메뉴 건너뛰기




Volumn , Issue 1365, 1999, Pages 210-219

Serum protein carriers of chromium in patients with Cobalt-base alloy total joint replacement components

Author keywords

[No Author keywords available]

Indexed keywords

BINARY ALLOYS; BIOCOMPATIBILITY; CORROSION; IMPLANTS (SURGICAL); JOINT PROSTHESES; MOLECULAR WEIGHT; PROTEINS;

EID: 0033308094     PISSN: 10403094     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1520/stp14275s     Document Type: Article
Times cited : (3)

References (22)
  • 6
    • 0026347807 scopus 로고
    • Metal release and excretion in patients with titanium base alloy total hip replacement components
    • Jacobs, J.J., Skipor, A.K., Black, J., Urban, R.M. and Galante, J.O., "Metal Release and Excretion in Patients with Titanium Base Alloy Total Hip Replacement Components," Journal of Bone and Joint Surgery, Vol. 73A, 1991, pp 1475-1486.
    • (1991) Journal of Bone and Joint Surgery , vol.73 A , pp. 1475-1486
    • Jacobs, J.J.1    Skipor, A.K.2    Black, J.3    Urban, R.M.4    Galante, J.O.5
  • 8
    • 0018899205 scopus 로고
    • Tissue reaction and metal sensitivity
    • Merritt, K. and Brown, S., "Tissue reaction and metal sensitivity," Acta Orthopaedica Scandinavia, Vol. 51, 1980, pp 403-4111.
    • (1980) Acta Orthopaedica Scandinavia , vol.51 , pp. 403-4111
    • Merritt, K.1    Brown, S.2
  • 9
    • 0017596536 scopus 로고
    • Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hipreplacement arthroplasty
    • Brown, G.C., Lockshin, M.D., Salvati, E.A. and Bullough, P.G., "Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hipreplacement arthroplasty," The Journal of Bone and Joint Surgery, Vol. 59-A, 1977, pp 164-168.
    • (1977) The Journal of Bone and Joint Surgery , vol.59 A , pp. 164-168
    • Brown, G.C.1    Lockshin, M.D.2    Salvati, E.A.3    Bullough, P.G.4
  • 14
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt, and nickel after total hip replacement: A six month study
    • Black, J., Maitin, E.C., Gelman, H. and Morris, D.M., "Serum concentrations of chromium, cobalt, and nickel after total hip replacement: a six month study," Biomaterials, Vol. 4, 1983, pp 160-164.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3    Morris, D.M.4
  • 15
    • 0028351802 scopus 로고
    • Competitive binding of chromium cobalt and nickel to serum proteins
    • Yang, J. and Black, J., "Competitive binding of chromium cobalt and nickel to serum proteins," Biomaterials, Vol. 15, 1994, pp 262-268.
    • (1994) Biomaterials , vol.15 , pp. 262-268
    • Yang, J.1    Black, J.2
  • 16
    • 0021337206 scopus 로고
    • Isolation of serum protein organometallic corrosion products from 316L and HS-21 in vitro and in vivo
    • Woodman, J.L., Black, J. and Jiminez, S.A., "Isolation of serum protein organometallic corrosion products from 316L and HS-21 in vitro and in vivo," Journal of Biomedical Materials Research, Vol. 18, 1984, pp 99-114.
    • (1984) Journal of Biomedical Materials Research , vol.18 , pp. 99-114
    • Woodman, J.L.1    Black, J.2    Jiminez, S.A.3
  • 18
    • 0029028485 scopus 로고
    • Study of the chromium binding in plasma of patients on continuous ambulatory peritoneal dialysis
    • Borguet, F., Cornelis, R., Delanghe, J., Lambert, M. and Lameire, N., "Study of the chromium binding in plasma of patients on continuous ambulatory peritoneal dialysis," Clinica Chimica Acta, Vol. 238, 1995, pp 71-84.
    • (1995) Clinica Chimica Acta , vol.238 , pp. 71-84
    • Borguet, F.1    Cornelis, R.2    Delanghe, J.3    Lambert, M.4    Lameire, N.5
  • 19
    • 0021517064 scopus 로고
    • The binding of metal salts and corrosion products to cells and proteins in vitro
    • Merritt, K., "The binding of metal salts and corrosion products to cells and proteins in vitro," Journal of Biomedical Materials Research, Vol. 18, 1984, pp 1005-1015.
    • (1984) Journal of Biomedical Materials Research , vol.18 , pp. 1005-1015
    • Merritt, K.1
  • 20
    • 0028533512 scopus 로고
    • Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements
    • Yang, J. and Merritt, K., "Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements," Jornal of Biomedical Materials Research, Vol. 28, 1994, pp 1249-1258.
    • (1994) Jornal of Biomedical Materials Research , vol.28 , pp. 1249-1258
    • Yang, J.1    Merritt, K.2
  • 21
    • 0007857687 scopus 로고
    • Metal disposition: An analysis of underlying mechanisms
    • R. A. Goyer, C. D. Klaasen and M. P. Waalkes, Ed., Academic Press, New York
    • Foulkes, E., "Metal disposition: An analysis of underlying mechanisms," Metal Toxicology. R. A. Goyer, C. D. Klaasen and M. P. Waalkes, Ed., Academic Press, New York, 1995, pp 3-29.
    • (1995) Metal Toxicology , pp. 3-29
    • Foulkes, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.