, S.4
  • 22
    • 0026879344 scopus 로고
    • Microanalytical characterization and surface modification of TiNi orthodontic archwires
    • Oshida, Y.; Sachdeva, R. C. L.; Miyazaki, S. Microanalytical characterization and surface modification of TiNi orthodontic archwires. Bio-Med. Mater. Eng. 2:51-69; 1992.
    • (1992) Bio-Med. Mater. Eng. , vol.2 , pp. 51-69
    • Oshida, Y.1    Sachdeva, R.C.L.2    Miyazaki, S.3
  • 23
    • 1342293578 scopus 로고
    • Toxicology of implanted metals
    • Williams, D. F., Ed. Boca Raton, FL: CRC Press
    • Williams, D. F. Toxicology of implanted metals. Williams, D. F., Ed. Fundamentals Aspects of Biocompatibility, Vol. II. Boca Raton, FL: CRC Press; 1981:45-61.
    • (1981) Fundamentals Aspects of Biocompatibility , vol.2 , pp. 45-61
    • Williams, D.F.1
  • 24
    • 0028434177 scopus 로고
    • Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice
    • Takamura, K.; Hayashi, K.; Ishinishi, N.; Yamada, T.; Sugioka, Y. Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice. J. Biomed. Mater. Res. 28:583-589; 1994.
    • (1994) J. Biomed. Mater. Res. , vol.28 , pp. 583-589
    • Takamura, K.1    Hayashi, K.2    Ishinishi, N.3    Yamada, T.4    Sugioka, Y.5
  • 25
    • 0345191677 scopus 로고
    • The oxide film and its effect on shape memory effect and biocompatibility in TiNi alloy
    • Chu, Y.; Tu, H., Ed. International Academic Publishers
    • Xiao-Xiang, W.; Zhi-Yuan, M.; Zhen-Wang, C. The oxide film and its effect on shape memory effect and biocompatibility in TiNi alloy. Chu, Y.; Tu, H., Ed. Shape Memory Materials '94. International Academic Publishers; 1994:621-625.
    • (1994) Shape Memory Materials '94 , pp. 621-625
    • Xiao-Xiang, W.1    Zhi-Yuan, M.2    Zhen-Wang, C.3
  • 27
    • 0028518655 scopus 로고
    • Bone response to surface modified titanium implants: Studies on electropolished implants with different oxide thicknesses and morphology
    • Larsson, C.; Thomsen, P.; Lausmaa, J.; Rodhal, M.; Kasemo, B.; Ericson, L. E. Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. Biomaterials 15:1062-1074; 1994.
    • (1994) Biomaterials , vol.15 , pp. 1062-1074
    • Larsson, C.1    Thomsen, P.2    Lausmaa, J.3    Rodhal, M.4    Kasemo, B.5    Ericson, L.E.6
  • 28
    • 0030332536 scopus 로고    scopus 로고
    • Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating
    • Villermaux, F.; Tabrizian, M.; Yahia, L'H.; Czeremuskin, G.; Piron, D. L. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating. Bio-Med. Mater. Eng. 6:241-254; 1996.
    • (1996) Bio-Med. Mater. Eng. , vol.6 , pp. 241-254
    • Villermaux, F.1    Tabrizian, M.2    Yahia, L.3    Czeremuskin, G.4    Piron, D.L.5
  • 29
    • 0030560906 scopus 로고    scopus 로고
    • Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution
    • Montero-Ocampo, C.; Lopez, H.; Salinas Rodriguez, A. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution. J. Biomed. Mater. Res. 32:583-591; 1996.
    • (1996) J. Biomed. Mater. Res. , vol.32 , pp. 583-591
    • Montero-Ocampo, C.1    Lopez, H.2    Salinas Rodriguez, A.3
  • 33
    • 0024764578 scopus 로고
    • A study of the process of oxidation of titanium nickelide II. Phase composition of the scale
    • Chuprina, V. G. A study of the process of oxidation of titanium nickelide II. Phase composition of the scale. Sov. Powder Metal. Metal Ceram. 28:468-472; 1989.
    • (1989) Sov. Powder Metal. Metal Ceram. , vol.28 , pp. 468-472
    • Chuprina, V.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.